A Project Case Study

– is a Cool Roof coating product solution


– Preventive Heat Insulation thru heat
reflection type coating solution
– a technology developed by NASA to
greatly reduce the Solar Heat
penetration inside the building thereby
reducing air-con consumption
– contains millions of “hollow ceramic
beads” that provides dead air space
is a 4-in-1 Cool Roofing Solution

A solar reflective coating that reduces energy consumption and protect


concrete walls, decks, metal roofs, ducts, tanks and any other surface.
Reflects 80% of solar
heat
and UV of up to 96%

Up to 10 Years Warranty!!!
Roof Plan Project Coverage
Roof Plan Project Coverage
Roof Condition Before
Roof Preparation
Power washing Caps sealing and fiber-meshing

Overlaps fiber-meshing Screws tightening and fiber-meshing


Actual Coating using Airless Spray Machine

Roof coating Roof coating

Wall coating Gutter coating


Roof Condition After
BEFORE

AFTER
Roof Outside Temp without
55 ᵒC 57 ᵒC

63 ᵒC
55 ᵒC 64 ᵒC
Roof Outside Temp with
34 ᵒC 34 ᵒC

32 ᵒC 36 ᵒC
Roof Outside Temperature
Temperature readings summary:
Temp Reading Without ThermaCoat With ThermaCoat
1st Reading 55.3oC 34.5oC
2nd Reading 57.2oC 34.4oC
3rd Reading 63.4oC 32.5oC
4th Reading 64.6oC 36.1oC
Average 60.1oC 34.4oC

Temperature Difference = 25.75oC


or 42.83% Heat Reduction
Inside Temp with Insulation and without

42 ᵒC 42 ᵒC

41 ᵒC 41 ᵒC
Inside Temp with Insulation and with

34 ᵒC 34 ᵒC

33 ᵒC 33 ᵒC
Roof Inside Temp with Insulation
Temperature readings summary:
Temp Reading Without ThermaCoat With ThermaCoat
1st Reading 42.0oC 34.2oC
2nd Reading 42.3oC 34.1oC
3rd Reading 41.2oC 33.9oC
4th Reading 41.0oC 33.6oC
Average 41.6oC 34.0oC

Temperature Difference = 7.65oC


or 18.39% Heat Reduction
Roof Inside Temp without Insulation and without

48 ᵒC 49 ᵒC

50 ᵒC 51 ᵒC
Roof Inside Temp without Insulation but with

34 ᵒC 33 ᵒC

35 ᵒC 35 ᵒC
Roof Inside Temp without Insulation
Temperature readings summary:
Temp Reading Without ThermaCoat With ThermaCoat
1st Reading 48.0oC 34.1oC
2nd Reading 49.2oC 33.5oC
3rd Reading 50.8oC 35.1oC
4th Reading 51.2oC 35.2oC
Average 49.8oC 34.5oC

Temperature Difference = 15.33oC


or 30.77% Heat Reduction
Results Summary:

The results show that the roof


“without insulation but with ThermaCoat”
is cooler than the roof
“with Insulation and without ThermaCoat”.

This would also mean that for new stores to be built, you
can already do away with the conventional rolled
insulation and just apply “ThermaCoat” and SAVE on
installation and maintenance cost as well as on
operational cost from the reduced AC electrical use.
Actual Savings Generated and ROI Calculation:

ROI = Php 727,096.00 / Php 42,237.00 = 17 months


This is not yet considering the yearly expenses they incur for the re-waterproofing and repairs
due to water leaks.