CALCULATIONS OF BEARING CAPACITY FOR MALIK HOUSE AT F6/2

1 for strip & 0


Foundation Type 1 Total Tolerable Settlement = 25 mm Strip Foundation
for square

The Foundation to be placed on a grannular/Select Fill material cushion, 1.5 m thick. The Grannular Cushion
Foundation Width B (m) 1.00 OK Special Notes: to placed as per specification mentioned in the Section 7.2.4 of the Geotechnical Investigation Report. The
excavated foundation soil must be inspected by the Exp Geotech Engineer before placement of foundation.

Foundation Length (m) 4.00 1.40

Foundation Depth, D (m) 3.0 1.20

Net allowable bearing pressure (kg/cm2)


Depth of Influence (Di) (m) 1.50
1.00

Factor of Safety FOS 3.00

0.80
Depth of Water Table (Dw) m 30.00

0.60
Vertical Reaction (V) KN -

Horizontal Reaction (H) KN - 0.40

Moment (M) KN.m -


0.20

Load due to Embedment (Ve) KN 56.37


0.00
0 0.5 1 1.5 2 2.5 3 3.5
Foundation width, B (m)

Sheet 1 of 1
E:\1-My Projects\EG201368 Sikandar sb Home\EG201368 Calcs strip (3) Shear Trial 1 1/20/2014 3:44 PM