You are on page 1of 1

WATER TANK DETAIL

GENERAL NOTES

1. ALL DIMENSIONS ARE IN FEETS AND


INCHES.

2. THE RENFORCEMENT SHALL BE COLD


TWISTED DEFORMED BARS (C.T.D) OR
T.M.T. BARS HAVING YIELD. STRENGTH NOT
LESS THAN 415 N/mm AND CONFORMING TO
I.S. 1786 - 1979.

3. DO NOT SCALE ANY DIMENSION.

3
4. FOR RCC. WORK USE MIX M20
CONFORMING TO IS 10262:2009

5. SBC OF SOIL IS 20T/ m2.

6. REINFORCEMENT DETAILING IS
CONFORMING TO IS 13920: 1993
RCC WALL OF 8" THICK
7. THE CLEAR COVER TO THE
REINFORCEMENT SHALL BE AS FOLLOWS
FOOTING = 50mm
opening COLUMN = 40mm
BEAM = 25mm
2 2 SLAB = 20mm
8. CONCRETE M 20

CROSS BAR OF8mm# Dia of bar (mm) Ld (inch)


8 17
10 22
12 27
16 36
20 45

3
25 56
5" THICK SLAB

8mm@8" c/c
RL5
10mm@8" c/c

11'
3 FUTURE FLOOR
RL3

11'
2 FIRST FLOOR

8mm@8" c/c 8mm@8" c/c 8mm@8" c/c 8mm@8" c/c RL2

11'
1 GROUND FLOOR

10mm@8" c/c GL
PL RL1
GL
10mm@8" c/c 10mm@8" c/c RL0
KEY - LEVEL

10mm@8" c/c
PROJECT

DEV, EXTENSION

ARCHITECTURAL CONSULTANT

ASSOCIATES
H. NO: 3-7, NAGARAM, KEESARA,
MEDCHAL, T.S, 500083
DEALT DATE REVISION
06-05-2019
SCALE JOB NO DRAWING NO
1:1 6

SECTION 2-2 SECTION 3-3

WATER TANK DETAILING