You are on page 1of 1

PVWatts Calculator http://pvwatts.nrel.gov/pvwatts.

php

Caution: Photovoltaic system performance


predictions calculated by PVWatts®
include many inherent assumptions and
RESULTS
5,095 kWh per Year *
System output may range from 4,968 to 5,217kWh per year near this location.
uncertainties and do not reflect variations
between PV technologies nor site-specific
characteristics except as represented by Month Solar Radiation AC Energy Energy Value
PVWatts® inputs. For example, PV
modules with better performance are not ( kWh / m2 / day ) ( kWh ) ($)
differentiated within PVWatts® from
lesser performing modules. Both NREL
and private companies provide more January 2.26 233 26
sophisticated PV modeling tools (such as
the System Advisor Model at
http://sam.nrel.gov) that allow for more
February 3.02 285 31
precise and complex modeling of PV
systems. March 4.13 424 47
The expected range is based on 30 years
of actual weather data at the given April 5.23 508 56
location and is intended to provide an
indication of the variation you might see.
For more information, please refer to this May 6.08 603 66
NREL report: The Error Report.
June 6.60 615 68

Disclaimer: The PVWatts® Model


July 6.74 638 70
("Model") is provided by the National
Renewable Energy Laboratory ("NREL"), August 5.96 561 62
which is operated by the Alliance for
Sustainable Energy, LLC ("Alliance") for
the U.S. Department Of Energy ("DOE") September 4.65 431 47
and may be used for any purpose
whatsoever. October 3.53 347 38
The names DOE/NREL/ALLIANCE shall not
be used in any representation, advertising, November 2.48 244 27
publicity or other manner whatsoever to
endorse or promote any entity that adopts
or uses the Model. DOE/NREL/ALLIANCE December 2.03 207 23
shall not provide

any support, consulting, training or


assistance of any kind with regard to the
Annual 4.39 5,096 $ 561
use of the Model or any updates, revisions
or new versions of the Model.

YOU AGREE TO INDEMNIFY DOE/NREL


/ALLIANCE, AND ITS AFFILIATES,
Location and Station Identification
OFFICERS, AGENTS, AND EMPLOYEES
AGAINST ANY CLAIM OR DEMAND,
INCLUDING REASONABLE ATTORNEYS'
Requested Location 615 Jamboree Way, Euless, TX
FEES, RELATED TO YOUR USE, RELIANCE,
OR ADOPTION OF THE MODEL FOR ANY Weather Data Source (TMY2) FORT WORTH, TX 3.7 mi
PURPOSE WHATSOEVER. THE MODEL IS
PROVIDED BY DOE/NREL/ALLIANCE "AS
IS" AND ANY EXPRESS OR IMPLIED Latitude 32.83° N
WARRANTIES, INCLUDING BUT NOT
LIMITED TO THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR
Longitude 97.05° W
A PARTICULAR PURPOSE ARE EXPRESSLY
DISCLAIMED. IN NO EVENT SHALL
DOE/NREL/ALLIANCE BE LIABLE FOR ANY PV System Specifications (Residential)
SPECIAL, INDIRECT OR CONSEQUENTIAL
DAMAGES OR ANY DAMAGES
WHATSOEVER, INCLUDING BUT NOT DC System Size 4.2 kW
LIMITED TO CLAIMS ASSOCIATED WITH
THE LOSS OF DATA OR PROFITS, WHICH
Module Type Standard
MAY RESULT FROM ANY ACTION IN
CONTRACT, NEGLIGENCE OR OTHER
TORTIOUS CLAIM THAT ARISES OUT OF Array Type Fixed (roof mount)
OR IN CONNECTION WITH THE USE OR
PERFORMANCE OF THE MODEL.
Array Tilt 20°
The energy output range is based on
analysis of 30 years of historical weather
data for nearby , and is intended to
Array Azimuth 60°
provide an indication of the possible
interannual variability in generation for a System Losses 14%
Fixed (open rack) PV system at this
location.
Inverter Efficiency 96%

DC to AC Size Ratio 1.1

Economics

Average Cost of Electricity Purchased


0.11 $/kWh
from Utility

Performance Metrics

Capacity Factor 13.8%

1 of 1 6/12/17, 12:27 AM