MACHINE / PROCESS CAPABILITY STUDY

C & E CROSS - REFERENCE TABLE

EQUIPMENT / PROCESS DESCRIPTION : KAIJO WIREBONDER

DEPENDENT RESPONSE

DAM./DEPRESSED WIRE
VARIABLES

PHYSICAL DEF. OF L/F


MISSING WIRE

RANK ORDER
TOTAL
INDEPENDENT
VARIABLES

Leadframe Handling 0 3 3 6 1st


Magazine Chuck Cylinder 0 3 3 6 1st
Elevator Input/Output 0 2 3 5 2nd
Elevator Base 0 2 3 5 2nd
Cut Clamp 3 0 2 5 2nd
Input/Output Gripper 0 2 2 4 3th
Touch Sensor Amp 3 0 1 4 3th
Capillary 3 0 1 4 3th
Wire guide 2 0 2 4 3th
Wire Connectors 3 0 0 3 4th
Pusher Alignment 0 3 0 3 4th
Magazine Tray Stopper 0 1 2 3 4th
Touch Sensor 3 0 0 3 4th
Wire Feed Sensor 3 0 0 3 4th
Magazine Tray 0 1 2 3 4th
Transducer 3 0 0 3 4th
Arm Hold Solenoid/Armature 3 0 0 3 4th
Torch Rod / Spark Rod 3 0 0 3 4th
Wire Feeder Spool 3 0 0 3 4th
Rail Width 0 1 1 2 5th
Wire Feed Air Supply 2 0 0 2 5th
Tension Clamp 1 0 1 2 5th
Optic Sensor (L-B distance) 0 1 0 1 6th
Second Bond Parameter 1 0 0 1 6th
Wire Storage & Handling 1 0 0 1 6th
Rail Track Sensor (Input/Output) 0 1 0 1 6th

TOTAL 37 20 26 83