Basically the diagnosis method is exactly same like IAT sensor. Because
both IAT and ECT sensor are used NTC type thermistor. One distinctive
difference symptom compared to IAT failure is cooling fan turns on
when ECT has some failure. In this case you can expect ECT sensor's
problems. To distinguish between cooling fan problems and ECT failure
you can use actuation test through Hi-scan Pro.
Measuring resistance is the most powerful checking method. The specific value of output voltage
is like on the table bellow.
Mil
P Code Description Threshold Condition1 Condition2 Time
On
P0118 Signal High >138.75
P0117 Signal Low <-38.25
0.5Sec Yes
Model Temp Measured Temp. (-15
P0116 Rationality
)