Professional Documents
Culture Documents
16 Hour Operation:
Number of meals Waste Flow Rate Retention time Storage Factor Interceptor Size
per peak hour Gallon (Hours) (Hour operation) (Capacity in Gallons)
8 Hour Operation:
Number of meals Waste Flow Rate Retention time Storage Factor Interceptor Size
per peak hour Gallon (Hours) (Hour operation) (Capacity in Gallons)
Formula:
Retention Time
Commercial Kitchen 2.5 hours
Single Service Kitchen 1.5 hours
Chamber-1 cu.m
Length Width Depth
4.28
1.70 1.20 2.10
Chamber-2 cu.m
Length Width Depth
4.28
1.70 1.20 2.10
Chamber-3 cu.m
Length Width Depth
1.10
1.00 0.53 2.10
Chamber-4 cu.m
Length Width Depth
1.10
1.00 0.53 2.10
Total cu.m
For 16 hrs operation
10.77
V = 1.125 + 0.75Q
V = 5.67 m3
For the dimensions of septic tank, the depth is 1.80 meters and the width is 1.50 meter:
Total length: