TECDIS Installation Manual Page 67

3.5.5 Start C-Map Chart Manager

Start C-Map Chart Manager -Map chart database,


licensing and diagnostics interface.

This can be useful when Jeppesen Marine support needs to make adjustments to the system.

Check Signature
database has not been corrupted and is in the same state as when provided by C-Map.

3.5.6 Monitor Calibration and Test

This area provides information on the current


monitor calibration status, means to update the
monitor calibration and diagnostics for testing
the serial connection to the monitor.

Proper monitor calibration is needed to ensure


correct chart colors and symbols.

To calibrate the monitor first attempt


automatic calibration by pressing the

not successful,

and selecting the correct calibration file


matching the monitor. If such a file cannot be located, this can be obtained from your TECDIS
support provider.
Page 68 TECDIS Installation Manual

Monitor Calibration Status: Indicates the current status of monitor calibration. The possible
values seen here and steps to rectify any problems are as follows:

Value Solution
Connect the monitor to a serial port in accordance
with Chapter 2: and 3.2.9.
Perform automatic or manual calibration as outlined
below.
The manual calibration file loaded does not match
the connected monitor. Obtain the correct
calibration file from your TECDIS support provider
and repeat manual calibration.
The monitor does not contain the correct monitor
calibration files. Contact your TECDIS support
provider.
Calibration has been successfully performed. Verify
correct calibration by comparing the monitor model
Calibration Name
model label.
Calibration has been successfully performed and
verified.

Calibration Name: Indicates the name of the currently loaded manual or automatic calibration.

Monitor Type: Indicates the monitor model name as reported by the monitor during the last
automatic calibration process.

Identify Monitor and Load Automatic Calibration: Initiates automatic identification of


monitor type and attempts to load automatic calibration data from the monitor.
The possible values seen here are:
Value Solution
Connect the monitor to a serial port in accordance
with Chapter 2: and 3.2.9.
The monitor is not recognized, and manual
calibration is needed.
The monitor is recognized, but a manual calibration
is needed. The monitor ID is shown.
The monitor is recognized, and automatic
calibration is performed.

Allows the operator to manually load a monitor


calibration file.

Provides access to tests to verify correct monitor serial


connection (buzzer test, backlighting adjustment tests and monitor identification test).