You are on page 1of 4

Intelligent, Integrated Infrastructure Solution in an Enclosure

Features and Benefits SmartCabinet™ is a new approach to providing a complete IT


infrastructure solution that contains power, thermal management,
„ Fully integrated - factory assembled and enclosure, power distribution, monitoring and infrastructure
tested for power, thermal management, management all in a simple packaged solution. It is a fully
rack enclosure, power distribution, integrated, industry-leading plug-and-play solution with a ready
monitoring and management, and security to use IT rack space. It eliminates the need to build complex
for IT applications. No dedicated IT room is computer rooms which dramatically improves the speed of system
required. deployment compared to the traditional approach. SmartCabinet™
„ Dust protection and noise insulation is pre-con»gured, pre-installed, and factory tested to ensure
Fully closed operation, cold/hot air is system compatibility and is ready to use from day one.
circulated within the rack for better
temperature and humidity control,
expanding lifespan of IT equipment,
low noise level. Highly suitable for of»ce
environment.
„ Highly Efficient - Built-in high ef»ciency
UPS and cooling equipment, that uses
DC frequency conversion technology for
energy savings.
„ User-friendly interface - Large 7-inch LCD
touch panel that allows for easy access to
system status/alarms/ setting.
„ Fast deployment – SmartCabinet™
provides faster deployment and is ready
to use from day one, removing the need
to build, construct and design computer
rooms which dramatically reduces the
required deployment period compared to
a traditional IT facility build.”
„ Central Management – optional
feature of RDU-M that provides central
management of multiple SmartCabinet
sites.

Applications:
„ Branch of»ces, retail stores, small &
medium sized business of»ces, and
telecommunication sites
„ Branch locations for government,
educational institutions, healthcare,
»nance, business process outsourcing
»rms
„ Warehouse or mobile sites, where
computer/networking room is unavailable
„ Manufacturing sites for automation
control
SmartCabinet™ Solution Components

LED Lighting
1 Low power consumption LED lights that
automatically light up when door is opened.

Power Management Unit


2 Built-in Power Management Unit (PMU)
provides MCB to UPS, Cooling unit, PDU, and
bypass. It also provides surge protection to
SmartCabinet™.
1
Power Distibution
2 3 Outlet switched Power Distribution Unit (PDU)
distribute power to IT equipment and turn on
emergency fans during power outages.

4 Touch Panel LCD Display


User-friendly display provide easy access to
information for power, thermal management,
4 environments, and security
3

Air¼ow Management
5 Separate cold air and hot air channels to prevent
hot exhaust air from circulating to the front of
the cabinet.

5
Temperature / Door Access sensors

6
6 Temperature sensors at front (cold aisle) and
at rear (hot aisle) report critical environmental
information and alarm users if exceeding
con»gurable threshold. The door access
sensors at front/rear report alarms on
unauthorized access.

Central Management and Monitoring


7 Provides central management of SmartCabinet™
by monitoring power, thermal, environments,
security, and providing user interface thru touch
panel LCD display.

7
8 UPS and Batteries
8 5KVA On-line double conversion UPS and battery
cabinet ensures clean power feeding to critical
IT equipment. It also provides backup power to
emergency fans during power outages.

9
Thermal Management and Emergency
10 Fans
The thermal unit provides up to 3KW cooling
9 capacity directly to IT equipment. Since
SmartCabinet is fully sealed, the cool air will
only use to cool down critical IT equipment with
the highest ef»ciency. Two emergency fans
automatically run during power outages ensuring
continuous cooling capability.

Water Leak Detection


10 Water leak sensor provides additional
security for critical IT equipment.
LCD Display

Large touch panel LCD display


provides easy access to all information
about power, thermal management,
environment, alarms, and settings.

Traditional Room vs. SmartCabinet™


Traditional Room SmartCabinet™
Room preparation Required and complex Not required
Multi-vendor
Design and construction Time-consuming Factory designed and pre-con»gured
Multiple issues
Cost of preparation High Low
Requires wall-mounted DB box Built-in system
Power distribution
Costly Surge surpression included
Site preparation period 2-3 weeks 1 day
Aesthetic Different design, color, sizes, etc. Integrated design
Area required 10 - 20 sqm 0.7 - 2 sqm
Usually not available, Fully enclosed system,
Dust protection
High cost IP5X high protection
Cooling/UPS equipment may go as high as 65dB Fully enclosed system,
Noise level
Not suitable in of»ce environment Suitable for of»ce environment <50dB
Individual systems
Fully Integrated system
Monitoring system Low capability
Factory Installed / Connected / Tested
Low integration
User interface Different interfaces for different equipment One integration system for all equipment
Multi-vendors
Post-sales support Single vendor provides full support
Poor technical support
High Low
Relocation cost
Dif»cult Easy
Pre-assembled Not possible Yes
Pre-connected Not possible Yes
Factory tested Not possible Yes
Technical Specifications Emerson Network Power Asia

Rack Size 2000 mm (42U) x 600 mm x 1200 mm Australia Pakistan


Useable U space 29U T: 1800-065345 T: 92-42-36622526 to 28
F: 61-2-97438737 F: 92-42-36622530
Air Flow Management Panel 5U x 4, 2U x 3, 1U x 3, total 29U
Maximum depth of equipment 1023 mm Indonesia Philippines
T: 62-21-2513003 T: 63-2-7207400
Vertical Cable Management Panel 2 F: 62-21-2510622 F: 63-2-6203693
Area 0.6m x 1.2m = 0.72 m2
Japan Singapore
Color RAL7021 Black T: 81-3-54038564 T: 65-64672211
IP Marking IP5X F: 81-3-54032919 F: 65-64670130
Display panel 7" Touch Panel LCD
Korea Thailand
Display Languages English / Chinese T: 82-2-34831500 T: 66-2-6178260
LED Lighting 2 F: 82-2-5927886 F: 66-2-6178277 to 78
System Luminance 88lux/1M Malaysia Vietnam
UPS Capacity 5,000VA / 4,500W T: 603-78845000 T: 84-4-37628908
F: 603-78845188 F: 84-4-37628909
7 minutes @3500W load
UPS Backup time
20 minutes @2000W load New Zealand
System Input Breaker 80A, single phase T: 64-3-3392060
F: 64-3-3392063
System Frequency 50Hz or 60Hz (2 different models)
Power Distribution Units (PDU) 32A input Switched PDU, 18x C13 + 6x C19 While every precaution has been taken to ensure
Lightning Protection / accuracy and completeness herein, Emerson
Level 3, 20KA Network Power assumes no responsibility, and
Surge Suppression disclaims all liability, for damages resulting
Maintenance Bypass Included from use of this information or for any errors or
Cooling Capacity 900W ~ 3,000W, variable speed omissions. Speci»cations are subject to change
without notice.
Refrigerant R410A
Emergency fan Two, one at front bottom and one at rear top Emerson Network Power and Liebert® are
trademarks of Emerson Electric Co. or one of its
System Management (UPS/ af»liated companies. All other names and logos
Yes
Cooling/PDU) referred to are trade names, trademarks, or
Temperature Sensor 2 registered trademarks of their respective owners.
©2014 Emerson Electric Co.
Water Leak Detection 1 piece, 5 meters long
Door Access Sensor 2 AP14SOLS – SmartCabinetV1-DS
Warranty 1 year
* Emerson Network Power reserves the rights to amend the speci»cation without prior notice

Marketing.AP@emerson.com
www.EmersonNetworkPower.Asia