Professional Documents
Culture Documents
Table of Contents
Specifying AFL Premise Optical Cables. . . . . . . . . . . . . . . . . . . . . . 3 MicroCore® Cable
OSP MicroCore® Telcordia GR-20 Micro-Technology
OSP Loose Tube Cable—Gel-Filled Air-Blown Loose Tube Cable . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Non-Armored OSP Loose Tube (LE Series SJ) . . . . . . . . . . . . . . . . . 4 FTTx MicroDrop Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Non-Armored Loose Tube Cable—Double Jacket (LE Series DJ). . . . 6
OSP MicroCore Composite Cable
Single-Jacket Single-Armor OSP Loose Tube (LE Series SASJ). . . . . . 8
eABF Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Double-Jacket Single-Armor OSP Loose Tube (LE Series SADJ). . . . 10
All-Dielectric Armored Rodent-Resistant eABF Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
OSP Loose Tube (LN Series). . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Interconnect Premise MicroCore® Cable . . . . . . . . . . . . . . . . . . . 46
Uniflex® Non-Armored Loose Tube Cable. . . . . . . . . . . . . . . . . . . 14 Simplex Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Uniflex® Armored Loose Tube Cable . . . . . . . . . . . . . . . . . . . . . . 15 Zipcord, Dual-link and Micro-Dual Cable. . . . . . . . . . . . . . . . . . . 50
Heavy Duty Uniflex® Loose Tube Cable . . . . . . . . . . . . . . . . . . . . 16 250 µm Fan-out (Furcation) Tubing. . . . . . . . . . . . . . . . . . . . . . . 52
RIBBON-Link® Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
OSP Loose Tube Cable—Gel-Free
Wrapping Tube Cable (WTC) with SWR®. . . . . . . . . . . . . . . . . . . 17 Indoor Cable
Gel-Free Non-Armored OSP Loose Tube (LE Series Gel-Free SJ) . . . 19 Fiber-In-A-Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Gel-Free Single-Jacket Single-Armor OSP Loose Tube QUAD-link and Circular Premise Cable . . . . . . . . . . . . . . . . . . . . 57
(LE Series Gel-Free SASJ). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Multi-Unit Circular Premise Cable. . . . . . . . . . . . . . . . . . . . . . . . 59
Gel-Free Double-Jacket Single-Armor OSP Loose Tube Low Smoke Zero Halogen Distribution Cable. . . . . . . . . . . . . . . . 61
(LE Series Gel-Free SADJ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Interlocking Armor Technology . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Indoor/Outdoor Loose Tube Cable—Gel-Filled Armored Tight Buffered Circular Premise Cable . . . . . . . . . . . . . . 65
Riser Single-Jacket I/O Loose Tube (LV Series SJ). . . . . . . . . . . . . . 25 Sub-unitized Premise MicroCore® Cable . . . . . . . . . . . . . . . . . . . 67
12-144F Sub-unitized Premise MicroCore® 2.0. . . . . . . . . . . . . . .69
Indoor/Outdoor Loose Tube Cable—Gel-Free Sub-unitized Premise MicroCore® 3.0
Gel-Free Riser Non-Armored Loose Tube (LV Series Gel-Free SJ). . . 27 with SpiderWeb® Ribbon Technology. . . . . . . . . . . . . . . . . . . . 71
Gel-Free Riser Single-Jacket Single-Armor Loose Tube Breakout Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
(LV Series Gel-Free SASJ). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
LSZH Single-Armor Single-Jacket I/O Loose Tube (LL Series SASJ). . . . 31 Indoor/Outdoor Cable
Listed Gel-Free, LSZH, Loose Tube Cable (LL Series). . . . . . . . . . . . 33 Indoor/Outdoor Low Smoke Zero Halogen Breakout Cable. . . . . . 75
Extreme Low Temp LSZH Double Jacket I/O Loose Tube (LA Series). . . 35 Indoor/Outdoor Riser Tight Buffered Cable. . . . . . . . . . . . . . . . . . 77
Gel-Free Extreme Low Temp LSZH Double Jacket I/O Loose Tube Indoor/Outdoor Multi-unit Riser Tight Buffered Cable. . . . . . . . . . 79
(LA Series Gel-Free) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Indoor/Outdoor Plenum Distribution Cable . . . . . . . . . . . . . . . . . 81
XLPO LSZH Double-Jacket I/O Loose Tube (LX Series). . . . . . . . . . 39 Indoor/Outdoor Breakout Cable . . . . . . . . . . . . . . . . . . . . . . . . . 83
Ruggedized Indoor/Outdoor Breakout Cable . . . . . . . . . . . . . . . . 85
1
Fiber Optic Cable
Tactical Cable
Tactical Tight Buffered Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Broadcast Deployable Tight Buffered Cable. . . . . . . . . . . . . . . . . 89
Composite Cable
Copper/Fiber Composite Cable. . . . . . . . . . . . . . . . . . . . . . . . . . 90
2
Fiber Optic Cable
C R 012 5 55 1 0 0 1 AIA
B = Breakout R = Riser 004 = 4 fiber 5 = 50 µm MM 55 = 5.5 mm 1 = AFL standard 0 = Standard 0 = Standard 1 = Standard Strip AIA = Aluminum Interlocking
C = Circular P = Plenum 006 = 6 fiber 6 = 62.5 µm MM 2 = Non-standard 1 = Blue 3 = EZ strip Armor
Premise Cable E = LSZH 012 = 12 fiber 9 = Single-mode U = Unprinted 2 = Orange 6 = 600 µm Tight Buffer AIAR = Aluminum Interlocking
D = Dual-link U = Polyurethane etc. L = 10G 300 m 3 = Green 8 = Medium Strip Armor/Riser Jacket
G = Sub-unitized F = Furcation K = Bend-Insensitive SM 4 = Brown B = Bare AIAP = Aluminum Interlocking
Microcore Armor/Plenum Jacket
B = Bare * more available 5 = Slate G = Elastomer over 250 µm
K = Indoor/Outdoor 6 = White H = Elastomer over 500 µm * or other customer specific information
S = Simplex 7 = Red U = 500 µm Bare Fiber
U = Quad-link 8 = Black
W = Ribbon 9 = Yellow
X = Tactical A = Violet
Z = Zipcord B = Rose
C = Aqua
* Different configurations, fiber types, etc. may be available. Please consult your AFL representative for more details.
Generic Print
OPTICAL FIBER CABLE 50/125 12 FIBER E121250 TYPE OFNR (UL) c(UL) RoHS-COMPLIANT MM/YY OOOOOO METERS REEL NUMBER
Icon Legend
A AFL can add Interlocking Armor to any type of fiber optic cable.
AFL stocks many of our most popular cables for your convenience.
Please contact us at 800-AFL-FIBER or AFLPremiseStock@AFLGlobal.com for more details.
www.AFLglobal.com or (800) 235-3423 © 2008, AFL, all rights reserved. PP-1-00064, Revision 2, 12.14.15
Specifications are subject to change without notice.
3
Fiber Optic Cable
Cable Components
Product Applications
• Long Haul Networking
• Building Interconnections (Campus LAN)
• Trunking Lines Direct to
Telecommunications Closet
• Local Loop
• Distance Learning
Typical Lengths
• Distribution
• Intrabuilding Backbones MAXIMUM LENGTHS*
FIBER SINGLE-MODE MULTIMODE
COUNT FEET METERS FEET METERS
Temperature Specifications 6 - 60 22,900 7,000 22,900 7,000
72 - 96 22,900 7,000 22,900 7,000
TEMPERATURE RANGE 108 -120 22,900 7,000 22,900 7,000
INSTALLATION -30ºC to +70ºC 132 - 144 22,900 7,000 22,900 7,000
OPERATING -40ºC to +70ºC 146 - 216 22,900 7,000 22,900 7,000
STORAGE -40ºC to +75ºC 218 - 288 16,400 5,000 16,400 5,000
290 - 432 14,100 4,300 14,000 4,300
434 - 576 10,800 3,300 11,000 3,300
* Longer lengths may be available upon request.
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00016, Revision 6, 12.14.15
Specifications are subject to change without notice.
4
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00016, Revision 6, 12.14.15
Specifications are subject to change without notice.
5
Fiber Optic Cable
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00015, Revision 5, 12.14.15
Specifications are subject to change without notice.
6
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00015, Revision 5, 12.14.15
Specifications are subject to change without notice.
7
Fiber Optic Cable
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00004, Revision 8, 12.14.15
Specifications are subject to change without notice.
8
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00004, Revision 8, 12.14.15
Specifications are subject to change without notice.
9
Fiber Optic Cable
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00003, Revision 6, 12.14.15
Specifications are subject to change without notice.
10
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00003, Revision 6, 12.14.15
Specifications are subject to change without notice.
11
Fiber Optic Cable
Cable Components
rodent-resistant, low-friction, outer jacket
polyethylene inner jacket
Applications optical fibers
FRP central member
• Long Haul Networking
• Building Interconnections (Campus LAN)
• Steam-tunnel Substreet Drainage Networks
ripcords
• Local Loop
water-blocking system
• Airport (FAA-E-2761c, Type B) gel-filled loose buffer tube
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2009, AFL, all rights reserved. PP-1-00019, Revision 5, 12.14.15
Specifications are subject to change without notice.
12
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
Reel Information
www.AFLglobal.com or (800) 235-3423 © 2009, AFL, all rights reserved. PP-1-00019, Revision 5, 12.14.15
Specifications are subject to change without notice.
13
Fiber Optic Cable
Cable Components
outer jacket
strength elements
buffer tube
optical fiber
water blocking gel
TEMPERATURE RANGE
INSTALLATION -30ºC to +70ºC
OPERATING -40ºC to +70ºC
STORAGE -40ºC to +75ºC
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
Ordering Information
MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS
FIBER NOMINAL DIAMETER NOMINAL WEIGHT LBS (N) INCHES (CM)
AFL NO. COUNT INCHES (MM) LBS/1,000FT (KG/KM) SHORT TERM LONG TERM SHORT TERM LONG TERM
LE00221100N1 2
LE00441100N1 4
LE00661100N1 6
0.31 (7.8) 34 (50) 600 (2670) 200 (890) 6.3 (16.0) 3.1 (8.0)
LE00881100N1 8
LE010A1100N1 10
LE012C1100N1 12
Note: Diameter and weight subject to change without notice
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table above.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00026, Revision 3, 12.14.15
Specifications are subject to change without notice.
14
Fiber Optic Cable
Product Applications
• Service (Drop) Cables • Distance Learning
• Building Interconnections (Campus LAN) • Distribution
• Connectorized Trunking Cables
outer jacket
Cable Components
strength elements
Temperature Specifications
buffer tube
TEMPERATURE RANGE
INSTALLATION -30ºC to +70ºC optical fiber
OPERATING -40ºC to +70ºC water blocking gel
STORAGE -40ºC to +75ºC
ripcord
corrugated steel armoring
Maximum Lengths
NOMINAL REEL A REEL B REEL C
DIAMETER (42 x 32 x 23) (58 x 32 x 28) (66 x 36 x 36)
MM FEET METERS FEET METERS FEET METERS
12.2 7,700 2,345 18,250 5,560 24,400 7,435
* Maximum lengthof 27,500 feet available on larger reels.
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
Ordering Information
MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS
FIBER NOMINAL DIAMETER NOMINAL WEIGHT LBS (N) INCHES (CM)
AFL NO. COUNT INCHES (MM) LBS/1,000FT (KG/KM) SHORT TERM LONG TERM SHORT TERM LONG TERM
LE00221200S1 2
LE00441200S1 4
LE00661200S1 6
0.48 (12.2) 95 (140) 600 (2670) 200 (890) 9.6 (25.0) 4.8 (13.0)
LE00881200S1 8
LE010A1200S1 10
LE012C1200S1 12
Note: Diameter and weight subject to change without notice
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table above.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00024, Revision 3, 12.14.15
Specifications are subject to change without notice.
15
Fiber Optic Cable
Product Applications
• Service (Drop) Cables • Distance Learning
• Building Interconnections (Campus LAN) • Distribution
• Connectorized Trunking Cables
Maximum Lengths
NOMINAL REEL A REEL B
DIAMETER (42 x 36 x 23) (58 x 36 x 28)
MM FEET METERS FEET METERS
7.8 19,000 5,790 27,500 8,400
9.3 13,300 4,050 27,500 8,400
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
Ordering Information
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00008, Revision 3, 12.14.15
Specifications are subject to change without notice.
16
Fiber Optic Cable
Features
• Access Ready Construction (ARC)
Completely gel-free construction with easy-to-access and identify optical fiber circuits.
• Spider Web Ribbon (SWR) optical fiber technology
Easily ribbonized for mass fusion splicing. SWR is compacted and routed like individual fibers. Ideal for organizing slack loops
in splice enclosures as there is no preferential bending of ribbon.
• Significantly higher fiber density compared to traditional ribbon cables
Offers ability to expand capacity of existing pathways and allows use of smaller, lower cost duct systems.
• Smaller cable diameters and cable weights
Means longer reel lengths that allow for lower scrap rates, easier handling of reels at the site and reduced transportation costs.
• Completely dry water-blocking technology
Reduces time required to prep cable-end and mid-span access resulting in labor savings.
• Compact ribbon bundles
Reduces enclosure/splice tray size requirements allowing for smaller telecommunications space allocation.
• Armored and non-armored packages
Supports all the standard cable deployment options typically found in the OSP environment including, duct, direct buried and aerial.
• Fully qualified to Telcordia GR-20
Provides assurance that the cable will support optical fiber network transport functions now and into the future.
ARC SWR Technology
Rip cord
Water blocking tape
Armor
Strength member
SWR
Sheath
www.AFLglobal.com or (800) 235-3423 © 2015, AFL, all rights reserved. PP-1-00128, Revision 1, 3.8.16
Specifications are subject to change without notice.
17
Fiber Optic Cable
Mechanical Data—Non-Armored
NOMINAL
WEIGHT MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS
FIBER DIAMETER
DESCRIPTION
COUNT LBS/1,000 FT SHORT TERM LONG TERM SHORT TERM LONG TERM
INCHES (MM)
(KG/KM) LBS (N) LBS (N) INCHES (CM) INCHES (CM)
LWSE-144-9-C-144-1-00N1D 144 0.406 (10.3) 54 (80) 600 (2700) 182 (810) 8 (20) 4 (10)
LWSE-288-9-C-72-4-00N1D 288 0.461 (11.7) 68 (101) 600 (2700) 182 (810) 10 (24) 5 (12)
LWSE-432-9-C-72-6-00N1D 432 0.524 (13.3) 88 (130) 600 (2700) 182 (810) 10 (27) 6 (14)
LWSE-576-9-C-72-8-00N1D 576 0.583 (14.8) 108 (160) 600 (2700) 182 (810) 12 (30) 7 (15)
LWSE-864-9-C-72-12-00N1D 864 0.677 (17.2) 145 (217) 600 (2700) 182 (810) 14 (35) 8 (18)
LWSE-1152-9-C-96-12-00N1D 1152 0.720 (18.3) 161 (239) 600 (2700) 182 (810) 15 (38) 8 (19)
LWSE-1728-9-C-144-12-00N1D 1728 0.870 (22.1) 228 (330) 600 (2700) 182 (810) 18 (46) 9 (22)
Optical Fiber
GIGABIT ETHERNET
MAXIMUM ATTENUATION 10 GIGABIT ETHERNET MIN.
MIN. LINK DISTANCE
FIBER TYPE ISO (DB/KM) LINK DISTANCE (METERS)
(METERS)
850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
Single-mode ITU-T G.652/G.657.A1 OS2 N/A 0.35 0.25 N/A 5000 N/A 10000
www.AFLglobal.com or (800) 235-3423 © 2015, AFL, all rights reserved. PP-1-00128, Revision 1, 3.8.16
Specifications are subject to change without notice.
18
Fiber Optic Cable
Cable Components
Polyethylene jacket
Features Polyester tape
• Gel-free buffer tubes reduce fiber prep
termination time Optical fiber
• SZ-stranded cable core for easy mid-span FRP central member
access of fibers Rip cord
• UV-stabilized outer jacket for long-term Water-blocking system
performance in aerial applications Gel-free loose buffer tube
• 6 to 288 fibers allow for specific cable
choices for multiple applications
• Standards compliance:
- ANSI/ICEA S-87-640 Typical Lengths
- Telcordia GR-20 MAXIMUM LENGTHS*
- RDUP PE-90 FIBER SINGLE-MODE MULTIMODE
COUNT FEET METERS FEET METERS
6 - 60 22,900 7,000 22,900 7,000
Temperature Specifications 72 - 96 22,900 7,000 22,900 7,000
TEMPERATURE RANGE 108 -120 22,900 7,000 22,900 7,000
INSTALLATION -30ºC to +70ºC 132 - 144 22,900 7,000 22,900 7,000
OPERATING -40ºC to +70ºC 146 - 216 22,900 7,000 22,900 7,000
STORAGE -40ºC to +75ºC 218 - 288 16,400 5,000 16,400 5,000
290 - 432 14,100 4,300 14,000 4,300
434 - 576 10,800 3,300 11,000 3,300
* Longer lengths may be available upon request.
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00101, Revision 2, 12.14.15
Specifications are subject to change without notice.
19
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00101, Revision 2, 12.14.15
Specifications are subject to change without notice.
20
Fiber Optic Cable
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00100, Revision 2, 12.14.15
Specifications are subject to change without notice.
21
Fiber Optic Cable
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00100, Revision 2, 12.14.15
Specifications are subject to change without notice.
22
Fiber Optic Cable
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00102, Revision 1, 12.14.15
Specifications are subject to change without notice.
23
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00102, Revision 1, 12.14.15
Specifications are subject to change without notice.
24
Fiber Optic Cable
Applications
• Building Interconnections (Campus LAN) Cable Components
PVC jacket
• Trunking Lines Direct to
strength elements
Telecommunications Closet
binder
• Local Loop
• Distance Learning water blocking system
• Distribution FRP central member
• Intrabuilding Backbones optical fiber
• MSHA Approved for Mining Applications
rip cord
gel-filled loose buffer tube
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00010, Revision 4, 12.14.15
Specifications are subject to change without notice.
25
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00010, Revision 4, 12.14.15
Specifications are subject to change without notice.
26
Fiber Optic Cable
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00103, Revision 2, 12.14.15
Specifications are subject to change without notice.
27
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00103, Revision 2, 12.14.15
Specifications are subject to change without notice.
28
Fiber Optic Cable
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00104, Revision 2, 12.14.15
Specifications are subject to change without notice.
29
Fiber Optic Cable
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00104, Revision 2, 12.14.15
Specifications are subject to change without notice.
30
Fiber Optic Cable
Cable Components
FRP central member
water blocking layer
steel armor
Features flame retardant LSZH jacket
• Indoor/Outdoor Applications gel filled buffer tube
• Steel armor optical fibers
• Low toxicity, flame retardant construction
• Suitable for placement in cable trays per rip cord
IEEE 383
• 12-144 fibers supports multiple Typical Lengths
networking configurations
MAXIMUM LENGTHS*
SINGLE-MODE MULTIMODE
Temperature Specifications FIBER COUNT FEET METERS FEET METERS
TEMPERATURE RANGE 2 - 12 22,900 7,000 22,900 7,000
INSTALLATION -20ºC to +60ºC 18 - 96 22,900 7,000 22,900 7,000
OPERATING -40ºC to +70ºC 108 -120 22,900 7,000 22,900 7,000
STORAGE -40ºC to +75ºC 132 - 144 22,900 7,000 22,900 7,000
* Longer lengths may be available upon request.
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00106, Revision 2, 12.14.15
Specifications are subject to change without notice.
31
Fiber Optic Cable
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00106, Revision 2, 12.14.15
Specifications are subject to change without notice.
32
Fiber Optic Cable
Cable Components
LSZH Jacket
Optical fiber
Gel-free loose buffer tube
Optional corrugated steel armoring
FRP central member
Rip cord
Water-blocking system
Optical Information
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(8) 62.5/125 GIGA-Link™ 1000 3.5 1.2 N/A N/A 350 600 500 1000
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(7) 50/125 GIGA-Link™ 2000 2.9 0.9 N/A N/A 500 800 750 2000
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2015, AFL, all rights reserved. PP-1-00117, Revision 1, 2.12.15
Specifications are subject to change without notice.
33
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number corresponding to desired fiber type below.
5 = 50/125 µm multimode GIGA-Link™ 600
7 = 50/125 µm multimode GIGA-Link™ 2000
6 = 62.5/125 µm multimode GIGA-Link™ 300
8 = 62.5/125 µm multimode GIGA-Link™ 1000
www.AFLglobal.com or (800) 235-3423 © 2015, AFL, all rights reserved. PP-1-00117, Revision 1, 2.12.15
Specifications are subject to change without notice.
34
Fiber Optic Cable
Applications Features
Network Connectivity for: • Fiber Range 12-144
• Oil and Gas fields • OFNG-LS Listed, CSA-FT4
• Low Temperature Environments • IEEE Flame Test
• Refineries • ICEA S-104-696
• Mining • CSA 22.2 No. 230 and 232
• Mass Transit • Increase tensile load rating
• Chemical Resistance testing per ASTM D412
Temperature Range • 2X Crush Resistance compared to standard fiber optic cables
FIBER COUNT • 2X Cold Impact Resistance compared to standard fiber optic cables
12-72 FIBERS,
12-144 FIBERS, • Self-supporting capability (contract factory for system design support)
8- AND
6-POSITION
12-POSITION
CORE
CORES Cable Components
Operating -55ºC to +70ºC -60ºC to +70ºC
Storage -60ºC to +70ºC -60ºC to +70ºC Anti-buckling element
Installation -30ºC to +50ºC -30ºC to +70ºC Water blocking layer
Inner FR-LSZH jacket
Outer FR-LSZH chemical-resistant jacket
Mechanical
Gel filled buffer tube
PARAMETER VALUE Optical fibers
Crush 440N/CM
Aramid cut-resistant matrix
Cold Impact 8.8 N*m
Tensile Rip cord
Installation 1,000 lbs (4,450N)
Operational 400 lbs (1,780N)
www.AFLglobal.com or (800) 235-3423 © 2013, AFL, all rights reserved. PP-1-00094, Revision 5, 1.27.16
Specifications are subject to change without notice.
35
Fiber Optic Cable
Ordering Information
NOMINAL NOMINAL MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS
DIAMETER WEIGHT LBS (N) INCHES (CM)
6-POSITION, FIBER
-50ºC OPTION COUNT INCHES MM LBS/1,000 FT KG/KM INSTALLATION OPERATION INSTALLATION OPERATION
LA012C6111N1 12 0.606 15.4 154 229 1000 (4,450) 400 (1,780) 13 (31) 6 (16)
LA024C6111N1 24 0.606 15.4 154 229 1000 (4,450) 400 (1,780) 13 (31) 6 (16)
LA048C6111N1 48 0.606 15.4 153 227 1000 (4,450) 400 (1,780) 13 (31) 6 (16)
LA072C6111N1 72 0.606 15.4 152 225 1000 (4,450) 400 (1,780) 13 (31) 6 (16)
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table above.
www.AFLglobal.com or (800) 235-3423 © 2013, AFL, all rights reserved. PP-1-00094, Revision 5, 1.27.16
Specifications are subject to change without notice.
36
Fiber Optic Cable
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00109, Revision 5, 1.27.16
Specifications are subject to change without notice.
37
Fiber Optic Cable
Ordering Information
NOMINAL NOMINAL MAXIMUM TENSILE LOAD LBS MINIMUM BEND RADIUS
DIAMETER WEIGHT (N) INCHES (CM)
FIBER
AFL NO. COUNT INCHES MM LBS/1,000 FT KG/KM INSTALLATION OPERATION INSTALLATION OPERATION
LA012C6111N1D 12 0.575 14.6 140 209 990 (4400) 290 (1300) 13(29.4) 6 (14.6)
LA024C6111N1D 24 0.575 14.6 139 207 990 (4400) 290 (1300) 13(29.4) 6 (14.6)
LA048C6111N1D 48 0.575 14.6 136 202 990 (4400) 290 (1300) 13(29.4) 6 (14.6)
LA072C6111N1D 72 0.575 14.6 133 197 990 (4400) 290 (1300) 13(29.4) 6 (14.6)
LA096C8111N1D 96 0.638 16.2 156 233 990 (4400) 290 (1300) 15(32.6) 6 (16.2)
LA144CC111NI D 144 0.776 19.7 199 297 990 (4400) 290 (1300) 18(396) 8 (19.7)
LA288C03111NI D 288 0.89 22.6 264 393 990 (4400) 290 (1300) 20(45.4) 9 (22.6)
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table above.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00109, Revision 5, 1.27.16
Specifications are subject to change without notice.
38
Fiber Optic Cable
Applications Features
• Subway tunnels • Fiber counts up to 72
• Railway right-of-way • Low smoke zero halogen, thermoset jacket
• Airport terminals • Optional rodent resistant armor available
• Confined space pathways • Resistant to lubricating oil (Mil-L-23699), hydraulic fluid (Mil-H-5606),
• Steam tunnels gasoline and deionized water
• Industrial • NEC OFNG-LS listed
• Mining • NEC OFCG-LS listed (steel armor option)
• Shipboard • Meets or exceeds requirements of NFPA 130 and NFPA 502
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2009, AFL, all rights reserved. PP-1-00057, Revision 6, 12.14.15
Specifications are subject to change without notice.
39
Fiber Optic Cable
NOTES:
1. Diameter and weight subject to change without notice.
2. For other types of LSZH Cables, please contact your AFL Representative.
Fiber Types-Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight With Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
AFL typically provides Loose Tube cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
Larger reel sizes may be required to accomodate long cable lengths.
www.AFLglobal.com or (800) 235-3423 © 2009, AFL, all rights reserved. PP-1-00057, Revision 6, 12.14.15
Specifications are subject to change without notice.
40
Fiber Optic Cable
OSP MicroCore®
Telcordia GR-20 Micro-Technology
Air-Blown Loose Tube
AFL OSP MicroCore® cable series is designed for outside plant installation in microduct
conduit systems. The unique, high-fiber density geometry yields a cable construction that
can safely accommodate 12 up to 432 fibers and can be blown into microducts ranging in
inside diameters from 10 mm to 16 mm.
For example, with a 7-way 12.7 mm x 10 mm (conduit with seven microducts) in place,
the system designer has the flexibility to install from 12 to 144 fibers per microduct.
With this approach, only the number of fibers required for initial networking requirements
need to be installed. Then as future network upgrades and expansions are required,
the spare microducts can be jetted with addition OSP MicroCore cables without having
to add additional pathway space and the associated installation labor cost.
Applications Features
• Designed for long -haul, middle-mile • GR-20 compliant water-blocked cable core and buffer tubes
and metro-loop • Colored binder threads for easily identifiable optical fiber bundles
• Campus inter-building backbone • High installation tensile load rating
distribution
• OD compatible with 10 mm to 16 mm inside diameter microducts
• Low-cost fiber upgrade
• 12 up to 432 fibers
migration strategies
Fiber Specifications
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. GIGABIT ETHERNET MIN.
(DB/KM) BANDWIDTH (MHZ•KM) LINK DISTANCE (METERS)
FIBER TYPE 850 NM 1300 NM 1310 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(L) 50/125 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) AFL G.657.A1 Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
www.AFLglobal.com or (800) 235-3423 © 2013, AFL, all rights reserved. PP-1-00027, Revision 11, 3.8.16
Specifications are subject to change without notice.
41
Fiber Optic Cable
OSP MicroCore®
Telcordia GR-20 Micro-Technology Air-Blown Loose Tube
Mechanical Data
NOMINAL MIN. DUCT MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS
LM-SERIES FIBER NOMINAL WEIGHT
FIBERS/ TUBE DIAMETER I.D. LBS (KG) INCHES (CM)
AFL NO. COUNT
IN. MM IN. MM LBS/1,000 FT KG/KM INSTALLATION OPERATION INSTALLATION OPERATION
LM012C6101NS 12 12/1 (5 fillers) 0.299 7.6 0.394 10 31 46 300 (136) 90 (41) 5 (13) 4 (10)
LM024C6101NS 24 12/2 (4 fillers) 0.299 7.6 0.394 10 31 46 300 (136) 90 (41) 5 (13) 4 (10)
LM048C6101NS 48 12/4 (2 fillers) 0.299 7.6 0.394 10 33 49 300 (136) 90 (41) 5 (13) 4 (10)
LM072C6101NS 72 12/6 (no fillers) 0.299 7.6 0.394 10 34 51 300 (136) 90 (41) 5 (13) 4 (10)
LM096O6101NS 96 24/4 (2 fillers) 0.311 7.9 0.394 10 34 51 300 (136) 90 (41) 7 (16) 5 (13)
LM144O6101NS 144 24/6 (no fillers) 0.311 7.9 0.394 10 36 53 300 (136) 90 (41) 7 (16) 5 (13)
LM288R6101NS 288 48/6 (no fillers) 0.409 10.4 0.512 13 63 93 350 (150) 100 (45) 19 (21) 7 (17)
LM432OI301NS 432 24/18 (no fillers) 0.496 12.6 0.630 16 90 134 300 (136) 90 (41) 10 (26) 6 (15)
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
Temperature Specifications
TEMPERATURE RANGE
INSTALLATION -10ºC to +40ºC
OPERATING -30ºC to +70ºC
STORAGE -30ºC to +75ºC
Standard P-U
Length 6,000 m (20,000 ft)
Reel Type Wood
Reel Size 58 x 32 x 28 in.
www.AFLglobal.com or (800) 235-3423 © 2013, AFL, all rights reserved. PP-1-00027, Revision 11, 3.8.16
Specifications are subject to change without notice.
42
Fiber Optic Cable
Features
• Hard-shell casing improves installer handling robustness compared to traditional
Applications micro-fiber units
• Pushable and Air-jettable FTTx • OFRP Push-rod allows FSU to be axially stressed to maximize push distances. No air
subscriber fiber optic drops need for typical FTTH drop applications.
• Distribution route—low fiber-count • Low-friction cable sheath improves push air jetting distances
lateral drops • With air-assist, FSU can be installed over 1000 meters
Cable Components
Optical fibers
Optical fibers Micro strength
Micro strength member
member
Soft polymer
coating
Soft polymer
Dual layer coating
outer coat
Dual layer
outer coat
88Fiber
Fiber8 Fiber 1212Fiber
12 Fiber Fiber
Mechanical Data
NOMINAL DIAMETER NOMINAL WEIGHT MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS
FIBER CORE
AFL NO.
COUNT GEOMETRY
INCHES MM LBS/1000FT KG/KM INSTALLATION OPERATION INSTALLATION OPERATION
FSU01-AP-2.0 1 1 with 7 fillers 0.299 2.0 3 4.1 10 (4.5) 5 (2.3) 4 (10) 2 (5)
FSU02-AP-2.0 2 2 with 6 fillers 0.299 2.0 3 4.1 10 (4.5) 5 (2.3) 4 (10) 2 (5)
FSU04-AP-2.0 4 4 with 4 fillers 0.299 2.0 3 4.1 10 (4.5) 5 (2.3) 4 (10) 2 (5)
FSU06-AP-2.0 6 6 with 2 fillers 0.299 2.0 3 4.1 10 (4.5) 5 (2.3) 4 (10) 2 (5)
FSU08-AP-2.0 8 8 with 0 fillers 0.311 2.0 3 4.1 10 (4.5) 5 (2.3) 4 (10) 2 (5)
FSU12-AP-2.5 12 12 with 0 fillers 0.311 2.5 4 6.5 10 (4.5) 5 (2.3) 4 (10) 2 (5)
Temperature Specifications
TEMPERATURE RANGE
INSTALLATION -30ºC to +70ºC
OPERATING -50ºC to +70ºC
STORAGE -50ºC to +75ºC
www.AFLglobal.com or (800) 235-3423 © 2013, AFL, all rights reserved. PP-1-00041, Revision 3, 12.14.15
Specifications are subject to change without notice.
43
eABF Solutions
eABF Cable
At the heart of the eABF solution is the cable and the duct. The eABF cable has been designed to offer exceptional air-jetting
qualities yet rugged enough to comply with Telcordia’s GR-409 Premise Cabling standard and NEC Riser and Plenum flame
ratings even outside of the MicroDuct. As a result, the cable can be deployed once exiting the pathway without the need for
additional costly furcation tubing as required by other less robust alternatives. The cable is available in fiber counts from six
through 72 with all fiber types including SMF, OM2, OM3 and OM4, and employs bend-insensitive fiber technology.
eABF MicroDuct
The eABF pathway system is comprised of Enterprise FuturePath® MicroDuct products engineered and produced by Dura-Line,
the premier communications-oriented fiber optic duct system. The eABF duct options include indoor/outdoor riser, plenum,
low-smoke zero halogen (LSZH) and HDPE product lines. All eABF ducts incorporate low-contact ribbed inner surface and ultra-
low friction Silicore®. The eABF FuturePath MicroDuct comes in tube counts from two through 24.
System
AFL and Dura-Line have joined together to produce a high-performance blown fiber optic cabling system with applications
across a broad spectrum of networking configurations. The solution, eABF (Enterprise Blown Fiber) cabling system is
engineered to offer a reliable, easy-to-install optical fiber network communications infrastructure that has one of the highest
fiber density solutions in the blown fiber market. The eABF solution has all the key elements that, when combined, yield a
state-of-the-art and highly flexible “living” communications pathway.
AFLglobal.com or 800-866-7385 © 2013, AFL, all rights reserved. PP-1-00037, Revision 4, 10.14.15
Specifications are subject to change without notice.
Duraline.com or 800-847-7661 44
eABF Solutions
CABLES
Enterprise Blown Cable (6-72 fibers)
Specifically designed for air-jetting applications through MicroDuct pathways. The proprietary high-drag, light-weight
design yields a cable that performs well during installation and yet offers a very robust and compact package for direct
routing through congested point-of-termination cable management locations. These cables are GR-409 compliant and
come in OFNP and OFNR ratings.
MICRODUCT SYSTEMS
Enterprise FuturePath
Enterprise FuturePath is available in many sizes and configurations including riser, plenum and LSZH. MicroDuct sizes
include 12.7 mm, 8.5 mm and 5 mm to accommodate your fiber requirements. Configurations from single MicroDucts to 24
pathways allow for rapid deployment of fiber today with permanent pathways in place for future growth.
OSP FuturePath
OSP FuturePath is available in many sizes and configurations for outside plant network installations. The same broad range
of MicroDuct options found in the Enterprise products plus a large range of inner duct sizes are available. All FuturePath
products come in armored and non-armored designs.
Field-Installable Connectors
FASTConnect®: Factory pre-polished, field-installable connectors that completely eliminate the need for hand polishing in
the field.
FUSEConnect®: With a factory pre-polished ferrule, its innovative field-termination process eliminates polishing, adhesives
and crimping in the field, minimizing the potential for operator error and expensive connector scrap.
AFLglobal.com or 800-866-7385 © 2013, AFL, all rights reserved. PP-1-00037, Revision 4, 10.14.15
Specifications are subject to change without notice.
Duraline.com or 800-847-7661 45
Fiber Optic Cable
Features Applications
• Plenum NFPA 262 Rated • Building Interconnections
• lSZH cables compliant to IEC60332, • Data Centers and Central Offices
IEC60754, and IEC61034 • Anywhere MTP connections can be used
• Tested to meet or exceed GR-409-CORE • High Density Interconnects
• Compliant to Directive 2002/95/EC (RoHS) • 40gbit and 100gbit Ethernet Architecture
• 2.0 mm or 3.0 mm Outer Diameter for
Round Boot 12-count MTP Cables
Temperature Specifications • 3.0 mm or 3.8 mm Outer Diameter
TEMPERATURE RANGE for Round Boot 24-count MTP Cables
INSTALLATION 0ºC to +70ºC • 4.8 mm Outer Diameter for Round Boot
OPERATING 0ºC to +70ºC
48-count MTP Cables
STORAGE -40ºC to +75ºC
• Exceptional skew performance
Cable Components
coated fiber aramid yarn
aramid yarn coated fiber
outer jacket outer jacket
string binder
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
www.AFLglobal.com or (800) 235-3423 © 2008, AFL, all rights reserved. PP-1-00056, Revision 5, 1.15.16
Specifications are subject to change without notice.
46
Fiber Optic Cable
Simplex SP008301#0B SE008301#0B 8 0.12 (3.0) 5.8 (8.6) 50 (222) 17 (76) 1.8 (4.5) 1.2 (3.0)
SP012301#0B SE012301#0B 12 0.12 (3.0) 6.0 (9.0) 50 (222) 17 (76) 1.8 (4.5) 1.2 (3.0)
SP016381#0B SE016381#0B 16 0.15 (3.8) 9.6 (15.4) 100 (445) 33 (147) 2.2 (5.7) 1.5 (3.8)
SP024381#0B SE024381#0B 24 0.15 (3.8) 13.2 (19.6) 100 (445) 33 (147) 2.2 (5.7) 1.5 (3.8)
SP048481#0B SE048481#0B 48 0.19 (4.8) 26.4 (40.0) 100 (445) 33 (147) 2.8 (7.2) 1.9 (4.8)
Zipcord ZP016301#0B ZE016301#0B 16 0.12 (3.0) 11.8 (17.6) 100 (445) 33 (147) 1.8 (4.5) 1.2 (3.0)
ZP024301#0B ZE024301#0B 24 0.12 (3.0) 12.4 (18.4) 100 (445) 33 (147) 1.8 (4.5) 1.2 (3.0)
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
www.AFLglobal.com or (800) 235-3423 © 2008, AFL, all rights reserved. PP-1-00056, Revision 5, 1.15.16
Specifications are subject to change without notice.
47
Fiber Optic Cable
Simplex Cable
Simplex fiber optic cables provide the strength and flexibility required for today’s fiber
interconnect applications. AFL offers the broadest selection of simplex cordage including
Plenum, Riser and LSZH, available in all diameters. Our simplex cable is tested to meet
Telcordia GR-326 when used in connectorized assemblies. AFL provides customized
performance with regard to jacket stiffness and flexibility, diameter, print legend, jacket
color and tight buffer strippability. The easy strip option allows removal of up to one
meter of 900 µm material without stripping the fiber’s 250 µm coating. Compliant with
Directive 2002/95/EC (RoHS).
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00063, Revision 4, 12.14.15
Specifications are subject to change without notice.
48
Fiber Optic Cable
Simplex Cable
Mechanical Data
NOMINAL WEIGHT TENSION BENDING RADIUS
FIBER DIAMETER RISER PLENUM LBS (N) INCHES (CM)
AFL NO. COUNT INCHES LBS/1000 FT LBS/1000 FT INSTALLATION LONG TERM INSTALLATION LONG TERM
(MM) (KG/KM) (KG/KM)
PLENUM SP001301#01 1 0.11 (2.9) — 6 (9) 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
SP001241#01 1 0.09 (2.4) — 5 (7) 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
SP001201#01 1 0.08 (2.0) — 3 (5) 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
SP001161#01 1 0.06 (1.6) — 2 (3) 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
RISER SA001301#01 1 0.11 (2.9) 5 (7) — 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
SR001241#01 1 0.09 (2.4) 3 (5) — 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
SR001201#01 1 0.08 (2.0) 3 (4) — 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
SR001161#01 1 0.06 (1.6) 2 (2) — 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
LSZH SE001301#0E 1 0.11 (2.9) 5 (7) — 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
SE001241#0E 1 0.09 (2.4) 3 (5) — 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
SE001201#0E 1 0.08 (2.0) 3 (4) — 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
* Add suffix "– XMFBOX" to cable AFL number to specify "Fiber-In-A-Box" solution. "X" indicates length of cable in thousands of feet. Only available in standard lengths as
indicated in chart above.
EXAMPLE: SP0019301001–3MFBOX
Would be the resulting AFL number for 3,000 feet of SP001*301001 cable with 9/125 µm single-mode fiber and the Fiber-In-A-Box solution.
Refer to Fiber-In-A-Box data sheet.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00063, Revision 4, 12.14.15
Specifications are subject to change without notice.
49
Fiber Optic Cable
Features
• Print legend customization • Tested to meet or exceed EIA/TIA
Applications • Jacket color (12 standard colors available) 568-133 and Telcordia GR-409-CORE
• Communications closet to wall outlet • Tight Buffer strippability (easy strip • LSZH meets the requirements of
• Wall outlet to desk option allows removal of up to 1 meter IEC 61034-1, 61034-2, 60332-1-1,
• Connectorized patchcords for intercon- of 900 µm material without stripping 60332-1-2, 60754-1, 60754-2
nect and cross-connect applications the fiber’s 250 µm coating) • Compliant to Directive 2002/95/EC
• Easy interface to ESCON®, FDDI, and • Ruggedized Duplex designs for transport (RoHS)
various other duplex connectors from communications closet to wall outlet
Cable Components
Zipcord DUAL-Link Micro-Dual Ruggedized Duplex
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00067, Revision 5, 12.14.15
Specifications are subject to change without notice.
50
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
* Add suffix "– XMFBOX" to cable AFL number to specify "Fiber-In-A-Box" solution. "X" indicates length of cable in thousands of feet. Only available in standard lengths as
indicated in chart above. EXAMPLE: ZA0029301001–3MFBOX would be the resulting AFL number for 3,000 feet of ZA002*301001 cable with 9/125 µm single-mode
fiber and the Fiber-In-A-Box solution. Refer to Fiber-In-A-Box data sheet.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00067, Revision 5, 12.14.15
Specifications are subject to change without notice.
51
Fiber Optic Cable
Features
• Standard diameters
• Product is un-printed by defualt; Custom Print Legend available
• Smooth fiber insertion
• Low Shrinkage for superior resistance to aging and high temperatures
• Ferrule adherence tested using industry standard adhesives
• Compliant to Directive 2002/95/EC (RoHS)
• LSZH meets the requirements of IEC 61034-1, 61034-2, 60332-1-1, 60332-1-2,
60754-1, 60754-2
Applications
• Ribbon and Trunk cable fan-out to
single fiber connections
Tubing Components
www.AFLglobal.com or (800) 235-3423 © 2005, AFL, all rights reserved. PP-1-00049, Revision 5, 12.14.15
Specifications are subject to change without notice.
52
Fiber Optic Cable
Temperature Specifications
TEMPERATURE RANGE
INSTALLATION -20ºC to +70ºC
OPERATING -20ºC to +70ºC
STORAGE -40ºC to +70ºC
www.AFLglobal.com or (800) 235-3423 © 2005, AFL, all rights reserved. PP-1-00049, Revision 5, 12.14.15
Specifications are subject to change without notice.
53
Fiber Optic Cable
RIBBON-Link® Cable
RIBBON-Link cables combine high fiber density in a small diameter, flexible package. These
cables can be terminated with 12 or 24 fiber multi-fiber connectors or the fibers can be
fanned out and terminated individually. Plenum, Riser and LSZH options are all UL listed.
Features Applications
• Fiber counts up to 48 with unitized, zip • Direct interface to computers with the use
configuration construction of “backplane” style fiber connectors
• Maximum of two 12-fiber ribbons per unit • High density interconnection to wall
• Skew matched ribbons available (<10, outlets or patch panels with ribbon
<6, <5, <4, <3, <2, <1.2 ps/meter) connector interfaces
• Easy interface to MT and MTP based • “Micro-diameter” fanout cables utiliz-
connectors as well as today’s newest ing standard industry fiber connectors
ribbon connectors (12- or 24-fiber (ST, SC, FC, LC, MT-RJ.)
ferrules) • VSR OC-192/OC-768 Interface based
• Ruggedized versions with additional on parallel fiber optics
jacketing are available
• Tested to meet or exceed EIA/TIA
568-A / GR-409-CORE
• Compliant to Directive 2002/95/EC
(RoHS)
Cable Components
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00062, Revision 3, 12.14.15
Specifications are subject to change without notice.
54
Fiber Optic Cable
RIBBON-Link® Cable
Mechanical Data
NOMINAL TENSION BENDING RADIUS
AFL NO. DIAMETER WEIGHT LBS (N) INCHES (CM)
CABLE FIBER
TYPE COUNT LBS/
PLENUM PLENUM INCHES 1000 FT INSTALLA- LONG INSTALLA- LONG
RISER LSZH
(PVDF) (PVC) (MM) (KG/ TION TERM TION TERM
KM)
RIBBON- 4 0.08 x 0.16
Link WP004141#12 WK004141#12 WR004141#12 WE004141#12 7.5 (11) 22 (100) 7 (30) 2.4 (6.0) 1.6 (4.0)
(2.1 x 4.0)
(single 0.08 x 0.16
pod) WP006161#12 WK006161#12 WR006161#12 WE006161#12 6 7.5 (11) 22 (100) 7 (30) 2.4 (6.0) 1.6 (4.0)
(2.1 x 4.0)
8 0.08 x 0.16
WP008181#12 WK008181#12 WR008181#12 WE008181#12 7.5 (11) 22 (100) 7 (30) 2.4 (6.0) 1.6 (4.0)
(2.1 x 4.0)
12 0.08 x 0.18
WP0121C1#12 WK0121C1#12 WR0121C1#12 WE0121C1#12 8 (12) 22 (100) 7 (30) 2.7 (6.9) 1.8 (4.6)
(2.1 x 4.6)
24 0.10 x 0.18
WP0241D1#12 WK0241D1#12 WR0241D1#12 WE0241D1#12 8.7 (13) 22 (100) 7 (30) 2.7 (6.9) 1.8 (4.6)
(2.5 x 4.6)
RIBBON- — 8 0.08 x 0.32
WP008241#12 WR008241#12 WE008241#12 15 (22) 22 (100) 7 (30) 2.4 (6.0) 1.6 (4.0)
LINK (2.1 x 8.2)
(dual- 0.08 x 0.32
pod) WP012261#12 — WR012261#12 WE012261#12 12 15 (22) 22 (100) 7 (30) 2.4 (6.0) 1.6 (4.0)
(2.1 x 8.2)
0.08 x 0.32
WP016281#12 — WR016281#12 WE016281#12 16 (2.1 x 8.2) 15 (22) 22 (100) 7 (30) 2.4 (6.0) 1.6 (4.0)
— 24 0.08 x 0.36
WP0242C1#12 WR0242C1#12 WE0242C1#12 15 (24) 22 (100) 7 (30) 2.7 (6.9) 1.8 (4.6)
(2.1 x 9.2)
ROUND WP002301#12 — WR002301#12 WE002301#12 2 0.11 (2.9) 5 (7) 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
RIBBON
(simplex) WP004301#12 — WR004301#12 WE004301#12 4 0.11 (2.9) 5 (7) 22 (100) 7 (30) 2.0 (5.0) 1.2 (3.0)
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00062, Revision 3, 12.14.15
Specifications are subject to change without notice.
55
Fiber Optic Cable
Fiber-In-A-Box
AFL’s "Fiber-In-A-Box" solution offers contractors lightweight, easy to use cable pack-
aging with "out of the box" disbursement of fiber cable. No reel supports or pay-off's
are required. Simply set the box down in a convenient place, unlock the built-in braking
mechanism and begin pulling. Adjust the braking mechanism to apply the amount of pulling
tension required. Stack and configure boxes together to disburse cable from several reels at
the same time. Available in lengths of 1000, 2000 and 3000 feet, this unique cable package
solution will save contractors valuable time and cost.
Features/Benefits
• Easy count printing – descending marks (feet or meters) indicating amount of cable
remaining on reel
• Light weight and easy to transport with grips on both sides of the box for easy handling
• Eliminates the need for reel supports and cable spooling equipment
• Unique braking mechanism allows reel to be locked in place within carton during
transport and provides control of tension during cable pulls
• Boxes can be stacked and configured to support easy pay-off of multiple cable runs
• Wording under feed-through slot reminds installers of proper pulling methods for
optical cable
• Factory packaging ensures cable is not "over-stressed" in non-factory cable cutting
operations where personnel may not be sensitive to proper handling of fiber optic cable
• Available in lengths of 1000, 2000 and 3000 feet, depending on cable diameter
• Easy access to reel from top allows installers to repackage excess cable removed from box
• Easy way to organize, store and manage short lengths of excess cable
Applications
• Horizontal cabling / Fiber-to-the-Desk
• Fiber Drops within MDUs
• Short-to-medium length cable runs between buildings
Ordering Information
Add suffix "-XMFBOX" to part number to specify "Fiber-In-A-Box" solution
where X indicates length of the cable in thousands of feet (1, 2, or 3).
www.AFLglobal.com or (800) 235-3423 © 2006, AFL, all rights reserved. PP-1-00048, Revision 3, 10.10.11
Specifications are subject to change without notice.
56
Fiber Optic Cable
Applications Features
• Connectorized communications cables • Tested to meet or exceed EIA/TIA 568-A/
with both send-and-receive and send- GR-409-CORE
and-receive backup in a single unit • Compliant to Directive 2002/95/EC (RoHS)
• Routing between communications • Mixed fiber designs available
closets and equipment rooms
• Intrabuilding backbones
Cable Components
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN. MIN. LINK DISTANCE ETHERNET MIN. LINK
CORE SIZE/ (DB/KM) BANDWIDTH EMBc
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00061, Revision 5, 12.14.15
Specifications are subject to change without notice.
57
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
* Add suffix "– XMFBOX" to cable AFL number to specify "Fiber-In-A-Box" solution. "X" indicates length of cable in thousands of feet. Only available in standard lengths as
indicated in chart above.
EXAMPLE: UA0049481001–3MFBOX
Would be the resulting AFL number for 3,000 feet of UA004*481001 cable with 9/125 µm single-mode fiber and the Fiber-In-A-Box solution.
Refer to Fiber-In-A-Box data sheet.
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00061, Revision 5, 12.14.15
Specifications are subject to change without notice.
58
Fiber Optic Cable
Applications Features
• Head-end termination to a fiber • Tested to meet or exceed EIA/TIA 568-A
"backbone" / GR-409-CORE
• Termination of fiber rack systems • Compliant to Directive 2002/95/EC
• Multi-floor deployment where select (RoHS)
fibers are used at each floor • Hybrid constructions are available
• Intrabuilding "backbones"
Cable Components
Temperature Specifications
TEMPERATURE RANGE
PLENUM RISER
INSTALLATION 0ºC to +70ºC -20ºC to +70ºC
OPERATING 0ºC to +70ºC -20ºC to +70ºC
STORAGE -40ºC to +75ºC -40ºC to +75ºC
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00060, Revision 4, 12.14.15
Specifications are subject to change without notice.
59
Fiber Optic Cable
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00060, Revision 4, 12.14.15
Specifications are subject to change without notice.
60
Fiber Optic Cable
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
A
www.AFLglobal.com or (800) 235-3423 © 2012, AFL, all rights reserved. PP-1-00058. Revision 2, 12.14.15
Specifications are subject to change without notice.
61
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
* Add suffix "– XMFBOX" to cable AFL number to specify "Fiber-In-A-Box" solution. "X" indicates length of cable in thousands of feet. Only available in standard lengths as
indicated in chart above.
EXAMPLE: CE0049481001–3MFBOX
Would be the resulting AFL number for 3,000 feet of CE004*481001 cable with 9/125 µm single-mode fiber and the Fiber-In-A-Box solution.
Refer to Fiber-In-A-Box data sheet.
A
www.AFLglobal.com or (800) 235-3423 © 2012, AFL, all rights reserved. PP-1-00058. Revision 2, 12.14.15
Specifications are subject to change without notice.
62
Fiber Optic Cable
Applications
• Routing inside of buildings where additional ruggedness is required or where increased
rodent resistance is required
• Extra protection for fiber optic cables in harsh industrial environments
• Manufacturing plants
• High-density routings in data center applications
Ruggedized Indoor/Outdoor Breakout Cable • Approved for use in mining applications
• For cables that can be armored, look for the armor shileld icon A
Cable Components
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00039, Revision 4, 11.14.12
Specifications are subject to change without notice.
63
Fiber Optic Cable
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00039, Revision 4, 11.14.12
Specifications are subject to change without notice.
64
Fiber Optic Cable
Applications
• Routing inside of buildings where additional ruggedness is required
or where increased rodent resistance is required
• Extra protection for fiber optic cables in harsh industrial environments
• Manufacturing plants
• High-density routings in data center application
Cable Components
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00039, Revision 5, 12.14.15
Specifications are subject to change without notice.
65
Fiber Optic Cable
CR024441001-AIAR CP024441001-AIAP 24 0.84 (21.3) 247 (367) 273 (407) 300 (1320) 90 (396) 150 (660) 45 (198) 7.9 (20.0) 5.2 (13.3)
CR036551001-AIAR CP036551001-AIAP 36 0.94 (24) 256 (395) 294 (439) 300 (1320) 90 (396) 150 (660) 45 (198) 14.2 (36.0) 9.4 (24.0)
CR048551001-AIAR CP048551001-AIAP 48 0.94 (24) 256 (395) 294 (439) 300 (1320) 90 (396) 150 (660) 45 (198) 14.2 (36.0) 9.4 (24.0)
CR072551001-AIAR CP072551001-AIAP 72 1.10 (27.9) 355 (530) 401 (597) 300 (1320) 90 (396) 150 (660) 45 (198) 16.5 (41.9) 11.0 (27.9)
CR096551001-AIAR CP096551001-AIAP 96 1.21 (30.7) 472 (705) 507 (755) 300 (1320) 90 (396) 150 (660) 45 (198) 18.1 (46.1) 12.1 (30.7)
CR144551001-AIAR CP144551001-AIAP 144 1.37 (34.8) 498 (742) 534 (796) 300 (1320) 90 (396) 150 (660) 45 (198) 19.8 (50.3) 13.2 (33.5)
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00039, Revision 5, 12.14.15
Specifications are subject to change without notice.
66
Fiber Optic Cable
Applications Features
• In-building cable runs where space • Plenum NFPA 262 rated • No preferential bend typically found
is a premium • Riser UL 1666 rated in stacked ribbon designs
• Trunk applications where flexibility and • LSZH performance verified to IEC • Small diameter/superior
small required bend radius are needed 60754-2, 61034-2 and 60332-3-24 bend performance
to route cable. • Tested to meet or exceed EIA/TIA • All aramid tensile strength members
• High density cable areas like 568-B3, Telcordia GR-409-CORE within sub-units
Data Centers and Central Offices and ANSI/ICEA S-83-596 • Sub-units are suitable for direct
• Lower cost cable runs where easy • Flexible dielectric FRP central strength termination with round boot MTP
handling of tight buffered fibers not member in four position, 24 fiber • Compliant to Directive
needed because cable will be spliced designs and higher 2002/95/EC (RoHS)
to factory terminated pigtails • High performance fluoropolymer,
• Trunk cables where MTP can be directly PVC or LSZH outer jackets available
terminated on subunits
center member
sub-unit center member sub-unit
outer jacket sub-unit flexible
flexible outer jacket
aramid yarn for outer jacket
pull strength
ripcord
ripcord
center member
center member center member
sub-unit sub-unit
flexible sub-unit flexible
outer jacket outer jacket
flexible
outer jacket
ripcord
ripcord
ripcord
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
A
www.AFLglobal.com or (800) 235-3423 © 2006, AFL, all rights reserved. PP-1-00065, Revision 7, 12.14.15
Specifications are subject to change without notice.
68
Fiber Optic Cable
72 fiber 72 fiber 72 fiber 96 fiber 96 fiber 96 fiber 144 fiber 144 fiber 144 fiber
27% Reduction in 72ct Cable Diameter Yields Over 100% Increase in Pathway Capacity
30% Reduction in 72ct Cable Diameter Yields 100% Increase in Pathway Capacity
A
Next Generation Sub-unitized
(800) 235-3423
www.AFLglobal.com or MicroCore 2.0 Cable in Tray © 2013, AFL, all rights reserved. PP-1-00095, Revision 3, 12.14.15
250 x 72ct cables in standard 4"X 12" tray Specifications are subject to change without notice.
69
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
A
www.AFLglobal.com or (800) 235-3423 © 2013, AFL, all rights reserved. PP-1-00095, Revision 3, 12.14.15
Specifications are subject to change without notice.
70
Fiber Optic Cable
NEW
SWR Technology
Sub-unitized Premise MicroCore®
with SpiderWeb® Ribbon (SWR®) Technology
The third generation of our Sub-Unitized Premise MicroCore cables is another astounding
evolution of high performance premise cabling. Enabling even greater pathway density
than our 2.0 version, the 3.0 revolutionizes cable deployment and allows the end
user to realize savings in space, routing infrastructures and fiber management.
Combining the highest quality materials with rigorous testing to industry standards,
this generation builds on the same quality of construction as the previous versions of our
Sub-Unitized Premise MicroCore cables. Also similar to previous version is the employment
of stand-alone sub cables. Each sub-cable is independently qualified and is suitable for
individual routing paths within the rack/panel architecture. This flexibility of design and
deployment is not available in comparable high density designs. Designed for direct
termination, and supportive of both single-fiber and multi-fiber architectures, this cable family
is capable of serving as the backbone in any deployed system.
SpiderWeb Ribbon (SWR) is a bonded fiber design allowing for either a highly efficient
ribbonizing application or for individual fiber break-outs. This flexibility allows for the
application of a single cable design to cover a diverse set of applications. High density
round designs allow for the most efficient use of space and materials, resulting in a cost
effective solution.
SpiderWeb Ribbon Technology
24, 48, 72
120 and 144 Fiber
and 96 Fiber
168, 192, 216, 240,
264 and 288 Fiber
A
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00112, Revision 11, 3.30.15
Specifications are subject to change without notice.
71
Fiber Optic Cable
Fiber Types – Replace diamond () in AFL number with number in the Fiber Specifications table below
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
A
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00112, Revision 11, 3.30.15
Specifications are subject to change without notice.
72
Fiber Optic Cable
Breakout Cable
Breakout cables combine multiple fiber flexibility with the strength of individually
jacketed fibers. Breakout cables from AFL can be terminated for fanout assemblies.
Breakout cable is available in counts of 2-24 fibers.
Features
• Sub-units printed every 6 inches
• Tested to meet or exceed
EIA/TIA 568-A / GR-409-CORE
• Compliant to Directive
2002/95/EC (RoHS)
• MSHA approved for mining applications
• Tight buffer and sub-unit jacket are
available in a variety of colors
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
Temperature Specifications
TEMPERATURE RANGE
INSTALLATION 0ºC to +70ºC
OPERATING 0ºC to +70ºC
STORAGE -40ºC to +75ºC
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00044, Revision 4, 12.14.15
Specifications are subject to change without notice.
73
Fiber Optic Cable
Breakout Cable
Mechanical Data
NOMINAL TENSION BENDING RADIUS
FIBER DIAMETER WEIGHT LBS (N) INCHES (CM)
CABLE TYPE AFL NO. COUNT INCHES (MM) LBS/1000FT (KG/KM) INSTALLATION LONG TERM INSTALLATION LONG TERM
Riser Breakout Cable BR004241#01 4 0.33 (8.5) 44 (65) 150 (660) 45 (198) 5.1 (12.8) 3.4 (8.5)
BR006241#01 6 0.40 (10.1) 64 (95) 150 (660) 45 (198) 6.0 (15.2) 4.0 (10.1)
BR008241#01 8 0.46 (11.6) 84 (125) 150 (660) 45 (198) 6.9 (17.4) 4.6 (11.6)
BR012241#01 12 0.58 (14.7) 138 (205) 150 (660) 45 (198) 8.7 (22.1) 5.8 (14.7)
BR024241#01 24 0.65 (16.6) 118 (175) 300 (1320) 90 (396) 11.4 (29.0) 7.6 (19.3)
Plenum Breakout Cable BP004301#01 4 0.36 (9.0) 57 (85) 100 (440) 30 (132) 5.3 (13.5) 3.6 (9.0)
BP006301#01 6 0.42 (10.6) 79 (118) 100 (440) 30 (132) 6.3 (15.9) 4.2 (10.6)
BP008301#01 8 0.48 (12.2) 105 (156) 100 (440) 30 (132) 7.2 (18.3) 4.8 (12.2)
BP012301#01 12 0.61 (15.5) 169 (252) 100 (440) 30 (132) 9.2 (23.2) 6.1 (15.5)
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00044, Revision 4, 12.14.15
Specifications are subject to change without notice.
74
Fiber Optic Cable
A
www.AFLglobal.com or (800) 235-3423 © 2013, AFL, all rights reserved. PP-1-00040, Revision 1, 12.14.15
Specifications are subject to change without notice.
75
Fiber Optic Cable
A
www.AFLglobal.com or (800) 235-3423 © 2013, AFL, all rights reserved. PP-1-00040, Revision 1, 12.14.15
Specifications are subject to change without notice.
76
Fiber Optic Cable
For indoor applications the cable is OFNR listed. For outdoor applications the cable is
manufactured with an outer jacket that incorporates a UV stabilizer for protection against
exposure to the sun plus an anti-fungus protection for use in underground applications.
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00055, Revision 4, 12.14.15
Specifications are subject to change without notice.
77
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
* Add suffix "– XMFBOX" to cable AFL number to specify "Fiber-In-A-Box" solution. "X" indicates length of cable in thousands of feet. Only available in standard lengths as
indicated in chart above.
EXAMPLE: KR0029481001–3MFBOX
Would be the resulting AFL number for 3,000 feet of KR002481001 cable with 9/125 µm single-mode fiber and the Fiber-In-A-Box solution.
Refer to Fiber-In-A-Box data sheet.
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00055, Revision 4, 12.14.15
Specifications are subject to change without notice.
78
Fiber Optic Cable
Indoor/Outdoor Multi-unit
Riser Tight Buffered Cable
AFL now offers high fiber count Indoor/Outdoor Riser Cables. Waterblocked 12-fiber
sub-units are helically stranded to provide sub-unitized cables ranging from 24 to 72 fiber
counts. These cables are OFNR listed for indoor applications. Both the sub-unit jackets and
outer sheath contain a UV stabilizer and anti-fungus protection for use in outdoor
applications. Sub-units contain a water-swellable aramid and 12 tight buffered fibers.
Features
• Sub-units are water blocked and meet • With a Riser rating, this cable can be
water penetration requirements of used in all environments: Riser, general
GR-20-CORE (this helps ensure inside plant and outside plant
that any damage to cable is restricted • Sub-units are tested to meet or exceed
to a repairable length of several meters) EIA/TIA 568-A / GR-409-CORE and
• Outer jacket is moisture-resistant, ICEA-S-104-696
fungus-resistent and UV resistant for • Compliant to Directive 2002/95/EC (RoHS)
outdoor use • MSHA approved for mining applications
Cable Components
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
Temperature Specifications
TEMPERATURE RANGE
INSTALLATION -20ºC to +75ºC
OPERATING -40ºC to +75ºC
STORAGE -40ºC to +75ºC
A
www.AFLglobal.com or (800) 235-3423 © 2008, AFL, all rights reserved. PP-1-00052, Revision 3, 12.14.15
Specifications are subject to change without notice.
79
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
A
www.AFLglobal.com or (800) 235-3423 © 2008, AFL, all rights reserved. PP-1-00052, Revision 3, 12.14.15
Specifications are subject to change without notice.
80
Fiber Optic Cable
Indoor/Outdoor
Plenum Distribution Cable
Indoor/Outdoor Plenum Distribution cables are specified for campus network cabling
between buildings where interbuilding lengths are short enough that the installer can
recognize savings from the lower costs of terminating tight buffered cables.
For indoor applications the cable is OFNP listed. For outdoor applications the cable is
manufactured with an outer jacket that incorporates a UV stabilizer for protection against
exposure to the sun plus an anti-fungus protection for use in underground applications.
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
Temperature Specifications
TEMPERATURE RANGE
INSTALLATION -10ºC to +70ºC
OPERATING -40ºC to +70ºC
STORAGE -40ºC to +70ºC
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00124, Revision 2, 12.14.15
Specifications are subject to change without notice.
81
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
* Add suffix "– XMFBOX" to cable AFL number to specify "Fiber-In-A-Box" solution. "X" indicates length of cable in thousands of feet. Only available in standard lengths as
indicated in chart above.
EXAMPLE: KQ0029541001–1MFBOX
Would be the resulting AFL number for 3,000 feet of KQ002*541001 cable with 9/125µm single-mode fiber and the Fiber-In-A-Box solution.
Refer to Fiber-In-A-Box data sheet.
A
www.AFLglobal.com or (800) 235-3423 © 2002, AFL, all rights reserved. PP-1-00124, Revision 2, 12.14.15
Specifications are subject to change without notice.
82
Fiber Optic Cable
Features Applications
• Fungus, water and UV-resistant PVC • Harsh Environment
jacket featuring SP extrusion technology • Mining
• Riser-rated with water-blocked sub-units • Industrial
• Sub-units and tight buffer available in a • Campus Environment
variety of colors
• Tested to meet or exceed GR-409-CORE
and ICEA-S-104-696
• Compliant to Directive
2002/95/EC (RoHS)
Cable Components • MSHA approved for mining applications
2-Fiber 12-Fiber
PVC outer jacket PVC outer jacket
2.4 mm water-blocked simplex sub-unit 2.5 mm simplex sub-unit
- 900 µm buffered fiber - 900 µm buffered fiber
- water swellable aramid yarn strength members - water swellable aramid yarn strength members
- PVC jacket - PVC jacket
strength member (2) upjacketed FRP center strength member
ripcord ripcord
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 3.0
PVC outer jacket
OM2 1.2 N/A 700 500 950 PVC outer800
jacket 550 150 —
2.4 mm water-blocked simplex sub-unit 2.5 mm simplex sub-unit
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
- 900 µm buffered fiber - 900 µm buffered fiber
(C) 50 Laser-Link 550 3.0 aramid 1.2
OM4- water swellable N/A
yarn strength members 3500 550 4700 1040 550 550
- water swellable aramid yarn strength members —
(K) AFL G.657.A1 Single-mode OS2- PVC jacket
N/A 0.5 0.5 N/A N/A N/A N/A
- PVC jacket 5000 N/A 10,000
(9) SM strength member
OS2 N/A (2) 0.5 0.5 N/A N/A N/A upjacketedN/A
FRP center strength
5,000member N/A 10,000
ripcord ripcord
Temperature Specifications
TEMPERATURE RANGE
INSTALLATION -20ºC to +70ºC
OPERATING -40ºC to +70ºC
STORAGE -40ºC to +70ºC
A
www.AFLglobal.com or (800) 235-3423 © 2008, AFL, all rights reserved. PP-1-00051, Revision 4, 12.14.15
Specifications are subject to change without notice.
83
Fiber Optic Cable
A
www.AFLglobal.com or (800) 235-3423 © 2008, AFL, all rights reserved. PP-1-00051, Revision 4, 12.14.15
Specifications are subject to change without notice.
84
Fiber Optic Cable
Ruggedized Indoor/Outdoor
Breakout Cable
AFL Ruggedized Indoor/Outdoor Riser Breakout cable is suited for applications requiring
a high performance fiber optic cable. Water-blocked and re-inforced with all-dielectric
strength members within the core, this cable can withstand the rigors presented by
higher end installations. Available in 2-12 fiber counts, these cables feature a UV-and
Fungal-Resistant semi-pressure extrueded outer jacket. Individual sub-units measure
2.5 mm, allowing for ease of field termination. Sub-units are also water-blocked adding
to the overall protection of the fiber optic components from environmental damage.
Features Applications
• Fungus, water and UV-resistant PVC • Harsh Environment
jacket featuring SP extrusion technology • Mining
• Riser-rated with water-blocked sub-units • Industrial
Temperature Specifications • Sub-units and tight buffer available • Campus Environment
in a variety of colors
TEMPERATURE RANGE
INSTALLATION -20ºC to +70ºC • Tested to meet or exceed GR-409-CORE
OPERATING -40ºC to +70ºC and ICEA-S-104-696
STORAGE -40ºC to +70ºC • Compliant to Directive
2002/95/EC (RoHS)
• MSHA approved for mining applications
Cable Components
2 and 4 Fiber PVC outer jacket 12 Fiber PVC outer jacket
2.5mm water-blocked simplex sub-unit 2.5mm simplex sub-unit
- 900µm buffered fiber - 900µm buffered fiber
- water swellable aramid yarn strength members - water swellable aramid yarn strength members
- PVC jacket - PVC jacket
aramid yarn strength member
strength member aramid yarn
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
A
www.AFLglobal.com or (800) 235-3423 © 2008, AFL, all rights reserved. PP-1-00081, Revision 2, 12.14.15
Specifications are subject to change without notice.
85
Fiber Optic Cable
A
www.AFLglobal.com or (800) 235-3423 © 2008, AFL, all rights reserved. PP-1-00081, Revision 2, 12.14.15
Specifications are subject to change without notice.
86
Fiber Optic Cable
Features Applications
• Cut resistant polyurethane jacket with • Field deployment in
flame retardant options available abusive environments
• Highly flexible construction allows • Temporary installation of critical
Temperature Specifications
for multiple deployments communications lines where quick
TEMPERATURE RANGE retrieval and re-use is necessary
INSTALLATION -46ºC to +85ºC
• All aramid strength members
• High Traffic areas
OPERATING -46ºC to +85ºC • Performance in wide temperature range
• Security and Sensing applications
STORAGE -55ºC to +85ºC • High impact and crush resistance
• Broadcast deployments
• Durable in high traffic areas
• Installations in harsh environments
• MIL-PRF-46291 qualified fiber
available (-RH designation)
• Tested to meet MIL-PRF-85045
Cable Components
Polyurethane outer jacket
Specifications
CHARACTERISTIC TEST PROCEDURE PERFORMANCE
Tensile and elongation EIA/TIA-455-33
Operating tensile strength EIA/TIA-455-33
Low-temp flexibility EIA/TIA-455-37
Cyclic flexing EIA/TIA-455-104 2000
Crush resistance EIA/TIA-455-41 1800 N/cm or greater
Impact EIA/TIA-455-25 200
Temperature cycling EIA/TIA-455-3 -46°C to 85°C
Temperature/humidity cycling EIA/TIA-455-5 Method B
Life aging EIA/TIA-455-4
Freezing water immersion EIA/TIA-455-98
www.AFLglobal.com or (800) 235-3423 © 2007, AFL, all rights reserved. PP-1-00066, Revision 5 1.20.16
Specifications are subject to change without notice.
87
Fiber Optic Cable
Mechanical Data
MAXIMUM TENSILE LOAD MINIMUM BEND RADIUS
FIBER NOMINAL DIA. NOMINAL WT.
AFL NO. LBS (N) INCHES (CM)
COUNT
INCHES (MM) LBS/1000FT (KG/KM) INSTALLATION LONG TERM INSTALLATION LONG TERM
XU00130180H-SH 1 0.12 (3.0) 5.4 (8) 135 (600) 40 (178) 1.8 (4.5) 1.2 (3.0)
XU00140180H-SH 1 0.16 (4.0) 9.1 (13.5) 180 (800) 54 (240) 2.4 (6.0) 1.6 (4.0)
XU00146180H-SH 1 0.18 (4.6) 12.2 (18.1) 180 (800) 54 (240) 2.7 (6.9) 1.8 (4.6)
XU00255180H-SH 2 0.22 (5.5) 16.2 (25) 400 (1780) 130 (578) 2.2 (5.5) 1.1 (2.8)
XU00455180H-SH 4 0.22 (5.5) 16.2 (25) 400 (1780) 130 (578) 2.2 (5.5) 1.1 (2.8)
XU00258180H-SH 2 0.23 (5.8) 21.5 (32) 400 (1780) 130 (578) 3.4 (8.7) 2.3 (5.8)
XU00458180H-SH 4 0.23 (5.8) 21.5 (32) 400 (1780) 130 (578) 3.4 (8.7) 2.3 (5.8)
XU00661180H-SH 6 0.24 (6.1) 22.2 (33) 400 (1780) 130 (578) 3.6 (9.2) 2.4 (6.1)
XU00864180H-SH 8 0.25 (6.4) 28.8 (44) 470 (2090) 160 (712) 2.5 (6.4) 1.3 (3.2)
XU01264180H-SH 12 0.25 (6.4) 30.8 (47) 470 (2090) 160 (712) 2.5 (6.4) 1.3 (3.2)
XU02485180H-SH 24 0.33 (8.5) 38.7 (59) 670 (2980) 220 (979) 3.3 (8.5) 1.7 (4.3)
Note: D iameter and weight subject to change without notice
For flame retardant jacket option remove the extension –SH from the item number
www.AFLglobal.com or (800) 235-3423 © 2007, AFL, all rights reserved. PP-1-00066, Revision 5 1.20.16
Specifications are subject to change without notice.
88
Fiber Optic Cable
Applications
• Field deployment in abusive environments • Sporting and media events
• High traffic areas • Temporary installation of critical
• Security and sensing applications communications lines where quick
• Broadcast deployments retrieval and re-use is necessary
• Installations in harsh environments
Mechanical Data
NOMINAL TENSION BENDING TEMPERATURE
DIAMETER WEIGHT LBS (N) RADIUS RANGE
FIBER LBS/1000 FT INCHES INSTALLA-
AFL NO. COUNT INCHES (MM) (KG/KM) INSTALLATION LONG TERM (CM) OPERATING TION STORAGE
XU00130180#-SH 1 .12 (2.9) 5.4 (8) 250 (1112) 66 (290) 1.2 (3.0)
XU00258180#-SH 2 .23 (5.8) 21.5 (32) 325 (1450) 66 (290) 2.3 (5.8)
XU00458180#-SH 4 .23 (5.8) 21.5 (32) 325 (1450) 66 (290) 2.3 (5.8) -46°C to 85°C -20°C to 85°C -57°C to 85°C
XU00661180#-SH 6 .24 (6.1) 21.5 (33) 325 (1450) 66 (290) 2.4 (6.1)
XU01270180#-SH 12 .28 (7.0) 31.7 (47) 394 (1750) 79 (350) 2.8 (7.0)
Note: Diameter and weight subject to change without notice Replace asterisk () in AFL number with number corresponding below.
5 = 50/125 µm multimode GIGA-Link™ 600 9 = Single-mode
6 = 62.5/125 µm multimode GIGA-Link™ 300 K = AFL G657.A1 Single-mode
* Other fiber types available.
Replace pound sign (#) in AFL number with number corresponding below.
G = 500 µm Coated Optical Fiber
H = 250 µm Coated Optical Fiber
www.AFLglobal.com or (800) 235-3423 © 2009, AFL, all rights reserved. PP-1-00045, Revision 2, 10.31.12
Specifications are subject to change without notice.
89
Fiber Optic Cable
Standards
4 Fiber
• Telcordia GR-409-CORE
• ICEA S-104-696
• MSHA approved
Fiber Specifications
OVERFILL LAUNCH GIGABIT ETHERNET 10 GIGABIT
MAXIMUM ATTENUATION MIN.
CORE SIZE/ EMBc MIN. LINK DISTANCE ETHERNET MIN. LINK
(DB/KM) BANDWIDTH
FIBER TYPE (MHZ•KM) (METERS) DISTANCE (METERS)
ISO/ (MHZ•KM)
IEC 850 NM 1300 NM 1550 NM 850 NM 1300 NM 850 NM 1300 NM 850 NM 1300 NM
(6) 62.5 Giga-Link™ 300 OM1 3.5 1.2 N/A 200 600 N/A 300 550 32 —
(5) 50 Giga-Link™ 600 OM2 3.5 1.5 N/A 500 500 N/A 600 600 82 —
(A) 50 Laser-Link 150 OM2 3.0 1.2 N/A 700 500 950 800 550 150 —
(L) 50 Laser-Link 300 OM3 3.0 1.2 N/A 1500 500 2000 1000 550 300 —
(C) 50 Laser-Link 550 OM4 3.0 1.2 N/A 3500 550 4700 1040 550 550 —
(K) AFL G.657.A1 Single-mode OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5000 N/A 10,000
(9) SM OS2 N/A 0.5 0.5 N/A N/A N/A N/A 5,000 N/A 10,000
Temperature Specifications
TEMPERATURE RANGE
INSTALLATION -20ºC to +70ºC
OPERATING -40ºC to +70ºC
STORAGE -40ºC to +70ºC
www.AFLglobal.com or (800) 235-3423 © 2010, AFL, all rights reserved. PP-1-00046, Revision 3, 12.14.15
Specifications are subject to change without notice.
90
Fiber Optic Cable
Fiber Types – Replace asterisk () in AFL number with number in the Fiber Specifications table on previous page.
# Outer Jacket Color – Replace hashtag (#) in AFL number with number in the Cable Jacket Color table below.
www.AFLglobal.com or (800) 235-3423 © 2010, AFL, all rights reserved. PP-1-00046, Revision 3, 12.14.15
Specifications are subject to change without notice.
91
Fiber Optic Cable
Installation Information
NESC SPANS (@ 1.5% INITIAL SAG) MAX. MAX. LOADING MIN. BENDING MIN. BENDING
FEET (METERS) SAGGING TENSION OPERATING TENSION RADIUS (DYNAMIC) RADIUS (STATIC)
CABLE LIGHT MEDIUM HEAVY LBS N LBS N INCHES CM INCHES CM
Mini-Span 323 500 (152) 300 (91) 175 (53) 147 654 374 1668 7 17 3.5 8.5
Mini-Span 383 450 (137) 300 (91) 180 (55) 183 814 402 1,785 8 20 4 10
NESC SPANS (@ 1% INITIAL SAG) MAX. MAX. LOADING MIN. BENDING MIN. BENDING
FEET (METERS) SAGGING TENSION OPERATING TENSION RADIUS (DYNAMIC) RADIUS (STATIC)
CABLE LIGHT MEDIUM HEAVY LBS N LBS N INCHES CM INCHES CM
Mini-Span 424 600 (183) 440 (134) 275 (84) 424 1886 707 3145 9 22 4 11
Mini-Span 535 1050 (320) 850 (259) 575 (175) 1,306 5,809 1,783 7,936 13 27 5 14
Mini-Span 693 750 (229) 600 (183) 500 (152) 1,411 6,278 1,856 8,260 14 36 7 18
Optical Information
MAXIMUM ATTENUATION (db/km) BANDWIDTH (MHz•km)
MULTIMODE MULTIMODE MULTIMODE MULTIMODE
SINGLE-MODE SINGLE-MODE
*62.5/125 µm 50/125 µm *62.5/125 µm 50/125 µm
(1310 nm/1550 nm) (1310 nm/1550 nm)
CABLE (850 nm/1300 nm) (850 nm/1300 nm) (850 nm/1300 nm) (850 nm/1300 nm)
Mini-Span 323 0.40/0.30 3.5/1.2 3.5/1.2
Mini-Span 383
Mini-Span 424 n/a 200/600 500/500
0.35/0.25 3.5/1.2 2.9/0.9
Mini-Span 535
Mini-Span 693
* All 62.5/125 µm multimode ADSS cable transmission performances meet or exceed FDDI requirements.
Premium transmission performance fibers available on request.
www.AFLglobal.com or (800) 235-3423 © 2010, AFL, all rights reserved. PP-1-00013, Revision 4, 7.17.14
Specifications are subject to change without notice.
92
Fiber Optic Cable
Mechanical Data
NOMINAL NOMINAL MAXIMUM LENGTHS*
FIBER DIAMETER WEIGHT SINGLE-MODE MULTIMODE
CABLE COUNT INCHES MM LBS/1000’ KG/KM FEET METERS FEET METERS
Mini-Span 323 2-24 0.323 8.2 35 53 32,800 10,000 26,250 8,000
Mini-Span 383 2-48 0.383 9.7 49 72 32,800 10,000 26,250 8,000
Mini-Span 424 2-60 0.424 10.8 57 84 32,800 10,000 26,250 8,000
Mini-Span 535 2-96 0.535 13.6 100 148 32,800 10,000 26,250 8,000
Mini-Span 693 2-144 0.693 17.6 151 224 23,000 7,000 23,000 7,000
Ordering Information
FIBER FIBERS NUMBER OF AFL NO.
CABLE COUNT PER TUBE TUBES / FIBERS SINGLE-MODE MULTIMODE 62.5/125 MULTIMODE 50/125
6 6 1 w/6 AE00696420AA1 AE00666420AA1 AE00656420AA1
12 6 2 w/6 AE01296420AA1 AE01266420AA1 AE01256420AA1
Mini-Span 323
18 6 3 w/6 AE01896420AA1 AE01866420AA1 AE01856420AA1
24 6 4 w/6 AE02496420AA1 AE02466420AA1 AE02456420AA1
6 6 1 w/6 (3 fillers) AE0069C420AA0 AE0066C420AA0 AE0065C420AA0
12 12 1 w/12 (3 fillers) AE0129C420AA0 AE0126C420AA0 AE0125C420AA0
18 12 1 w/12, 1 w/6 (2 fillers) AE0189C420AA0 AE0186C420AA0 AE0185C420AA0
Mini-Span 383 24 12 2 w/12 (2 fillers) AE0249C420AA0 AE0246C420AA0 AE0245C420AA0
30 12 2 w/12, 1 w/6 (1 filler) AE0309C420AA0 AE0306C420AA0 AE0305C420AA0
36 12 3 w/12 (1 filler) AE0369C420AA0 AE0366C420AA0 AE0365C420AA0
48 12 4 w/12 AE0489C420AA0 AE0486C420AA0 AE0485C420AA0
6 6 1 w/6 (4 fillers) AE0069C520AA4 AE0066C520AA4 AE0065C520AA4
12 12 1 w/12 (4 fillers) AE0129C520AA4 AE0126C520AA4 AE0125C520AA4
18 12 1 w/12, 1 w/6 (3 fillers) AE0189C520AA4 AE0186C520AA4 AE0185C520AA4
24 12 2 w/12 (3 fillers) AE0249C520AA4 AE0246C520AA4 AE0245C520AA4
Mini-Span 424
30 12 2 w/12, 1 w/6 (2 fillers) AE0309C520AA4 AE0306C520AA4 AE0305C520AA4
36 12 3 w/12 (2 fillers) AE0369C520AA4 AE0366C520AA4 AE0365C520AA4
48 12 4 w/12 (1 filler) AE0489C520AA4 AE0486C520AA4 AE0485C520AA4
60 12 5 w/12 (no fillers) AE0609C520AA4 AE0606C520AA4 AE0605C520AA4
6 6 1 w/6 (7 fillers) AE0069C820EA7 AE0066C820EA7 AE0065C820EA7
12 12 1 w/12 (7 fillers) AE0129C820EA7 AE0126C820EA7 AE0125C820EA7
18 12 1 w/12, 1 w/6 (6 fillers) AE0189C820EA7 AE0186C820EA7 AE0185C820EA7
24 12 2 w/12 (6 fillers) AE0249C820EA7 AE0246C820EA7 AE0245C820EA7
30 12 2 w/12, 1 w/6 (5 fillers) AE0309C820EA7 AE0306C820EA7 AE0305C820EA7
Mini-Span 535 36 12 3 w/12 (5 fillers) AE0369C820EA7 AE0366C820EA7 AE0365C820EA7
48 12 4 w/12 (4 fillers) AE0489C820EA7 AE0486C820EA7 AE0485C820EA7
60 12 5 w/12 (3 fillers) AE0609C820EA7 AE0606C820EA7 AE0605C820EA7
72 12 6 w/12 (2 fillers) AE0729C820EA7 AE0726C820EA7 AE0725C820EA7
84 12 7 w/12 (1 filler) AE0849C820EA7 AE0846C820EA7 AE0845C820EA7
96 12 8 w/12 (no fillers) AE0969C820EA7 AE0966C820EA7 AE0965C820EA7
12 12 1 w/12 (11 fillers) AE0129CC20EA0 AE0126CC20EA0 AE0125CC20EA0
24 12 2 w/12 (10 fillers) AE0249CC20EA0 AE0246CC20EA0 AE0245CC20EA0
36 12 3 w/12 (9 fillers) AE0369CC20EA0 AE0366CC20EA0 AE0365CC20EA0
48 12 4 w/12 (8 fillers) AE0489CC20EA0 AE0486CC20EA0 AE0485CC20EA0
60 12 5 w/12 (7 fillers) AE0609CC20EA0 AE0606CC20EA0 AE0605CC20EA0
72 12 6 w/12 (6 fillers) AE0729CC20EA0 AE0726CC20EA0 AE0725CC20EA0
Mini-Span 693
84 12 7 w/12 (5 fillers) AE0849CC20EA0 AE0846CC20EA0 AE0845CC20EA0
96 12 8 w/12 (4 fillers) AE0969CC20EA0 AE0966CC20EA0 AE0965CC20EA0
108 12 9 w/12 (3 fillers) AE1089CC20EA0 AE1086CC20EA0 AE1085CC20EA0
120 12 10 w/12 (2 fillers) AE1209CC20EA0 AE1206CC20EA0 AE1205CC20EA0
132 12 11 w/12 (1 filler) AE1329CC20EA0 AE1326CC20EA0 AE1325CC20EA0
144 12 12 w/12 (no fillers) AE1449CC20EA0 AE1446CC20EA0 AE1445CC20EA0
Contact customer service for price and availability. Non-zero dispersion-shifted fibers are also available.
www.AFLglobal.com or (800) 235-3423 © 2010, AFL, all rights reserved. PP-1-00013, Revision 4, 7.17.14
Specifications are subject to change without notice.
93
Fiber Optic Cable
www.AFLglobal.com or (800) 235-3423 © 2010, AFL, all rights reserved. PP-1-00013, Revision 4, 7.17.14
Specifications are subject to change without notice.
94
Fiber Optic Cable
275 84 1.0 194 863 0.6 378 1,681 2.8 491 2,184 4.3 690 3,069
300 91 1.0 212 943 0.6 404 1,737 2.8 524 2,331 — — —
325 99 1.0 230 1,023 0.6 429 1,908 2.9 556 2,473 — — —
350 107 1.0 247 1,099 0.6 455 2,024 3.0 587 2,611 — — —
375 114 1.0 265 1,179 0.6 479 2,131 3.0 618 2,749 — — —
400 122 1.0 283 1,259 0.6 504 2,242 3.1 648 2,882 — — —
425 130 1.0 300 1,334 0.7 528 2,349 3.1 678 3,016 — — —
450 137 1.0 318 1,415 0.7 552 2,455 3.2 703 3,145 — — —
475 145 1.0 336 1,495 0.7 576 2,562 — — — — — —
500 152 1.0 353 1,570 0.7 600 2,669 — — — — — —
525 160 1.0 371 1,650 0.7 623 2,771 — — — — — —
550 168 1.0 389 1,730 0.7 646 2,874 — — — — — —
575 175 1.0 406 1,806 0.7 669 2,976 — — — — — —
600 183 1.0 424 1,886 0.7 692 3,078 — — — — — —
www.AFLglobal.com or (800) 235-3423 © 2010, AFL, all rights reserved. PP-1-00013, Revision 4, 7.17.14
Specifications are subject to change without notice.
95
Fiber Optic Cable
500 152 1 622 2,767 0.7 968 4,304 2.6 1,166 5,188 3.9 1,571 6,988
550 168 1 684 3,043 0.7 1,045 4,647 2.7 1,255 5,583 4.0 1,685 7,495
575 175 1 715 3,180 0.7 1,083 4,817 2.7 1,299 5,778 4.1 1,741 7,745
600 183 1 746 3,318 0.7 1,121 4,985 2.7 1,342 5,971 — — —
650 198 1 808 3,594 0.8 1,196 5,320 2.8 1,428 6,353 — — —
700 213 1 870 3,870 0.8 1,270 5,650 2.8 1,513 6,730 — — —
750 229 1 933 4,150 0.8 1,344 5,978 2.8 1,597 7,102 — — —
800 244 1 995 4,426 0.8 1,417 6,303 2.9 1,679 7,469 — — —
850 259 1 1,057 4,702 0.8 1,489 6,625 2.9 1,761 7,833 — — —
900 274 1 1,119 4,978 0.8 1,561 6,945 — — — — — —
950 290 1 1,181 5,253 0.8 1,633 7,263 — — — — — —
1,000 305 1 1,243 5,529 0.8 1,704 7,579 — — — — — —
1,050 320 1 1,306 5,809 0.8 1,775 7,894 — — — — — —
50 15 1.0 94 418 0.5 201 894 1.5 241 1,072 2.1 336 1,495
100 30 1.0 188 836 0.6 347 1,544 1.8 409 1,820 2.6 558 2,483
150 46 1.0 282 1,255 0.6 479 2,131 2.0 559 2,487 2.9 752 3,346
200 61 1.0 376 1,673 0.7 602 2,679 2.1 698 3,106 3.1 930 4,138
250 76 1.0 470 2,091 0.7 721 3,208 2.2 830 3,693 3.3 1,097 4,881
MINI-SPAN 693
300 91 1.0 565 2,514 0.7 836 3,720 2.3 958 4,263 3.4 1,257 5,593
350 107 1.0 659 2,932 0.8 949 4,223 2.4 1,081 4,810 3.6 1,411 6,278
400 122 1.0 753 3,350 0.8 1,059 4,712 2.5 1,202 5,348 3.7 1,560 6,941
450 137 1.0 847 3,769 0.8 1,168 5,197 2.5 1,321 5,878 3.8 1,705 7,586
500 152 1.0 941 4,187 0.8 1,275 5,673 2.6 1,437 6,394 3.9 1,847 8,218
550 168 1.0 1,035 4,605 0.8 1,381 6,145 2.6 1,552 6,906 — — —
600 183 1.0 1,129 5,023 0.8 1,486 6,612 2.7 1,665 7,408 — — —
650 198 1.0 1,223 5,442 0.8 1,591 7,079 — — — — — —
700 213 1.0 1,317 5,860 0.9 1,694 7,537 — — — — — —
750 229 1.0 1,411 6,278 0.9 1,797 7,996 — — — — — —
www.AFLglobal.com or (800) 235-3423 © 2010, AFL, all rights reserved. PP-1-00013, Revision 4, 7.17.14
Specifications are subject to change without notice.
96
Fiber Optic Cable
Reel Information
REEL SPECS REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 182.8 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight with Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 320 kg 950 lbs 431 kg
MAXIMUM CABLE LENGTH (feet/meters)
Mini-Span 323 15,256 ft 4,650 m 32,800 ft 10,000 m — — — — — —
Mini-Span 383 10,827 ft 3,300 m 25,202 ft 7,700 m 32,800 ft 10,000 m — — — —
Mini-Span 424 8,850 ft 2,700 m 20,250 ft 6,200 m 26,250 ft 8,000 m 32,800 ft 10,000 m — —
Mini-Span 484 6,500 ft 2,000 m 15,750 ft 4,800 m 21,000 ft 6,450 m 32,800 ft 10,000 m — —
Mini-Span 535 5,500 ft 1,675 m 12,800 ft 3,900 m 17,225 ft 5,250 m 26,000 ft 6,920 m 32,800 ft 10,000 m
Mini-Span 693 — — 9,300 ft 2,835 m 12,500 ft 3,810 m 16,330 ft 4,975 m 23,000 ft 7,000 m
AFL provides ADSS cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available on request.
www.AFLglobal.com or (800) 235-3423 © 2010, AFL, all rights reserved. PP-1-00013, Revision 4, 7.17.14
Specifications are subject to change without notice.
97
Fiber Optic Cable
GIGABIT ETHERNET
MAXIMUM ATTENUATION OVERFILL LAUNCH MIN. MINIMUM
(dB/km) BANDWIDTH (MHz•km) LINK DISTANCE (meters)
FIBER TYPE 850 nm 1300 nm 1310 nm 1550 nm 850 nm 1300 nm 850 nm 1300 nm
(6) 62.5/125 GIGA-Link™ 300 3.5 1.2 N/A N/A 200 600 300 550
(8) 62.5/125 GIGA-Link™ 1000 3.5 1.2 N/A N/A 350 600 500 1000
(5) 50/125 GIGA-Link™ 600 2.9 0.9 N/A N/A 500 500 600 600
(7) 50/125 GIGA-Link™ 2000 2.9 0.9 N/A N/A 500 800 750 2000
(L) 50 Laser-Link™ 300 2.9 0.9 N/A N/A 1500 500 900 550
(9) Single-mode N/A N/A 0.35 0.25 N/A N/A N/A 5000
(Q) Non-zero Dispersion-shifted Single-mode N/A N/A N/A 0.25 N/A N/A N/A N/A
(K) SM Futureguide SR-15e Bend Insensitive N/A N/A 0.35 0.25 N/A N/A N/A 5000
Gigabit Ethernet Minimum Link Distances are based on “bandwidth”/modal dispersion constraints.
Actual link distances may be constrained by attenuation, depending on specific loss budget.
Reel Information
REEL A REEL B REEL C REEL D REEL E
ITEM INCHES CM INCHES CM INCHES CM INCHES CM INCHES CM
Reel Height 42 106.7 58 147.3 66 167.6 72 167.6 84 213.4
Reel Width Outside 36 91.4 38 96.5 42 106.7 42 106.7 40 101.6
Reel Width Inside 32 81.6 32 81.3 36 91.4 36 91.4 34 86.4
Drum Diameter 23 58.7 28 71.1 36 91.4 36 91.4 35 88.9
Arbor Hole Diameter 3 7.9 3 7.9 3 7.9 3 7.9 3 7.9
Reel Weight with Lagging 180 lbs 82 kg 420 lbs 191 kg 685 lbs 311 kg 710 lbs 311 kg 950 lbs 431 kg
AFL provides ADSS cable on several standard sizes of non-returnable wooden reels. Non-standard reel sizes are available upon request.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00070, Revision 0, 2.25.14
Specifications are subject to change without notice.
98
Fiber Optic Cable
700 213 AE024C520AA5 0.058 86 0.425 10.8 746 3320 338 1504 0.8 705 3137
800 244 AE024C520EA0 0.06 90 0.433 11 936 4165 402 1789 0.8 838 3729
H
925 282 AE024C520EA1 0.06 90 0.433 11 999 4445 464 2065 0.8 951 4232
1010 308 AE024C520EA2 0.06 90 0.433 11 1062 4726 507 2256 0.8 1032 4592
1100 335 AE024C520EA4 0.06 90 0.433 11 1189 5291 553 2461 0.8 1131 5033
G
48 FIBERS
525 160 AE048C520A08 0.06 89 0.425 10.8 539 2398 261 1161 0.9 528 2350
I
600 183 AE048C520AA1 0.06 89 0.425 10.8 628 2794 298 1326 0.9 606 2697
L
700 213 AE048C520AA5 0.06 89 0.425 10.8 746 3320 349 1553 0.8 711 3164
800 244 AE048C520EA0 0.062 93 0.433 11 936 4165 414 1842 0.8 845 3760
925 282 AE048C520EA1 0.062 93 0.433 11 999 4445 479 2131 0.9 958 4263
1030 314 AE048C520EA2 0.062 93 0.433 11 1062 4726 534 2376 0.9 1056 4699
1100 335 AE048C520EA4 0.062 93 0.433 11 1189 5291 570 2536 0.9 1140 5073
72 FIBERS
725 221 AE072C620A08 0.075 112 0.465 11.8 854 3800 454 2020 0.9 832 3702
800 244 AE072C620AA0 0.075 112 0.465 11.8 913 4063 501 2229 0.9 911 4054
875 267 AE072C620AA3 0.075 112 0.465 11.8 1002 4459 548 2438 0.9 998 4441
975 297 AE072C620AA7 0.075 112 0.465 11.8 1120 4984 611 2719 0.9 1113 4953
1075 328 AE072C620EA0 0.075 112 0.465 11.8 1250 5562 674 2999 0.9 1230 5473
96 FIBERS
925 282 AE096C820A08 0.1 148 0.528 13.4 1296 5767 769 3422 1 1270 5651
1000 305 AE096C820AA1 0.1 149 0.528 13.4 1384 6159 832 3702 1 1370 6096
144 FIBERS
1050 320 AE144CC20A08 0.164 244 0.673 17.10 2070 9211 1433 6377 1.1 2048 9113
1
Initial tension indicates tension before 10 year creep.
Fiber Types – Replace asterisk () in AFL number with number corresponding to desired fiber type below.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00070, Revision 0, 2.25.14
Specifications are subject to change without notice.
99
Fiber Optic Cable
400 122 AE024C520AA0 0.058 86 0.425 10.8 598 2661 192 854 3.5 575 2559
500 152 AE024C520AA5 0.058 86 0.425 10.8 746 3320 242 1077 3.5 719 3199
U
625 190 AE024C520EA0 0.06 90 0.433 11 936 4165 314 1397 3.5 908 4040
650 198 AE024C520EA1 0.06 90 0.433 11 999 4445 326 1451 3.4 951 4232
700 213 AE024C520EA2 0.06 90 0.433 11 1062 4726 352 1566 3.5 1021 4543
I
800 244 AE024C520EA4 0.06 90 0.433 11 1189 5291 402 1789 3.5 1160 5162
D
48 FIBERS
375 114 AE048C520A08 0.06 89 0.425 10.8 539 2398 187 832 3.5 536 2385
E
425 130 AE048C520AA1 0.06 89 0.425 10.8 628 2794 211 939 3.5 612 2723
500 152 AE048C520AA5 0.06 89 0.425 10.8 746 3320 250 1112 3.5 723 3217
M
625 190 AE048C520EA0 0.062 93 0.433 11 936 4165 324 1442 3.5 913 4063
650 198 AE048C520EA1 0.062 93 0.433 11 999 4445 337 1500 3.4 957 4258
700 213 AE048C520EA2 0.062 93 0.433 11 1062 4726 363 1615 3.5 1027 4570
800 244 AE048C520EA4 0.062 93 0.433 11 1189 5291 415 1847 3.5 1167 5193
72 FIBERS
525 160 AE072C620A08 0.075 112 0.465 11.8 854 3800 328 1460 3.4 825 3671
575 175 AE072C620AA0 0.075 112 0.465 11.8 913 4063 360 1602 3.4 899 4000
625 190 AE072C620AA3 0.075 112 0.465 11.8 1002 4459 391 1740 3.4 979 4356
710 216 AE072C620AA7 0.075 112 0.465 11.8 1120 4984 445 1980 3.5 1108 4930
800 244 AE072C620EA0 0.075 112 0.465 11.8 1250 5562 501 2229 3.5 1245 5540
96 FIBERS
725 221 AE096C820A08 0.1 148 0.528 13.4 1296 5767 603 2683 3.4 1282 5705
775 236 AE096C820AA1 0.1 149 0.528 13.4 1384 6159 645 2870 3.4 1370 6096
144 FIBERS
875 267 AE144CC20A08 0.164 244 0.673 17.10 2070 9211 1195 5318 3.2 2028 9024
1
Initial tension indicates tension before 10 year creep.
Fiber Types – Replace asterisk () in AFL number with number corresponding to desired fiber type below.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00070, Revision 0, 2.25.14
Specifications are subject to change without notice.
100
Fiber Optic Cable
300 91 AE024C520AA5 0.058 86 0.425 10.8 746 3320 145 645 4.6 712 3168
375 114 AE024C520EA0 0.06 90 0.433 11 936 4165 188 837 4.6 897 3991
V
400 122 AE024C520EA1 0.06 90 0.433 11 999 4445 201 894 4.6 957 4258
450 137 AE024C520EA2 0.06 90 0.433 11 1062 4726 219 975 4.7 1054 4690
A
500 152 AE024C520EA4 0.06 90 0.433 11 1189 5291 251 1117 4.7 1179 5246
48 FIBERS
AE048C520A08
E
200 61 0.06 89 0.425 10.8 539 2398 99 441 4.5 487 2167
250 76 AE048C520AA1 0.06 89 0.425 10.8 628 2794 124 552 4.6 596 2652
H
300 91 AE048C520AA5 0.06 89 0.425 10.8 746 3320 150 667 4.6 714 3177
375 114 AE048C520EA0 0.062 93 0.433 11 936 4165 194 863 4.6 900 4005
400 122 AE048C520EA1 0.062 93 0.433 11 999 4445 207 921 4.6 960 4272
450 137 AE048C520EA2 0.062 93 0.433 11 1062 4726 233 1037 4.7 1062 4726
500 152 AE048C520EA4 0.062 93 0.433 11 1189 5291 259 1153 4.7 1183 5264
72 FIBERS
300 91 AE072C620A08 0.075 112 0.465 11.8 854 3800 188 837 4.4 774 3444
350 107 AE072C620AA0 0.075 112 0.465 11.8 913 4063 219 975 4.6 880 3916
400 122 AE072C620AA3 0.075 112 0.465 11.8 1002 4459 250 1112 4.6 995 4428
450 137 AE072C620AA7 0.075 112 0.465 11.8 1120 4984 282 1255 4.6 1117 4970
500 152 AE072C620EA0 0.075 112 0.465 11.8 1250 5562 313 1393 4.6 1243 5531
96 FIBERS
400 122 AE096C820A08 0.1 148 0.528 13.4 1296 5767 333 1482 4.3 1140 5073
500 152 AE096C820AA1 0.1 149 0.528 13.4 1384 6159 416 1851 4.5 1364 6070
144 FIBERS
600 183 AE144CC20A08 0.164 244 0.673 17.10 2070 9211 819 3644 4.3 2007 8931
1
Initial tension indicates tension before 10 year creep.
Fiber Types – Replace asterisk () in AFL number with number corresponding to desired fiber type below.
www.AFLglobal.com or (800) 235-3423 © 2014, AFL, all rights reserved. PP-1-00070, Revision 0, 2.25.14
Specifications are subject to change without notice.
101
Mini-Dead Ends
The Mini-Dead Ends are designed for fast and easy installation of your ADSS
Mini-Span® cable. The Mini-Dead End is ideal in crowded distribution environments
where its shorter length allows for efficient installation. This unique low-cost product
is used in typical spans with 1%-2% installation sag.
Features
ADESDFW2-256 & 307
• Easy and quick installation
• No special tools or hardware
required for installation
• Small, requiring less storage space
Ordering Information
APPLICATION & DESCRIPTION AFL NO.
Aerial Drop 256 ADESDFW2-256
150 ft NESC heavy, 275 ft NESC medium, 550 ft NESC light
Aerial Drop 307—Short Span (250 lb max. tension) ADESDFW2-307
ADELD2E-323T & 383T 65 ft NESC heavy, 115 ft NESC medium, 210 ft NESC light
Aerial Drop 307—Long Span ADELD2E-013TE
220 ft NESC heavy, 400 ft NESC medium, 675 ft NESC light
ADSS Mini-Span 323 ADELD2E-323T
175 ft NESC heavy, 300 ft NESC medium, 500 ft NESC light
ADSS Mini-Span 383 ADELD2E-383T
180 ft NESC heavy, 300 ft NESC medium, 450 ft NESC light
ADSS Mini-Span 424 ADELD2E-424005
275 ft NESC heavy, 450 ft NESC medium, 600 ft NESC light
ADSS Mini-Span 484 ADEMS484
275 ft NESC heavy, 400 ft NESC medium, 525 ft NESC light
ADELD2E-424005TE
* shown with optional thimble eye NOTE: Part numbers ADEMS484, ADEW10J1-AL535, and ADEW16J1-AL693 attach to structure via common pole hardware
sold separately such as thimble eye, ram’s head, guy hooks, etc.
For spans greater than the span lengths above, contact Customer Service.
ADEMS484
Features
Maximum one side angle: 8.5 degrees
Mini-Bracket Estimated weight: 2.9 lbs. (1.3 Kg)
Maximum rated strength: 3,000 lbs.
Hand tighten bolt to 25 in. lbs. (2.8 N-m)
Slip load at 4 to 6% of RBS
Ordering Information
DESCRIPTION AFL NO.
Aerial Drop 256 AMBB256
maximum line angle =17° (150 ft NESC heavy, 275 ft NESC medium, 550 ft NESC light)
Aerial Drop 307 AMBB307
maximum line angle =17° (220 ft NESC heavy, 400 ft NESC medium, 675 ft NESC light)
ADSS Mini-Span 424 AMBB424
maximum line angle =17° (275 ft NESC heavy, 450 ft NESC medium, 600 ft NESC light)
ADSS Mini-Span 484 AMBB484-535
maximum line angle =17° (275 ft NESC heavy, 400 ft NESC medium, 525 ft NESC light)
ADSS Mini-Span 535 AMBB484-535
maximum line angle =17° (350 ft NESC heavy, 550 ft NESC medium, 675 ft NESC light)
Ordering Information
ATS 321/330
ATS 371/383 DESCRIPTION AFL NO.
ADSS Mini-Span 323 ATS321/330
maximum line angle = 20°(175 ft NESC heavy, 300 ft NESC medium, 500 ft NESC light)
ADSS Mini-Span 383 ATS371/383
maximum line angle = 20°(180 ft NESC heavy, 300 ft NESC medium, 450 ft NESC light)
Caution: The load ratings shown here are based on performance results of certain cable configurations and may not
be representative of all manufacturers’ ADSS cable designs. AFL strongly recommends that before using this product,
you contact AFL to obtain the recommended load rating and to verify that the wedge dead end has been qualified for
use with the proposed cable. AFL will perform a qualification test at no charge.
Specifications
PARAMETER VALUE
Wedge Length 10" or 16" depending on cable characteristics
ADEW16J1-AL693 Cable O.D. 0.512" to 0.890" (13 mm to 22.6 mm)
Hold Strength 100% of Maximum Rated Cable Load (MRCL)
ADE W 16 J2 AL YYY
ADSS Dead End Wedge Type Length of wedge ADSS Jacket Type Cable Manufacturer Cable Diameter
Dead End component J2 = Double Layer Code (in Inches)
16 = 16 inch type AL = AFL
Max. Load Rating = 3000 lbs.
Application Notes:
1. For use with ADSS cables with polyethylene jackets only. Not for use on track resistant ADSS cable.
2. AFL fiber optic cable and related hardware are designed to work as a system. Dead ends may not be available for cable from other manufacturers.
LENGTH "L"
ALL DIELECTRIC
SELF SUPPORTING CABLE
2
LENGTH "L"
ALL DIELECTRIC
SELF SUPPORTING CABLE
2
ALL DIELECTRIC
SELF SUPPORTING CABLE
2
Features
• May be used as a pull-through by removing the bushing inserts
• High-strength aluminum
• Smaller and more compact design
• Facilitates faster installation
• Color-coded range taking inserts for easy identification
• Versatile mounting styles to fit different structure types: bolted, banded or standoff
• Banding and pole hardware supplied by customer
• Lowers the total cost of installation
• Span Length: 600 ft. - NESC Heavy
1,200 ft. - NESC Light
Ordering Information
CABLE O.D. RANGE EST. WEIGHT
BUSHING
INCHES MILLIMETERS LBS. KG COLOR AFL NO.
0.420" - 0.474" 10.67 - 12.05 2.05 .930 Black ATGN420/474
0.475" - 0.525" 12.07 - 13.34 2.05 .930 Blue ATGN475/525
0.526" - 0.575" 13.36 - 14.61 2.05 .930 Orange ATGN526/575
0.576" - 0.625" 14.63 - 15.88 2.04 .925 Brown ATGN576/625
0.626" - 0.675" 15.90 - 17.15 2.04 .925 Green ATGN626/675
0.676" - 0.725" 17.17 - 18.42 2.03 .921 White ATGN676/725
0.726" - 0.775" 18.44 - 19.69 2.03 .921 Red ATGN726/775
0.776" - 0.825" 19.71 - 20.96 2.02 .916 Purple ATGN776/825
0.826" - 0.875" 20.98 - 22.23 2.02 .916 Yellow ATGN826/875
0.876" - 0.925" 22.25 - 23.50 2.02 .916 Pink ATGN876/925
Application Notes:
1. For use with ADSS cables with polyethylene jackets only. Not for use on track resistant ADSS cable.
2. As a stringing block:
Maximum line angle = 15º (7.5º per side)
Maximum number of structures = 30
3. For final installation:
Maximum line angle = 22º (11º per side)
Specifications
PARAMETER VALUE
Span Length Rating 600 feet (200 meters) NESC Heavy
900 feet (274 meters) NESC Medium
1200 feet (365 meters) NESC Light
Vertical Load Rating 5000 lbs
Torque Requirement Mounting bolt should be tightened to 25 ft-lb
Mounting Hardware 5/8" oval eye nut and anchor shackle (both parts not shown) can be included in
the assembly by adding the suffix "AS01" to the part number
Line Angle Max line angle is 30 degrees
Cable Types Recommended For use on standard polyethylene jackets only
DO NOT USE on track resistant cables
Slip Strength Contact AFL for specific slip strength requirements
Ordering Information
CABLE RANGE WEIGHT BRUSHING
AFL NO. INCHES MM LBS KG COLOR
ASN420/474 0.420 - 0.474 10.7 - 12.0 Black
ASN475/525 0.475 - 0.525 12.1 - 13.3 Blue
ASN526/575 0.526 - 0.575 13.4 - 14.6 Orange
ASN576/625 0.576 - 0.625 14.6 - 15.9 Brown
NOTE: correct orientation of bushing ASN626/675 0.626 - 0.675 15.9 - 17.1 Green
shown above. ASN676/725 0.676 - 0.725 17.2 - 18.4 White
2.2 1.0
ASN726/775 0.726 - 0.775 18.4 - 19.7 Red
ASN776/825 0.776 - 0.825 19.7 - 21.0 Purple
ASN826/875 0.826 - 0.875 21.0 - 22.2 Yellow
ASN876/925 0.876 - 0.925 22.3 - 23.5 Pink
ASN926/959 0.926 - 0.959 23.5 - 24.4 —
ASN960/1045 0.960 - 0.1045 24.4 - 26.5 Gray
EDPM BUSHINGS
1a L1
L2
1b
3 2
1c
Ordering Information
STRUCTURAL REINFORCEMENT RODS OUTER RODS
LENGTH "L1" ROD DIA. RODS PER COLOR LENGTH"L2" ROD DIA. RODS PER COLOR
CABLE O.D. RANGE (INCHES) (INCHES) SET CODE (INCHES) (INCHES) SET CODE AFL NO.
0.399" - 0.418" 80 .146 10 Yellow 42 .204 11 Yellow ASU399/418
0.419" - 0.439" 80 .146 10 Black 42 .204 11 Black ASU419/439
0.440" - 0.458" 81 .146 11 White 43 .204 11 White ASU440/458
0.459" - 0.461" 84 .167 10 Purple 46 .250 10 Orange ASU459/461
0.462" - 0.476" 84 .167 10 Purple 46 .250 10 Purple ASU462/476
0.477" - 0.503" 84 .146 12 Orange 46 .250 10 Orange ASU477/503
0.504" - 0.511" 84 .146 12 Red 46 .250 10 Purple ASU504/511
0.512" - 0.536" 87 .167 11 Blue 49 .250 11 Blue ASU512/536
0.537" - 0.559" 87 .167 11 Green 49 .250 11 Green ASU537/559
0.560" - 0.565" 87 .167 11 Green 49 .250 11 Green ASU560/565
0.566" - 0.573" 92 .182 11 Black 54 .250 12 Black ASU566/573
0.574" - 0.598" 92 .182 11 Black 54 .250 12 White ASU574/598
0.599" - 0.625" 92 .182 12 Brown 54 .310 12 Brown ASU599/625
0.626" - 0.632" 102 .204 11 Red 63 .310 11 Red ASU626/632
0.633" - 0.666" 102 .204 11 Red 63 .310 11 Blue ASU633/666
0.667" - 0.682" 102 .204 12 Yellow 63 .310 11 Green ASU667/682
0.683" - 0.710" 102 .204 12 Yellow 63 .310 11 Yellow ASU683/710
0.711" - 0.728" 102 .204 12 White 63 .310 12 Black ASU711/728
0.729" - 0.744" 102 .204 12 White 63 .310 12 White ASU729/744
0.745" - 0.750" 102 .204 12 White 63 .310 12 White ASU745/750
0.751" - 0.786" 102 .204 13 White 63 .310 12 Brown ASU751/786
0.787" - 0.814" 111 .250 11 Green 72 .365 11 Green ASU787/814
0.815" - 0.845" 111 .250 12 Yellow 72 .365 11 Yellow ASU815/845
0.846" - 0.855" 111 .250 12 Green 72 .365 12 Blue ASU846/855
0.856" - 0.894" 119 .250 12 Black 80 .365 12 Black ASU856/894
0.895" - 0.907" 119 .250 12 White 80 .365 12 White ASU895/907
0.908" - 0.916" 119 .250 13 Purple 80 .365 12 Purple ASU908/916
0.917" - 0.929" 119 .250 13 Brown 80 .365 12 Brown ASU917/929
0.930" - 0.942" 119 .250 13 Red 80 .365 12 Red ASU930/942
0.943" - 0.977" 119 .250 13 Orange 80 .365 13 Orange ASU943/977
Ordering Example:
For .512" diameter ADSS, the part number is AWG 469/561
A B
(25 MM)
(51 MM)
2.00"
ADSS ELASTOMER
BUSHING
INSTALLATION INSTRUCTIONS
FDOA B & C Series – Downlead Clamp for OPGW and ADSS
with Optional Lattice Structure Adapter
WASHER
BOLT
BUSHING
MOUNTING
CLAMP
DOWNLEAD
CLAMP
NUT
TOWER ANGLE
FIG. 1 FIG. 2
1. Attach mounting clamp adapter to tower angle (as illustrated in Fig. 1) with break-away bolt (breaking torque range: 20-25 lbf-ft).
2. Lay the proper OPGW and/or ADSS cable in each bushing groove of the bottom clamp. Place top clamp over the cables and ensure the bushing
color code and cable diameter match the table below.
3. Bolt the downlead clamp to mounting clamp (as illustrated in Fig. 2). Hold the mounting clamp and downlead clamp halves while tightening
the hardware to prevent rotation and bending of the OPGW and/or ADSS cables.
4. Tighten the bolt on the downlead clamp until a bolt torque of 20-25 lbf-ft is achieved.
CAUTION: In order to avoid any damage to the OPGW and/or ADSS cable, it is essential that the cable be clamped only in the
recommended bushings.
CABLE
NOTE SMALLER HELIX
NOTE: OPGW and ADSS Spiral Vibration Dampers are not interchangeable.
The mounting bracket features an angled, tent-profile, epoxy-coated bracket for standard
ADSS cable mounting.
Features
Small profile and side facing channel Basic hanging hardware (bolts, nuts,
minimizes ice and leaf loading washers) and strand clamps all included
Constructed from UV stabilized PPE Tie-wrap slots for securing cable
thermoplastic Epoxy-coated strand clamps
Specifications
PARAMETER FOS18-AD-4010
Nominal Channel Width - in. 1.00
Minimum Bend Diameter - in. 17.5
Cable Diameter Range - in. 0.4-1
Ordering Information
AFL NO. FOS18-AD-4010
Kits contain one pair of FOSP and two sets of hanger brackets.
Whether your application is voice, video, and/or data, or you are a service provider, contractor, or end user, The Light Brigade can
provide critical training for your personnel to lower operating costs and improve installation efficiency.
Instructors
Our professional instructors and technicians are technically skilled and have a variety of real world practical experience in all aspects
of fiber optics. With experience in applications such as communications, signaling, security, and network control, our instructors
provide valuable insight into the design, installation, and operation of state-of-the-art fiber optic systems.
Hands-on Training
Extensive hands-on training sessions help our attendees to learn fiber optics by doing rather than watching. Attendees spend
class time building, testing, and troubleshooting an actual fiber optic system. In each of our courses, the ratio of students to instructors
during the hands-on sessions assures that there is direct personal interaction and attention to each student.
Technology-based
In our training classes, you receive an objective viewpoint, not a sales pitch. We teach fiber techniques that are applicable to any
product, and select the best available equipment and supplies from many different manufacturers. You can choose to develop your
skills using our state-of-the-art equipment and accessories, or bring your own to learn how to use it more effectively.
Relevant
Our course materials are constantly updated to stay in step with current and emerging technologies. All of our materials
and techniques are written and taught based on the latest standards, recommendations, and codes from ANSI, ITU, TIA/EIA,
IEEE, IEC, Telcordia, MSHA, NEC, NESC, and others.
Continuing Support
To assure continued long-term support, we offer technical assistance to our class attendees. If you have a question or need
help after the class is over, our staff is there to help.
In addition, many of our courses are eligible for BICSI Continuing Education Credits (CECs), SCTE Recertification Units (RUs), IMSA
Technical Advancement Recognition Points (TARPs), and Infocomm Recertification Units (RUs).
IMSA Level II
IMSA Level I
UTC Level 1
UTC Level 2
UTC Level 3
BICSI CECs
FOA CFOT
Infocomm
SCTE RUs
ETA FOI
CFHP
Page
RUs
Fiber Optics 1-2-3 10 • • •
FTTH Council
Advanced Hands-on Modules 11 • • •
Certified Fiber to the Home Professional 12 • •
FTTx for Installers and Technicians 13 • • •
Fiber Characterization 14 •
Emergency Restoration 15 •
Fiber Optics for Utilities Level 1 16 • Society of Cable
Telecommunications
Fiber Optics for Utilities Level 2 17 • Engineers (SCTE)
Fiber Optics for Utilities Level 3 (Custom) – •
Fiber Optics for Traffic Systems Level I 18 •
Fiber Optics for Traffic Systems Level II 18 •
Fiber Optics for Traffic Systems Level III 18 •
Fiber Optics for Oil/Gas 19 • Building Industry Consulting
Fiber Optics for Mining Applications 20 • Service International, Inc.
(BICSI)
Fiber Optics for Pro-AV 21 •
Premises/LAN Installation & Maintenance 22 • •
Staff Development DVDs 26 • •