1 Weld Design
1.1 Diagram
This document describes a basic weld capacity check for a hand rail plate attached
to the cladding frame.
All references are
made to AS
F
5100.6-2004
FV
14.00°
FRAME F
14.00°
12 THK PLATE
FV
1.2 Loading
F
FV =
cos(14)
1.7
=
cos(14)
= 1.75 kN
The fillet weld will be subject to the design force per unit length (vw∗ ):
FV
vw∗ =
LW
1750
=
400
= 4.4 N/mm
A fillet weld group subject to a design force per unit length of weld (vw∗ ) at the
ultimate limit shall satisfy :
The nominal capacity of a fillet weld per unit length (vw ) is:
vW = 0.6fuw tt kr
where:
fuw = 450 M pa
Lw = 0.45 m ≤ 1.7 ∴ kr = 1.0
12.6.7.2(B)
Project VeloWay Footscray Page 3/3
Project No. 25667 Updated 15/04/2019
Version Rev 1 Reviewed
Designer Lesego Matojane Reviewer None
Tt
Figure 2: Weld
tt = cos(45) × 6 = 4.24 mm
vw = 0.6fuw tt kr
= 0.6 × 480 × 4.24 × 1.0
= 1221.0 N/mm
Strength Check: