90 KVA AC/DC GPU

AVISH AVIATION

Manufactured By
Avish Aviation Equipments
Pvt Ltd
Factory: Gat no. 64 & 65,
Village Sasewadi, Taluka –
Bhor, District – Pune,
State – Maharashtra
INDIA. Pin Code 412205
Ph.No. +91-20-64512345 /
+91-20-64103921
adityas@avishaviation.com
www.avishaviation.com
90 KVA AC/DC GPU
90 KVA AC/DC GPU Specifications

Output Voltage 28V DC


DC Output up to 400A DC for Servicing Aircraft
up to 2000A DC for Starting Aircraft Engine
AC OUTPUT Up to 90KVA 3 Phase 400Hz AC
Output Connector 3 Pin NATO socket for DC & 6 Pin NATO for AC
Output Cable Length 10 meters Each
Output Cable Double Insulated Cable
Enclosure Towable Trolley
Dimensions (W) 1400mm x (L) 2500mm x (H)1500mm

Generator Details

Engine Kirloskar HA694 TC 6 Cylinder Turbo Charged Air


Cooled Engine
Alternator Emerson 90kva 400Hz Alternator

Control

User Interface 7” Touch Screen TFT LCD Display


OUTPUT ON/OFF Front Panel Push to ON Switch
OUTPUT Protection Disconnection DC Source from cable via DC
Contactor
Emergency Switch Mushroom switch Provided for making unit OFF &
removing Power from Output Cable
Engine Battery Charging Charging Alternator Coupled to Engine
90 KVA AC/DC GPU
AVISH AVIATION

Salient Features
Six Cylinders, Turbo Charged, Air 3 Pin NATO Connector with 10
Cooled Engine coupled with 400Hz meter double insulated cable for
Alternator feeds power to DC output & 6 Pin NATO connector
Transformer Rectifier unit (TRU) to with 10 meter double insulated
generate required DC Output. cable for AC Output.

AC Output is taken from Alternator Trolley Mounted equipment with


Output Single Person Operation.

In DC Only Mode, DC current of Spike Free DC Output, Clean AC


400A & 2000A DC Peak Current for waveform
Engine Starting. Special Booster
7” TFT Touch Screen for Ease of
design enables such higher output
GPU operations
current along with Cable Drop
Compensation. Wide Pneumatic Tires for ease of
movement.
In AC Only Mode, AC power
available is up to 90KVA 3 Phase Protections for DC & AC Output for
400Hz. Over Voltage, Under Voltage.
In AC/DC Mode, Special Design of Disconnection of DC Output via DC
Transformer Rectifier Unit allows Contactor & AC Output via AC
simultaneous use of AC & DC with Contactor to isolate Aircraft from
DC up to 400A continuous and AC GPU in the event of GPU trip.
up to 60KVA 3 Phase 400Hz. In this
mode AC output Total Harmonic Engine Protection, DC Output
Distortion (THD) is below required Protection integrated into GPU
level of 5% Controller & Display unit.
COMPACT AC/DC GPU 28V Battery Cart

90 KVA AC/DC GPU DC GPU

Self Propelled AC/DC GPU

AVISH AVIATION

Avish Aviation Equipments Pvt Ltd


Factory: Gat no. 64 & 65, Village Sasewadi,
Taluka – Bhor, District – Pune,
State – Maharashtra
INDIA. Pin Code 412205
Ph.No. +91-20-64512345 / +91-20-64103921
adityas@avishaviation.com

www.avishaviation.com