(a) Measure the specific gravity of the battery with a hydrometer to find the condition of the battery charge.
NOTE: Some hydrometers will have a built-in temperature compensation chart and a
thermometer.
(b) The battery condition for various hydrometer values with an electrolyte temperature of 80°F (27°C) is shown in
Table 201.
1 Electrolyte measurements with the hydrometer must be compensated for the temperature of the electrolyte.
Refer to Table 202.
NOTE: For increased temperatures, the values will be lower. For decreased temperatures,
the values will be higher.
(c) If the specific gravity indicates the battery is not fully charged, refer to Battery Charging.
(d) Replace the battery if the following conditions are not true:
1 The specific gravity values that are adjusted for temperature must be between 1.260 and 1.290.
2 The specific gravity values between cells must not have a difference of more than 0.020.
3 The battery must give sufficient power to crank the engine with the starter.
NOTE: For more accurate results, you can use a load type tester after you charge the battery.
NOTE: A specific gravity check can be completed after the charge. This check will not find cells
that short circuit under electrical loads, or have broken connectors between cell plates.
Table 201. Battery Hydrometer Values at 80°F (27°C).
VALUE BATTERY CONDITION
1.280 Specific Gravity 100% Charged
1.250 Specific Gravity 75% Charged
1.220 Specific Gravity 50% Charged
1.190 Specific Gravity 25% Charged
1.160 Specific Gravity Not Charged
Table 202. Specific Gravity Correction to 80° (27°C)
ELECTROLYTE TEMPERATURE ADD TO VALUE SUBTRACT FROM VALUE
140°F (60°C) 1.024
130°F (54°C) 1.020
120°F (49°C) 1.016
110°F (43°C) 0.012
100°F (38°C) 0.008
90°F (32°C)
80°F (27°C)
70°F (21°C)
60°F (16°C) 0.008
50°F (10°C) 0.012
40°F (4°C) 0.016
30°F (-1°C) 0.020
20°F (-7°C) 0.024
10°F (-12°C) 0.028
0°F (-18°C) 0.032
-10°F (-23°C) 0.036
-20°F (-29°C) 0.040
HOLD−DOWN BOLT
POSITIVE BATTERY
CABLE
BATTERY VENT LINE
A BATTERY COVER
NEGATIVE BATTERY
CABLE
BATTERY
BATTERY
TRAY FLANGE
HOLD−DOWN RIVET
BOLT POSITIVE BATTERY
BATTERY TRAY
CABLE
BATTERY BATTERY VENT LINE
FIREWALL
COVER
DETAILA
RIVET
BATTERY TRAY
FIREWALL
DETAILA
0510T1007
MAIN BATTERY INSTALLATION A0518T1023