You are on page 1of 4

DESIGN NOTE

FOR
AQUEDUCT OF SIZE 1 x 1.524 x 0.914
INDEX

S.No ITEM Page


1 INTRODUCTION 3-4
2 DIMENSIONS OF BOX 5-5
3 BASIC PARAMETERS 6-6
4 LOAD CALCULATIONS FOR STAAD ANALYSIS 6-6
5 EARTH PRESSURE & LIVE LOAD CALCULATIONS 6 - 10
6 TEMPERATURE LOAD CALCULATION 11 - 12
7 STAAD INPUT FILE 13 - 29
8 SUMMARY OF FACTORED MOMENTS 30 - 30
9 PARTIAL SAFETY FACTORS 31 - 35
VERIFICATION OF STRUCTURAL STRENGTH FOR BOTTOM
10 43 - 46
SLAB
VERIFICATION OF SERVICEABILITY LIMIT STATE FOR BOTTOM
11 47 - 49
SLAB
VERIFICATION OF STRUCTURAL STRENGTH FOR OUTER
12 50 - 53
WALL
VERIFICATION OF SERVICEABILITY LIMIT STATE FOR OUTER
13 54 - 56
WALL
14 SUMMARY OF PROVIDED REINFORCEMENT 57 - 58
15 BASE PRESSURE 59 - 59
INTRODUCTION
The following design note represents the analysis & design of Aqueduct of cell no. 1 and clear span of
1.52m.

REFERENCE DOCUMENTS :-
1 IRC codes /guidelines/special publications
2 Specialised literature as relevant

ANALYSIS & DESIGN:-


The following points have been taken while designing the Box.
1 Structure is designed for per metre width.

2
In case of design sheet under summary of moments, only magnitude of force has been considered.

LOADS CONSIDERED FOR ANALYSIS AND DESIGN :-


Loads and load combinations as per IRC: 6- 2017 have been considered in STAAD. The different types of
loads used are:
1 Dead load.
2 Water Pressure
3 Temperature loading for uniform rise and temperature gradient is considered.
4 Wind Forces
MATERIAL PROPERTIES
1 Grade of Concrete M25
2 Grade of Steel Fe 500D.
AQUEDUCT SIZE (1 CELL) - 1.524M WIDE x 1.5M HEIGHT

2.07 m

0.275 m 0.275 m

1.50 m
1.70 m

1.52 m

0.200 m

2.07 m

DIMENSIONS OF BOX

No. of Cell = 1 Clear Width of cell (B) = 1.52 m


Top Slab Thick. (tt) = 0.000 m Clear Height of Cell (D) = 1.50 m
Bot. Slab Thick. (tb) = 0.200 m C/C Width of structure = 1.80 m
Side Wall Thick. (tw) = 0.275 m C/C Height of structure = 1.600 m
Int. wall Thickness (ti) = 0.00 m Total length of Structure at top = 2.07 m
Total Deck width = 26.12 m Total length of Structure at bottom = 2.07 m
Width between supports = 23.16 m Total Height of Structure = 1.70 m
Water above bott. Slab = 0.457 m Footpath Dimensions = 0.00 m
Haunch size = 0mm x0mm x500mm Height of fill = 0.00 m

BASIC PARAMETERS

3
Density of water = 10 kN/m
3
Density of Concrete = 25 kN/m

LOAD CALCULATIONS FOR STAAD ANALYSIS

1) Fluid Pressure

Fluid Pressure at side walls Height


2
0.00 kN/m 0.000 m
2
4.57 kN/m 0.457 m
2) Load due to water on Bottom Slab

Uniform Load = 4.57 kN/m2

3) Wind Forces REF: IRC 6-2014 CL NO:209.2


Basic Wind Speed = 47 m/s Plain Terrain 1
Design Wind Speed = 39.6 m/s At height 10 27.8
Design Wind Pressure Pz = 940.9

FT = PZ A1 G CD (KN/m2) = 4.51632 G= 2 CD= 2.4


FL = 1.12908
FV = PZ A3 G CL = 1.41135 G= 2.00 CL = 0.75