GRU N DFOS INSTRUCTIONS

CMSP-PM1
Installation and Operating Instructions
English (GB) Installation and operating instructions
Original installation and operating instructions. 3. Mechanical installation
English (GB)

Warning
CONTENTS Page Before starting work on the CM Booster,
1. Symbols used in this document 2 make sure that the power supply has
been switched off and that it cannot be
2. System sizing 2 accidentally switched on.
3. Mechanical installation 2
4. Electrical installation 2 4. Electrical installation
5. Startup 2 Warning
The electrical installation should be
6. Alarms 2 carried out by an authorised person in
7. Fault finding 3 accordance with local regulations.
8. CMSP-PM1 Pictorial Diagram 6 Check that the supply voltage and frequency
correspond to the values stated on the nameplate.
Warning Warning
Prior to installation, read this Before making any connections in the
document and the quick guide. unit, make sure that the power supply
Installation and operation must comply has been switched off and that it
with local regulations and accepted cannot be accidentally switched on.
codes of good practice. The unit must be connected to an
Warning external mains switch with a contact
gap of at least 3 mm in all poles.
The use of this product requires
experience with and knowledge of the As a precaution, the unit must be
product. connected to a socket with earth
Persons with reduced physical, connection.
sensory or mental capabilities must not We recommend to fit the permanent
use this product, unless they are under installation with an earth leakage
supervision or have b een instructed in circuit breaker (ELCB) with a tripping
the use of the product by a person current < 30 mA.
responsible for their safety. 5. Startup
Children must not use or play with this
product. Caution
Do not start the pump until it has been
filled with liquid.
1. Symbols used in this document 6. Alarms
Warning If a dry-running alarm has been
If these safety instructions are not Caution
activated, find the cause before the
observed, it may result in personal pump is restarted in order to prevent
injury. damage to the pump.
Warning
If these instructions are not observed,
it may lead to electric shock with
consequent risk of serious personal
injury or death.
If these safety instructions are not
Caution observed, it may result in malfunction
or damage to the equipment.
Notes or instructions that make the job
Note
easier and ensure safe operation.

2. System sizing
Warning
The system in which the CM Booster is
incorporated must be designed for the
maximum pump pressure.
The default setting will cause the pump
Caution not to stop until it reaches its maximum
pressure.

2
7. Fault finding

Warning

Fault Finding
Before starting work on the pump, make sure that the power supply has been switched off
and that it cannot be accidentally switched on.

Fault Cause Remedy

1. The green "Power a) The fuses in the electric installation Replace the fuses. If the new fuses
on" indicator light is have burnt. also burn, check the electric
off. installation.
b) The earth leakage circuit breaker or
the voltage-operated circuit breaker Cut in the circuit breaker.
has tripped.
c) No power supply. Contact the power supply company.
d) The PM unit is defective. Repair or replace the PM unit.
2. The green "Pump a) The power supply to the pump is Check the plug and cable connections,
on" indicator light is disconnected after the PM unit. and check if the built-in circuit breaker
on, but the pump of the pump is switched off.
does not start.
b) The motor protection of the pump
Check if the motor/pump is blocked.
has tripped due to overload.
c) The pump is defective. Repair or replace the pump.
d) The PM unit is defective. Repair or replace the PM unit.
3. The pump does not a) Too big difference in height between Adjust the installation, or select a PM
start when water is the PM unit and the tapping point. unit with a higher start pressure.
consumed.
b) The PM unit is defective.
The "Pump on" Repair or replace the PM unit.
indicator light is off.
4. Frequent a) Leakage in the pipework. Check and repair the pipework.
starts/stops.
b) Leaky non-return valve. Clean or replace the non-return valve.
c) A valve close to the PM 1 outlet has
Open the valve.
been closed.
5. The pump does not a) The pump cannot deliver the
Replace the pump.
stop. necessary discharge pressure.
b) A PM unit with too high start Select a PM unit with a lower start
pressure is installed. pressure.
c) The PM unit is defective. Repair or replace the PM unit.
d) The non-return valve is stuck in
Clean or replace the non-return valve.
open position.
6. The red "Alarm" a) Dry running. The pump needs water. Check the pipework.
indicator light is
b) The power supply to the pump is Check the plug and cable connections,
permanently on.
disconnected after the PM unit. and check if the built-in circuit breaker
of the pump is switched off.
c) The motor protection of the pump
Check if the motor/pump is blocked.
has tripped due to overload.
d) The pump is defective. Repair or replace the pump.
e) The PM unit is defective. Repair or replace the PM unit.
7. The red "Alarm" a) Cycling. A tap has not been closed
indicator light is entirely after use. Check that all taps have been closed.
flashing.

3
Fault Cause Remedy

8. The pump a) Pump inlet pressure too low. Check the inlet conditions of the pump.
Fault Finding

performance is
b) Suction pipe is partly blocked by
unstable. Remove and clean the suction pipe.
impurities.
c) Leakage in suction pipe. Remove and repair the suction pipe.
d) Air in suction pipe or pump. Vent the suction pipe/pump.
Check the inlet conditions of the pump.
9. The pump runs a) Leakage in suction pipe. Remove and repair the suction pipe.
backwards when
b) Foot or non-return valve defective. Remove and clean, repair or replace
switched off.
the valve.
c) The foot valve is stuck in completely Remove and clean, repair or replace
or partly open position. the valve.

Self-priming pumps only:

10. The pump a) The differential pressure across the


Close the tap gradually until the
performance is pump is too low.
discharge pressure is stable and the
unstable and the
noise has ceased.
pump is noisy.
11. When startup is a) Liquid column above non-return Empty the discharge pipe. Make sure
attempted, the valve in discharge pipe prevents the that the non-return valve does not hold
pump will start, but pump from self-priming. back liquid in the discharge pipe.
delivers no Repeat the startup procedure.
pressure or flow. Make sure that the suction pipe is
b) Suction pipe draws in air.
airtight from pump to liquid level.
Repeat the startup procedure.
12. The pump runs, but a) The internal valve did not close. Close the tap gradually until the
does not deliver pressure or flow suddenly increases.
the rated flow. Then open the tap gradually until the
required flow is reached.
13. The pump a) Pump inlet pressure too low. Check the inlet conditions of the pump.
performance is
b) Suction pipe is partly blocked by
unstable. Remove and clean the suction pipe.
impurities.
c) Leakage in suction pipe. Remove and repair the suction pipe.
d) Air in suction pipe or pump. Vent the suction pipe/pump.
Check the inlet conditions of the pump.
14. The pump runs a) Leakage in suction pipe. Remove and repair the suction pipe.
backwards when Remove and clean, repair or replace
b) Foot or non-return valve defective.
switched off.
the valve.
c) The foot valve is stuck in completely Remove and clean, repair or replace
or partly open position. the valve.

Self-priming pumps only:

15. The pump a) The differential pressure across the


Close the tap gradually until the
performance is pump is too low.
discharge pressure is stable and the
unstable and the
noise has ceased.
pump is noisy.
16. When startup is a) Liquid column above non-return Empty the discharge pipe. Make sure
attempted, the valve in discharge pipe prevents the that the non-return valve does not hold
pump will start, but pump from self-priming. back liquid in the discharge pipe.
delivers no Repeat the startup procedure.
pressure or flow. Make sure that the suction pipe is
b) Suction pipe draws in air.
airtight from pump to liquid level.
Repeat the startup procedure.

4
Fault Cause Remedy
17. The pump runs, but a) The internal valve did not close.

Fault Finding
does not deliver pressure or flow suddenly increases.
the rated flow. Then open the tap gradually until the
required flow is reached.

8. Disposal
This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or privat e waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.

Subject to alterations.

5
6
CMSP-PM1 Pictorial Diagram
CMSP-PM1 Pictorial Diagram

7
8
CMSP-PM1 Pictorial Diagram
CMSP-PM1 Pictorial Diagram

9
10
CMSP-PM1 Pictorial Diagram
CMSP-PM1 Pictorial Diagram

11
CMSP-PM1-0315
Subject to alterations.

Cert No.: KLR 0402930

Website : www.grundfos.com
Toll Free No. : 1800 88 PUMP (7867)