Features of fusion model –IDS-2000, MODEL, IDC-1000 & prefabricated modular data center

A. Fusion model-IDS-2000 features:---

1. Sufficient power supplies.


2. Proper all result in higher energy consumption without failure.
3. It’s intergraded the power, cooling, monitoring, cabinets, aisle and cabling system offering a
simple, efficient and reliable one stop solution.
4. The key to Huawei smart modular data is that the solution is prefabricated and pre-tested
for quality in the factory, before deliver on site.
5. The capacity of one module is up to 140kw, which supports up to 48 IT cabinets and can be
installed with dual- row or single- row cabinets for development in different scenarios with
traditional construction products from multiple suppliers lead to complicated deployment
days which requires at least 30 to install.
6. Huawei’s solution needs only 2.6 meters or less and easily adapts to the harshest
environments with modular assembly and a simple construction interface, deployment
takes less than 7 days.
7. Huawei smart modular data center expands quickly in order to rapidly bring new business
online.
8. Huawei smart modular data center supports N+1 and 2N power supply architecture
operations won’t be affected if power supply fails.
9. Air conditioners support a dual input power supply which improves reliability of the cooling
system monitoring signals use net-loop architecture so any node fault will not affect the
normal power supply and signal transmission of smart sensors.
10. The data Centre channel sealing structure provides PUE as low as 1.45 in Shenzhen plus.
11. Huawei modular, integrated UPS even improves the efficiency of low loads A 40% load can
achieve up to 97% efficiency.
12. The integrated UPS can detect the status of inner capacitors, so faults can be quickly located
only the failed module needs to be replaced.
13. Huawei I battery wireless battery management system monitors voltage, internal resistance
and temperature for real time visual management of capacity (SOC) and status health (SOH),
if a battery overheats, the battery breaker will turn off automatically to present a fire.
14. Huawei cooling system has a patent for non-condensation at low load rates makes de-
humidification possible even with only a 10% load.
15. For traditionally cooling systems, the air conditioner stops running at low load rates so
humidity can rapidly increase and may interrupt business operations.
16. Linkage with real-time adjustment of cooling capacity as load rates changes.
17. Traditional cooling systems don’t have a linkage between cooling & power which often
delays adjustments, creating excessive energy consumption.
18. Huawei solution allows customers to use smart tablets to perform mobile real time
inspection on site instead of manual operations.
19. Visualization is a key advantage to simplify faults detection maintenance is modularized for
key components .for example a faulty air conditioning fan can be updated online.
20. ECC monitoring can upload real time information to management system to easily manage
and operate multi-DATA-center.
21. Huawei has re-searched and development centers around the world to develop all the
components for Fusion module -2000 smart modular data Centre and has received high
recognition from our global customers.

B. HUAWEI IDS-1000 MODEL-features:-

1. Cloud power data center facility.


2. High PUE, low energy efficiency.
3. Inflexible structure over investment.
4. Inefficient management and maintenance.
5. Pre-engineering, high integration.
6. Self-moving, fast deployment.
7. Cluster combination, flexible expansion.
8. Super adoptability, high efficiency.
9. Friendly customization, hybrid for ICT.
10. Standard 40ft ISO shipping container invigilated external interface, easy to transport &
deploy.
11. Unique design of the porch the external environments and IT apartment are isolated.
12. Container wall is built in polyurethane isolation layer 75mm thickness for the roof 40mm
13. Reliable damping system efficiency reducing the impact on IT equipment during transport
14. Reinforced rack structure static load 1200kg.
15. Air cooled DX precise 12.5 kW cooling capacity with 4+1 redundancy humidification system
is optional.
16. Cables are the above the ceiling and all the pipes are under the floor effectively avoiding the
impact of the condensate water.
17. Double lighting protection system meeting the IEC6132-1992 standard.
18. The energy store rack UPS has the high efficiency of 94.5% battery back-up times is
15minute with 3+1 redundancy.
19. 6s of alarm delay time 8s of extinguishing time.
20. Back up time more than 48hours.
21. The hepta –fluropropane is reliably to put out the fire with only 8% concentration.

C. pre-fabricated modular data center features:-


1. 1.1MW data center deployment.

2. Rapid schedule drove a containerized solution for ease of shipping and site construction.

3. Tier 3rd certification was a mandatory requirement as well as high energy efficiency targets.
4. Power, IT and battery modular 4*500KVA, N+1 UPS configuration bus bar distribution system
high efficiency.

5. Pre-fabricated modular include power, bus bar distribution system, IT equipment and
batteries.

6. Designed and delivered in 6 months.

NOTE: - Conclusion: { AS PER FEATURES }

1. FUSION –MODEL-IDS-2000: 1ST PREFERENCE.


2. IDC-1000 MODEL: 2ND PREFERENCE
3. PRE-FABRICATED MODULAR DATA CENTRE: 3RD PREFERENCE