You are on page 1of 3

6. A column section ISHB 350 @ 661.2 N/m No. of Printed Pages : 05 Roll No. .......................

(A = 8591 mm2 D = 350 mm, bf = 250 mm,


tf = 11.6 mm, tw = 8.3 mm) carries a factored F-72
axial compressive load of 1650 kN and a
factored bending moment of 90 kNm. Design B. Tech. EXAMINATION, May 2018
the base plate and its connections. 15 (Sixth Semester)
(B. Scheme) (Main & Re-appear)
Section D
(CE)
7. A 2014-T6 aluminium wide flange beam is CE304B
connected to columns at its ends by means of
DESIGN OF STEEL STRUCTURE I
framed connections. The section (H = 250 mm,
B = 200 mm, tf = 9 mm, tw = 6.7 mm, Time : 3 Hours] [Maximum Marks : 75
Iy = 8575000 mm4, Ip = 120000 mm4) is over
the effective span of 5 m. If the beam is Before answering the question-paper candidates
laterally restrained at mid span also, determine should ensure that they have been supplied to correct
and complete question-paper. No complaint, in this
the safe uniformly distributed load the beam
regard, will be entertained after the examination.
can carry. Permissible stress in material stess
in material may be taken as 150 MPa. 15 Note : Attempt Five questions only which carry
equal marks. However, a student should
8. A column consists of two 2014-T6 aluminium attempt at least one question from every
channel back to back at a distance of Section. Use of Indian standards is allowed.
180 mm between them (A = 4740 mm2, Any data if missing can be suitably assumed.
Use of scientific calculator is allowed.
M-F-72 4 (3-50/3) M-F-72 P.T.O.
Section A with one line of 20 mm diameter bolts with
ultimate tensile stress 800 MPa and net thread
1. Draw idealized stress streain curve for mild
stress area 245 mm2. 15
steel and discuss the effect of residual stresses.
Discuss four states of each limit state of 4. A column ISHB 300 @ 576.8 N/m
collapse and serviceability. 15 (A = 7485 mm2, bf = 250 mm and tf = 10.6 mm)
is to support a factored load of 900 kN. The
2. A 120 mm diameter and 6 mm thicks pipe is
column section is to be spliced at a height of
fillet welded to a 14 mm plate. It is subjected
2.5 m. Design the spice plate and connections
to a vertical factored load of 4.5 kN at 1 m
using 4.6 grade bolts. 15
from the welded end and a factored twisting
moment of 1.8 kNm. Design the joint assuming Section C
welding and steel of grade FE410. 15
5. Design a load carrying stiffner for a factored
Section B load of 1000 kN for the section ISLB 400.
Stiffener plate may be taken 6 mm with yield
3. Design a bridge truss diagonal subjected to a
strength 250 MPa. 15
fiatored tensile load of 300 kN. The length of
the diagonal is 3 m. The tension member is
connected to a guessest plate 16 mm thick

M-F-72 2 (3-50/4) M-F-72 3 P.T.O.


B = 77.4 mm, rx = 112.4 mm, ry = 19.8 mm, B = 77.4 mm, rx = 112.4 mm, ry = 19.8 mm,
Ix = 1860000 mm4, Ip = 61960000 mm4. If Ix = 1860000 mm4, Ip = 61960000 mm4. If
the effective length of the column is 10 m, the effective length of the column is 10 m,
determine the axial load of the column and determine the axial load of the column and
design suitable lacing for it. 15 design suitable lacing for it. 15

M-F-72 5 870 (3-50/5) M-F-72 5 870