www.dv-power.com 1
The IBEKO Power company (brand name: DV Power),
headquartered in Sweden, is a leading company in design and
manufacturing of portable test equipment for electrical energy
systems, power and industrial plants, electrical substations,
etc.
Its success is solely based on extensive research, development
and fast commercial application.
IBEKO’s DV Power program is the complete range of
instrument sets for testing power transformers, generators,
motors, circuit breakers and isolators, industrial batteries.
These products are being used in more than 80 countries. The
list of the customers includes companies such as ABB of ABB,
Siemens, SGB-SMIT and other world renown corporations.
Batteries are crucial components of the overall reliability of a substation. Inability of a battery string to provide a sufficient
voltage / power supply to protection circuits may lead to catastrophic consequences to the substation equipment resulting
in a power outage.
Listening to the demands of the test engineers from all around the world, we developed state-of-the-art battery testing
and monitoring solutions to meet customer’s wide ranging test procedures (standardized as well as customized).
The essential test for a condition assessment of a battery string is the capacity test. This and tests of many other battery
string parameters are made possible with our user-friendly sets of instruments, as presented in the table below.
With this set of instruments, a user can collect, analyze and present various
battery status information, such as
Instrument BLU/BXL BVS BVR IBAR BAC25A
Series Series Series
Parameter
Capacity •
Cell voltage • •
Intercell connection voltage • •
Internal resistance *Provided in combination
measurement (AC test method) • of BLU and BVS devices
Internal resistance calculation All devices except BAC25A
(DC test method) * • • from this portfolio include
DV-B Win set of software
Cell/ambient temperature
measurement • • application tools providing
data acquisition, storing,
analysis and reports
Recharging procedure • generation.
www.dv-power.com 3
Battery Load Unit (BLU)
The Battery Load Units - BLU series are stand-alone or PC-controlled battery capacity test set, based on a state-of-the-art
technology, using the most advanced power electronics solutions with coolers and fans integrated into device.
The BLU series are portable solutions developed to meet customer’s wide ranging test procedures (standardized according
to IEEE, IEC, etc. as well as customized).
Discharging can be performed at constant current, constant power, constant resistance or in accordance with a pre-selected
load profile.
Discharge parameters can be monitored in real-time on 4,3 inch (BLU100A, BLU110T, BLU220T, BLU200A, BLU340A,
BLU360V) or 7 inch display (BLU200C, BLU500V) as well as on a PC (if the DV-B Win software is used).
Main Features
Overview of the BLU Series devices maximum currents for various battery voltage ranges with the minimum achievable
battery voltage of 5,25 V is presented in the table below. Maximum currents available by using BXL series devices are also
presented in the table.
5,25 59 74 11
6 40 60 50 100 100 50 60
7,05 80 100 15
10,5 119 156 26
12 80 120 100 150 200 100 120
14,1 160 210 35
21,0 186 230 55
24 160 240 160 150 340 160 240
28,2 250 310 75
42,0 186 230 115
48 160 240 160 150 340 160 240
56,4 250 310 155
52,5 81 185 141
60 120 210 160 120 270 160 240
70,5 110 250 190
96,3 119 96
110 110 130 160 - - - 160 140
129,3 160 130
105,0 134 107
120 100 140 150 - - - 150 140
141,0 180 145
192,5 67 85
220 55 75 110 - - - 110 75
258,5 90 115
210,0 67 93
240 50 70 100 - - - 100 70
282,0 90 125
300,0 34
65 45
410,0 46
480
410,0 46
- - - - - - - 55 40
500,0 55
Weight 12,8 / 14,5 / 20,6 / 12,5 / 12,8 / 15,1 / 12,5 / 20,6 / 16,5 / 16,0 /
(kg / Ibs.) 28.2 32.0 45.4 28.0 28.2 33.0 28.0 45.4 36.4 35.0
Max Power
14,2 19,7 28,4 25,4 8,5 19,2 17,9 28,4 20,0 35,0
(kW)
www.dv-power.com 5
Battery Extra Load Unit - BXL Series
If a required discharge current or power exceeds the capacity of a BLU device, the Extra Load Units BXL series can also be
used to increase a discharging capacity.
Depending on battery voltage and required discharge capacity, one or multiple BXL-T (up to 60 V DC), BXL-A (up to
300 V DC) or BXL-V (up to 500 V DC) units can be connected in parallel with a BLU device. Additionally, a BXL unit can
be used with other discharge units available in the market to increase a discharge capacity.
Discharging process is controlled by a BLU device, by measuring the BXL current with a current clamp. Before starting the
discharging, the BXL enables its load capacity setting by selecting one of the available resistance values. Offered resistance
values depend on a voltage of a battery BXL is connected to.
Main Features
The device is used during charging/discharging process. When used in a combination with the BLU series it serves as an
efficient supplement to battery capacity testing. Also it can be used with any other load bank in the market, using additional
String Voltage Module (SVM) and String Current Module (SCM) in user-selected sampling rates. An additional BVS feature
is the internal resistance calculation. This is available in a combination with BLU Series.
Data acquisition and extensive analysis tools are available in the DV-B Win software application set.
Quick and easy data import from IBAR to PC is provided by DV-B Win software. The
measurement data and battery information can be stored and archived with the DV-B
Win software and can be used to compare results and perform trend analysis.
Main Features
www.dv-power.com 7
Technical Specification Battery Voltage Recorder BVR11 Battery Voltage Recorder BVR22
DV Power battery test instruments include DV-B Win software application tools based on the Windows operating system,
providing friendly user interface as well as data management features (data acquisition, test control, test result analysis,
report generation), as shown in the figures below.
Main Features
• User interface
• Test monitoring and control
• Test data acquisition
• Previous test cases data import
• Data management
• Data analysis
• Data export
• Report generation
• Battery monitoring and trending
Main Features
Technical Specifications
Mains Voltage Voltage Current Boost voltage (V DC) Float voltage (V DC)
(V AC) (V DC) (A DC)
Lead-Acid Ni-Cd Lead-Acid Ni-Cd
12 Up to 25 14 15 13 14
24 Up to 25 29 30 27 28
48 Up to 25 57 60 54 56
60 Up to 25 72 75 68 70
230/115 Up to 20 (230 V)
110/120 133/145 140/150 125/135 130/140
Up to 10 (115 V)
Up to 10 (230 V)
220/240 263/290 275/300 148/270 250/280
Up to 5 (115 V)
www.dv-power.com 9
ACCESSORIES
Current cables with aligator Extension cables Sense cables with dolphin Cable set for BLU-BXL
clamps (A4) isolated clips parallel operation
Cable for BLU-BLU Current probe 30/300 A Cable bag Transport case
parallel operation
Voltage sense cables (BVR) Voltage Sense cables for Communication cable for Current clamp 30/300 A
CVM (BVS) CVM (BVS) (BVR and BVS)
BAC
Circuit breaker test devices are robust and field-portable instruments with local or PC controlled functionality. This
set of instruments provides powerful measurement tools during manufacturing, commissioning, and maintenance phases of
a circuit breaker and disconnector life span.
The essential part of a circuit breaker condition assessment is the ability to compare to compare the latest with previous
test results. Measured values are stored and compared with the limits specified by the manufacturer. A fingerprint obtained
in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain accurate
comparison, the tests need to be performed using identical test parameters. Any deviation and change in the test results
may indicate the circuit breaker condition deterioration. This ability is supported by the DV-Win test plans and graph
overlay features.
CAT35
CAT36
CAT31 CAT34 CAT64A CAT65
RMO POB SAT CAT03 CAT-P
CAT61 CAT64 CAT124A CAT66
CAT125
CAT126
Contact Resistance • •
DRM •
Coil Resistance • •
Coil Current • • • • • • •
Motor mechanism
charging time • • • • •
Minimum trip voltage • •
Timing of circuit breaker
main and resistor • • • • • •
contacts
Timing of circuit breaker
auxiliary contacts • • • • •
Synchronization between
the contacts • • • • • •
Motion and velocity • • •
“First trip” test • • • •
www.dv-power.com 11
RMO Series – Micro Ohmmeters
The RMO series of instruments are designed for contact resistance measurement of non-inductive test objects. Based on
the most advanced switch mode technique available today, the RMO series of instruments generate a true DC ripple-free
current with automatically regulated test ramps.
RMO-A SERIES RMO-G SERIES RMO-D SERIES RMO-H SERIES RMO-E SERIES
Powerful and lightweight Micro Ohmmeters with Micro Ohmmeters with Handheld Micro Ohmmeters Protective Earth
Micro Ohmmeters with Both Sides Grounded feature Both Sides Grounded and Resistance Meters
IP43 protective rating Demagnetization features
The RMO-A series models are the “entry level” of the RMO devices, but not much less potent than the remaining series of
the RMO devices. It includes six different models placed in the metal housing. The main difference between these models
is the maximum test current that can be generated.
RMO600A
The RMO-G series includes seven models mounted in plastic housings. Comparing to RMO-A series, there are additional
"Both Sides Grounded" and "Remote Control" features available as options.
RMO200G
The RMO-D series instruments are the most advanced version of the RMO family of instruments with the built-in High
Precision module which provides an increased precision and offers a highly accurate contact resistance measurement in the
range from 1 µΩ to 30 µΩ, with 0,01 µΩ resolution. The additionally offered feature is the ability to perform fully automatic
demagnetization of a current transformer core after the measurement.
The demagnetization feature implemented in the RMO-D series does not require any modifications or
additional connections; it is automatic and very quick. In a combination with DTRtest, it provides the
simplest and the most efficient testing of dead tank circuit breakers compared with any micro ohmmeter
on the market.
RMO600D
Demagnetization Feature
After the contact resistance measurement of dead tank circuit breakers, it is necessary to demagnetize the CT cores. This
is because a DC current used for this measurement flows directly through the current transformers (CTs) mounted on the
bushings. Causing that some amount of magnetic flux is probably trapped in the current transformer core. The remnant
magnetism can cause various problems such as erroneous diagnostic electrical measurements on a CT or an incorrect
operation of protective relays.
Demagnetizing magnetic core of a transformer requires alternating current applied with decreasing magnitude down to
zero. By reducing the magnitude of the applied current to the zero value, the total magnetic flux, or remnant magnetism, is
also annulled. The RMO-D provides this alternating current by internally changing the polarity of a controlled DC current
source. During the demagnetization process the instrument supplies current at decreasing magnitude at each step, following
a proprietary developed solution algorithm.
www.dv-power.com 13
Protective Earth Resistance Meters – RMO-E Series
The RMO-E is ideal for testing the protective bonding (grounding) of equipment using the
test current of up to 100 A DC, following the standard 61010-1 IEC 2001 requirements.
Besides this application, RMO-E can be used for contact resistance measurement of non-
inductive test objects (e.g. circuit breakers, disconnector switches, bus bars, etc.). The set
is equipped with the thermal and overcurrent protection. During a test the RMO-E ramps
with increasing current before measuring and decreasing current after the measurement.
This significantly decreases magnetic transients.
DTRtest – A New Test Mode for Dead Tank Circuit Breakers Testing
Presence of current transformers (CT) on the dead tank circuit breakers may introduce errors during the contact
resistance measurement due to CT magnetizing process. For this reason, it is necessary to saturate a CT prior to starting
a measurement.
DTRtest menu is specially designed for resistance measurement of the dead tank circuit breakers and it is implemented in
all three series of our micro ohmmeters – RMO-A, RMO-G and RMO-D series. All calculations for detecting the saturated
condition of CTs are done by internal algorithm. Accordingly, the process of setting the measurement parameters and
conducting a test in this mode. is very simple and does not differ much from a live tank circuit breaker testing.
The high-precision module is newly developed built-in addition to our RMO-D micro ohmmeters (for RMO-G series it is
available as an option). It provides an increased precision and offers a highly accurate contact resistance measurement in the
range from 1 µΩ to 30 µΩ, with 0,01 µΩ resolution.
Our RMO-G and RMO-D devices with this built-in High Precision Module may be used for applications on very small
resistance measurements of non-inductive test objects. This requirement is usually met at resistance inspections of generator
circuit breakers, welding joints, GIS testing, etc.
The RMO-H devices as well as the RMO-G and RMO-D series instruments
have the possibility to perform measurements with both sides of a test object
grounded. This will ensure the operator's safety and protect the instrument
as well.
First handheld micro ohmmeter (only 0,95 kg / 2.1 lbs) which generates regulated DC current up to 300 A! The RMO-H
micro ohmmeters are ideal for a number of applications for contact resistance measurements of non-inductive test objects.
Typical applications are testing a circuit breakers and disconnecting switches, high-current bus bar joints, cable splices,
welding joints, etc.
www.dv-power.com 15
CAT series - Circuit Breaker Analyzers and Timers
CAT devices are either standalone or PC controlled digital instruments for circuit breakers’ condition assessment. The
robust design incorporates cutting edge technology with latest enhancements for safe and fast testing of medium or high-
voltage circuit breakers with live or dead tank design.
The user can select any desired operational mode: Close (C), Open (O), Close-Open (C-O), Open-Close (O-C), Open-
Close-Open (O-C-O). Test results can be stored in the instrument’s internal memory, a USB memory stick or printed on
a thermal printer (optional accessory) in both, tabular and graphical form.
CAT I Series
The first series of CAT instruments are designed to meet requirements of an easy to use circuit breaker analyzer &
timer with an attractive price. Their primary intention is timing and motion measurement of HV and MV circuit breakers.
BSG (Both Sides Grounded) feature enables safe and fast testing in high voltage substations, without removing the
safety ground connections on both sides of the circuit breaker. No additional modules or remote boxes are required. Each
main contacts timing channel is able to detect main contacts state in casees when both terminals are grounded.
www.dv-power.com 17
Static/Contact Resistance Measurement
Very high output power (output voltage multiplied with output current)
of our micro ohmmeters enables two main advantages:
Auxiliary contacts
timing channels 6 6 6
Transducer input
channels
3 3 3
Thermal printer
(built-in)
Optional Optional Optional
Dynamic resistance
measurement
YES NO / YES / YES NO / YES / YES
18 DV Power Products Catalog
CAT-P - Handheld Circuit Breaker Analyzer and Timer
Handheld Circuit Breaker Analyzer & Timer CAT-P is a digital instrument for circuit breakers condition assessment. It can
be used in an offline mode to measure the main contact times when the circuit breaker is isolated from the network or in
online mode when the circuit breaker is connected to the network.
Offline testing: CAT-P and Coil Control Module Online testing: CAT-P connection to live tank circuit
connection to dead tank circuit breaker with one breaker with one breaking element per phase.
breaking element per phase.
www.dv-power.com 19
POB series – AC / DC Power Supply for Circuit Breaker Testing
The Coil Tester & Power Supply POB series instruments are powerful, lightweight, variable voltage power supply units ideal
for testing circuit breakers where substation battery is not connected or available. They are intended for operating breaker
coils and spring-charging motors in commissioning and maintenance testing. These devices are compatible with breaker
analyzers from different vendors and eliminate use of station batteries during testing.
With their unique features, and in combination with the CAT series of device, SAT
devices provide a complete diagnostics of a circuit breaker, while greatly reducing the
test duration. SAT40A’s powerful motor output can provide you with 40 amps ramp up current, either AC or DC. They are
compatible with breaker analyzers from other vendors as well. A robust design makes these instruments well suited for use
in a varietyof harsh environments.
The SAT series provide also a Coil Resistance Measurement, and is equipped with an AC motor supply output.
www.dv-power.com 21
SAT Series Motor Output
SAT30A SAT40A
Mains Voltage Load voltage Max load interval Max Current Max Current Max Current
@ Motor Output @ Motor Output @ AC Motor
(DC) 30 Amps (DC) 40 Amps Output
40 Amps
20 sec 24 A 30 A 15 A (10 sec)
230 V
60 sec 20 A 24 A 10 A (contin)
110 V
20 sec 12 A 15 A 12 A (10 sec)
120 V
60 sec 7A 12 A 8 A (contin)
20 sec 12 A 12 A 12 A (10 sec)
230 V
60 sec 10 A 10 A 6 A (contin)
220 V
20 sec 7A 7A 15 A (10 sec)
120 V
60 sec 6A 6A 10 A (contin)
CAT SERIES
Main contact cables with SCT Main contacts extensions Coil control cable with Coil supply cable set with
clamps (two breaks per phase) cables banana plugs banana plugs
Current cables with battery Sense cables with alligator Cable bag Transport case
clamps clamps
Cable plastic case with wheels First trip test kit Current DC clamp 30/300 A AC Current clamp 1 A / 1 V
Linear analog transducer Doble transducer adapter Universal transducer Digital rotary transducer
mounting kit and digital
transducer with accessories
www.dv-power.com 23
POB SERIES
RMO SERIES
Current cables with battery Extension current cables Sense cables with alligator
clamps clamps
Current cables and Sense Current cables with battery Sense cables with alligator
cables with TTA clamps clamps clamps
Current cables and Sense Transport case with included Screws for current cables
cable with Kelvin probes device accessories and cables connectors and Carrying strap
www.dv-power.com 25
TRANSFORMER TEST EQUIPMENT
Various diagnostic tests can be performed on power and instrument transformers using the DV Power instruments.They
include DC current tests (winding resistance measurement and tap changer analysis), as well as AC voltage tests (transformer
turns ratio, excitation current measurement, phase angle measurement, vector group detection).
DV Power transformer test instruments also use the DVtest method for on-load tap changer testing – a unique specialized
non-intrusive method for the tap changer analysis. In addition, the automatic transformer demagnetization function is
deployed removing effects of a magnetized transformer core and minimizing the transformer inrush current. DV Power
tap changer analyzers also include a dedicated AC/DC current measurement channel used for monitoring the tap changer
motor current during the tap changer operation.
Applications supported by DV Power transformer test equipment include:
Model 100TT 60TT 40TT 60TD 40TD 25TD 50TW 30TW 20TW 10TW
Maximum test current 100 A 60 A 40 A 60 A 40 A 25 A 50 A 30 A 20 A 10 A
Temperature
4 1 1
measurement channels
Resistance measurement
3 3 3
channels
DVtest sampling
0,1 ms 0,1 ms 4 ms
resolution
Tap changer motor
YES YES NO
current measurement
Demagnetization YES YES YES
Automatic discharge
YES YES YES
function
Vibration testing YES NO NO
Built-in tap changer
YES YES NO
control unit
USB Flash drive YES YES NO
Thermal printer (built-in) Optional Optional Optional
Accuracy ±(0,1% rdg + 0,1% F.S.) ±(0,1% rdg + 0,1% F.S.) ±(0,1% rdg + 0,1% F.S.)
Tap Changer & Winding Analyzer TWA40D is one-of-a-kind diagnostic solution for power transformer testing.
Using this device, the transformer testing is safer, significantly faster, and more convenient. The TWA40D
instrument is designed for simultaneous three-phase tap changer analysis and six-winding resistance measurement
of both, the primary and the secondary transformer windings. Each vector group has a special measurement
algorithm that is optimized for the fast stabilization of test results.
Measurements are obtained very quickly by saturating the magnetic core through the HV and LV windings at
the same time. Once all 6-8 bushings are connected and the transformer configuration selected, the instrument
adjusts the test procedure automatically. The TWA40D generates a true DC ripple-free current. The Current
injection and discharge of energy from the magnetic circuit are both automatically regulated.
Dynamic resistance graphs are recorded for all three phases simultaneously, so the synchronization is verified using the
cursors provided in the DV-Win software. All three phase traces are plotted on the same graph. In addition, the tap changer
motor current is recorded and displayed on the same graph. The measurement is completed quickly even on the largest
power transformers.
The TWA40D instrument can perform three-phase demagnetization after the DC test is finished. The process is completely
safe, fully automated and very fast. This enables the user to avoid problems such as high inrush currents at the start-up of
power transformers, incorrect operation of protective relays, erroneous diagnostics or inaccurate electrical measurement
on a transformer.
The test cables used for the measurement are completely compatible with the DV Power TRT series of Three-Phase
Transformer Turns Ratio Testers. This enables the user to measure using a one-time test leads setup:
The TWA25A is a simplified version of the TWA40D model, specifically focused on the three-phase winding resistance
measurement. The differences between the TWA25A and TWA40D models are listed in the table below.
TWA40D TWA25A
Six-winding resistance
YES YES
measurement
5 mA – 25 A (up to 25 A for winding
resistance measurement and up to
DC test current 5 mA – 25 A
40 A for the 3-phase synchronization
test)
Measurement accuracy ± (0,1 % rdg + 0,1 % FS) ± (0,1 % rdg + 0,1 % FS)
Simultaneous 3-phase winding
YES (Quick YN test) NO
resistance measurement
DVtest sampling resolution 0,1 ms 4 ms
Simultaneous 3-phase DVtest YES NO
Tap changer motor current
YES NO
measurement
www.dv-power.com 29
DVtest – On-Load Tap Changer Analysis using DV Power Instruments
The TWA40D instruments enable simultaneous OLTC testing of all three phases in a single pass
through the tap positions. In this manner, the total OLTC testing time is greatly reduced, by two thirds
in comparison with the classic methods. This test procedure also enables observing the synchronization
problems between the different phases.
The Quick YN test is a unique DV Power proprietary measurement method which enables performing
the measurements of three winding resistances on a tap changer in YN configuration at the same time,
and measuring the resistances in all tap positions in all three phases with a single pass through the tap
positions. TWA40D is the only instrument in the market with this capability, which can significantly
reduce the time required for a full winding resistance test.
The static resistance measurement provides winding resistance values at every tap position for
each of the three phases. There is no need to discharge the transformer between the measurements in
different tap positions. The DV-Win software creates the static resistance graph from the results of the
resistance measurement in different positions, as well as the automatic recalculation of the measured
values to a reference temperature value. The shape of the static resistance graph depends on the
winding regulation mode.
The AC current monitoring channel enables monitoring and recording the OLTC mechanical-drive motor current
during the tap changer operation. The motor-current waveform is also printed on the same DV-Win-generated graph, and
can help in detecting OLTC mechanical problems.
All the TRT devices are equipped with a tap changer control unit that allows changing tap positions remotely, and even
automatically. USB Flash Drive feature enables saving all the test results to a USB memory stick. DV Power provides 112
mm built-in thermal printer as an option.
Main Features
Setting up the TRT is as simple as connecting it to de-energized transformer and selecting one of the following two
approaches, or both of them, to test the three-phase transformer:
SEQUENTIAL 3~ – Three single-phase voltages are applied to the three transformer primary windings, and all three
phases are measured consecutively (phase by phase). All connections and short circuit procedures at the primary and
secondary voltage terminals are done automatically and internally before each measurement, depending on the selected
vector group. Over 130 different transformer and autotransformer configurations can be tested this way. A user provides
only a transformer’s configuration data and the predefined measurement procedure is automatically applied by the
instrument itself. If the (auto) transformer configuration is not available, the TRT can automatically detect it using its built
in proprietary algorithm.
SIMULTANEOUS 3~ – A true three-phase excitation voltage is applied to the three transformer primary windings.
Three induced phase voltages are measured at the same time. In such a way it is possible to detect the phase angle and
measure the turns ratio of any transformer type, including phase shifting transformers, where other “three-phase” turns
ratio testers cannot.
TRT devices are divided into 4 series, based on the maximum test voltage and test voltage source. The TRT63 series has
the highest test voltage of 250 V, making it the most accurate on the market.
* Combined with Extension Transformer CVT40 it can output 5 kV AC single-phase, specially for
testing capacitive voltage transformers, see the next page
www.dv-power.com 31
CVT40 – Extension transformer
CVT40 is an extension single-phase transformer which, in combination with DV Power TRT4x series devices, can increase
the TRT4x output voltage 40 times, up to 5 kV AC. This combination is specifically developed for testing turns ratios of
capacitive voltage transformers.
Main Features
The demagnetization process with DEM60C instrument is completely safe, fully automated and fast. The instrument
generates an alternating current applied with decreasing magnitude down to zero. This option is implemented by internally
changing the polarity of a controlled DC current.
Main Features
The Motor & Generator Winding Ohmmeter instruments are designed to measure the winding resistance of electrical
motors and generators. Instruments generate a true DC ripple free current with automatically regulated measurement and
discharging circuit.
32 DV Power Products Catalog
ACCESSORIES
TWA SERIES
H & X winding test cable set Current clamps Tap changer control cable Transport case
(used with TWA40D)
TRT SERIES
H & X winding test cable set Bluetooth communication Tap changer control cable Transport case
module
Current and sense cables with Sense cables with TTA Current connection cable Tap changer control cable
TTA clamps clamps with TTA clamps (used with RMO-TD and
RMO-TT)
Current clamps (used with Temperature sensor Transport case (used with Transport case
RMO-TD and RMO-TT) RMO-TD and RMO-TT) (used with RMO-TW)
DEM60C
• Technical support
• Product maintenance and calibration
• Feature upgrades
• Training
• Webinars
• Seminars
DV Power has a worldwide network of representatives providing local customer support for sales and after-sales
enquiries. Please visit us online to find more information about your local contact:
http://www.dv-power.com/distributors/
Contact
E-mail
support@dv-power.com
Equipment service
www.dv-power.com 35
Smar t test devices
for reliable electric
power systems
Postal Address
IBEKO Power AB
Box 1346
181 25 Lidingö
Sweden
Delivery Address
IBEKO Power AB
Stockholmsvägen 18
181 50 Lidingö
Sweden
sales@dv-power.com
Support Contact
E-mail
support@dv-power.com