1 FCS Error Generation and Recovery Messages


(Message Nos. 0001 to 0099)

No. 0001 Control station reset start


No. 0003 Control station automatic reset start
No. 0005 Control station power on initialization cold start
No. 0007 Control station power on restart
No. 0009 Control station control right transfer
No. 0011 Control station failure information
No. 0013 Control station AC power failure
No. 0015 CPU internal clock self-diagnostic testing error
No. 0017 CPU card ROM sum check error
No. 0021 Control station task internal error
No. 0023 Function block fatal error
No. 0025 Function control word error
No. 0027 Function block record information error
No. 0029 HIS station communication failure
No. 0030 HIS station communication recovery
No. 0033 Online downloading abnormal end
No. 0035 General-purpose calculation block calculation error
No. 0036 General-purpose calculation block calculation error recovery
No. 0037 Block one-shot start error
No. 0038 Recovery from block one-short starting error
No. 0039 Process I/O error
No. 0040 Recovery from process I/O error
No. 0045 Control station power supply unit alarm
No. 0046 Control station power supply unit alarm recovery
No. 0047 Control unit battery alarm
No. 0048 Control unit battery alarm recovery
No. 0055 Online downloading communication same frame received information
No. 0057 Online downloading error information
No. 0069 Error before database downloading to I/O module
No. 0073 Error in bus connected between I/O unit and CPU unit
No. 0074 Normal recovery of bus connecting I/O unit and CPU unit
No. 0075 I/O module error (for AAM/APM)
No. 0076 I/O module normal recovery (for AAM/APM)
No. 0077 I/O module database error (for AAM/APM)
No. 0079 I/O module communication error (for AAM/APM)
No. 0080 I/O module communication error recovery (for AAM/APM)
No. 0081 I/O module error (for ADM/AMM)
No. 0082 I/O module normal recovery (for ADM/AMM)
No. 0083 I/O module database error (for ADM/AMM)
No. 0085 I/O module communication error (for ADM/AMM)
No. 0086 I/O module communication error recovery (for ADM/AMM)
No. 0089 Subsystem communication error
No. 0090 Subsystem communication recovery
No. 0098 System alarm normal recovery
CS 1000 YOKOGAWA

No. 0099 System alarm

2 HIS System Status Messages


(Message Nos. 0201 to 0251)

No. 0201 VL net card error


No. 0203 VL net communication circuit error
No. 0204 VL net communication circuit recovery
No. 0207 Program terminated in an abnormal state
No. 0209 Program execution error
No. 0231 HIS function shutdown
No. 0236 HIS function start
No. 0238 Virtual HIS function test start
No. 0251 HIS system stop by WDT time up

3 Communication Related Messages


(Message Nos. 0301 to 0331)

No. 0301 VL net communication error


No. 0303 Station failure
No. 0304 Station recovery
No. 0305 VL net failure
No. 0306 VL net recovery
No. 0311 HIS communication error
No. 0330 Time adjustment
No. 0331 Network time error

4 Control Station Status Change Related Messages


(Message Nos. 0450 to 0490)

No. 0450 Control station control side program database copy to standby side
No. 0451 Control station control side information
No. 0452 Control station standby side notified
No. 0457 I/O module service side notified (for AAM/APM)
No. 0458 I/O module out service notified ( for AAM/APM)
No. 0459 I/O module service side notified (for ADM/AMM)
No. 0460 I/O module out service notified (for ADM/AMM)
No. 0471 Online downloading normal end
No. 0474 Tag list double-defined error notification
No. 0475 Database downloading to I/O module start
No. 0476 Database downloading to I/O module normal end
No. 0477 Database downloading to I/O module abnormal end
No. 0478 Tuning parameters save normal end
No. 0479 Tuning parameters save abnormal end
No. 0480 Periodic processing overload
No. 0482 Tuning parameters save start successful
No. 0483 Tuning parameters save abnormal start failed
No. 0485 SFC block download error

5 Operation Command and Operation Record Messages


CS 1000 YOKOGAWA

(Message Nos. 0501 to 0663)

No. 0501 Database equalize request


No. 0502 Database equalization completed normally
No. 0503 Database equalization ended with error
No. 0505 HIS restart request
No. 0507 Computer Reset Start Request
No. 0509 System Configuration Warning
No. 0510 Database download
No. 0511 Database download error
No. 0513 DataBase of the project not relevant to the excuting project
No. 0514 Operation and monitoring function database change
No. 0515 Operation and monitoring function database change error
No. 0602 Control station all program copy operation
No. 0603 Control station system reserve operation
No. 0604 Control station system release operation
No. 0605 Control station stopped
No. 0606 Control station started
No. 0607 Program loading to I/O module started
No. 0608 Control station parameters save
No. 0609 Control station download
No. 0635 Process alarm acquisition mode changed
No. 0636 Message acknowledgment method changed
No. 0637 Referenced database changed
No. 0638 User-defined function key changed
No. 0639 Operation mark changed
No. 0640 Multimedia definition changed
No. 0641 Trend display pen assignment changed
No. 0642 Graphic instrument faceplate assignment changed
No. 0653 HIS printer on
No. 0654 HIS printer off
No. 0655 HIS printer assignment change
No. 0656 Buzzer sound output destination changed
No. 0657 Window mode changed
No. 0663 Equalization operation

6 FCS Related Messages


(Message Nos. 0717 to 0751)

No. 0721 SEBOL error (Fatal error: SFC block)


No. 0723 SEBOL error (SFC block)
No. 0725 SEBOL system alarm generation
No. 0726 SEBOL system alarm recovery
No. 0727 Block mode recovery error information
No. 0729 SFC block main program intermediate language downloading error
information
No. 0731 Unit error (unit procedure)
No. 0733 Unit error (SEBOL interpreter)
No. 0749 Self-diagnostic testing error
CS 1000 YOKOGAWA

No. 0750 Self-diagnosis normal recovery


No. 0751 Time self-diagnostic testing error
No. 0753 Communication Overload

7 HIS Peripherals Messages


(Message Nos. 0801 to 0892)

No. 0821 Printer is unavailable


No. 0823 Printer is offline
No. 0825 Printer out of paper
No. 0827 Printer error
No. 0829 Printer undefined
No. 0891 Package error
No. 0892 Package error recovery

8 Process Messages
(Message Nos. 1101 to 1903)

No. 1101 Input process alarm generation


No. 1102 Input process alarm recovery
No. 1103 Output process alarm generation
No. 1104 Output process alarm recovery
No. 1106 Process alarm normal recovery
No. 1107 Process alarm continuation
No. 1111 Unit alarm generation, task alarm generation
No. 1112 Unit alarm recovery, task alarm recovery
No. 1201 Annunciator generation message
No. 1206 Annunciator recovery message
No. 1207 Annunciator generation continuation
No. 1303 Sequence message
No. 1305 SEBOL history statement message
No. 1401 Block mode (loop status)
No. 1403 Alarm off
No. 1404 Alarm on
No. 1405 Block status change information
No. 1407 Data item value change information
No. 1601 Entry operation record
No. 1602 Tag alarm acknowledgment
No. 1603 Block mode change
No. 1604 Function block operation
No. 1605 Alarm off
No. 1606 Alarm on
No. 1613 Function block operation
No. 1641 Operation mark assignment
No. 1642 Operation mark reset
No. 1643 Graphic window data group entry operation
No. 1693 Trend recording start operation
No. 1694 Trend recording stop operation
No. 1695 Trend recording continuation operation
CS 1000 YOKOGAWA

No. 1701 Operation guide message


No. 1711 Dialogue message
No. 1712 Reinput type dialog message
No. 1713 Dialogue cancel
No. 1714 Dialogue time-out cancel
No. 1801 Sequence message request
No. 1902 Supervisory computer event message (for operation and monitoring function
program, device address 3) received
No. 1903 Supervisory computer event message (for computer program, device address
6) received