You are on page 1of 6

NDT TEST REPORT

Laporan Hasil Uji N


NDT
LAB. NON DESTRUCTIVE TESTING QUALITY CONTROL
PT. SIS MEL TRI AERO T

Customer Name & RO/WO : PT NTP Report Number : 002/SMT-AERO/II2018


Nama Customer & RO/WO WO : Nomor Laporan
Part To Be Tested : Bearing #1 Type/Model : N/A
Barang Yang Diperiksa Type/Model
Inspection Method : Ultrasonic Testing Receive Date : 28 Maret 2018
Metoda Pemeriksaan Tanggal Terima
Quantity : 1 set Finish Date : 28 Maret 2018
Jumlah Tanggal Selesai
Program/Reference : Inspection Ref. Manual : MIL-STD 2183 Test Method
Program/Referense Dokumen Ref. Bond Testing Babbit Lined

DESCRIPTION OF TEST
Uraian Hasil Pemeriksaan
INSPECTED USING ULTRASONIC TESTING CTS-9005

Gain : 70,0Db
Step : 2,0
Spath : 150 & 250,0mm
Vel : 5920m/s
Dly : 0,0mm
Zero : 0,00 u s
Rej : 0%

Calibration Process :

Unbounded Bounded

CALIBRATION DUE DATE : AUGUST 30, 2018


RESULT : BOUNDED

Inspected by : Djoko Sumbarto/NDT Level 2


Diperiksa oleh

Note :
Catatan
1. Claim after 3 (three) month from date of issued will not be accepted.
Pengaduan atas hasil uji setelah tiga bulan dari tanggal laporan, tidak diterima.
2. This certificate may not be reproduced, without permission from the head of quality control
Tidak dibenarkan memperbanyak laporan hasil uji, tanpa seijin kepala quality control.
NDT TEST REPORT
Laporan Hasil Uji N
NDT
LAB. NON DESTRUCTIVE TESTING QUALITY CONTROL
PT. SIS MEL TRI AERO T

Customer Name & RO/WO : PT NTP Report Number : 003/SMT-AERO/IV/2018


Nama Customer & RO/WO WO : Nomor Laporan
Part To Be Tested : Bearing #2 Type/Model : N/A
Barang Yang Diperiksa Type/Model
Inspection Method : Ultrasonic Testing Receive Date : 28 Maret 2018
Metoda Pemeriksaan Tanggal Terima
Quantity : 1 set Finish Date : 28 Maret 2018
Jumlah Tanggal Selesai
Program/Reference : Inspection Ref. Manual : MIL-STD 2183 Test Method
Program/Referense Dokumen Ref. Bond Testing Babbit Lined

DESCRIPTION OF TEST
Uraian Hasil Pemeriksaan

INSPECTED USING ULTRASONIC TESTING CTS-9005


Gain : 70,0Db
Step : 2,0
Spath : 150 & 250,0mm
Vel : 5920m/s
Dly : 0,0mm
Zero : 0,00 u s
Rej : 0%

Calibration Process :

Unbounded Bounded

CALIBRATION DUE DATE : AUGUST 30, 2018


RESULT : BOUNDED

Inspected by : Djoko Sumbarto/NDT Level 2


Diperiksa oleh

Note :
Catatan
1. Claim after 3 (three) month from date of issued will not be accepted.
Pengaduan atas hasil uji setelah tiga bulan dari tanggal laporan, tidak diterima.
2. This certificate may not be reproduced, without permission from the head of quality control
Tidak dibenarkan memperbanyak laporan hasil uji, tanpa seijin kepala quality control.
NDT TEST REPORT
Laporan Hasil Uji N
NDT
LAB. NON DESTRUCTIVE TESTING QUALITY CONTROL
PT. SIS MEL TRI AERO T

Customer Name & RO/WO : PT NTP Report Number : 004/SMT-AERO/II2018


Nama Customer & RO/WO WO : Nomor Laporan
Part To Be Tested : Bearing #3 Type/Model : N/A
Barang Yang Diperiksa Type/Model
Inspection Method : Ultrasonic Testing Receive Date : 28 Maret 2018
Metoda Pemeriksaan Tanggal Terima
Quantity : 1 set Finish Date : 28 Maret 2018
Jumlah Tanggal Selesai
Program/Reference : Inspection Ref. Manual : MIL-STD 2183 Test Method
Program/Referense Dokumen Ref. Bond Testing Babbit Lined

DESCRIPTION OF TEST
Uraian Hasil Pemeriksaan

INSPECTED USING ULTRASONIC TESTING CTS-9005


Gain : 70,0Db
Step : 2,0
Spath : 150 & 250,0mm
Vel : 5920m/s
Dly : 0,0mm
Zero : 0,00 u s
Rej : 0%

Calibration Process :

Unbounded Bounded

CALIBRATION DUE DATE : AUGUST 30, 2018


RESULT : BOUNDED

Inspected by : Djoko Sumbarto/NDT Level 2


Diperiksa oleh

Note :
Catatan
1. Claim after 3 (three) month from date of issued will not be accepted.
Pengaduan atas hasil uji setelah tiga bulan dari tanggal laporan, tidak diterima.
2. This certificate may not be reproduced, without permission from the head of quality control
Tidak dibenarkan memperbanyak laporan hasil uji, tanpa seijin kepala quality control.
NDT TEST REPORT
Laporan Hasil Uji N
NDT
LAB. NON DESTRUCTIVE TESTING QUALITY CONTROL
PT. SIS MEL TRI AERO T

Customer Name & RO/WO : PT NTP Report Number : 005/SMT-AERO/IV/2018


Nama Customer & RO/WO WO : Nomor Laporan
Part To Be Tested : Bearing #4 Type/Model : N/A
Barang Yang Diperiksa Type/Model
Inspection Method : Ultrasonic Testing Receive Date : 28 Maret 2018
Metoda Pemeriksaan Tanggal Terima
Quantity : 1 set Finish Date : 28 Maret 2018
Jumlah Tanggal Selesai
Program/Reference : Inspection Ref. Manual : MIL-STD 2183 Test Method
Program/Referense Dokumen Ref. Bond Testing Babbit Lined

DESCRIPTION OF TEST
Uraian Hasil Pemeriksaan

INSPECTED USING ULTRASONIC TESTING CTS-9005


Gain : 70,0Db
Step : 2,0
Spath : 150 & 250,0mm
Vel : 5920m/s
Dly : 0,0mm
Zero : 0,00 u s
Rej : 0%

Calibration Process :

Unbounded Bounded

CALIBRATION DUE DATE : AUGUST 30, 2018


RESULT : BOUNDED

Inspected by : Djoko Sumbarto/NDT Level 2


Diperiksa oleh

Note :
Catatan
1. Claim after 3 (three) month from date of issued will not be accepted.
Pengaduan atas hasil uji setelah tiga bulan dari tanggal laporan, tidak diterima.
2. This certificate may not be reproduced, without permission from the head of quality control
Tidak dibenarkan memperbanyak laporan hasil uji, tanpa seijin kepala quality control.
NDT TEST REPORT
Laporan Hasil Uji N
NDT
LAB. NON DESTRUCTIVE TESTING QUALITY CONTROL
PT. SIS MEL TRI AERO T

Customer Name & RO/WO : PT NTP Report Number : 006/SMT-AERO/IV/2018


Nama Customer & RO/WO WO : Nomor Laporan
Part To Be Tested : Bearing #5 Type/Model : N/A
Barang Yang Diperiksa Type/Model
Inspection Method : Ultrasonic Testing Receive Date : 28 Maret 2018
Metoda Pemeriksaan Tanggal Terima
Quantity : 1 set Finish Date : 28 Maret 2018
Jumlah Tanggal Selesai
Program/Reference : Inspection Ref. Manual : MIL-STD 2183 Test Method
Program/Referense Dokumen Ref. Bond Testing Babbit Lined

DESCRIPTION OF TEST
Uraian Hasil Pemeriksaan

INSPECTED USING ULTRASONIC TESTING CTS-9005


Gain : 70,0Db
Step : 2,0
Spath : 150 & 250,0mm
Vel : 5920m/s
Dly : 0,0mm
Zero : 0,00 u s
Rej : 0%

Calibration Process :

Unbounded Bounded

CALIBRATION DUE DATE : AUGUST 30, 2018


RESULT : BOUNDED

Inspected by : Djoko Sumbarto/NDT Level 2


Diperiksa oleh

Note :
Catatan
1. Claim after 3 (three) month from date of issued will not be accepted.
Pengaduan atas hasil uji setelah tiga bulan dari tanggal laporan, tidak diterima.
2. This certificate may not be reproduced, without permission from the head of quality control
Tidak dibenarkan memperbanyak laporan hasil uji, tanpa seijin kepala quality control.
NDT TEST REPORT
Laporan Hasil Uji N
NDT
LAB. NON DESTRUCTIVE TESTING QUALITY CONTROL
PT. SIS MEL TRI AERO T

Customer Name & RO/WO : PT NTP Report Number : 007/SMT-AERO/IV/2018


Nama Customer & RO/WO WO : Nomor Laporan
Part To Be Tested : Bearing #6 Type/Model : N/A
Barang Yang Diperiksa Type/Model
Inspection Method : Ultrasonic Testing Receive Date : 28 Maret 2018
Metoda Pemeriksaan Tanggal Terima
Quantity : 1 set Finish Date : 28 Maret 2018
Jumlah Tanggal Selesai
Program/Reference : Inspection Ref. Manual : MIL-STD 2183 Test Method
Program/Referense Dokumen Ref. Bond Testing Babbit Lined

DESCRIPTION OF TEST
Uraian Hasil Pemeriksaan

INSPECTED USING ULTRASONIC TESTING CTS-9005


Gain : 70,0Db
Step : 2,0
Spath : 150 & 250,0mm
Vel : 5920m/s
Dly : 0,0mm
Zero : 0,00 u s
Rej : 0%

Calibration Process :

Unbounded Bounded

CALIBRATION DUE DATE : AUGUST 30, 2018


RESULT : BOUNDED

Inspected by : Djoko Sumbarto/NDT Level 2


Diperiksa oleh

Note :
Catatan
1. Claim after 3 (three) month from date of issued will not be accepted.
Pengaduan atas hasil uji setelah tiga bulan dari tanggal laporan, tidak diterima.
2. This certificate may not be reproduced, without permission from the head of quality control
Tidak dibenarkan memperbanyak laporan hasil uji, tanpa seijin kepala quality control.

You might also like