Dimensions:

Diameter: 10“/6“
Riser Height: 8500 mm
Primary Arm: 7500 mm
Secondary Arm: 8000 mm
Height of Riser Flange A-203A/B: Product Line: 742 mm
Vapour Return Line: 680 mm
Height of Riser Flange A-303A/B: Product Line: 702 mm
Vapour Return Line: 650 mm
Total Weight in Parking Position: 226000 N
Components:
Safety System: ERS 4
Operation: Hydraulical
Material: Low Temperature Steel/Steel
Swivel Joints: D1010, D0002, D2000
Seals: FVMQ
Lubricant: Shell Tellus S2 VX46
Connections:
Product Entry: Product Line: 12“ Flange; ANSI 150
lbs; RF Vapour Return Line: 8“
ANSI 150 lbs; RF
Product Exit: Product Line: Hydraulic QCDC 10”;
ANSI 150 lbs; RF Vapour Return
Line: man. Camlock Coupler 6“
ANSI 150 lbs; RF
Drain Connection: Riser: 3”; ANSI 150 lbs; RF
TSA: 1 ½” ANSI 150 lbs; RF
Pressure and Temperature:
Operation Pressure: A-203A: 8 bar (81577 Kg/m2)
A-203B: 0.12 bar (1224 Kg/m2)
A-303A: 8 bar (81577 Kg/m2)
A-303B: 0.12 bar (1224 Kg/m2)
Test Pressure: A-203A: 21 bar (214140 Kg/m2)
A-203B: 5.25 bar (53535 Kg/m2)
A-303A: 21 bar (214140 Kg/m2)
A-303B: 5.25 bar (53535 Kg/m2)
Allowable Working Pressure: A-203A: 14 bar (142760 Kg/m2)
A-203B: 3.5 bar (35690 Kg/m2)
A-303A: 8 bar (142760 Kg/m2)
A-303B: 3.5 bar (35690 Kg/m2)
Working Temperature: A-203A/B: -42°C to +42°C
A-303A/B: -42°C to +42°C
Allowable Working Temperature: A-203A/B: -45°C to +70°C
A-303A/B: -10°C to +70°C
Allowable Ambient Temperature: +24°C to +35°C
Wind
Parking Position: 40 m/s – 144 Km/h – 90 mph
Working Position: 22 m/s – 80 Km/h – 50 mph
Maintenance Position: 14 m/s – 50 Km/h – 30 mph
Wind Shear in Parking Position 27000 N
OTM – Dry: 320000 Nm
Product
Product: A-203A/B: C3 Propane
A-303A/B: C4 Butane
Flow Rate: A-203A/B: 722 m3
A-303A/B: 699 m3
Hydraulic System
Hydraulic Station: 9.6 Kw
Hydraulic Pump: 1460 rpm
Electric Motor: 400V/690V; 50 Hz
Electric System
Operation Voltage 3x 400V
Frequency: 50 Hz
Current: 24 V/DC
Remote Control
Type: GL-C-C-EX-IIB
System Number: 1210211
Frequency: 869.400 MHz