Work Instruction Doc. No.

WI-QC-02
Rev. No. 00
Determination of Flow Time of Effective Dt.
Resin

- Fit a B4 Ford cup (as per IS: 3944) on a stand.

- Take about 150ml of Resin for test.

- Check the temperature of resin. It should be 250C ± 10C.

- Increase or decrease resin temperature by heating and cooling to bring

it to required temperature.

- By closing the outlet of B4 Ford cup with finger fill the Resin into it.

- Scrap off excess Resin with the help of a glass rod to make it to the

level of cup.

- Allow Resin to flow through outlet by taking out finger.

- Start stop watch immediately as soon as flow starts.

- Stop the stop watch as soon as there is a break in the resin flow.

- Note the time taken. This time gives the Flow time of Resin.