You are on page 1of 5

Selector Switches

for Voltmeters & Ammeters

Description Connection capacity Complies with IEC 947-3 and


To provide command signals or • rigid conductor : 1.5 to 10 mm2 IEC 60 947-3.
program selection in electrical • lexible conductor : 1 to 6 mm2
control schemes.
Isolating voltage : 500V~
Application Nominal current : 10-20A
For domestic and commercial
installations.

Description Characteristics Width in z Pack Cat. ref.


17.5mm qty.

1 pole selector switch 20A 400V~ 3 1 SK600


0
1 3 1 2 non spring return

2 pole selector switch 20A 400V~ 3 1 SK601


0
1 3 5 7 1 2 non spring return

SK600 2 6

Voltmeter selector 20A 400V~ 3 1 SK602


3Ph&N
3 readings between phases
3 readings between phase & neutral
null position (no reading)

8 10
V
L1 L1 L2 0 L1
L2
L2 L3 L2
L3
N L3 L1 L3
3 5 7 1
SK602
Ammeter selector 20A 400V~ 3 1 SK603
4 positions
use in 3Ph&N
reading by phase
0 position (no reading)
should be used with current transformer (CT)
8 10
A
L1 0

L2
L3 L1
L3
1 7 5 3
L2

Step selector switch 20A 400V~ 3 1 SK604


2 3 4
5 3 7 1
1
SK603 2 0

Key selector switch 10A 400V~ 3 1 SK606


0
1 3

1 1

2 4
0

SK606

5.16
Analogue Voltmeters & Ammeters

Analogue voltmeters Frequency : 50/60Hz Indirect reading via current


For commercial and industrial transformers - see page 5.22
installations. Analogue ammeters from 50 to 600A
For commercial and industrial
• single phase : installations. Connection capacity
direct connection • rigid conductor 10 mm2
• three phase : Direct reading : • lexible conductor 6 mm2
use of a voltmeter selector up to 30A
switch SK602 - see page 5.16 Complies with IEC 60 054-1.

Description Characteristics Width in z Pack Cat. ref.


17.5mm qty.

Voltmeter accuracy : 1,5% (full scale) 4 1 SM500


consumption : 3VA
0 - 500V

SM500
Analog ammeters 0 - 5A 4 1 SM005
direct
0 - 15A 4 1 SM015

0 - 30A 4 1 SM030

Control & Signalling


Ammeters accuracy : 1,5% (full scale)
current transformer (CT)
operated
SM030
reading via CT SR051 scale : 0 - 50A 4 1 SM050

reading via CT SR101 scale : 0 - 100A 4 1 SM100

reading via CT SR150 scale : 0 - 150A 4 1 SM150

reading via CT SR250 scale : 0 - 250A 4 1 SM250

reading via CT SR400 scale : 0 - 400A 4 1 SM400

reading via CT SR600 scale : 0 - 600A 4 1 SM600

reading via CT SR800 scale : 0 - 800A 4 1 SM800

reading via CT SR850 scale : 0 - 1000A 4 1 SM850

reading via CT SR900 scale : 0 - 1500A 4 1 SM900

reading via CT SR910 scale : 0 - 2000A 4 1 SM910

5.17
Digital Voltmeters & Ammeters

Digital voltmeters SM501 Digital ammeters Connection capacity


For domestic and commercial • from SM020 to SM911: Rigid conductor 10 mm2
installations. SM020 : direct reading Flexible conductor 6 mm2
• from SM151 to SM911 :
• three phase : reading via a current Complies with IEC 60 054-1.
use of a voltmeter selector transformer (see below)
switch SK602

Description Characteristics Width in z Pack Cat. ref.


17.5mm qty.

Digital voltmeter voltage rating :


220/230V; 50/60Hz
accuracy : ±1%
consumption : 4VA
scale : 0 -500V 4 1 SM501

Digital ammeters voltage rating :


220/230V; 50/60Hz
accuracy : ±1%
consumption : 4VA
SM501
direct scale : 0-20A 4 1 SM020

reading via CT 150/5A scale : 0-150A 4 1 SM151


(SR150)

reading via CT 400/5A scale : 0-400A 4 1 SM401


(SR400)

reading via CT 600/5A scale : 0-600A 4 1 SM601


(SR600)

reading via CT 800/5A scale : 0-800A 4 1 SM801


(SR800)

SM020 reading via CT 1500/5A scale : 0-1500A 4 1 SM901


(SR900)

reading via CT 2000/5A scale : 0-2000A 4 1 SM911


(SR910)

Digital Multimeters
Multimeter instantaneous, average or Connection capacity
For monitoring the electrical maximum (voltage and intensity Rigid conductor 10 mm2
network : single, two or three per phase in RMS value). Flexible conductor 6 mm2
phases (with or without neutral).
Connection on current For monitoring of power Complies with IEC 60 054-1.
transformer (not provided). generator, it measures the
Enables to display 3 electrical frequency and working time.
values at the same time, in type

Description Characteristics Width in z Pack Cat. ref.


17,5 mm qty.

Multimeter • 3 voltmeters : 35 to 480 V 4 1 SM001


• 3 ammeters per
transformer 0-5 A : 5 to 6000 A
• mesure of frequency :
40 to 80 Hz
• hourly metering

SM001

5.18
Voltmeters & Ammeters
Analogue voltmeter and ammeter Ammeters range

Technical speciications ref. scale reading


Electrical characteristics SM005 0-5A direct
• direct reading voltmeter : 500V for 50/60Hz SM015 0-15A direct
• direct reading ammeter : 5, 15, 30A
• ammeter with CT : CT/5A SM030 0-30A direct
• consumption : voltmeter: 1.5VA/ammeter : 1,5VA SM050 0-50A via CT/5A
• isolating voltage : 2kV
SM100 0-100A via CT/5A
Environment SM150 0-150A via CT/5A
• working T°: -23°C ± 2°C class = 2
• working T°: -25°C to +50°C class > 2 SM250 0-250A via CT/5A
• storage T°: -40°C to +80°C SM400 0-400A via CT/5A
Connection capacity SM600 0-600A via CT/5A
• lexible : 1 to 6 mm2 SM800 0-800A via CT/5A
• rigid : 1.5 to 10 mm2
SM850 0-1000A via CT/5A
SM900 0-1500A via CT/5A
Voltmeters range
SM910 0-2000A via CT/5A
ref. scale reading
SM500 0-500V direct

Electrical connection Electrical connection


CT*

* current transformer

Control & Signalling


see below

voltmeter

ammeter

Digital voltmeter and ammeter

Technical speciications
Connection
Electrical characteristics • Connection capacity:
• Working voltage: 220/230V~ 50/60Hz lexible: 6 mm2
• Consumption: 4VA rigid: 10 mm2

Environment Overload withstand of ammeters


• Working T°: -5 to +40°C • 1,2 x In continuous
• Storage T°: -10°C to +55°C • 2 x In for 5 seconds
These values are to allow for starting currents

5.19
Voltmeters & Ammeters

ref. product range consumption accuracy reference accuracy max momentary frequency Hz isolating voltage
% temp. °C variation permanent overload
overload
SM501 voltmeter 500 V ≤ 4,5 VA ±1 23 ± 1°C ± 0,03% / °C 1,2 Un 2 Un/5 sec. 45 - 65 2 kV/50 Hz-1 min
SM020 direct 0 - 20 A ≤ 4,5 VA ±1 23 ± 1°C ± 0,03% / °C 1,2 In 10 In/5 sec. 45 - 65 2 kV/50 Hz-1 min
ammeter
SM151 ammeter 0 - 150 A ≤ 4,5 VA ±1 23 ± 1°C ± 0,03% / °C 1,2 In 10 In/5 sec. 45 - 65 2 kV/50 Hz-1 min
SM401 with CT 0 - 400 A
SM601 0 - 600A
SM801 0 - 800A
SM901 0 - 1500A
SM911 0 - 2000A
SM001 Multimeter 35 to 480VM < 0,5 VA 0,5% ±digit 1,2 In 5 In/1 sec. 40 - 80
5 o 8000 A ≤ 0,5 VA 0,5% ±digit
40 to 80 Hz ± 2 Hz

Electrical connection CT*


R
R
Y Y
B B
voltmeter

ammeters

connection: SM151/401/601 or : SM801/SM901/SM911


* CT rating of your choice

Operating principle
For SM501 For SM020 For SM151, SM401, SM601

circuit circuit circuit


under under under
measurement voltmeter measurement ammeter measurement ammeter

Operating principle for SM001 SM002


Door lush mounting kit for SM001

R R
Y Y
B B

current input

supply input
R Y B

400 VM
230 VM
0V

5.20