SA-530/SA-530M ASME BPVC.II.

A-2017

19.2 Welded Pipe — A section of welded pipe not less MPa] for pressures below 1000 psi [7 MPa], and to the
than 4 in. [100 mm] in length shall be flattened cold nearest 100 psi [1 MPa] for pressures 1000 psi [7 MPa]
between parallel plates in two steps. The weld shall be and above. The hydrostatic test may be performed prior
placed 90° from the direction of the applied force (at the to cutting to final length, or prior to upsetting, swaging,
point of maximum bending). During the first step, which expanding, bending, or other forming operations.
is a test for ductility, no cracks or breaks on the inside or
20.2 Regardless of pipe-wall stress-level determined
outside surfaces, except as provided for in 19.3.4, shall
by Eq. (3), the minimum hydrostatic test pressure required
occur until the distance between the plates is less than the
to satisfy these requirements need not exceed 2500 psi
value of H calculated by the Eq. (2). During the second
[17.0 MPa] for outside diameters (see D in 20.1) of 3.5 in.
step, which is a test for soundness, the flattening shall be
[88.9 mm] or less, nor 2800 psi [19.0 MPa] for outside
continued until the specimen breaks or the opposite walls
diameters over 3.5 in. [88.9 mm]. This does not prohibit
of the pipe meet.
testing at higher pressures at the manufacturer’s option or
19.3 Seamless, Centrifugally Cast, and Welded Pipe: as provided in 20.3.
19.3.1 Evidence of laminated or defective material
20.3 With concurrence of the manufacturer, a minimum
or weld that is revealed during the entire flattening test
hydrostatic test pressure in excess of the requirements of
shall be cause for rejection.
20.2 or 20.1, or both, may be stated on the order.
19.3.2 Surface imperfections not evident in the test
specimen before flattening, but revealed during the first 20.4 The test pressure shall be held for a minimum of
step of the flattening test, shall be judged in accordance 5 s without resultant leakage through the pipe wall. For
with the finish requirements. welded pipe, the test pressure shall be held for a time
sufficient to permit the inspector to examine the entire
19.3.3 Superficial ruptures resulting from surface
length of the welded seam.
imperfections shall not be a cause for rejection.
19.3.4 When low D-to-t ratio tubular products are 20.5 The hydrostatic test may not be capable of
tested, because the strain imposed due to geometry is unrea- inspecting the end portion of the pipe. The length of pipe
sonably high on the inside surface at the six and twelve that cannot be tested shall be determined by the manufac-
o’clock locations, cracks at these locations shall not be turer and, when specified in the purchase order, reported
cause for rejection if the D to t ratio is less than 10. to the purchaser.

20. Hydrostatic Test Requirements 21. Certified Test Report


20.1 Except as provided in 20.2 and 20.3, each length 21.1 When specified in the purchase order or contract
of pipe shall be tested by the manufacturer to a hydrostatic the producer or supplier shall furnish a Certified Test
pressure which will produce in the pipe wall a stress not Report certifying that the material was manufactured, sam-
less that 60% of the minimum specified yield strength for pled, tested, and inspected in accordance with the Specifi-
carbon and ferritic alloy steel pipe, or 50% of the specified cation, including year date, the Supplementary
minimum yield strength for austenitic alloy steel pipe. The Requirements, and any other requirements designated in
test pressure or stress shall be determined by the following the purchase order or contract, and that the results met
equation: the requirements of that Specification, the Supplementary
P p 2St /D or S p PD /2t (3) Requirements, and the other requirements. A signature or
notarization is not required on the Certified Test Report,
where: but the document shall be dated and shall clearly identify
P p hydrostatic test pressure in psi or MPa, the organization submitting the Report.
S p pipe wall stress in psi or MPa,
NOTE 3 — Notwithstanding the absence of a signature or notarization,
t p specified nominal wall thickness, nominal wall
the organization submitting the Report is responsible for the contents of
thickness corresponding to specified ANSI sched- the Report.
ule number, or 1.143 times the specified minimum
wall thickness, in. [mm], and 21.2 In addition, the Certified Test Report shall include
D p specified outside diameter, outside diameter cor- the following information and test results, when applicable:
responding to specified ANSI pipe size, or outside 21.2.1 Heat Number,
diameter calculated by adding 2t (as defined
21.2.2 Heat Analysis,
above) to the specified inside diameter, in. [mm].
20.1.1 The hydrostatic test pressure determined by 21.2.3 Product Analysis, if specfied or required,
the equation shall be rounded to the nearest 50 psi [0.5 21.2.4 Tensile Properties,

910