CHECKER'S CHECK LIST

List of Check point Yes No Remarks


1. Is all the information in the title block correct?
2. Are the details presented in an "easy to read" manner?
2.1 All necessary sections/views present and projected properly.
2.1 All necessary sections/views present and projected properly.
2.2 Any ambiguous dimensions.
2.3 Are details in accordance with standards, job specs, and fabricator policy?
3. Did I check ALL the dimensions?
4. Did I check the member sizes?
4.1 If size is substituted did I consider impact on adjoining members?
5. Did I check the Connections?
5.1 For fit.
5.2 For engineers compliance
5.3 For code compliance
5.4 For erection clearance.
6. Did I read the specs?
6.1 Is the grade of the material noted correctly for all material?
6.2 site weld testing required?
6.3 Are there special cleaning and painting requirements?
6.4 Is shop inspection required: NDT, Radiograph, MagParticle etc?
6.5 Are weld procedures required?
6.6 Load indicator washers required?
6.7 Is shop assembly required?
7. Is each shipping piece shippable? over length, over width, overweight.
8. Are all the quantities correct?
9. Does the bill of material match the dimensions on the drawing?
10. Are the erection drawings easy to read?
10.1 Do the columns have the correct direction orientation?
10.2 Is there a "North Arrow" on the plan?
10.3 Are all necessary dimensions shown correct on the plan / elevation
views?
10.4 Are all member sizes shown correct for each member?
10.5 Is all field welding that is required shown correctly?
10.6 Are elevations at top of floors, roofs, landings etc. shown correct?
11. Are the bolts sizes, grades, and quantities correct?
11.1 Are oversize washers required for the holding down bolts?
11.2 Is there and special bolt requirements?
12. Did I thoroughly study all the design drawing to see if all the members in
the in the scope of the fabricators contract have been detailed?
12.1 Reinforcement plates.
13 Are any pieces detailed beyond the capabilites of the fabricator's
equipment?
13.1 Are bend lengths and thickness within machine capacity?
13.2 Shop splices shown where required due to machine/material limitations?
13.3 Are punch sizes available for the slotted and round holes shown?
14. Did I put a lot of my unwanted opinion into marking up the detail (did I
mark it up the way I would have detailed it) or did I check to see only if it
was right or wrong (if it works let it go)?
15. Establish marks for typical parts such as base plates, cap plates, stiff
plates, shear plates , connection angles.
16. Layout and confirm connections shown on design work... special
concentration to brace bays, rafters or trusses or girders and parts connecting
to them. (any component that is not straight or level
17. Layout and confirm connections for secondary items like girts, door
frames and so on.
18. Layout and confirm connections for miscellaneous items stairs, handrail,
ladders and so on.
19. What is the surface finishing?
20. Confirm no paint areas for field welding and slip critical connections
21 If galvanizing is involved confirm max sizes for shipping. Is there
adequate drainage holes
PREPARED BY: CHECKED BY APPROVED BY