You are on page 1of 12

XJ ELEVATOR CO., LTD.

Economic & Technical Developing Area,


Xuchang, Henan, China 461000
Tel: (86) 374 831 6649 Fax: (86) 374 831 8800
URL: www.xjelevator.com

XJ ELEVATOR PRIVATE LIMITED


57 Ubi Avenue 1, Ubi Centre, #08-16
Singapore 408936
Tel: (65) 6744 6700 Fax: (65) 6744 6400
Email: sales@xjelevator.com.sg

Local Representative
SCAAI V1

Pictures in this brochure are computer generated; real product may differ.
Specification and designs are subject to change without prior notice.
Vertical Dreams

XJ SIEMENS
Vertispace Cargo Elevator
English

Deutsch
中文
Français
Heavy-load vertical transportation solution

To meet the current industrial transportation needs, Vertispace provides a sophisticated cargo vertical
transportation solution, providing complete upgrading in system performance and effciency.
Superior system

Traction machine
Vertispace adopts big capacity PM synchronous gearless machine, which brings many "green" advantages in
energy saving, easy maintenance and overall performance.

Inverter
Different with traditional AC or VVVF inverter, Vertispace is driven by the vector controlled inverter, which greatly
increases system efficiency.

Main board
The main board is powered by XJ's super dual-core CPU structure and 64MB memory, the calculation capability
is 32MIPS.

Car cage framework


Cage structure is more robust and stable to accomodate the overloading or unbalancing load conditions, greatly
reduces mechanical worm-out or damage rate, prolonging the lifespan of the lift.
Heavy-load friendly features
Outstanding overloading capability Cage protection measures
Vertispace PM traction machine is able to output 290% Rubber plate, bumper or folklift stop-blocker can
rated power in overloading circumstances. be equiped to avoid scratches or damages.

Spacious cage and entrance design Other advantages


Car cage size and door entrance opening are designed Durable anti-slippery chequer plate
for maximum space, making Vertispace suitable for Strong ventilation
cargo handing. Direct fluroscent light with better illumination

Vibration absorbing structure Door open prolong button


The system can ease operational vibration, and improve Heavy-duty mild steel sill
the running performance in ultra-heavy-load condition. and more ...

Mild steel chequer plate Fluorescent light Heavy-duty mild steel sill

Door open prolong button

Rubber bumper (optional) Car panel rubber protection (optional) Folk-lift stop blocker (optional)
Vertispace hydralic elevator
Vertispace hydralic elevator adopts high-grade hydralic driving system, provides a more reliable and durable
system. The new hydralic solution uses better oil seal technolgy and equipments to avoid oil leakage
problems.
Vertispace hydralic elevator can be widely applied in ports, airports, industrial buildings where the space is
not enough for a convientional installation.
Model: THX01

Ceiling Powder coating COP


Car walls Powder coating Plate S/S hairline
Flooring Mild steel chequer plate Indicator Dot matrix LED display
Car door Powder coating Button Micro-movement push button

Available Coating Color

Pistachio Green 02 White Solid 03 Beige 06 Aqua Blue 05


Model: THX02

Ceiling S/S hairline COP


Car walls S/S hairline Plate S/S hairline
Flooring Mild steel chequer plate Indicator Dot matrix LED display
Car door S/S hairline Button Micro-movement push button

Entrance

HTZ25 2PCO HTZ14 3PSO HTZ15 4PCO HTZ04 6PCO


Powder coating door Powder coating door Powder coating door Powder coating door
2000-3000KG Vertispace Cargo Elevator Standard Layout Drawings

HoistingHook,3000kg, By others
Hoistway Widht(AH)

2500
500
GuidRail ≤5000 50

Cage Outside Depth ( BS)


Hoistway Depth (BH)
300 2500

Overhead Height (OH)


~

Door Opening (JJ)


Rail bracket Spacing 1500mm

Structure Opening (SO)


Cage Outside Size (AS)
Total Rail Height

Hoistway Plan
Rail 5000 X n=

Ventilation Aperture
(by others)
Storey Height≥2700

Hook vertical Projection

R1 R2
5000

Pit Depth(PP)

A
A

Control Panel
Rail Bracket Span

Powe Supply Pannel (by others)


1000

Light Outlet (by others)


Rail Span

R3 R4

Elevation Plan Motor Room Plan

MR Pit Overhead
Speed Load Door Opening Cage Size Hoistway Szie MR Size
Model Height Depth Height
(m/s) (Kg) JJ×HH AS×BS AH×BH AM×BM
(HM) (PP) (OH)

9000-HT-20-05-F 0.5 2500 1600 4600


2000 1500×2200 2000×2300 2900×2800 2900×2800
9000-HT-20-10-F 1.0 2500 1600 4700
9000-HT-30-05-F 0.5 3000 1600×2200 2500×2500 3500×2900 3500×2900 2500 1600 4600
9000-HT-30-05-F 0.5 3000 1600×2200 2000×3000 3000×3300 3000×3300 2500 1600 4600
8000-HT-50-05-F 0.5 5000 2000×2200 2700×3620 3900×4100 3900×4100 2500 1600 4600
8000-HT-65-02-F 0.25 6500 2400×2200 3360×3620 4700×4100 4700×4100 2500 1600 4600
Vertispace Through-type Standard Layout Drawing

Hoisting HooK, ≥5000kg,By others

Motor Room Height 2500


Hoistway Width (AH)
Structure Opening (SO)

Door Opening(JJ)

400
Overhead Height (OH)

400

Cage Outside Depth (BS)


Hoistway Depth (BH)
Rail Bracket Spacing 1500mm
Total Hoistway Height

Cage Size (AA)

Structure Opening (SO)


1600

400

Hoistway Plan

Elevation Plan

Hoistway Overhead
Speed Load Door Width Cage Size MR Size
Model Szie MR Pit Height
(m/s) (kg) JJ×HH AS×BS AM×BM
AH×BH (OH)
8000-QT-30-05 0.5 3000 2400×2200 2600×6000 4000×6300 4000×6300 2500 1600 4600
9000-QT-30-05 0.5 3000 2400×2200 2600×6000 4000×6300 4000×6300 2500 1600 4600
Functions
●- Standard function; ○ - Optional function; ◎# –Standard function but rely on an optional function numbered with #.

ID Function Description Spec


Fully automatic operation used for a two elevator system. Calls are responded to by
1 Duplex Control whichever car that can serve the call faster. When there is no call, one of the cars will ○
standby at the starting floor while the other car stops at the pre-designated floor.
A group control system is used when there are more than two elevators operating in
a group (up to 16 elevators). Using XJ group control dispatching algorithm, system
2 Group Control ○
reduces waiting time by computing forecasts of waiting time and distributing them
evenly among all cars controlled.
When the elevator is not in use for pre-designated period, the light and ventilation fan
3 Auto turn-off car light & fan ●
in the car are automatically turned off to conserve energy.
4 Car emergency lighting An emergency light will be activated automatically when power failure occurs. ●
5 Maintenance Operation Elevator operates at lower speed during maintenance ●
This system will activate an audio/visual signal and prevent the elevator from moving
6 Overload protection ●
when it is overload.
An interphone system among car, machine room, car top, pit and guard house is
7 Communication system ●
provided for emergency communication.
In the unlikely event of temporary trouble during operation, the elevator automatically
8 Nearest landing operation goes to the nearest floor at low speed to prevent passengers from being trapped ●
inside.
Fault recovery due to power Once power supply recovered, elevator moves to the nearest floor and restore the
9 ●
failure normal operation.
When the elevator stops out of the door open zone, it will move to the nearest floor at
10 Rescue operation ●
slow speed to release passengers.
After activation, the stop floor is selected by an elevator operator, during attendant
11 Attendant operation ●
operation, hall call can be responded.
After activation, the elevator can only respond to car call selection but ignor hall call
12 Independent operation ●
commands..
In the event of emergency, passengers can be rescued and escaped through the hatch
13 Car roof escape hatch ○
which can only open outside.
For security reason, main board does not come with display screen and operation
14 Operating handset ○
keypad, which are integrated into a operating handset and provided separately
System supports rich of signals, letters and numbers for various floor number
15 Floor no. display char-set ●
indication
16 Micro-leveling operation Automatic correct of elevator landing level when subjected to varying car load ●
17 Standby floor setting A floor can be specified as standby floor, which used in automatic returning function ●
Automatic Returning After all the calls have been served, the elevator returns to the pre-designated standby
18 ●
Function floor.
Door holding time Door open holding time can be manually adjusted to prolong or shorten door open
19 ●
adjustment time
When door fail to open at certain landing, elevator moves to the next landing to release
20 Door open at next landing ●
passengers.
Main board can store faulty records for last 20 break-downs with error codes and
21 Faulty record ●
trouble-shooting information.
When a hall call button signal keeps ON for more than 20 seconds, the elevator
22 Hall call self-diagnose determines this button is faulty and isolated it from system and twinkle the button ●
lamination till the button signal is OFF.
Includes overvoltage protection, overheat protection, short circuit protection, earth
23 Door operator protection protection, overload protection, PTC protection, overspeed protection, door inter-lock ●
protection, a2t temperature protection, etc.
When the door cannot be fully closed within pre-designated period, elevator tries to
24 Door Close Protection close the door again. If fail to close for more than 6 times, activate the alarm signal ●
and set to faulty mode
Door status scanning If landing error occurs, system can automatically scan all the landing door status and
25 ○
function locate the fault immediately.
Traction machine When the traction machine's operation temperature is higher than designated value,
26 ○
overheating protection system alarms and stops operation.
Electrical overspeed By analyzing encoder's feed-back, controller determines whether the motor runs under
27 ●
protection overspeed and take the necessary protection measures to make safe
When the fireman switch is turned on, the elevator returns to the designated floor and
28 Fireman Operation ○
ready for fireman use.
In the event of fire, the elevator is automatically brought to the designated floor where
29 Fire emergency operation ◎28
it remains inoperative for passenger safety.
Special designed landing door is able to isolate the flame into hoistway or car for one
30 Fire Rated Landing Doors ○
or two hours
ID Function Description Spec
If the door is not close after one minute due to door safety signal or other reasons,
31 Door Nudging ○
elevator force to close the door in very slow speed
When this button on the car operating panel is pressed, the elevator doors stay open
32 Door open prolong button ●
for a pre-set period of time.
This function allows passenger to cancel the car call that is registered wrongly, by
33 Car call cancellation ○
pressing the same button again. It thus eliminates unnecessary stops.
34 Overload bypass When car is fully loaded, it will only responds to car calls and bypass all hall calls ○
Mechanical safety unit can be provided an installed to both sides of the car doors.
35 Door safety edge If a passenger makes contact with the safety edge of the closing doors, the doors ○
immediately re-open.
The multi-beam sensors installed at the edge of the door will kept h doors open when
36 Multi-beam door sensor ●
the sensor path is obstructed.
With car door lock, the riding passengers cannot force to open the car door if car is not
37 Car door lock ○
in landing area, prevent passenger from dropping into hoistway or any other injuries.
38 Arrival Gong An electronic chime located on car top sounds just before the arrival of the elevator. ●
Present standard message information is announced to passengers through a voice
39 Voice Synthesizer ○
synthesizer. (Available in multiple languages)

40 Hall lantern Hall lanterns can be provided instead of hall indicators. (for group control, hall lanterns
will be provided as basic feature) ◎2

Vacuum fluorescent display (VFD) indicator to show the elevator status with maximally
41 VFD indicator ○
visual satisfaction.
Indicator with face plate is separately and horizontally placed at the top of entrance or
42 Horizontal Indicator ○
transom instead of incorporated into hall call or COP.
Additional floor selection and door open/close buttons are located on the car left hand
43 Sub COP ○
panel or left entrance panel.
44 Through type entrance There are two doors inside the car, make the landing at different direction. ○
When elevator moving by, it stops at the compulsory-stop-floor and open door even
45 Compulsory stop floor ○
without call registered for this floor.
Specific ser vice floors can be locked out as non-stop floor through system
46 Floor lock out operation ○
configuration.
Convert the 3 phase power supply to the system acceptable range (AC380V-415V/
47 Power supply converter ○
50Hz),
Steadize the power supply voltage fluctuation if the local voltage fluctuation greater
48 Automatic voltage regulator ○
than required value.
A floor can be accessed within pre-set time period; if other than the period, the floor
49 Scheduled non-serving floor ○
cannot be selected from car neither made any hall call.
50 Parking Operation The elevator can be parked at the designated floor with a key switch ○
There are two parking switches at different floor, each switch can be used to excise
51 Dual parking switches ○
parking operation
Scheduled startup /
52 Elevator automatically starts up and shuts down on the preset scheduled time. ○
shutdown service
For group control system, two standby position schemes can be set. Once activated,
53 Standby position scheme ◎2
elevators will be dispatched to the landing specified in the standby scheme.
Emergency operation for In the event of building power failure, the elevator can be operated by building standby
54 ○
power failure by generator generator to move it to the designated floor.
Automatic rescue device for In the event of power failure, the system automatically changes over to battery power
55 ○
power failure to bring the elevator to the nearest floor.
Earthquake emergency
56 When an earthquake is detected, the elevator will stop at the nearest floor. ○
operation
Car rear and side walls are covered with 1m high rubber protection plate to avoid
57 Rubber protection plate ○
cargo scratch or damage
58 Forklift stop blocker Stop blockers are mounted on the car flooring to position the folklift safely ○
59 CWT safety protection The elevator equips with CWT overspeed protection components ○
For monitoring of movement inside the car by the security personnel. (camera,
60 Closed-circuit TV ○
recorder cabling by others)
Various supervisory operations, communication, and status monitoring can be
61 Supervisory Panel ○
provided through either the conventional LED. (Cabling done by others)
Computer is used to monitor various supervisory operations, communication, and
62 PC Monitoring System status information with comprehensive and handy operations. (Computer supplied by ○
others; cabling done by others)

You might also like