siemens.com / gasturbinesII
Gas turbines from
4 to 400 MW
The Siemens gas turbine range has been designed and
tailored to help meet our customers‘ challenges in a
dynamic market environment.
Our models range from 4 to 400 MW, fulfilling the
requirements of a wide spectrum of applications in terms
of efficiency, reliability, flexibility, and environmental
compatibility.
The products offer low lifecycle costs and an excellent
return on investment.
SGT5-8000H 400 MW
50 Hz
gas turbines
SGT5-4000F 307 MW
Heavy-duty
SGT5-2000E 187 MW
SGT6-8000H 296 MW
60 Hz SGT6-5000F 242 MW
SGT6-2000E 116 MW
Ind. Trent 60 53 to 66 / 54 to 62 MW
60 Hz SGT-500 19 / 19 MW
gas turbines
SGT-400 13 to 14 / 13 to 15 MW
SGT-300 8 / 8 MW
SGT-200 7 / 8 MW
SGT-100 5 / 6 MW
Ind. 501 4 to 6 MW
Siemens gas turbines overview
[Power generation in MW(e) / Mechanical drive in MW]
SGT-500
SGT-600
Industrial 501 [4 to 6 MW] Industrial RB211
Heavy-duty SGT-100 [5/6 MW] SGT-700
gas turbines
50 Hz and 60 Hz
Aeroderivative
gas turbines
0–15 MW 16–99 MW
SGT6-2000E [116 MW]
100–400 MW
this document are gross values at ISO ambient conditions.
All combined cycle performance data in this document are
net values at ISO ambient conditions, assuming 50 mbar
condenser pressure.
Table of
contents
Siemens gas turbines are suitable for a wide range
of applications:
Power generation application for utilities, independent
power producers, oil and gas, and industrial users,
such as chemicals, pulp and paper, food and beverage,
sugar, automotive, metalworking, mining, cement,
wood processing, and textiles.
Mechanical drive applications for oil and gas, and
chemical industry.
References...................................................................................56
SGT5-8000H...................................................................................8
SGT6-8000H.................................................................................10
SGT5-4000F..................................................................................14
SGT6-5000F.................................................................................18
SGT5-2000E.................................................................................22
SGT6-2000E.................................................................................24
SGT5-8000H
Heavy-duty gas turbine
The SGT5-8000H offers outstanding performance and high The turbine is the core component of highly efficient
flexibility. With a gross power output of 400 MW, it is the gas-fired power plants, designed for 600 MW in combined
world’s most powerful gas turbine in commercial operation cycle operation, and combined cycle efficiencies of more
today. than 60%.
With more than 180,000 fired hours, the SGT-8000H series
provides mature technology with verified reliability and
availability.
References
Düsseldorf Lausward,
Germany
Turnkey combined cycle power plant
Power output: 595 MW(e) and up
to 300 MW(th)
Customer: Stadtwerke Düsseldorf AG
Scope: SCC5-8000H 1S with
1 x SGT5-8000H gas turbine
package
8
Power output: 400 MW
Outstanding performance
High flexibility, short start-up times
Proven in commercial operations
The SGT5-8000H achieves a world-class efficiency of more than 60% in combined cycle operations High operational flexibility due to world
class fast cold start and hot restart capability
NOx emissions < 25 ppmvd at 15% O2 on fuel gas Length 12.6 m (41 ft)
(without water injection for NOX control),
Width 5.5 m (18 ft)
< 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control) Height 5.5 m (18 ft)
9
SGT6-8000H
Heavy-duty gas turbine
The SGT6-8000H offers outstanding performance and high cycle operation with combined cycle efficiencies of more
flexibility. The air-cooled turbine with a gross power output than 60%.
of 296 MW is designed for simple and fast combined cycle
integration and short start-up times. With more than 180,000 fired hours, the SGT-8000H series
provides mature technology with verified reliability and
The turbine is the core component of highly efficient availability.
gas-fired power plants, designed for 440 MW in combined
References
10
Power output: 296 MW
Outstanding performance
High flexibility, short start-up times
Proven in commercial operations
The blade design provides high efficiency and Valves allow for controlled cooling air supply, The SGT6-8000H can be easily integrated in
is designed to ensure high reliability with low to cover the needs of different o
perating single-shaft or multi-shaft combined cycle
outage risk conditions plants
Turbine speed 3,600 rpm Net heat rate < 6,000 kJ/kWh < 6,000 kJ/kWh < 6,000 kJ/kWh
(< 5,687 Btu/kWh) (< 5,687 Btu/kWh) (< 5,687 Btu/kWh)
Pressure ratio 19.5 : 1
Number of 1 2 3
Exhaust mass flow 640 kg/s (1,410 lb/s) gas turbines
Exhaust temperature 630 °C (1,166 °F) Pressure/ Triple/Yes Triple/Yes Triple/Yes
reheat
NOx emissions < 25 ppmvd at 15% O2 on fuel gas
(without water injection for NOX control),
< 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control)
Physical dimensions
11
Turbine
Compressor
2
Four stages of fast acting variable-
pitch guide vanes (VGV) allowing
for improved part load efficiency 3 5
and high load transients
Evolutionary 3D blading
Rotating blades replaceable without
rotor destack or lift
Combustion
The proven SGT5-4000F gas turbine has a robust design Today, around 340 turbines have been sold. The installed
with internal cooling air passages for trusted long-term fleet has accumulated an impressive fleet experience of
operation and fast start-up capability. The advanced annular 11.5 million equivalent operating hours, and a fleet
combustion chamber with individually replaceable heat reliability of 99.2%.
shields allows for easy and fast walk-in maintenance.
Hydraulic Clearance Optimization (HCO) reduces clearance
losses to increase the gas turbine efficiency and minimize
degradation at start-up and shut down.
References
Kirishi, Russia
Supply of gas turbine packages
Power output: 800 MW
Customer: OGK-2 JSC, a subsidiary of
Gazprom Energo Holding OOO/LLC
Scope: Repowering project with
2 × SGT5-4000F gas turbine packages
14
Power output: 307 MW
The SGT5-4000F is a well-proven 50 Hz gas turbine Easy plant integration: Proven package For combined cycle applications, the
with an outstanding reliability and availability concepts for early power generation in simple SGT5-4000F is offered in single-shaft or
cycle operation; fast project execution multi-shaft (2 ×1) arrangements
Gross efficiency 40.0% Net heat rate 6,133 kJ/kWh 6,133 kJ/kWh
(5,812 Btu/kWh) (5,812 Btu/kWh)
Heat rate 9,001 kJ/kWh (8,532 Btu/kWh)
Number of gas 1 2
Turbine speed 3,000 rpm turbines
Pressure ratio 18.8 : 1 Pressure/reheat Triple/Yes Triple/Yes
Exhaust mass flow 723 kg/s (1,595 lb/s)
15
Combustion System
HCO
2 3
Improved performance
and minimized d egradation by
active control of clearances at
start-up and shut down
Turbine
The SGT6-5000F gas turbine offers economical power Today, around 370 turbines have been sold. The installed
generation with fast start-up for peak, intermediate, or fleet has accumulated more than 11 million equivalent
base load duty. It achieves peak values for reliability and operating hours, with a fleet reliability of 99.2%.
continuous operation with highest performance values
in its class.
References
18
Power output: 242 MW
The SGT6-5000F offers world class reliability and best in class emission values The SGT6-5000F is the first choice for reliable simple
or combined cycle operation in the 60 Hz market
19
Turbine
Combustion
Rotor
The SGT5-2000E gas turbine is a proven, robust engine for high viscosity. It provides low NOx emissions, even in the
the 50 Hz market which is used in simple cycle or combined part load range.
cycle processes with or without combined heat and power.
It is suitable for all load ranges, including peak load. Today, around 480 turbines have been sold (approx. 220
under license). Our installed fleet has accumulated more
The SGT5-2000E offers outstanding fuel flexibility. It can be than 17 million equivalent operating hours. The SGT-2000E
fired with low calorific gases or gases containing CO2, H2S series fleet´s overall best-in-class r eliability exceeds 99%.
and N2, as well as with crude oil and other liquid fuels with
References
Braemar 2, Australia
Power block for open cycle power
plant
Power output: 450 MW
Customer: ERM Power
Scope: 3 × SGT5-2000E gas turbine
packages
Geregu 2, Nigeria
Turnkey open cycle power plant
Power output: 434 MW
Customer: Niger Delta Power
Holding Company
Scope: 3 × SGT5-2000E gas turbine
packages
Az-Zour, Kuwait
22
Power output: 187 MW
Best-in-class reliability
High operational and fuel flexibility
Easy maintenance
Best-in-class reliable technology; robust and flexible performance Service-friendly design and customer-focused maintenance intervals
help to keep life cycle costs down
NOX emissions < 25 ppmvd at 15% O2 on fuel gas Length 10.3 m (34 ft)
(without water injection for NOx control),
Width 4.0 m (13 ft)
< 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOx control) Height 4.0 m (13 ft)
23
SGT6-2000E
Heavy-duty gas turbine
The SGT6-2000E gas turbine is a proven, robust engine for fuels with high viscosity. It provides low NOx emissions,
the 60 Hz market which is used in simple cycle or combined even in the part load range.
cycle processes with or without combined heat and power
supply. It is suitable for all load ranges, including peak load. Today, around 110 turbines have been sold, resulting in
The SGT6-2000E offers outstanding fuel flexibility. a fleet experience of nearly 7 million equivalent operating
hours. The SGT-2000E series fleet´s overall best-in-class
It can be fired with low calorific gases or gases containing reliability constantly exceeds 99%.
CO2, H2S and N2, as well as with crude oil and other liquid
References
Hsinta, Taiwan
Combined cycle power plant
Power output: 2,200 MW
Customer: Taiwan Power Company
Scope: 5 × SCC6-2000E 3 × 1 with
15 × SGT6-2000E gas turbine
packages
24
Power output: 116 MW
Best-in-class reliability
High operational and fuel flexibility
Easy maintenance
Two accessible silo combustion chambers for easy Variable inlet guide vanes (IGV); all Excellent start-up and part load behavior,
maintenance; ceramic tiles can be replaced individually rotating blades replaceable without rotor at 30 MW/ min ramp rate
de-stack or lift
NOx emissions < 25 ppmvd at 15% O2 on fuel gas Length 9.1 m (30 ft)
(without water injection for NOx control),
Width 3.3 m (11 ft)
< 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOx control) Height 3.3 m (11 ft )
25
Compressor
Combustion
1
Full fuel flexibility, ranging from heavy
fuel oil to low calorific gases
Axial Exhaust
Two easily accessible silo combustion
chambers for fast maintenance Cold end generator drive for
Lining with ceramic tiles which can be optimal flow pattern
replaced individually 4
5
Rotor and Bearings
2 3
Transient protection of clearances for
reduced degradation with Hydraulic
Clearance Optimization (HCO) active
clearance control
Light-weight, highly rigid design with
excellent start-up performance
Turbine
SGT-800...........................................................................................30
SGT-750...........................................................................................32
SGT-700...........................................................................................34
SGT-600...........................................................................................36
SGT-500...........................................................................................38
SGT-400...........................................................................................40
SGT-300...........................................................................................42
SGT-200...........................................................................................44
SGT-100...........................................................................................46
SGT-800
Industrial gas turbine
The SGT-800 industrial gas turbine offers broad flexibility The SGT-800 combines a simple, robust design, for high
in fuels, operating conditions, maintenance concepts, reliability and easy maintenance, with high efficiency
package solutions, and ratings. and low emissions. With a proven, long-term record of
The excellent efficiency and steam-raising capability successful installations around the world, the SGT-800 is
make it outstanding in cogeneration and combined cycle an excellent choice for power generation for industrial
installations. The SGT-800-based power plant, designed and oil and gas applications.
for flexible operation, is perfectly suited as grid support.
References
30
Power generation:
47.5/50.5/53.0 MW(e)
Proven reliability
Flexible solution
Excellent performance
SGT-800 core engine is available in three ratings with Classic package – easily transported and Single lift package – short installation and com-
standard options for hot and cold climates installed at site, easy on-site maintenance missioning time at site; U.S. adapted version
Physical dimensions
Simple cycle power generation
Classic package Single lift package
47.5 MW version 50.5 MW version 53.0 MW version
Approx. 290,000 kg 320,000 kg
Power output 47.5 MW(e) 50.5 MW(e) 53.0 MW(e) weight (617,300 lb) (705,500 lb)
Frequency 50/60 Hz 50/60 Hz 50/60 Hz Length 27.9 m (91 ft) 19.6 m (64 ft)
Gross efficiency 37.7% 38.3% 39.0% Width 7.3 m (24 ft) 4.7 m (15 ft)
Heat rate 9,547 kJ/kWh 9,389 kJ/kWh 9,231 kJ/kWh Height 15.1 m (49 ft) 15.3 m (50 ft)
Net plant heat rate 6,693 kJ/kWh 6,530 kJ/kWh 6,475 kJ/kWh
31
SGT-750
Industrial gas turbine
With maximized uptime, top-class performance, and a low It combines a robust, reliable design with high efficiency
environmental footprint offering the customer high lifetime and low emissions.
profitability, the SGT-750 industrial gas turbine is a perfect
choice for the oil and gas industry as well as industrial The SGT-750 has a track record of proven and verified
power generation. results after years in operation and several references in
both power generation and mechanical drive applications
The modular and flexible engine enables onshore or offshore such as pipeline and liquefied natural gas (LNG).
applications, mechanical drive or heat and power.
References
32
Power generation: 38.1 MW(e)
Mechanical drive: 39.3 MW
Maximized uptime
High efficiency
Low emissions
SGT-750 core engine with a free high-speed power Power generation package – O&G mechanical drive package for on- or
turbine also available as single lift offshore applications – also as single lift
Frequency 50/60 Hz
NOx emissions < 15 ppmvd at 15% O2 on fuel gas (with DLE) <15 ppmvd at 15% O2 on fuel gas (with DLE)
Siemens combined SCC-750 1 × 1 SCC-750 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx. 175,000 kg (385,809 lb) 76,000 kg (167,551 lb)
Net power output 49.4 MW(e) 99.4 MW(e) weight
Net plant efficiency 52.1% 52.7% Length 20.3 m (66.6 ft) 12.3 m (40.35 ft)
Net heat rate 6,946 kJ/kWh 6,898 kJ/kWh Width 4.8 m (15.75 ft) 4.3 m (14.11 ft) Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Number of gas turbines 1 2 Height 4.1 m (13.45 ft) 4.1 m (13.45 ft) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.
33
SGT-700
Industrial gas turbine
Thanks to its wide fuel range capability and design features, The SGT-700 gas turbine is an evolution of the proven
the SGT-700 is a perfect choice for several onshore applications: SGT-600 and is specifically designed for higher power
Industrial power generation, oil and gas power generation, output. It offers easy on-site or off-site maintenance and
and mechanical drive applications. operates with a wide range of gaseous and liquid fuels
It performs well in combined cycle plants and combined heat on Dry Low Emission (DLE).
and power plants. More than 70 units have been sold with 1.2 million
equivalent operating hours, and 78,000 equivalent
operating hours for the fleet-leading gas turbine.
References
Pinghu/Satellite Energy
450 KTA, China
Onshore simple cycle propane
dehydrogenation (PDH) plant
Customer: Zhejiang Satellite Energy
Co., Ltd
Scope: 1 x SGT-700 gas turbine coupled
with 1 x 25 MW compressor
34
Power generation: 32.8 MW(e)
Mechanical drive: 33.7 MW
Robust, reliable design
High fuel flexibility
Low emissions
Maintainable, reliable, and robust twin-shaft design for mechanical drive and For both power generation and mechanical drive package,
power generation the driver is the same
Fuel Natural gas, liquid fuel, dual fuel Natural gas, liquid fuel, dual fuel
Frequency 50/60 Hz
NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)
Siemens combined SCC-700 1 × 1 SCC-700 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx.
Net power output 45.2 MW 91.6 MW weight 169,000 kg (372,581 lb) 63,000 kg (138,891 lb)
Net plant efficiency 52.3% 53.1% Length 18.8 m (61.68 ft) 11.7 m (38.38 ft)
Net heat rate 6,876 kJ/kWh 6,778 kJ/kWh Width 4.6 m (15.09 ft) 4.0 m (13.12 ft) Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Number of gas turbines 1 2 Height 5.8 m (19.03 ft) 5.8 m (19.03 ft) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.
35
SGT-600
Industrial gas turbine
High reliability and availability in combination with good The industrial gas turbine combines a robust, reliable
fuel flexibility and third-generation DLE makes the SGT-600 design with high fuel flexibility and low emissions.
a perfect choice for several onshore applications:
Industrial power generation, oil and gas power generation, More than 330 units have been sold with over 9 million
and mechanical drive applications. Within the IPG applications, equivalent operating hours, and 185,000 equivalent
the turbine performs well in combined heat and power operating hours for the fleet-leading gas turbine.
plants and combined cycle plants.
References
Tiszaújváros, Hungary
Combined cycle power plant
Customer: TVK Ltd
Scope: 1 x SGT-600 gas turbine and
1 x SST-700 steam turbine
36
Power generation: 24.5 MW(e)
Mechanical drive: 25.3 MW
Robust, reliable design
High fuel flexibility
Low emissions
Maintainable, reliable, and robust twin-shaft design for mechanical drive and For both power generation and mechanical drive package,
power generation the driver is the same
Fuel Natural gas, liquid fuel, dual fuel Natural gas, liquid fuel, dual fuel
Frequency 50/60 Hz
NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)
Siemens combined SCC-600 1 × 1 SCC-600 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx.
Net power output 35.9 MW(e) 73.3 MW(e) weight 150,000 kg (330,693 lb) 59,000 kg (130,072 lb)
Net plant efficiency 49.9% 50.9% Length 18.8 m (61.68 ft) 11.7 m (38.38 ft)
Net heat rate 7,220 kJ/kWh 7,071 kJ/kWh Width 4.6 m (15.09 ft) 4.0 m (13.12 ft) Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Number of gas turbines 1 2 Height 5.8 m (19.03 ft) 5.8 m (19.03 ft) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.
37
SGT-500
Industrial gas turbine
Combining high overall efficiency and low maintenance burning heavy fuel oils (HFO), naphtha, and hydrogen
costs with long intervals between overhauls, the SGT-500 gases.
is positioned well for oil and gas power generation and
mechanical drive applications both onshore and offshore. More than 175 units have been sold with over 9 million
equivalent operating hours.
In addition to its proven, robust, and reliable design, the
SGT-500 has excellent fuel flexibility with the capability of
References
38
Power generation: 19.1 MW(e)
Mechanical drive: 19.3 MW
Fuel flexibility
Proven design
Easily maintained
SGT-500 core engine – proven and robust design SGT-500 offshore package – compact and
easily maintained
Fuel Natural gas, liquid, dual, HFO, crude oil Natural gas, liquid, dual, HFO, crude oil
Frequency 50/60 Hz
NOx emissions ≤ 42 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 42 ppmvd at 15% O2 on fuel gas (with DLE)
Physical dimensions
39
SGT-400
Industrial gas turbine
The SGT-400 is a twin-shaft gas turbine available in two With over 25 years of operating experience, the SGT-400
different power ratings for both power generation and is proven in both offshore and onshore applications.
mechanical drive applications. Over 300 units have been sold with approximately 3 million
The twin-shaft arrangement allows for commonality of hours operating experience.
parts in mixed-duty installations.
The gas turbine offers the highest efficiency in its power
class, incorporating the latest aerodynamic and combustion
technologies.
References
40
Power generation: 12.9/14.3 MW(e)
Mechanical drive: 13.4/14.9 MW
Latest aerodynamic and combustion
technology
Suitable for all climates, onshore
and offshore
High power-to-weight ratio
Twin-shaft design for both power generation and mechanical drive applications Compact power generation package design
Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load
Heat rate 10,355 kJ/kWh 10,178 kJ/kWh 9,943 kJ/kWh 9,774 kJ/kWh
Turbine speed 9,500 rpm 9,500 rpm 9,500 rpm 9,500 rpm
Exhaust gas flow 39.4 kg/s 44.3 kg/s 39.4 kg/s 44.0 kg/s
Exhaust temperature 555 °C (1,031 °F) 540 °C (1,004 °F) 555 °C (1,031 °F) 540 °C (1,004 °F)
NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)
Physical dimensions
41
SGT-300
Industrial gas turbine
The SGT-300 industrial gas turbine has a rugged industrial It operates on a wide range of gaseous and liquid fuels.
design that enables high efficiency, reliability, and The compact arrangement, on-site or off-site maintainability,
excellent emissions performance in a broad spectrum of and inherent reliability of the SGT-300 make it an ideal gas
applications for both power generation and mechanical turbine for the demanding oil and gas industry.
drive.
The gas turbine is a proven unit for all electrical power
generation and cogeneration applications.
References
42
Power generation: 7.9 MW(e)
Mechanical drive: 8.2 MW
Low maintenance requirements
Low emissions
Single-shaft version for power
generation, twin-shaft version for
mechancial drive applications
Twin-shaft design – evolutionary design focused on reliability SGT-300 gas turbine package design
Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load
Frequency 50/60 Hz
NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)
Physical dimensions
43
SGT-200
Industrial gas turbine
The rugged and compact SGT-200 gas turbine is available The SGT-200 gas turbine combines simple design with
as a single-shaft version for power generation, and as a state-of-the-art technology and is ideally suited for use,
twin-shaft turbine for mechanical drive. for example, as a compressor drive.
The gas turbine operates with various gaseous and liquid More than 430 units have been sold with more than
fuels. It provides high efficiency and an excellent power-to- 30 million equivalent operating hours.
weight ratio and is available as a factory-assembled package.
References
44
Power generation: 6.8 MW(e)
Mechanical drive: 7.7 MW
SGT-200 industrial gas turbine Shop-tested and certified fluid system modules, fully wired
and with onskid controls
Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load
Frequency 50/60 Hz
NOx emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)
Physical dimensions
45
SGT-100
Industrial gas turbine
The SGT-100 industrial gas turbine is a proven unit for The gas turbine has a rugged industrial design that enables
all electrical power generation and mechanical drive high efficiency and excellent emissions performance on a
applications. The compact arrangement, on-site or off-site wide range of gaseous and liquid fuels.
maintainability, and inherent reliability make it an ideal
gas turbine for the demanding oil and gas industry. More than 410 units have been sold with more than
24 million operating hours. The lead package has over
120,000 equivalent hours of operation.
References
Girvan, Scotland, UK
Combined heat and power
Customer: William Grant & Sons
distillery
Scope: 1 x SGT-100 gas turbine
cogeneration package
Able to provide its production process
with steam and electricity, and also to
supply electricity for the region
46
Power generation: 5.1/5.4 MW(e)
Mechanical drive: 5.7 MW
Robust, reliable, maintainable single-shaft version for Common modular package design for Common modular package design for
power generation applications power generation mechanical drive applications
Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load
NOx emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE)
Physical dimensions
47
Aeroderivative
gas turbines
Originally developed for use in aviation, aeroderivative
gas turbines are flexible, compact, and lightweight
designs that are ideally suited for power generation
and mechanical drives in the oil and gas industry.
Their high efficiency and fast start capabilities mean
that aeroderivative gas turbines also perform well in
decentralized power generation applications.
With a fleet of 2,500 installed units, millions of
operation hours in different environments have been
generated in numerous reference projects.
Industrial RB211...............................................................................52
Industrial 501...................................................................................54
Industrial Trent 60
Aeroderivative gas turbine
Designed for industrial use in power generation and speed conditions. It is available with Wet Low Emission
mechanical drive applications, the Industrial Trent 60 has (WLE) and DLE combustion systems.
established a new benchmark for power output, fuel
economy, and cost savings. The Industrial Trent 60 is proven in many different
environments including arctic, desert, tropical, and coastal
The gas turbine is highly flexible, offering high power and in different applications ranging from peaking to base load,
efficiency with minimal drop-off at part-load and reduced simple cycle, combined cycle, and mechanical drive.
References
50
Power generation: 53.1 – 66.0 MW(e)
Mechanical drive: 54.2 – 61.8 MW
Most powerful gas turbine in its class
Flexible with high cyclic life,
fast starts
Modular package design for quick
installation and maintenance
The Industrial Trent 60 can cold-start to full power in under 10 minutes Industrial Trent 60 package for power generation
and also has high cyclic life
50 Hz DLE 50 Hz DLE 60 Hz DLE 60 Hz DLE 50 Hz WLE 60 Hz WLE Power generation Mechanical drive
with ISI with ISI with ISI with ISI package package
Power output 53.1 MW(e) 63.5 MW(e) 54.0 MW(e) 61.8 MW(e) 66.0 MW(e) 65.7 MW(e) Approx. 208,000 kg 105,000 kg
weight (458,561 lb) (231,485 lb)
Fuel Natural gas only; other fuels on request Natural gas, liquid fuel, dual fuel;
other fuels on request Length 29.6 m (97 ft) 12.0 m (39.4 ft)
Gross efficiency 42.4% 43.2% 42.5% 43.4% 41.5% 41.1% Height 18.9 m (62 ft) 5.0 m (16.4 ft)
Heat rate 8,488 kJ/kWh 8,322 kJ/kWh 8,465 kJ/kWh 8,300 kJ/kWh 8,669 kJ/kWh 8,760 kJ/kWh
Turbine speed 3,000 rpm 3,000 rpm 3,600 rpm 3,600 rpm 3,000 rpm 3,600 rpm
Exhaust gas flow 155 kg/s 177 kg/s 158 kg/s 168 kg/s 180 kg/s 172 kg/s
Exhaust temperature 433 °C (811 °F) 416 °C (781 °F) 431 °C (808 °F) 421 °C (790 °F) 416 °C (781 °F) 426 °C (799 °F)
NOx emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with WLE and DLE)
Net power output 65.3 MW(e) 77.7 MW(e) 82.9 MW(e) 66.4 MW(e) 77.5 MW(e) 80.3 MW(e)
Note: Industrial Trent 60 WLE – water injected. ISI – Inlet Spray
Net plant efficiency 53.6% 53.4% 51.2% 53.5% 53.5% 50.7% Intercooling (wet compression water to the compressor).
All combined cycle performance is based on 2 pressure, no reheat.
Net heat rate 6,718 kJ/kWh 6,736 kJ/kWh 7,022 kJ/kWh 6,725 kJ/kWh 6,727 kJ/kWh 7,093 kJ/kWh For power generation, AC generator is included, dimensions include inlet
filter housing, exclude exhaust stack. For mechanical drive, driven equip-
Pressure/reheat Dual/No Dual/No Dual/No Dual/No Dual/No Dual/No ment is excluded, dimensions exclude inlet filter housing and exhaust
stack.
51
Industrial RB211
Aeroderivative gas turbine
With class-leading reliability and availability, the Industrial downtime and cost. Both conventional and DLE combustion
RB211 is a proven, dependable choice in power generation systems are available, including dual fuel capability.
and mechanical drive applications. It is qualified to meet
the stringent standards of the oil and gas industry in both In its 40-year evolution, the Industrial RB211 has
onshore and offshore service. accumulated over 36 million equivalent operating hours,
with over 750 units sold.
The aeroderivative gas generator is highly tolerant of
transient excursions and challenging mission cycles, and
can be easily exchanged at site, reducing maintenance
References
52
Power generation: 27.2 – 32.5 MW(e)
Mechanical drive: 27.9 – 33.8 MW
The Industrial RB211 is a two-spool gas generator aerodynamically Modular package design to meet specifications of a wide range of
coupled to a free power turbine applications
G62 DLE GT62 DLE GT61 DLE GT30 50Hz GT30 60Hz Power generation Mechanical drive
package package
Power output 27.2 MW(e) 29.8 MW(e) 32.1 MW(e) 32.5 MW(e) 31.5 MW(e)
Approx. 150,000 kg 99,000 kg
Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load weight (330,693 lb) (218,257 lb)
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50 Hz 60 Hz Length 16.0 m (52.49 ft) 9.2 m (30.2 ft)
Gross efficiency 36.4% 37.5% 39.3% 37.7% 36.4% Width 3.3 m (10.83 ft) 4 m (13.1 ft)
Heat rate 9,904 kJ / kWh 9,589 kJ / kWh 9,159 kJ / kWh 9,549 kJ / kWh 9,901 kJ / kWh Height 5.4 m (17.72 ft) 5 m (16.4 ft)
Turbine speed 4,800 rpm 4,800 rpm 4,850 rpm 3,600 rpm 3,000 rpm
Exhaust gas flow 91.0 kg/s 95.0 kg/s 94.0 kg/s 98.5 kg/s 99.8 kg/s
Exhaust temperature 501 °C (934 °F) 503 °C (937 °F) 510 °C (950 °F) 508 °C (946 °F) 512 °C (953 °F)
53
Industrial 501
Aeroderivative gas turbine
Based on proven aeroderivative design, the Industrial 501 fuel, steam, and water injection. DLE technology is also
delivers high efficiency and outstanding reliability for available.
power generation applications like cogeneration, offshore
platforms, and emergency power. The gas turbine offers The Industrial 501 has accumulated over 110 million
rugged, easy-to-maintain performance due to features such hours of operation with more than 500 customers in
as auxiliary equipment. 53 countries.
References
Grampian, Scotland
Combined heat and power plant
Customer: National Health Service,
Foresterhill Health Campus
Scope: 1 x Industrial 501-K gas turbine
54
Power generation: 3.9 – 6.4 MW(e)
Industrial 501 on a test stand at Siemens facility in Mount Power Generation with the Industrial 501
Vernon, Ohio, USA
Fuel Natural gas, liquid fuel, duel fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load
Physical dimensions
55
Heavy-duty
gas turbines
Aeroderivative
gas turbines
Industrial
gas turbines
References
Power output Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature
SGT-750 39.3 MW 41.5% 8,685 kJ / kWh 6,100 rpm 23.8 : 1 113.8 kg/s 458° C
SGT-700 33.7 MW 38.2% 9,424 kJ / kWh 6,500 rpm 18.7 : 1 95.0 kg/s 533° C
SGT-600 25.3 MW 34.6% 10,390 kJ / kWh 7,700 rpm 14.0 : 1 81.3 kg/s 543° C
SGT-500 19.3 MW 34.5% 10,530 kJ / kWh 3,450 rpm 13.0 : 1 97.9 kg/s 369° C
SGT-400 (15 MW) 14.9 MW 36.8% 9,774 kJ / kWh 9,500 rpm 18.9 : 1 44.0 kg/s 540° C
SGT-400 (13 MW) 13.4 MW 36.2% 9,943 kJ / kWh 9,500 rpm 16.8 : 1 39.4 kg/s 555° C
SGT-300 8.2 MW 34.6% 10,400 kJ / kWh 11,500 rpm 13.3 : 1 29.0 kg/s 498° C
SGT-200 7.7 MW 33.0% 10,906 kJ / kWh 10,950 rpm 12.3 : 1 29.5 kg/s 493° C
SGT-100 5.7 MW 32.9% 10,948 kJ / kWh 13,000 rpm 14.9 : 1 19.7 kg/s 543° C
Industrial Trent 60 DLE 54.2 MW 43.6% 8,256 kJ / kWh 3,400 rpm 34.3 : 1 154.4 kg/s 440° C
Industrial Trent 60 WLE 61.8 MW 41.9% 8,592 kJ / kWh 3,400 rpm 36.1 : 1 164.2 kg/s 422° C
Industrial RB211 G62 DLE 27.9 MW 37.3% 9,649 kJ / kWh 4,800 rpm 20.6 : 1 91.3 kg/s 501° C
Industrial RB211 G62 Non-DLE 29.1 MW 37.8% 9,542 kJ / kWh 4,800 rpm 21.3 : 1 93.4 kg/s 500° C
Industrial RB211 GT62 DLE 30.6 MW 38.6% 9,342 kJ / kWh 4,800 rpm 21.7 : 1 95.4 kg/s 503° C
Industrial RB211 GT62 Non-DLE 30.9 MW 38.6% 9,338 kJ / kWh 4,800 rpm 22.0 : 1 96.1 kg/s 501° C
Industrial RB211 GT61 DLE 33.0 MW 40.4% 8,923 kJ / kWh 4,850 rpm 21.6 : 1 93.8 kg/s 510° C
Industrial RB211 GT61 Non-DLE 33.8 MW 40.4% 8,913 kJ / kWh 4,850 rpm 22.1 : 1 95.0 kg/s 510° C
58
58
Mechanical drive applications (imperial units)
Power output Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature
SGT-750 39.3 MW 41.5% 8,232 Btu/kWh 6,100 rpm 23.8 : 1 250.9 lb/s 857° F
SGT-700 33.7 MW 38.2% 8,932 Btu/kWh 6,500 rpm 18.7 : 1 209.0 lb/s 991° F
SGT-600 25.3 MW 34.6% 9,848 Btu/kWh 7,700 rpm 14.0 : 1 179.0 lb/s 1,009° F
SGT-500 19.3 MW 34.5% 9,981 Btu/kWh 3,450 rpm 13.0 : 1 215.9 lb/s 697° F
SGT-400 (15 MW) 14.9 MW 36.8% 9,264 Btu/kWh 9,500 rpm 18.9 : 1 97.7 lb/s 1,004° F
SGT-400 (13 MW) 13.4 MW 36.2% 9,424 Btu/kWh 9,500 rpm 16.8 : 1 86.8 lb/s 1,031° F
SGT-300 8.2 MW 34.6% 9,857 Btu/kWh 11,500 rpm 13.3 : 1 63.9 lb/s 924° F
SGT-200 7.7 MW 33.0% 10,337 Btu/kWh 10,950 rpm 12.3 : 1 65.0 lb/s 919° F
SGT-100 5.7 MW 32.9% 10,377 Btu/kWh 13,000 rpm 14.9 : 1 43.4 lb/s 1,009° F
Industrial Trent 60 DLE 54.2 MW 43.6% 7,825 Btu/kWh 3,400 rpm 34.3 : 1 340.4 lb/s 824° F
Industrial Trent 60 WLE 61.8 MW 41.9% 8,144 Btu/kWh 3,400 rpm 36.1 : 1 362.0 lb/s 792° F
Industrial RB211 G62 DLE 27.9 MW 37.3% 9,145 Btu/kWh 4,800 rpm 20.6 : 1 201.3 lb/s 934° F
Industrial RB211 G62 Non-DLE 29.1 MW 37.8% 9,044 Btu/kWh 4,800 rpm 21.3 : 1 205.9 lb/s 932° F
Industrial RB211 GT62 DLE 30.6 MW 38.6% 8,855 Btu/kWh 4,800 rpm 21.7 : 1 210.3 lb/s 937° F
Industrial RB211 GT62 Non-DLE 30.9 MW 38.6% 8,851 Btu/kWh 4,800 rpm 22.0 : 1 211.9 lb/s 934° F
Industrial RB211 GT61 DLE 33.0 MW 40.4% 8,457 Btu/kWh 4,850 rpm 21.6 : 1 206.8 lb/s 950° F
Industrial RB211 GT61 Non-DLE 33.8 MW 40.4% 8,448 Btu/kWh 4,850 rpm 22.1 : 1 209.4 lb/s 950° F
59
59
Simple cycle power generation (metric units)
Power output Frequency Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature
SGT5-8000H 400 MW 50 Hz 40.0% 8,999 kJ/kWh 3,000 rpm 19.2 : 1 869.0 kg/s 627° C
SGT6-8000H 296 MW 60 Hz 40.0% 8,999 kJ/kWh 3,600 rpm 19.5 : 1 640.0 kg/s 630° C
SGT5-4000F 307 MW 50 Hz 40.0% 9,001 kJ/kWh 3,000 rpm 18.8 : 1 723.0 kg/s 579° C
SGT6-5000F 242 MW 60 Hz 39.0% 9,230 kJ/kWh 3,600 rpm 18.9 : 1 576.0 kg/s 600° C
SGT5-2000E 187 MW 50 Hz 36.2% 9,945 kJ/kWh 3,000 rpm 12.1 : 1 558.0 kg/s 536° C
SGT6-2000E 116 MW 60 Hz 34.3% 10,496 kJ/kWh 3,600 rpm 12.1 : 1 367.0 kg/s 537° C
SGT-800 (53.0 MW) 53.0 MW(e) 50/60 Hz 39.0% 9,231 kJ/kWh 6,608 rpm 21.4 : 1 137.2 kg/s 551 °C
SGT-800 (50.5 MW) 50.5 MW(e) 50/60 Hz 38.3% 9,389 kJ/kWh 6,608 rpm 21.0 : 1 134.2 kg/s 553 °C
SGT-800 (47.5 MW) 47.5 MW(e) 50/60 Hz 37.7% 9,547 kJ/kWh 6,608 rpm 20.1 : 1 132.8 kg/s 541° C
SGT-750 38.1 MW(e) 50/60 Hz 40.2% 8,953 kJ/kWh 6,100 rpm 23.8 : 1 113.8 kg/s 458° C
SGT-700 32.8 MW(e) 50/60 Hz 37.2% 9,675 kJ/kWh 6,500 rpm 18.7 : 1 95.0 kg/s 533° C
SGT-600 24.5 MW(e) 50/60 Hz 33.6% 10,720 kJ/kWh 7,700 rpm 14.0 : 1 81.3 kg/s 543° C
SGT-500 19.1 MW(e) 50/60 Hz 33.8% 10,690 kJ/kWh 3,600 rpm 13.0 : 1 97.9 kg/s 369° C
SGT-400 (15 MW) 14.3 MW(e) 50/60 Hz 35.4% 10.178 kJ/kWh 9,500 rpm 18.9 : 1 44.3 kg/s 540° C
SGT-400 (13 MW) 12.9 MW(e) 50/60 Hz 34.8% 10.355 kJ/kWh 9,500 rpm 16.8 : 1 39.4 kg/s 555° C
SGT-300 7.9 MW(e) 50/60 Hz 30.6% 11,773 kJ/kWh 14,010 rpm 13.7 : 1 30.2 kg/s 542° C
SGT-200 6.8 MW(e) 50/60 Hz 31.5% 11,418 kJ/kWh 11,053 rpm 12.2 : 1 29.3 kg/s 466° C
SGT-100 (5.4 MW) 5.4 MW(e) 50/60 Hz 31.0% 11,613 kJ/kWh 17,384 rpm 15.6 : 1 20.6 kg/s 531° C
SGT-100 (5.1 MW) 5.1 MW(e) 50/60 Hz 30.2% 11,914 kJ/kWh 17,384 rpm 14.0 : 1 19.5 kg/s 545° C
Industrial Trent 60 DLE 53.1 MW(e) 50 Hz 42.4% 8,488 kJ/kWh 3,000 rpm 33.3 : 1 155.0 kg/s 433° C
Industrial Trent 60 DLE with ISI 63.5 MW(e) 50 Hz 43.2% 8,322 kJ/kWh 3,000 rpm 37.9 : 1 177.0 kg/s 416° C
Industrial Trent 60 DLE 54.0 MW(e) 60 Hz 42.5% 8,465 kJ/kWh 3,600 rpm 33.6 : 1 158.0 kg/s 431° C
Industrial Trent 60 DLE with ISI 61.8 MW(e) 60 Hz 43.4% 8,300 kJ/kWh 3,600 rpm 36.2 : 1 168.0 kg/s 421° C
Industrial Trent 60 WLE with ISI 66.0 MW(e) 50 Hz 41.5% 8,669 kJ/kWh 3,000 rpm 39.0 : 1 180.0 kg/s 416° C
Industrial Trent 60 WLE with ISI 65.7 MW(e) 60 Hz 41.1% 8,760 kJ/kWh 3,600 rpm 38.0 : 1 172.0 kg/s 426° C
Industrial RB211 G62 DLE 27.2 MW(e) 50/60 Hz 36.4% 9,904 kJ/kWh 4,800 rpm 20.6 : 1 91.0 kg/s 501° C
Industrial RB211 GT62 DLE 29.8 MW(e) 50/60 Hz 37.5% 9,589 kJ/kWh 4,800 rpm 21.7 : 1 95.0 kg/s 503° C
60
Industrial RB211 GT61 DLE 32.1 MW(e) 50/60 Hz 39.3% 9,159 kJ/kWh 4,850 rpm 21.6 : 1 94.0 kg/s 510° C
Industrial RB211 GT30 50 Hz 32.5 MW(e) 50 Hz 37.7% 9,549 kJ/kWh 3,000 rpm 22.7 : 1 98.5 kg/s 508° C
Industrial RB211 GT30 60 Hz 31.5 MW(e) 60 Hz 36.4% 9,901 kJ/kWh 3,600 rpm 22.9 : 1 99.8 kg/s 512° C
Industrial 501 (6.4 MW) 6.4 MW(e) 50/60 Hz 40.1% 8,971 kJ/kWh 14,600 rpm 12.5 : 1 18.4 kg/s 530 °C
Industrial 501 (5.2 MW) 5.2 MW(e) 50/60 Hz 31.5% 11,445 kJ/kWh 14,600 rpm 13.9 : 1 21.1 kg/s 498 °C
Industrial 501 (3.9 MW) 3.9 MW(e) 50/60 Hz 29.0% 12,393 kJ/kWh 14,200 rpm 10.3 : 1 15.4 kg/s 560° C
60
Simple cycle power generation (imperial units)
Power output Frequency Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature
SGT5-8000H 400 MW 50 Hz 40.0% 8,530 Btu/kWh 3,000 rpm 19.2 : 1 1,915.0 lb/s 1,161° F
SGT6-8000H 296 MW 60 Hz 40.0% 8,530 Btu/kWh 3,600 rpm 19.5 : 1 1,410.0 lb/s 1,166° F
SGT5-4000F 307 MW 50 Hz 40.0% 8,532 Btu/kWh 3,000 rpm 18.8 : 1 1,595.0 lb/s 1,074° F
SGT6-5000F 242 MW 60 Hz 39.0% 8,748 Btu/kWh 3,600 rpm 18.9 : 1 1,270.0 lb/s 1,113° F
SGT5-2000E 187 MW 50 Hz 36.2% 9,427 Btu/kWh 3,000 rpm 12.1 : 1 1,230.0 lb/s 997° F
SGT6-2000E 116 MW 60 Hz 34.3% 9,949 Btu/kWh 3,600 rpm 12.1 : 1 809.0 lb/s 999° F
SGT-800 (53.0 MW) 53.0 MW(e) 50/60 Hz 39.0% 8,749 Btu/kWh 6,608 rpm 21.4 : 1 302.5 lb/s 1,024° F
SGT-800 (50.5 MW) 50.5 MW(e) 50/60 Hz 38.3% 8,899 Btu/kWh 6,608 rpm 21.0 : 1 295.8 lb/s 1,027° F
SGT-800 (47.5 MW) 47.5 MW(e) 50/60 Hz 37.7% 9,048 Btu/kWh 6,608 rpm 20.1 : 1 292.8 lb/s 1,007° F
SGT-750 38.1 MW(e) 50/60 Hz 40.2% 8,486 Btu/kWh 6,100 rpm 23.8 : 1 250.9 lb/s 856.5° F
SGT-700 32.8 MW(e) 50/60 Hz 37.2% 9,170 Btu/kWh 6,500 rpm 18.7 : 1 209.0 lb/s 991° F
SGT-600 24.5 MW(e) 50/60 Hz 33.6% 10,161 Btu/kWh 7,700 rpm 14.0 : 1 179.0 lb/s 1,009° F
SGT-500 19.1 MW(e) 50/60 Hz 33.8% 10,132 Btu/kWh 3,600 rpm 13.0 : 1 215.9 lb/s 697° F
SGT-400 (15 MW) 14.3 MW(e) 50/60 Hz 35.4% 9,647 Btu/kWh 9,500 rpm 18.9 : 1 97.7 lb/s 1,004° F
SGT-400 (13 MW) 12.9 MW(e) 50/60 Hz 34.8% 9,815 Btu/kWh 9,500 rpm 16.8 : 1 86.8 lb/s 1,031° F
SGT-300 7.9 MW(e) 50/60 Hz 30.6% 11,158 Btu/kWh 14,010 rpm 13.7 : 1 66.6 lb/s 1,008° F
SGT-200 6.8 MW(e) 50/60 Hz 31.5% 10,822 Btu/kWh 11,053 rpm 12.2 : 1 64.5 lb/s 871° F
SGT-100 (5.4 MW) 5.4 MW(e) 50/60 Hz 31.0% 11,007 Btu/kWh 17,384 rpm 15.6 : 1 45.4 lb/s 988° F
SGT-100 (5.1 MW) 5.1 MW(e) 50/60 Hz 30.2% 11,292 Btu/kWh 17,384 rpm 14.0 : 1 43.1 lb/s 1,013° F
Industrial Trent 60 DLE 53.1 MW(e) 50 Hz 42.4% 8,045 Btu/kWh 3,000 rpm 33.3 : 1 342.0 lb/s 811° F
Industrial Trent 60 DLE with ISI 63.5 MW(e) 50 Hz 43.2% 7,888 Btu/kWh 3,000 rpm 37.9 : 1 390.0 lb/s 781° F
Industrial Trent 60 DLE 54.0 MW(e) 60 Hz 42.5% 8,023 Btu/kWh 3,600 rpm 33.6 : 1 348.0 lb/s 808° F
Industrial Trent 60 DLE with ISI 61.8 MW(e) 60 Hz 43.4% 7,867 Btu/kWh 3,600 rpm 36.2 : 1 370.0 lb/s 790° F
Industrial Trent 60 WLE with ISI 66.0 MW(e) 50 Hz 41.5% 8,217 Btu/kWh 3,000 rpm 39.0 : 1 397.0 lb/s 781° F
Industrial Trent 60 WLE with ISI 65.7 MW(e) 60 Hz 41.1% 8,303 Btu/kWh 3,600 rpm 38.0 : 1 379.0 lb/s 799° F
Industrial RB211 G62 DLE 27.2 MW(e) 50/60 Hz 36.4% 9,387 Btu/kWh 4,800 rpm 20.6 : 1 200.6 lb/s 934° F
Industrial RB211 GT62 DLE 29.8 MW(e) 50/60 Hz 37.5% 9,089 Btu/kWh 4,800 rpm 21.7 : 1 209.4 lb/s 937° F
61
Industrial RB211 GT61 DLE 32.1 MW(e) 50/60 Hz 39.3% 8,681 Btu/kWh 4,850 rpm 21.6 : 1 207.2 lb/s 950° F
Industrial RB211 GT30 50 Hz 32.5 MW(e) 50 Hz 37.7% 9,051 Btu/kWh 3,000 rpm 22.7 : 1 217.2 lb/s 946° F
Industrial RB211 GT30 60 Hz 31.5 MW(e) 60 Hz 36.4% 9,384 Btu/kWh 3,600 rpm 22.9 : 1 220.0 lb/s 953° F
Industrial 501 (6.4 MW) 6.4 MW(e) 50/60 Hz 40.1% 8,503 Btu/kWh 14,600 rpm 12.5 : 1 40.6 lb/s 986° F
Industrial 501 (5.2 MW) 5.2 MW(e) 50/60 Hz 31.5% 10,848 Btu/kWh 14,600 rpm 13.9 : 1 46.5 lb/s 928° F
Industrial 501 (3.9 MW) 3.9 MW(e) 50/60 Hz 29.0% 11,746 Btu/kWh 14,200 rpm 10.3 : 1 34.0 lb/s 1,040° F
61
Published by
Siemens Energy, Inc.
Article-No. PGDG-B10006-00-4AUS
Printed in Germany
Dispo 34806 BR 11152.0