Nitoflor FC110 constructive solutions

A clear polyurethane floor coating and sealer

Uses Chemical properties

To provide a clear sealing coat on cementitious floors and a Nitoflor FC110 is resistant to a range of chemicals. Specific
dust-proof and more easily cleaned surface with resistance to data is available on request.
the penetration of oils and liquids. Ideal for warehousing,
garages and light industrial buildings. Maintenance

The service life of a floor can be considerable extended by


Advantages good housekeeping practices. Regular cleaning of Nitoflor
FC110 may be carried out using a rotary scrubbing machine
 Simple brush or spray application. with a water miscible cleaning agent, or by hot water
o
 Prevents dusting by sealing the surface. washing at temperatures up to 50 C.
 Aids floor cleaning and maintenance.
 Durable finish offers good resistance to abrasion. Specification clauses
 Single component - no mixing.
The floor sealer shall be Nitoflor FC110, a single
component, clear polyurethane coating for application by
Description brush. The coating shall be applied in a minimum of two
2
coats at a coverage rate not greater than 9 m /litre per coat.
Nitoflor FC110 single component, moisture curing
polyurethane coating shows excellent adhesion to concrete
Application instructions
and, when cured, forms a clear, semi-gloss flexible film.

It is supplied in a single pack ready for use direct from the Surface preparation
can. Two coats are recommended.
It is essential that Nitoflor FC110 is applied to sound, clean
dry substrates in order to achieve maximum adhesion
Technical support between the floor coating and substrate.

Fosroc offers a comprehensive range of high performance, Because Nitoflor FC110 is a relatively thin coating, the
high quality flooring, jointing and repair products for both new substrate must be fine textured. Any surface irregularities
and existing floor surfaces. In addition, Fosroc offers a will show through causing excessive wear on high sports.
technical support package to specifiers, end users, and
contractors, as well as on-site technical assistance in New concrete floors
locations all over the world.
Unless water-reduced, the floor should be at least 28 days
Design criteria old. Dry removal of laitance by light grit-blasting is
preferable but, where this is not feasible, treat with an acid
wash, followed by thorough rising with water and complete
Nitoflor FC110 is designed for application in two coats to
drying. Dust and other debris should then be removed by
achieve an approximate total dry film thickness of 100
vacuum brush.
microns. Substrates should have a relative humidity not
greater than 80% at the time of installation.
Old concrete floors

Properties A sound, clean substrate is essential to achieve maximum


adhesion. Light grit blasting or acid etching should be
The values given above right have been achieved in carried out as for new concrete floors. Oil and grease
laboratory tests. Actual values attained on site may show penetration should be removed with a chemical degreaser.
minor variations from those quoted.
Coating
o
Physical properties is at 20 C
The contents of the can should be poured into a plastic tray
Time between coats: 1 hour minimum or similar and applied on to the surface using a soft brush.
Initial hardness: 24 hours A continuous coating of uniform thickness should be
Full cure: 7 days achieved. A minimum of two coats are recommended
Dry film thickness (2 coats): 100 microns (approx) allowing at least 1 to 2 hours drying time between coats.

Page 1
Nitoflor FC110
On sand/cement screeds, 3 or 4 coats may be required Precautions
depending on porosity. Where two or more coats are
applied, best results are obtained by not allowing more than Health and safety
24 hours between applications.
Nitoflor FC110 and Fosroc Solvent 102 should not come in
Cleaning contact with skin and eyes, or be swallowed. Avoid
inhalation of vapour/spray. Use only in well ventilated
Nitoflor FC110 should be removed from tools and areas. If working in confined areas, suitable respirator
equipment using Fosroc Solvent 101 immediately after use. protective equipment must be worn. Wear suitable
protective clothing, gloves and eye/face protection. Barrier
Limitations creams provide additional skin protection.

The durability of Nitoflor FC110 is reduced in areas of very Should accidental skin contact occur, remove with a suitable
heavy foot traffic such as around workbenches, drinks skin cleanser, followed b washing with soap and water. In
machines, doorways etc. It is advisable to either: case of contact wit eyes, rinse immediately with plenty of
water and seek medical advice. If swallowed seek medical
a) Specify additional coats in such areas or attention immediately - do not induce vomiting.
b) Specify a higher build system such as Nitoflor FC150 in
such areas (see relevant data sheet). Fire

Nitoflor FC110 and Fosroc Solvent 101 are flammable.


Estimating Store in accordance with national and local fire prevention
regulations. Keep away from sources of ignition. No
Supply smoking. In the event of fire, extinguish with CO 2 or foam.
Do not use a water jet.
Nitoflor FC110: 5 litre packs
Fosroc Solvent 101: 10 litre cans Flash points

Coverage Nitoflor FC110 and Fosroc Solvent 102 are flammable.


Store in accordance with national and local fire prevention
2
Nitoflor FC110: 5 to 9 m /litre/coat
o
Nitoflor FC110: 24 C
o
The coverage figures give are theoretical - due to wastage Fosroc Solvent 101: 43 C
factors and the variety and nature of possible substrates,
practical coverage figures will be reduced. Disposal

Spillages of component products should be absorbed onto


Storage
earth, sand or other inert material and transferred to a
suitable vessel. Disposal of such spillages or empty
Shelf life
packaging should be in accordance with local waste
disposal regulations.
All products have a shelf life of 6 months if kept in a dry sore
in the original unopened packs.
For further information, refer to the Product Safety Data
Sheet.
Storage conditions
o o
Store in dry conditions between 10 C and 30 C, away from
sources of heat and naked flames, in the original unopened
packs. If stored at high temperatures the shelf life will be
reduced. Nitoflor FC110 should be protected from frost.

Important note:
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions
for the Supply of Goods and Services, copies of which may be obtained on request. Whilst Fosroc endeavours to ensure that
any advice, recommendation, specification of information it may give is accurate and correct, it cannot, because it has no direct
or continuous control over where or how its products are applied, accept any liability either directly or indirectly arising from the
use of its products, whether or not in accordance with any advice, specification, recommendation of information given by it.

Fosam Company Limited


Head Office Telephone: +966 2 637 5345 Fax: +966 2 637 5891 email: fosam@fosroc.com
Post Box 11081 Regional Offices
Jeddah – 21453 Jeddah Sales Office Tel: (02) 608 0999 Fax: (02) 638 0693 Yanbu Tel: (04) 322 4280 Fax: (04) 391 2980
Jeddah Showroom Tel: (02) 665 0187 Fax: (02) 667 4844 Makkah Tel: (02) 542 0869 Fax: (02) 542 0869
Saudi Arabia Riyadh Tel: (01) 482 9303 Fax: (01) 482 7562 Medinah Tel: (04) 855 0091 Fax: (04) 855 0047
Dammam Tel: (03) 814 1282 Fax: (03) 814 1581 Jubail Tel: (03) 362 3904 Fax: (03) 362 3875
www.fosroc.com Khamis Mushayt Tel: (07) 250 0469 Fax: (07) 250 0469 CSD Tel: (02) 608 0999 Fax: (02) 638 0693

Registered Office: Industrial Area, Phase 4, Road No. 414, Street No. 407
Page 2 SA FO/NITOFLOR FC110/05/A