You are on page 1of 3

Given Data

Mortar type = M2
Compressive strength of brick = 10 N/mm2
Grade of Concrete = M20
Grade of Steel = Fe415

Wall in Grid 1-1


basic compressive strength of masonry = 0.81 N/mm2 Table 8

H/8 = 0.35625
H/6 = 0.475
Effective length of wall = L = 5m
Effective heigth of wall = h = 0.75H = 2.138 m

Slenderness ratio = 2.138/0.35 = 6.1086

From Table 9
Ks = 0.997

Area reduction factor


A= 0.7788 > 0.2
ka = 1

From table 10
Kp = 1

fc = 0.8076 N/mm2

Permissible shear stress = 0.1 N/mm2 From test

Load Calculation
Slab load
Dead load = 2.5 Kn/m2
Live load = 3 KN/m2
Finishing load = 1 KN/m2
First floor
Dead load due to slab = 17.88906 KN
Live load above = 16.21688 KN
load due to floor finishing = 5.405625 KN
Roof Floor
Dead load due to slab = 17.88906 KN
Live load above = 9.375 KN
load due to floor finishing = 6.25 KN

wall load
first floor wall UDL = 18.2875 KN/m
Wall load above sill = 14.2975 Kn/m
wall length = 2.225 m

Wall stress
Load on pier
due to dead load= 21.11 KN
Due to live load = 11.39 KN
Due to wall load
first floor = 40.69 KN
Ground Floor = 31.81 KN 93.61 0.77875 120.205

Compressive stress
Due to dead load = 120.205 KN/m2
= 0.12021 N/mm2
Permissible sheawr stress
= 0.120 N/mm2

Seismic Analysis
Time peroid = 0.2393 s
C = 0.08
Z = 1
I = 1.5
K = 2.5

Cd = 0.3

Lumped mass = 296+412 = 708 KN

Base Shear = 212.4 KN

Storey Shear
S.n Storey level Seismic Weight Storey Level Wihi Design lateral force Storey Shear
1 2 296 5.7 1687.2 125.24 125.240
2 1 412 2.85 1174.2 87.160 212.4
1535 EQx LinStatic -3.473 0.399 -4.042 0 0 0
1536 EQx LinStatic -3.076 0.166 1.122 0 0 0
2 EQx LinStatic -1.836 -0.615 -10.382 0 0 0
22 EQx LinStatic -5.335 0.13 2.047 0 0 0
3238 EQx LinStatic -2.001 0.111 -0.58 0 0 0
Sum -15.721