You are on page 1of 2

PV Elite 2019 Licensee: VENVEL THERMAL & MECH.

DESIGNERS 1
FileName : ASME-DCN-2018
Nozzle Summary: Step: 74 1:56pm Apr 1,2019

Nozzle Calculation Summary:

Description | MAWP | Ext | MAPNC | UG-45 [tr] | Weld | Areas or |


| psig | | psig | | mm | Path | Stresses |
----------------------------------------------------------------------------------------------
D-CONDEN IN/OUT | 955.43 | ... | ... | OK | 7.80 | OK | Passed |
E1-LEVEL GAUGE1 | 828.79 | ... | ... | OK | 6.42 | OK | No Calc[*] |
E2-LEVEL GAUGE | 828.79 | ... | ... | OK | 6.42 | OK | No Calc[*] |
F-LEVEL RADAR | 613.12 | ... | ... | OK | 8.73 | OK | Passed |
B-COND. IN CFID | 861.44 | ... | ... | OK | 6.42 | OK | No Calc[*] |
C-RELIEF VALVE | 861.44 | ... | ... | OK | 6.42 | OK | No Calc[*] |
----------------------------------------------------------------------------------------------

MAWP Summary:
Minimum MAWP Nozzles : 613.118 Nozzle : F-LEVEL RADAR
Minimum MAWP Shells/Flanges : 828.792 Element : Shell- B36.10
Minimum MAPnc Shells/Flanges : 1190.049 Element : Blind flange App2
--------------------------------------------------------------------------
Computed Vessel M.A.W.P. : 613.118 psig

[*] - This was a small opening and the areas were not computed or
the MAWP of this connection could not be computed because
the longitudinal bending stress was greater than the hoop stress.

Note: MAWPs (Internal Case) shown above are at the High Point.

Warning: A Nozzle Reinforcement is governing the MAWP of this Vessel.

Check the Spatial Relationship between the Nozzles

From Node | Nozzle Description | Y Coordinate | Layout Angle | Dia. Limit |


| | mm | deg | mm |
------------------------------------------------------------------------------
10 | D-CONDEN IN/OUT | 0.000 | 0.000 | 150.000 |
20 | E1-LEVEL GAUGE1 | 616.000 | 180.000 | 98.325 |
20 | E2-LEVEL GAUGE | 260.000 | 180.000 | 98.325 |
40 | F-LEVEL RADAR | 0.000 | 0.000 | 230.000 |
40 | B-COND. IN CFID | 0.000 | 225.000 | 80.000 |
40 | C-RELIEF VALVE | 0.000 | 315.000 | 80.000 |

The nozzle spacing is computed by the following:


= Sqrt( ll² + lc² ) where
ll - Arc length along the inside vessel surface in the long. direction.
lc - Arc length along the inside vessel surface in the circ. direction

If any interferences/violations are found, they will be noted below.


No interference violations have been detected !

Checking Multiple Nozzles on Flat Head per ASME Sec. VIII Div. 1 UG-39

Comparing Nozzles on Element: Blind flange App2

UG-39 Average Nozzle Diameter and Ligament Checks:

Nozzle | Avg. | Head Dia.| Ligament | Min. dn |


Pair Description | dia. | /4 | Width | /4 |
| mm | mm | mm | mm |
-----------------------------------------------------------------
F-LEVEL RADAR & B-CON| 65.525 | 166.69 | 141.16 | 12.212 |
F-LEVEL RADAR & C-REL| 65.525 | 166.69 | 141.16 | 12.212 |
B-COND. IN CFID & C-R| 48.85 | 166.69 | 264.94 | 12.212 |
-----------------------------------------------------------------
PV Elite 2019 Licensee: VENVEL THERMAL & MECH. DESIGNERS 2
FileName : ASME-DCN-2018
Nozzle Summary: Step: 74 1:56pm Apr 1,2019

UG-39 Nozzle Spacing and Average Area Checks:

Nozzle | Center | Avg. dia.| Avg. Area | Avg. Area |


Pair Description | Spacing | * 1.25 | Available | Reqd. |
| mm | mm | mm² | mm² |
-------------------------------------------------------------------
F-LEVEL RADAR & B-CON| 230 | 81.906 | No Calc | No Calc |
F-LEVEL RADAR & C-REL| 230 | 81.906 | No Calc | No Calc |
B-COND. IN CFID & C-R| 325.27 | 61.062 | No Calc | No Calc |
-------------------------------------------------------------------

UG-39 Nozzle Diameter and Distance to Edge Checks:

Nozzle | Nozzle | Head Dia. | Distance | Nozzle |


Description | dia. | /2 | from Edge | dia./4 |
| mm | mm | mm | mm |
-------------------------------------------------------------------
F-LEVEL RADAR | 82.2 | 333.38 | 411.23 | 20.55 |
B-COND. IN CFID | 48.85 | 333.38 | 209.74 | 12.212 |
C-RELIEF VALVE | 48.85 | 333.38 | 209.74 | 12.212 |
-------------------------------------------------------------------

No Multiple Nozzle spacing violations have been detected !