This document provides formulas for calculating various well intervention pressure and fluid parameters. It defines common abbreviations used and lists 7 formulas for: 1) calculating pressure gradient from fluid density, 2) calculating fluid density from hydrostatic pressure and true vertical depth, 3) calculating hydrostatic pressure from fluid density and true vertical depth, 4) calculating formation pressure from pressure gradient and true vertical depth, 5) calculating total pressure in a shut-in wellbore, and 6) calculating time and strokes to displace fluid when pumping in either the tubing or annulus.
This document provides formulas for calculating various well intervention pressure and fluid parameters. It defines common abbreviations used and lists 7 formulas for: 1) calculating pressure gradient from fluid density, 2) calculating fluid density from hydrostatic pressure and true vertical depth, 3) calculating hydrostatic pressure from fluid density and true vertical depth, 4) calculating formation pressure from pressure gradient and true vertical depth, 5) calculating total pressure in a shut-in wellbore, and 6) calculating time and strokes to displace fluid when pumping in either the tubing or annulus.
This document provides formulas for calculating various well intervention pressure and fluid parameters. It defines common abbreviations used and lists 7 formulas for: 1) calculating pressure gradient from fluid density, 2) calculating fluid density from hydrostatic pressure and true vertical depth, 3) calculating hydrostatic pressure from fluid density and true vertical depth, 4) calculating formation pressure from pressure gradient and true vertical depth, 5) calculating total pressure in a shut-in wellbore, and 6) calculating time and strokes to displace fluid when pumping in either the tubing or annulus.
bar/m = Bar per metre BHP = Bottom Hole Pressure kg/l = Kilogram per litre l/m = Litre per metre l/min = Litre per minute l/stroke = Litre per stroke m = Metre MD = Measured Depth TVD = True Vertical Depth SIWHP = Shut in Well Head Pressure 10.2 = Constant factor
1. PRESSURE GRADIENT (bar/m)
Fluid Density (kg/l)
10.2
2. FLUID DENSITY (kg/l)
Hydrostatic Pressure (bar) x 10.2
TVD (m)
3. HYDROSTATIC PRESSURE (bar)
Fluid Density (kg/l) x TVD (m)
10.2
or
Pressure Gradient (bar/m) x TVD (m)
4. FORMATION PRESSURE (bar)
Pressure Gradient (bar/m) x TVD (m)
5. TOTAL PRESSURE AT A GIVEN DEPTH IN A SHUT IN WELLBORE (bar)
(Where BHP = Formation Pressure)
Hydrostatic pressure of Gas (bar) + Hydrostatic Pressure of Oil (bar) + SIWHP (bar)
April 2016 EX-0041 Version 1.0 Page 1 of 2
Printed copies are UNCONTROLLED: It is the user’s responsibility to verify printed material against the controlled document Well Intervention – English Metric 10.2 – Formula Sheet
6. TIME TO PUMP (minutes)
Tubing Capacity (l/m) x MD (m)
a. Tubing Pump Rate (l/min)
Annulus Capacity (l/m) x MD (m)
b. Annulus Pump Rate (l/min)
7. STROKES TO DISPLACE (Strokes)
Tubing Capacity (l/m) x MD (m)
a. Tubing Pump Displacement (l/stroke)
Annulus Capacity (l/m) x MD (m)
b. Annulus Pump Displacement (l/stroke)
April 2016 EX-0041 Version 1.0 Page 2 of 2
Printed copies are UNCONTROLLED: It is the user’s responsibility to verify printed material against the controlled document