Design Summary
2.) Hence Required Base Plate Length "L" 250 mm Ref:IS456, CL:34.4
3.) Hence Required Base Plate Width "W" 250 mm Ref:IS456, CL:34.4
CONNECTION DESIGN AS PER IS800-2007, IS4000-1992
COLUMN BASE PLATE CONNECTION
Concrete bearing area under the column A c=(Fy)/(fcu x 0.45 ) as per limit state = 14223.000 mm2 IS456, CL:34.4
Concrete bearing area under the column A c=(Fy)/(fcu x 0.24 ) as per WS = 26667.000 mm2
= 14223.000 mm2
= 250 mm
= 250 mm
Pressure due to Compressive load "w 1=fy / Base plate area" = 2.560 N/mm2
0.503
SAFE
THICKNESS
IS:800-
(a)Thickness of base plate is t = √((2.5 * w) * (a2 -0.3 x b2)x (ɣm0 /fy) = 14.257 mm
2007,CL:7.4.3.1
Ref:From Dr.Satish
(b)Thickness of base plate t=√(6 x M1/ Bp x (fy/ɣm0)) Kumar, IIT Madras,
Ref:IS800-2007 CL:11.3.3 M1= 14514.944 N-mm Journal
Where B p is width of base plate as unit M2= 13593.600 N-mm "w" is considered in unit UDL
M3= 56524.917 N-mm
M4= 97256.729 N-mm
M(max)= 97256.729 N-mm
t= 16.024 mm
Stiffner NO