You are on page 1of 45

Shop Inspections of

Alloy Pipes

G Kannappan
Raghavendra Shenoy
16.05.2017
Knowledge City, Vadodara

1 / 45 QMCC | 26.06.2013
Contents

➢ Raw Material Inspection

➢ In-Process Inspection

➢ Final Inspection

➢ Non-Conformities

➢ Manufacturer Audit

2 / 45 QMCC | 26.06.2013
Testing Requirements
➢ Requirements are in:

➢ Material Specification (ASME Sec II)

➢ Supplementary Tests

➢ Customer Requirements

➢ Ordering Information: Write in PO

➢ Tests at Shop & Field: Mention in agreed QAP & FQAP resp.,

3 / 45 QMCC | 26.06.2013
Raw Material Inspection

4 / 45 QMCC | 26.06.2013
Raw Material Identification

Billets identification

5 / 45 QMCC | 26.06.2013
Raw Material Identification

Stamping

6 / 45 QMCC | 26.06.2013
Raw Material Testing

Etching Macro-Structure

7 / 45 QMCC | 26.06.2013
Raw Material Testing

All the heat numbers chemical composition


8 / 45 QMCC | 26.06.2013
Raw Material Testing

Micro Testing for the forged billets


9 / 45 QMCC | 26.06.2013
Pipe – Heat Treatment

Pipes’ heat treatment records & charts (Normalizing &


Tempering) reviewed as per applicability of code / TDC
10 / 45 QMCC | 26.06.2013
Finished Pipes Inspection

11 / 45 QMCC | 26.06.2013
Finished Pipe - Identification

Identification made at the billet stage is maintained


till the testing is finished
12 / 45 QMCC | 26.06.2013
Finished Pipe – Identification/Marking

All the pipes marked with following information:


P.O No., Manufacturer Name, Specification, Dimension (OD X Thick X Length),
Heat No., Year - Month, Inspector Seal, SAP Material Code, NDE
13 / 45 QMCC | 26.06.2013
Finished Pipe – Color Coding

SA 106 B Pipe with Red - Longitudinal

14 / 45 QMCC | 26.06.2013
Finished Pipe – Color Coding

P22 Pipe with Red & Blue - Longitudinal


15 / 45 QMCC | 26.06.2013
Finished Pipe – Color Coding

P91 Pipe with Brown & Red - Longitudinal


16 / 45 QMCC | 26.06.2013
Finished Pipe – Color Coding

All IBR pipes with red color at the ends

17 / 45 QMCC | 26.06.2013
Finished Pipe – Visual & Dimensional

OD Measurement
18 / 45 QMCC | 26.06.2013
Finished Pipe – Visual & Dimensional

Thickness Measurement
19 / 45 QMCC | 26.06.2013
Finished Pipe – Visual & Dimensional

Thickness Measurement
20 / 45 QMCC | 26.06.2013
Finished Pipe – Visual & Dimensional

Straightness Measurement
21 / 45 QMCC | 26.06.2013
Finished Pipe – Mechanical Testing

Transverse Tensile Test Specimen with identification

22 / 45 QMCC | 26.06.2013
Finished Pipe – Mechanical Testing

Measurement for
elongation
Tensile Test under progress
23 / 45 QMCC | 26.06.2013
Finished Pipe – Flattening Test

Flattening test sample with identification


24 / 45 QMCC | 26.06.2013
Finished Pipe – Bending Test

Bending Test sample after Bending


25 / 45 QMCC | 26.06.2013
Finished Pipe – Flaring Test

No observance of Cracks after flaring


26 / 45 QMCC | 26.06.2013
Finished Pipe – Hardness Test

Sample tested for its hardness


27 / 45 QMCC | 26.06.2013
Finished Pipe – Chemical Test

Heat wise Chemical analysis witnessed on the


samples collected from Pipe (product)
28 / 45 QMCC | 26.06.2013
Finished Pipe – Microstructure Test:

P91 Micro Structure test with 500x


29 / 45 QMCC | 26.06.2013
Finished Pipe – Non-Destructive Test

Where the nondestructive electric test is


performed, the lengths shall be marked
Online UT under with the letters “NDE.”

30 / 45
progress QMCC | 26.06.2013
Finished Pipe – Positive Material Identification

PMI Testing
31 / 45 QMCC | 26.06.2013
Finished Pipe – Hydro Test

Hydro Test Bench


32 / 45 QMCC | 26.06.2013
Finished Pipe – NDE/Hydro Test Marking

33 / 45 QMCC | 26.06.2013
Finished Pipe – Painting

All the pipes were painted with rust


preventive coating outside
34 / 45 QMCC | 26.06.2013
Finished Pipe

Vapor Corrosion Inhibitors (VCI) packets


35 / 45 QMCC | 26.06.2013
Finished Pipe – Packing

Placing of Endcap

36 / 45 QMCC | 26.06.2013
Non-Conformities Raised against Vendor

Some of the pipes already in production without raw


material inspection by L&T
37 / 45 QMCC | 26.06.2013
Non-Conformities Raised against Vendor

Pipe Inside Surface observed with uneven surface and a


depth up to 2 mm in some cases
38 / 45 QMCC | 26.06.2013
Non-Conformities Raised against Vendor

Surface observed with uneven grinding (Scratches like)


at some of the places on the below mentioned pipes
39 / 45 QMCC | 26.06.2013
Non-Conformities Raised against Vendor

Hardness not within the limits for the Grade 91.


Requirement 180 to 250 BHN
40 / 45 QMCC | 26.06.2013
Non-Conformities Raised against Vendor

With a step of up to 3 mm on Deep notch like with a


the outer surface depth more than 1 mm

140 MT of pipes (21 pipes) with a dimension of ID810x53; SA 335


P91 found with surface imperfections which are not acceptable.
All the pipes need to be reworked with grinding.
41 / 45 QMCC | 26.06.2013
Non-Conformities Raised against Vendor

Requirement: As per TDC (8900-BN05-02; Rev:00), Eddy Current Test (ET)


shall be carried out as per E309 with drill hole of 0.8 mm as well as
longitudinal or transverse notch (15% of thickness) on outside.

Actual: Vendor carried out ET only with different drilled hole sizes as per
A106.
42 / 45 QMCC | 26.06.2013
Inspection Findings

➢ Pipes found to be out of OD tolerance


➢ Pipes found to be out of tolerance with respect to
Straightness as per TDC requirement
➢ Pipes found heat number marking mistakes.

➢ Remedy:
➢ Mfg shall improve internal QC inspection to
reduce the unacceptable pipes with respect to
dimensions and marking

43 / 45 QMCC | 26.06.2013
Manufacturer Audit

44 / 45 QMCC | 26.06.2013
45 / 45 QMCC | 26.06.2013