You are on page 1of 13

LOAD CALCULATIONS

GROUND FLOOR LEVEL

DEAD LOADS
A.) Wall:
a. Concrete
 For Exterior Walls
Use Concrete Masonry Unit 150 mm THK
(with both face plastered full grout) = 3.45 kPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.45 𝑚2 ) (5.4𝑚) = 18.63 kN/m
_______________
Total Dead Load on Exterior Walls (Ground Floor) = 18.63 kN/m

 For Interior Walls


Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) = 3.32 kPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.32 𝑚2 ) (5.4𝑚) = 17.93 kN/m
_______________
Total Dead Load on Interior Walls (Ground Floor) = 17.93 kN/m

b. Comfort Room Walls


Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) and with
Ceramic Tile 200mm = 3.32 & 0.77 kPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑊𝑎𝑙𝑙 = (3.32 𝑚2 ) (5.4𝑚) = 17.93 kN/m
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑇𝑖𝑙𝑒𝑠 = (0.77 𝑚2 ) (2.0𝑚) = 1.54 kN/m
_______________
Total Dead Load on Comfort Room Walls (Ground Floor) = 19.47 kN/m

B.) Floor
b.1) Slab (Concrete)
Use Unit Weight = 24 kN/m3
Assumed Thickness of Slab = 200mm
Load of Slab = (24kN/𝑚3 )(0.200) = 4.80 kPa
____________
Total Dead Load on Slabs (Ground Floor) = 4.80 kPa
b.2) Finishes
 Use Ceramic or Quarry Tile (20cm) on 13mm mortar bed = 0.77
kPa
____
Total Dead Load on Finishes (Ground Floor) = 0.77 kPa

C.) Point Loads


a. Comfort Room Walls
Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) and with
Ceramic Tile 200mm = 3.32 & 0.77 kPa
𝐾𝑁
𝑃𝑜𝑖𝑛𝑡 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑊𝑎𝑙𝑙 = (3.32 ) (2.0𝑚)(1.7𝑚) = 11.288 kN
𝑚2
𝐾𝑁
𝑃𝑜𝑖𝑛𝑡 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑇𝑖𝑙𝑒𝑠 = (0.77 𝑚2 ) (1.5𝑚)(1.7m) = 1.9635 kN
____________
Total Point Load on Comfort Room Walls (Ground Floor) = 13.25 kN

LIVE LOADS
 Storage (Light) = 6.00 kPa
 Manufacturing (Light) = 6.00 kPa
 Office = 2.40 kPa
 Comfort Rooms = 2.40 kPa
 Lobbies and Ground Floor Corridors = 4.80 kPa
 Stairs & Exit Facility = 4.80 kPa

SEISMIC LOAD
= 20 kN (nodal load)
SECOND FLOOR LEVEL

DEAD LOADS
A.) Wall:
a. Concrete
 For Exterior Walls
Use Concrete Masonry Unit 150 mm THK
(with both face plastered full grout) = 3.45 KPa

𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.45 𝑚2 ) (3.5𝑚) = 12.08 kN/m
______________
Total Dead Load on Exterior Walls (Second Floor) = 12.08 kN/m

 For Interior Walls


Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) = 3.32 KPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.32 𝑚2 ) (3.5𝑚) = 11.62 kN/m
______________
Total Dead Load on Interior Walls (Second Floor) = 11.62 kN/m

b. Comfort Room Walls


Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) and with
Ceramic Tile 200mm = 3.32 & 0.77 kPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑊𝑎𝑙𝑙 = (3.32 𝑚2 ) (3.5𝑚) = 11.62 kN/m
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑇𝑖𝑙𝑒𝑠 = (0.77 𝑚2 ) (2.0𝑚) = 1.54 kN/m
_______________
Total Dead Load on Comfort Room Walls (Second Floor) = 13.16 kN/m

B.) Floor
b.1) Slab (Concrete)
Use Unit Weight = 24 kN/m3
Assumed Thickness of Slab = 200mm
Load of Slab = (24kN/𝑚3 )(0.200) = 4.80 kPa
____________
Total Dead Load on Slabs (Second Floor) = 4.80 kPa

b.2) Finishes
 Use Ceramic or Quarry Tile (20cm) on 13mm mortar bed= 0.77
kPa
____
Total Dead Load on Finishes (Second Floor) = 0.77 kPa

C.) Ceiling
 Gypsum Board = 0.10 kPa
 Suspended Steel Channel System = 0.10 kPa
 Lighting Fixtures and miscellaneous allowance = 0.10 kPa
____________
Total Dead Load on Finishes (Second Floor) = 0.30 kPa

D.) Point Loads


a. Comfort Room Walls
Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) and with
Ceramic Tile 200mm = 3.32 & 0.77
𝐾𝑁
kPa 𝑃𝑜𝑖𝑛𝑡 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑊𝑎𝑙𝑙 = (3.32 𝑚2 ) (2.0𝑚)(1.7𝑚) = 11.288 kN
𝐾𝑁
𝑃𝑜𝑖𝑛𝑡 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑇𝑖𝑙𝑒𝑠 = (0.77 𝑚2 ) (1.5𝑚)(1.7m) = 1.9635 kN
_______________
Total Point Load on Comfort Room Walls (Second Floor) = 13.25 kN

LIVE LOADS
 Storage (Light) = 6.00 kPa
 Manufacturing (Light) = 6.00 kPa
 Office = 2.40 kPa
 Comfort Rooms = 2.40 kPa
 Lobby = 4.80 kPa
 Corridors Above Ground Floor = 3.80 kPa
 Stairs & Exit Facility = 4.80 kPa

SEISMIC LOAD
= 20 kN (nodal load)

WIND LOAD
From NSCP 2010 Section 207.4.2.1
For the horizontal pressures, Ps is the combination of the windward
and leeward net pressures, Ps, shall be determined by the following
equation:
Ps= λKztIwPs9
Where:
 Height and Exposure adjustment ( λ )

(Reference: NSCP 2010 Figures 207.2A and 207-3)


Mean Roof Height,(h)= 16.5𝑚
Mean Roof Height, (h) = 16.5m, Under Category B
Interpolating values:
16.8 − 15.2 1.19 − 1.16
=
16.5 − 15.2 𝜆 − 1.16
𝜆 = 1.184375
 Topographic Factor (Kzt = 1.0)

(Reference: NSCP 2010 Section 207.5.7)


 Importance Factor (Iw = 1.0)
For Standard Occupancy Structure
(Reference: NSCP 2010 Section 207.5.6, Table 207-3, Importance
Factor)
 Simplified design wind pressure for exposure and height ≤ 18𝑚.
P𝑠 9 = 0.55
(Reference: NSCP 2010 Figure 207-3(a), Components and
Cladding Method 1)
Substituting values
𝑃𝑠 = (1.184375)(1.0)(1.0)(0.55)
𝑃𝑠 = 0.6514 𝐾𝑃𝑎
FOR THE UNIFORMLY DISTRIBUTED LOAD
 Second Floor

𝑾𝒖 = (𝟎. 𝟔𝟓𝟏𝟒)(𝟒. 𝟒𝟓𝒎) = 𝟐. 𝟗𝟎 𝒌𝑵/𝒎


THIRD FLOOR LEVEL

DEAD LOADS
A.) Wall:
a. Concrete
 For Exterior Walls
Use Concrete Masonry Unit 150 mm THK
(with both face plastered full grout) = 3.45 KPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.45 𝑚2 ) (3.5𝑚) = 12.08 kN/m
______________
Total Dead Load on Exterior Walls (Third Floor) = 12.08 kN/m

 For Interior Walls


Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) = 3.32 KPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.32 ) (3.5𝑚) = 11.62 kN/m
𝑚2
______________
Total Dead Load on Interior Walls (Third Floor) = 11.62 kN/m

b. Comfort Room Walls


Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) and with
Ceramic Tile 200mm = 3.32 & 0.77 kPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑊𝑎𝑙𝑙 = (3.32 𝑚2 ) (3.5𝑚) = 11.62 kN/m
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑇𝑖𝑙𝑒𝑠 = (0.77 𝑚2 ) (2.0𝑚) = 1.54 kN/m
_______________
Total Dead Load on Comfort Room Walls (Third Floor) = 13.16 kN/m

B.) Floor
b.1) Slab (Concrete)
Use Unit Weight = 24 kN/m3
Assumed Thickness of Slab = 200mm
Load of Slab = (24kN/𝑚3 )(0.200) = 4.80 kPa
____________
Total Dead Load on Slabs (Third Floor) = 4.80 kPa

b.2) Finishes
 Use Ceramic or Quarry Tile (20cm) on 13mm mortar bed=0.77 kPa

Total Dead Load on Finishes (Third Floor) = 0.77 kPa


C.) Ceiling
 Gypsum Board = 0.10 kPa
 Suspended Steel Channel System = 0.10 kPa
 Lighting Fixtures and miscellaneous allowance = 0.10 kPa
____________
Total Dead Load on Finishes (Third Floor) = 0.30 kPa

D.) Point Loads


a. Comfort Room Walls
Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) and with
Ceramic Tile 200mm = 3.32 & 0.77 kPa
𝐾𝑁
𝑃𝑜𝑖𝑛𝑡 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑊𝑎𝑙𝑙 = (3.32 𝑚2 ) (2.0𝑚)(1.7𝑚) = 11.288 kN
𝐾𝑁
𝑃𝑜𝑖𝑛𝑡 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑇𝑖𝑙𝑒𝑠 = (0.77 𝑚2 ) (1.5𝑚)(1.7m) = 1.9635 kN

Total Point Load on Comfort Room Walls (Third Floor) = 13.25 kN

LIVE LOADS
 Storage (Light) = 6.00 kPa
 Manufacturing (Light) = 6.00 kPa
 Office = 2.40 kPa
 Comfort Rooms = 2.40 kPa
 Lobby = 4.80 kPa
 Corridors Above Ground Floor = 3.80 kPa
 Stairs & Exit Facility = 4.80 kPa

SEISMIC LOAD
= 20 kN (nodal load)

WIND LOAD
From NSCP 2010 Section 207.4.2.1
For the horizontal pressures, Ps is the combination of the windward
and leeward net pressures, Ps, shall be determined by the following
equation:
Ps= λKztIwPs9
Where:
 Height and Exposure adjustment ( λ )

(Reference: NSCP 2010 Figures 207.2A and 207-3)


Mean Roof Height,(h)= 16.5𝑚
Mean Roof Height, (h) = 16.5m, Under Category B
Interpolating values:
16.8 − 15.2 1.19 − 1.16
=
16.5 − 15.2 𝜆 − 1.16
𝜆 = 1.184375

 Topographic Factor (Kzt = 1.0)

(Reference: NSCP 2010 Section 207.5.7)


 Importance Factor (Iw = 1.0)
For Standard Occupancy Structure
(Reference: NSCP 2010 Section 207.5.6, Table 207-3, Importance
Factor)
 Simplified design wind pressure for exposure and height ≤ 18𝑚.
P𝑠 9 = 0.55
(Reference: NSCP 2010 Figure 207-3(a), Components and
Cladding Method 1)
Substituting values
𝑃𝑠 = (1.184375)(1.0)(1.0)(0.55)
𝑃𝑠 = 0.6514 𝐾𝑃𝑎
FOR THE UNIFORMLY DISTRIBUTED LOAD
 Third Floor
𝒌𝑵
𝑾𝒖 = (𝟎. 𝟔𝟓𝟏𝟒 𝒎𝟐 ) (𝟑. 𝟓 𝒎) = 𝟐. 𝟐𝟖 𝒌𝑵/𝒎
FOURTH FLOOR LEVEL

DEAD LOADS
A.) Wall:
a. Concrete
 For Exterior Walls
Use Concrete Masonry Unit 150 mm THK
(with both face plastered full grout) = 3.45 KPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.45 𝑚2 ) (3.5𝑚) = 12.08 kN/m
______________
Total Dead Load on Exterior Walls (Fourth Floor) = 12.08 kN/m

 For Interior Walls


Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) = 3.32 KPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.32 𝑚2 ) (3.5𝑚) = 11.62 kN/m
______________
Total Dead Load on Interior Walls (Fourth Floor) = 11.62 kN/m

b. Comfort Room Walls


Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) and with
Ceramic Tile 200mm = 3.32 & 0.77 kPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑊𝑎𝑙𝑙 = (3.32 𝑚2 ) (3.5𝑚) = 11.62 kN/m
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑇𝑖𝑙𝑒𝑠 = (0.77 𝑚2 ) (2.0𝑚) = 1.54 kN/m
_______________
Total Dead Load on Comfort Room Walls (Fourth Floor) = 13.16 kN/m

B.) Floor
b.1) Slab (Concrete)
Use Unit Weight = 24 kN/m3
Assumed Thickness of Slab = 200mm
Load of Slab = (24kN/𝑚3 )(0.200) = 4.80 kPa
____________
Total Dead Load on Slabs (Fourth Floor) = 4.80 kPa

b.2) Finishes
 Use Ceramic or Quarry Tile (20cm) on 13mm mortar bed= 0.77
kPa
Total Dead Load on Finishes (Fourth Floor) = 0.77 kPa

C.) Ceiling
 Gypsum Board = 0.10 kPa
 Suspended Steel Channel System = 0.10 kPa
 Lighting Fixtures and miscellaneous allowance = 0.10 kPa
____________
Total Dead Load on Finishes (Fourth Floor) = 0.30 kPa

D.) Point Loads


a. Comfort Room Walls
Use Concrete Masonry Unit 100 mm THK
(with both face plastered full grout) and with
Ceramic Tile 200mm = 3.32 & 0.77 kPa
𝐾𝑁
𝑃𝑜𝑖𝑛𝑡 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑊𝑎𝑙𝑙 = (3.32 𝑚2 ) (2.0𝑚)(1.7𝑚) = 11.288 kN
𝐾𝑁
𝑃𝑜𝑖𝑛𝑡 𝐿𝑜𝑎𝑑 𝑜𝑓 𝑇𝑖𝑙𝑒𝑠 = (0.77 𝑚2 ) (1.5𝑚)(1.7m) = 1.9635 kN

Total Point Load on Comfort Room Walls (Fourth Floor) = 13.25 kN

LIVE LOADS
 Storage (Light) = 6.00 kPa
 Manufacturing (Light) = 6.00 kPa
 Office = 2.40 kPa
 Comfort Rooms = 2.40 kPa
 Lobby = 4.80 kPa
 Corridors Above Ground Floor = 3.80 kPa
 Stairs & Exit Facility = 4.80 kPa

SEISMIC LOAD
= 20 kN (nodal load)

WIND LOAD
From NSCP 2010 Section 207.4.2.1
For the horizontal pressures, Ps is the combination of the windward
and leeward net pressures, Ps, shall be determined by the following
equation:
Ps= λKztIwPs9

Where:
 Height and Exposure adjustment ( λ )

(Reference: NSCP 2010 Figures 207.2A and 207-3)


Mean Roof Height,(h)= 16.5𝑚
Mean Roof Height, (h) = 16.5m, Under Category B
Interpolating values:
16.8 − 15.2 1.19 − 1.16
=
16.5 − 15.2 𝜆 − 1.16
𝜆 = 1.184375
 Topographic Factor (Kzt = 1.0)

(Reference: NSCP 2010 Section 207.5.7)


 Importance Factor (Iw = 1.0)
For Standard Occupancy Structure
(Reference: NSCP 2010 Section 207.5.6, Table 207-3, Importance
Factor)
 Simplified design wind pressure for exposure and height ≤ 18𝑚.
P𝑠 9 = 0.55
(Reference: NSCP 2010 Figure 207-3(a), Components and
Cladding Method 1)
Substituting values
𝑃𝑠 = (1.184375)(1.0)(1.0)(0.55)
𝑃𝑠 = 0.6514 𝐾𝑃𝑎
FOR THE UNIFORMLY DISTRIBUTED LOAD
 Fourth Floor
𝒌𝑵
𝑾𝒖 = (𝟎. 𝟔𝟓𝟏𝟒 ) (𝟑. 𝟓 𝒎) = 𝟐. 𝟐𝟖 𝒌𝑵/𝒎
𝒎𝟐
ROOF BEAM LEVEL

ROOF DEAD LOADS


 Gypsum Board = 0.10 kPa
 Suspended Steel Channel System = 0.10 kPa
 Lighting Fixtures = 0.10 kPa

Total Dead Load on Roof Beam = 0.30 kPa

Self Weight
Use Unit Weight = 24 kN/m3
Roof Beam Self Weight = (24 kN/m3) (300mm) (450mm) = 3.24 kN/m

Total Self Weight for Room Beams = 3.24 kN/m

SEISMIC LOAD:
= 20 kN (nodal load)

WIND LOAD
From NSCP 2010 Section 207.4.2.1
For the horizontal pressures, Ps is the combination of the windward
and leeward net pressures, Ps, shall be determined by the following
equation:
Ps= λKztIwPs9

Where:
 Height and Exposure adjustment ( λ )

(Reference: NSCP 2010 Figures 207.2A and 207-3)


Mean Roof Height,(h)= 16.5𝑚
Mean Roof Height, (h) = 16.5m, Under Category B
Interpolating values:
16.8 − 15.2 1.19 − 1.16
=
16.5 − 15.2 𝜆 − 1.16
𝜆 = 1.184375
 Topographic Factor (Kzt = 1.0)

(Reference: NSCP 2010 Section 207.5.7)


 Importance Factor (Iw = 1.0)
For Standard Occupancy Structure
(Reference: NSCP 2010 Section 207.5.6, Table 207-3, Importance
Factor)
 Simplified design wind pressure for exposure and height ≤ 18𝑚.
P𝑠 9 = 0.55
(Reference: NSCP 2010 Figure 207-3(a), Components and
Cladding Method 1)
Substituting values
𝑃𝑠 = (1.184375)(1.0)(1.0)(0.55)
𝑃𝑠 = 0.6514 𝐾𝑃𝑎
FOR THE UNIFORMLY DISTRIBUTED LOAD
 Roof Deck
𝑊𝒖 = (𝟎. 𝟔𝟓𝟏𝟒 𝒌𝑵/𝒎𝟐 )(𝟏. 𝟕𝟓 𝒎) = 𝟏. 𝟏𝟒𝒌𝑵/𝒎

You might also like