Professional Documents
Culture Documents
DEAD LOADS
A.) Wall:
a. Concrete
For Exterior Walls
Use Concrete Masonry Unit 150 mm THK
(with both face plastered full grout) = 3.45 kPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.45 𝑚2 ) (5.4𝑚) = 18.63 kN/m
_______________
Total Dead Load on Exterior Walls (Ground Floor) = 18.63 kN/m
B.) Floor
b.1) Slab (Concrete)
Use Unit Weight = 24 kN/m3
Assumed Thickness of Slab = 200mm
Load of Slab = (24kN/𝑚3 )(0.200) = 4.80 kPa
____________
Total Dead Load on Slabs (Ground Floor) = 4.80 kPa
b.2) Finishes
Use Ceramic or Quarry Tile (20cm) on 13mm mortar bed = 0.77
kPa
____
Total Dead Load on Finishes (Ground Floor) = 0.77 kPa
LIVE LOADS
Storage (Light) = 6.00 kPa
Manufacturing (Light) = 6.00 kPa
Office = 2.40 kPa
Comfort Rooms = 2.40 kPa
Lobbies and Ground Floor Corridors = 4.80 kPa
Stairs & Exit Facility = 4.80 kPa
SEISMIC LOAD
= 20 kN (nodal load)
SECOND FLOOR LEVEL
DEAD LOADS
A.) Wall:
a. Concrete
For Exterior Walls
Use Concrete Masonry Unit 150 mm THK
(with both face plastered full grout) = 3.45 KPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.45 𝑚2 ) (3.5𝑚) = 12.08 kN/m
______________
Total Dead Load on Exterior Walls (Second Floor) = 12.08 kN/m
B.) Floor
b.1) Slab (Concrete)
Use Unit Weight = 24 kN/m3
Assumed Thickness of Slab = 200mm
Load of Slab = (24kN/𝑚3 )(0.200) = 4.80 kPa
____________
Total Dead Load on Slabs (Second Floor) = 4.80 kPa
b.2) Finishes
Use Ceramic or Quarry Tile (20cm) on 13mm mortar bed= 0.77
kPa
____
Total Dead Load on Finishes (Second Floor) = 0.77 kPa
C.) Ceiling
Gypsum Board = 0.10 kPa
Suspended Steel Channel System = 0.10 kPa
Lighting Fixtures and miscellaneous allowance = 0.10 kPa
____________
Total Dead Load on Finishes (Second Floor) = 0.30 kPa
LIVE LOADS
Storage (Light) = 6.00 kPa
Manufacturing (Light) = 6.00 kPa
Office = 2.40 kPa
Comfort Rooms = 2.40 kPa
Lobby = 4.80 kPa
Corridors Above Ground Floor = 3.80 kPa
Stairs & Exit Facility = 4.80 kPa
SEISMIC LOAD
= 20 kN (nodal load)
WIND LOAD
From NSCP 2010 Section 207.4.2.1
For the horizontal pressures, Ps is the combination of the windward
and leeward net pressures, Ps, shall be determined by the following
equation:
Ps= λKztIwPs9
Where:
Height and Exposure adjustment ( λ )
DEAD LOADS
A.) Wall:
a. Concrete
For Exterior Walls
Use Concrete Masonry Unit 150 mm THK
(with both face plastered full grout) = 3.45 KPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.45 𝑚2 ) (3.5𝑚) = 12.08 kN/m
______________
Total Dead Load on Exterior Walls (Third Floor) = 12.08 kN/m
B.) Floor
b.1) Slab (Concrete)
Use Unit Weight = 24 kN/m3
Assumed Thickness of Slab = 200mm
Load of Slab = (24kN/𝑚3 )(0.200) = 4.80 kPa
____________
Total Dead Load on Slabs (Third Floor) = 4.80 kPa
b.2) Finishes
Use Ceramic or Quarry Tile (20cm) on 13mm mortar bed=0.77 kPa
LIVE LOADS
Storage (Light) = 6.00 kPa
Manufacturing (Light) = 6.00 kPa
Office = 2.40 kPa
Comfort Rooms = 2.40 kPa
Lobby = 4.80 kPa
Corridors Above Ground Floor = 3.80 kPa
Stairs & Exit Facility = 4.80 kPa
SEISMIC LOAD
= 20 kN (nodal load)
WIND LOAD
From NSCP 2010 Section 207.4.2.1
For the horizontal pressures, Ps is the combination of the windward
and leeward net pressures, Ps, shall be determined by the following
equation:
Ps= λKztIwPs9
Where:
Height and Exposure adjustment ( λ )
DEAD LOADS
A.) Wall:
a. Concrete
For Exterior Walls
Use Concrete Masonry Unit 150 mm THK
(with both face plastered full grout) = 3.45 KPa
𝐾𝑁
𝑈𝑛𝑖𝑓𝑜𝑟𝑚 𝐷𝑖𝑠𝑡𝑟𝑖𝑏𝑢𝑡𝑒𝑑 𝐿𝑜𝑎𝑑 = (3.45 𝑚2 ) (3.5𝑚) = 12.08 kN/m
______________
Total Dead Load on Exterior Walls (Fourth Floor) = 12.08 kN/m
B.) Floor
b.1) Slab (Concrete)
Use Unit Weight = 24 kN/m3
Assumed Thickness of Slab = 200mm
Load of Slab = (24kN/𝑚3 )(0.200) = 4.80 kPa
____________
Total Dead Load on Slabs (Fourth Floor) = 4.80 kPa
b.2) Finishes
Use Ceramic or Quarry Tile (20cm) on 13mm mortar bed= 0.77
kPa
Total Dead Load on Finishes (Fourth Floor) = 0.77 kPa
C.) Ceiling
Gypsum Board = 0.10 kPa
Suspended Steel Channel System = 0.10 kPa
Lighting Fixtures and miscellaneous allowance = 0.10 kPa
____________
Total Dead Load on Finishes (Fourth Floor) = 0.30 kPa
LIVE LOADS
Storage (Light) = 6.00 kPa
Manufacturing (Light) = 6.00 kPa
Office = 2.40 kPa
Comfort Rooms = 2.40 kPa
Lobby = 4.80 kPa
Corridors Above Ground Floor = 3.80 kPa
Stairs & Exit Facility = 4.80 kPa
SEISMIC LOAD
= 20 kN (nodal load)
WIND LOAD
From NSCP 2010 Section 207.4.2.1
For the horizontal pressures, Ps is the combination of the windward
and leeward net pressures, Ps, shall be determined by the following
equation:
Ps= λKztIwPs9
Where:
Height and Exposure adjustment ( λ )
Self Weight
Use Unit Weight = 24 kN/m3
Roof Beam Self Weight = (24 kN/m3) (300mm) (450mm) = 3.24 kN/m
SEISMIC LOAD:
= 20 kN (nodal load)
WIND LOAD
From NSCP 2010 Section 207.4.2.1
For the horizontal pressures, Ps is the combination of the windward
and leeward net pressures, Ps, shall be determined by the following
equation:
Ps= λKztIwPs9
Where:
Height and Exposure adjustment ( λ )