You are on page 1of 3

Appendix B1: Tolerances of the precast elements

1 Tolerances of Hollow core slabs:

`
Parameter Tolerances (As per
Annexure 1)
Thickness ( C ) + 6mm
Length + 13mm
Width: Full Slabbottom (b) + 6mm
Width: Full Slab top (bb) 1150+ 6mm
Width: Part slab (bottom) + 6mm
Cut-out Placement + 50mm
Cut-out Size + 13mm
Appendix B1: Tolerances of the precast elements
2 Load bearing walls/Non load bearing walls

Tolerances (As per


Parameter
Annexure 1)
Height (Longer side) + 13 mm
Width + 6 mm
Thickness + 6 mm
Size of grouting holes or cut-outs + 13 mm
Placement of grouting holes or + 25 mm
cut-outs
Placement of grouting bars + 13 mm
Placement of anchors, lifting + 25 mm
parts etc. (embedment)
Doors and window cut-outs
Height + 13 mm
Width + 13 mm
Location + 13 mm
Difference in diagonals for skew + 6 mm

3 Footings

Tolerances (As per


Parameter
Annexure 1)
Height + 13 mm
Width + 6 mm
Thickness + 6 mm
Size of grouting holes
Location of grouting holes + 13 mm
Location of grouting bars + 13 mm
Placement of anchors, lifting
+ 25 mm
parts etc (embedment).
Appendix B1: Tolerances of the precast elements
4 Boundary wall panels

Parameter Tolerances (As per


Annexure 1)
Height + 13 mm
Width + 6 mm
Thickness + 6 mm
Placement of anchors, lifting + 25 mm
parts etc. (embedment)

5 Stair cases

Parameter Tolerances (As per


Annexure 1)
Length + 13 mm
Width + 10 mm
Individual step width (tread) + 6 mm
Depth (Thickness) + 6 mm
Individual riser + 5 mm
Location of inserts for structural + 10 mm
connections
Location of embedment + 25 mm

6 Chajjas

Parameter Tolerances (As per


Annexure 1)
Length + 13 mm
Width + 10 mm
Thickness + 6 mm

***************************

You might also like