Lineup of DC Inverter Air Conditioners with R-32 Refrigerant

Daikin is the sole manufacturer to produce both air conditioning equipment and refrigerants worldwide. Our cutting-edge technologies and use
of advanced R-32 refrigerant provide enhanced comfort while reducing the impact on climate change.

Product name 2.5 kW Class 3.5 kW Class 5.0 kW Class 6.0 kW Class 7.1 kW Class

Urusara 7
Heat Pump

FTXZ25NVMV FTXZ35NVMV FTXZ50NVMV

FTKJ and
FTXJ Series
FTKJ25NVMVW (white) and FTKJ35NVMVW (white) and FTKJ50NVMVW (white) and
Cooling Only FTXJ25NVMVW (white) FTXJ35NVMVW (white) FTXJ50NVMVW (white)

Heat Pump

FTKJ25NVMVS (silver) and FTKJ35NVMVS (silver) and FTKJ50NVMVS (silver) and


FTXJ25NVMVS (silver) FTXJ35NVMVS (silver) FTXJ50NVMVS (silver)

FTKM Series
Cooling Only

FTKM25SVMV FTKM35SVMV FTKM50SVMV FTKM60SVMV FTKM71SVMV

FTXV Series
Heat Pump

FTXV25QVMV FTXV35QVMV FTXV50QVMV FTXV60QVMV FTXV71QVMV

FTKC and
ATKC Series Cooling Only

FTKC25TVMV and ATKC25TVMV FTKC35TVMV and ATKC35TVMV FTKC50TVMV FTKC60TVMV FTKC71TVMV


FTKC25TAVMV and ATKC25TAVMV FTKC35TAVMV and ATKC35TAVMV

FTHF Series
Heat Pump

FTHF25RVMV FTHF35RVMV FTHF50RVMV FTHF60RVMV FTHF71RVMV

FTKQ Series
Cooling Only

FTKQ25SVMV FTKQ35SVMV FTKQ50SVMV FTKQ60SVMV


FTKQ25SAVMV FTKQ35SAVMV

1 2
Urusara 7

A New Kind of Cool


Urusara 7 puts the latest Japanese air conditioning technology at your fingertips, offering a
unique, total comfort experience for any lifestyle. Powerful year-round cooling and dehumidifying
are just the beginning.
Urusara 7 is also the world’s first air conditioner to use next-generation R-32 refrigerant1.
Along with its many energy-saving features, this higher performance refrigerant gives Urusara 7
unrivalled energy efficiency2.

Features
• Redesigned air intake and heat exchanger
• World-first 3 humidity control technology
• Precision circulation airflow
• Reliable streamer discharge air purification
• Convenient automatic filter cleaning system
• Innovative design with Japanese aesthetic
• Remote control via smartphone (optional adaptor)

Category: Product Design 2013

Notes: 1. For residential-use wall-mounted type air conditioners as of November 2012, when Daikin launched Urusara 7 in the Japanese market.
2. In January 2013, the 4.0 to 7.1 kW class models for the Japanese market received the Minister’s Prize from Japan’s Ministry of
Economy, Trade and Industry in the Fiscal 2012 Grand Prizes for Excellence in Energy Efficiency and Conservation.
3. For residential-use air conditioners as of 1999, when Daikin launched Ururu Sarara in the Japanese market.

3 4
FTKJ and FTXJ Series

Form. Function. Design.


The sleek Europiean style of FTKJ and FTXJ series proves once again that design is everything.
Yet this elegant body also houses cutting-edge smart technology which provides outstanding
comfort and performance in any situation.
The series also delivers Daikin's well-known energy efficiency, thanks to features such as its
redesigned swing compressors. This versatile series truly is a total solution for designers,
architects and home-owners alike.

Features
• Energy saving COPs of 3.59 to 4.81 for the FTKJ series
• Stylish finish in eye-pleasing colours
• Wide selection of comfort technologies
• Whisper quiet sound levels
• Remote control via smartphone (optional adaptor)

White Silver

Category: Product Design 2014

5 6
Urusara 7 FTXJ Series
Heat Pump Heat Pump
FTXZ25/35/50 FTXJ25/35/50 (white) FTXJ25/35/50 (silver)

Model name Indoor unit FTXZ25 FTXZ35 FTXZ50 Model name FTXJ25 (white) FTXJ35 (white) FTXJ50 (white)
Indoor unit
Outdoor unit RXZ25 RXZ35 RXZ50 FTXJ25 (silver) FTXJ35 (silver) FTXJ50 (silver)

kW 2.45 (0.6-3.9) 3.45 (0.6-5.3) 4.95 (0.6-5.8) Outdoor unit RXJ25 RXJ35 RXJ50
Rated
Cooling
(Min.-Max.) kW 2.45(0.9-3.3)
2.5 (0.6-3.9) 3.45 (0.6-5.3)
3.5 (0.9-4.1) 4.95 (0.6-5.8)
5.0 (1.4-5.5)
Btu/h 8,400 (2,000-13,300) 11,800 (2,000-18,100) 16,900 (2,000-19,800) Rated
Cooling
Capacity (Min.-Max.)
Btu/h 8,500 (3,100-11,300) 11,900 (3,100-14,000) 17,100 (4,800-18,800)
kW 3.6 (0.6-7.5) 5.0 (0.6-9.0) 6.3 (0.6-9.4)
Rated Capacity
Heating (Min.-Max.)
Btu/h 12,300 (2,000-25,600) 17,100 (2,000-30,700) 21,500 (2,000-32,100) kW 3.2 (0.9-4.7) 4.0 (0.9-5.1) 5.8 (1.1-7.0)
Rated
Heating (Min.-Max.)
Btu/h 10,900 (3,100-16,000) 13,600 (3,100-17,400) 19,800 (3,800-23,900)
Cooling 430 (110-880) 680 (110-1,330) 1,150 (110-1,600)
Rated
Power consumption W
(Min.-Max.) Cooling 540 920 1,470
Heating 620 (100-2,010) 1,000 (100-2,530) 1,410 (100-2,640) Rated
Power consumption W
(Min.-Max.)
Indoor unit FTXZ25 FTXZ35 FTXZ50 Heating 700 990 1,590

Dimensions (H × W × D) mm 295 × 798 × 370 Indoor unit FTXJ25 (white) FTXJ35 (white) FTXJ50 (white)

Outdoor unit RXZ25 RXZ35 RXZ50 FTXJ25 (silver) FTXJ35 (silver) FTXJ50 (silver)

mm Dimensions (H × W × D) mm 303 x 998 x 212


Dimensions (H × W × D) 595 × 795 × 300

See the Urusara 7 catalogue for details. Outdoor unit RXJ25 RXJ35 RXJ50

Dimensions (H × W × D) mm 550 x 765 x 285 735 x 825 x 300

See the FTKJ and FTXJ series catalogue for details.

FTKJ Series
Cooling Only
FTKJ25/35/50 (white) FTKJ25/35/50 (silver)

Model name FTKJ25 (white) FTKJ35 (white) FTKJ50 (white) Contents


Indoor unit
FTKJ25 (silver) FTKJ35 (silver) FTKJ50 (silver)
DC Inverter: Cutting-Edge Comfort P9 Choice of Wide Range of Airflow Patterns P27
Outdoor unit RKJ25 RKJ35 RKJ50
Inverter Air Conditioners Reduce Electricity Consumption P11 Energy Saving Functions P29
kW 2.5 (1.2-3.4)
2.45 (0.6-3.9) 3.5 (1.3-4.1)
3.45 (0.6-5.3) 5.2 (1.7-5.5)
4.95 (0.6-5.8)
Cooling capacity Rated (Min.-Max.)
Btu/h 8,500 (4,100-11,600) 11,900 (4,400-14,000) 17,700 (5,800-18,800) Coanda Panel Effectively Cools Even Large Rooms P13 Quiet Nights in Your Neighbourhood P31

Power consumption Rated W 520 855 1,450 FTKM Series P15 Easy to Keep Room Air Clean P33

Indoor unit FTKJ25 (white) FTKJ35 (white) FTKJ50 (white) FTXV Series P17 Remote Control via Smartphone P35
FTKJ25 (silver) FTKJ35 (silver) FTKJ50 (silver)
FTKC and ATKC Series P19 Function List P37
Dimensions (H × W × D) mm 303 x 998 x 212
FTHF Series P21 Functions P39
Outdoor unit RKJ25 RKJ35 RKJ50

Dimensions (H × W × D) mm 550 x 765 x 285 735 x 825 x 300 FTKQ Series P23 Wireless Remote Controller P41

See the FTKJ and FTXJ series catalogue for details.


Next-Generation R-32 Refrigerant P25 Specifications P45

Reuse of Existing Piping P26 Options P51

7 8
FTKM and FTXV Series
FTKC, ATKC and FTHF Series
FTKQ Series

DC Inverter: Cutting-Edge Comfort


Inverter air conditioners are well known for their precise control and outstanding energy efficiency, particularly
compared to non-inverter models. This precision also means superior comfort, plus full power at the touch of a button.
With our strong environmental concern, we are leading the promotion of inverter systems and next-generation
R-32 refrigerant worldwide. The FTKM series offers rapid cooling, humidity control and high durability even in areas
with unstable power supplies. You can now enjoy worry-free, cutting-edge comfort.

Features
• Inverter technology with high energy ratings
• Continuous humidity control using hybrid cooling
• Draftless airflow for rapid cooling of all rooms
• Two-Area Intelligent Eye with infrared sensor
• Outdoor unit unaffected by unstable power supplies
• Optional dust collection filter suitable for PM 2.5

FTKM Series Cooling Only FTXV Series Heat Pump

2.5 to 7.1 kW classes 2.5 to 7.1 kW classes

FTKC and ATKC Series Cooling Only FTHF Series Heat Pump

FTKC: 2.5 to 7.1 kW classes; ATKC: 2.5 and 3.5 kW classes 2.5 to 7.1 kW classes

FTKQ Series Cooling Only

2.5 to 6.0 kW classes

9 10
Inverter Air Conditioners Reduce Electricity Consumption

5 Star Rating for All Models No Starting and Stopping


The FTKM series achieves CSPFs of 5.87 to Models CSPF Inverter air conditioners vary their capacity by adjusting Rotations
7.40 thanks to Daikin’s DC Inverter control and FTKM25SVMV 7.40 the rotation speed of their compressors. In contrast, Controls rotation according
next-generation R-32 refrigerant. The FTKM series, non-inverter models have a fixed capacity and can only to required power
and all other Daikin series, have earned Vietnam's FTKM35SVMV 6.53 control the room temperature by starting or stopping Inverter Large loss of electricity
highest 5 star energy efficiency rating. their compressors.
Dummy FTKM50SVMV 6.73 Non-inverter

FTKM60SVMV 6.21

FTKM71SVMV 5.87
Time

What Is CSPF? CSPF (cooling seasonal performance factor) is the annual operating efficiency of an air conditioner

Powerful and Energy Saving


under conditions close to the actual conditions for specific applications (buildings, etc.) and
operating periods.

Total capacity during cooling (kWh)


CSPF =
Total power consumption during cooling (kWh) Inverter models operate at maximum capacity (100% load) to FTKM50SVMV
It represents the integral cooling capacity per kilowatt hour of power consumption for an air
quickly reach the set temperature. They then reduce operation Maximum capacity
conditioner that operates under fixed conditions throughout the year. to low capacity (partial load), which is sufficient to maintain Capacity 6.2 kW
the set temperature. This allows inverter models to reach the
set temperature more quickly and operate at low capacity
(partial load) most of the time.

Lower Electricity Consumption


Minimum capacity
1.2 kW

Inverters are devices that are able to vary their capacity by adjusting operating
Auto SL L M H
frequency. This allows inverter air conditioners to cut electricity use compared
to non-inverter models. An inverter system can help to noticeably reduce Time

household power bills. Fan


speed
Low High
If you select Auto Fan Speed, your inverter air conditioner will operate at
maximum efficiency without any further setting. It will not start and stop its compressor to maintain the room Constant Comfort
temperature. You can also go out of the room for a short time without any worries.
Inverter models finely adjust their capacity according to the heat load, minimising the difference between the set temperature and
FTKM50SVMV room temperature. This ensures higher comfort levels than with non-inverter models. With the FTXV series, the set temperature can
be changed in 0.5°C steps. This precise control allows you to finely adjust the temperature to suit your personal comfort level.
Maximum capacity
Temperature fluctuation during cooling operation
6.2 kW Medium capacity Temp.

Small temp. Not cool


High compressor rotation speed
100% load 3.7 kW Minimum capacity
difference
Medium compressor rotation speed 1.2 kW Non-inverter
Slow compressor rotation speed
Partial load
Partial load Comfortable

Set temp. Inverter

Too cool
Starts Time

11 12
Coanda Panel Effectively Cools Even Large Rooms

Draftless Airflow Inverter Powerful Operation


Inverter Powerful Operation boosts airflow to maximum volume for a 20
minutes
20 minute period. This function is convenient for quickly adjusting

10 Metr the indoor temperature to the set temperature. After 20 minutes, the
e s Airflow Length1 unit automatically returns to its previous settings.

Low/High Voltage Shield


Unstable power supply is a common problem in many parts of the world. It is well known for causing overvoltage, which can seriously
damage electronic devices. However, it also causes undervoltage, which can shut down your air conditioner just when you need it most.
Daikin’s printed circuit boards are specially
strengthened to withstand voltage fluctuations. Handles from
The Coanda panel’s new shape creates airflow along the ceiling. This allows the air to spread out across the This allows them to operate across a wide range 130 V to 440 V Max.
whole room without creating uncomfortable drafts. The entire area is wrapped in a large elliptical flow of voltages in areas with unstable power. FTKM 440 V
which circulates efficiently, helping to cool quickly and evenly. series units operate at 130 to 264 V and can
withstand zero to 440 V.
The Coanda panel is available for the FTKM, FTKC, ATKC and FTHF series.
This function is available for the FTKM and FTKQ series.The FTKQ
series can continue operation from 150 to 264 V. 130 V
Low temperature fluctuations

When the voltage is higher or lower than the operable range, the air conditioning system switches itself off.
When the voltage is adjusted back to its original value, the system automatically starts operating again.

Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins


Draftless Airflow rapidly achieves a uniform temperature in each corner of the room.
The outdoor unit’s heat exchanger fins are processed
Cross section of anti-corrosion treated fin
using a special anti-corrosion treatment. The surface
Hydrophilic film
When the spoon touches hes the water, is covered with a thin acrylic resin layer to provide
What Is the Coanda Panel? it tries to flow aloonng the
along t surface
th f enhanced resistance to acid rain and salt corrosion.
Aluminium
before dropping. g. Corrosion-resistant
The Coanda effect causes a stream of air or liquid to be attracted to acrylic resin
a nearby surface. A faucet and spoon provide a simple example. If
you turn on the faucet and let the spoon touch the water, it will try to
flow along the spoon’s inner curve.
The Coanda panel creates a similar effect. However, in this
case, the shape of the panel bends the airflow up along the flaps
towards the ceiling. This allows the air to be delivered much further
than with standard flaps. Heat exchanger fin

Note: 1. This value is based on an in-house simulation for the FTKM60 and 71 models. It is measured during cooling operation when using H-tap and Comfort Airflow Mode.
The actual distance which can be reached depends on the setting environment and operating conditions.
13 14
FTKM Series
Cooling Only

Control of Both Humidity and Temperature


Humans release body heat by evaporating moisture on our skin, meaning we feel cooler with lower humidity. With conventional
inverter systems, once the room temperature reaches the set temperature, operation decreases to low capacity (partial load).
However, this also reduces dehumidifying, making the air feel uncomfortable.
The FTKM series is equipped with a humidity sensor and Daikin's hybrid cooling technology. Together these features allow
FTKM units to automatically control humidity so you feel cool even during low capacity operation.
The hybrid cooling technology is automatically activated during cooling and dry operation.

Indoor Indoor
humidity of 50 %
30
humidity of 80 %
Indoor temperature of 25°C Indoor temperature of 25°C
28

Indoor temperature ˚C
26

24
Comfortable
22
2.5 kW Class Grade 5

FTKM25SVMV / RKM25SVMV 20

Cooling Capacity Rated (Min.-Max.) kW 2.5 (1.2-3.6) Dummy 30 40 50 60 70 80


Humidity %
FTKM25/35SVMV CSPF 7.40
3.5 kW Class Grade 5

FTKM35SVMV / RKM35SVMV Temp.: 25˚C Humidity: 50% Temp.: 25˚C Humidity: 80%

Dummy Humans release body heat by evaporating moisture on our


Cooling Capacity Rated (Min.-Max.) kW 3.5 (1.2-4.1)
skin, meaning we feel cooler with lower humidity. Daikin has
RKM25/35SVMV CSPF 6.53 used this knowledge to create a more comfortable balance
between temperature and humidity.
5.0 kW Class Grade 5
Comfortable Hot and humid
FTKM50SVMV / RKM50SVMV

Cooling Capacity Rated (Min.-Max.) kW 5.2 (1.2-6.2) Dummy

CSPF 6.73
FTKM50/60/71SVMV
6.0 kW Class Grade 5

FTKM60SVMV / RKM60SVMV Dust Collection Filter (PM2.5)1 (optional accessory)


Cooling Capacity Rated (Min.-Max.) kW 6.0 (1.2-7.1) Dummy
This filter removes PM 2.5, particulate matter which is smaller
CSPF 6.21 than 2.5 micrometres (µm). 1 µm is equal to 1/1,000 mm. PM 2.5
RKM50/60/71SVMV 7.1 kW Class Grade 5 is small enough to be breathed deep into the lungs. The filter can
FTKM71SVMV / RKM71SVMV not be cleaned and we recommend replacing it every six months.
Cooling Capacity Rated (Min.-Max.) kW 7.1 (1.2-8.2) Dummy

CSPF 5.87
Note: 1. This filter is not a medical device and it does not have any certification.
The effectiveness of the filter depends on the room conditions and usage of the air conditioner.

15 16
FTXV Series
Heat Pump

Two-Area Intelligent Eye (focus and comfort)


This function uses its infrared sensor to direct airflow either toward or away from people. Direct airflow may be more comfortable during
cooling operation while indirect airflow may be more convenient during heating operation.

Directs airflow away from people to prevent drafts

Area A Area A Area A


Area B Area B Area B

If a person is detected in area A, airflow is directed If a person is detected in area B, airflow is directed If people are detected in both area A and B, airflow is
toward area B. toward area A. directed toward area A.

2.5 kW Class Grade 5


Directs airflow toward people to increase cooling
FTXV25QVMV / RXV25QVMV
Cooling Capacity Rated (Min.-Max.) kW 2.5 (0.9-3.7)
Dummy
Heating Capacity Rated (Min.-Max.) kW 3.2 (0.9-5.3)
FTXV25/35QVMV Area A Area B Area A Area B
CSPF 6.21
3.5 kW Class Grade 5

FTXV35QVMV / RXV35QVMV
Cooling Capacity Rated (Min.-Max.) kW 3.5 (0.9-4.2)
Dummy
Heating Capacity Rated (Min.-Max.) kW 3.7 (0.9-5.3)
RXV25/35QVMV CSPF 6.24

If a person is detected in area A, airflow is directed If a person is detected in area B, airflow is directed
toward area A. toward area B.
5.0 kW Class Grade 5

FTXV50QVMV / RXV50QVMV
Cooling Capacity Rated (Min.-Max.) kW 5.0 (1.1-6.7)
Dummy
Heating Capacity Rated (Min.-Max.) kW 6.0 (1.0-8.0)

FTXV50/60/71QVMV
CSPF 6.35
Comfort Airflow Mode
6.0 kW Class Grade 5

FTXV60QVMV / RXV60QVMV
Comfort Airflow Mode prevents uncomfortable drafts from blowing
Cooling Capacity Rated (Min.-Max.) kW 6.0 (1.1-7.5)
Dummy directly on to a person’s body. During cooling operation, the flap
Heating Capacity Rated (Min.-Max.) kW 7.2 (1.0-8.6)
moves upwards to prevent cold drafts. During heating operation, the
CSPF 5.81
flap turns vertically downwards to drive warm air to the floor.
RXV50/60/71QVMV 7.1 kW Class Grade 5

FTXV71QVMV / RXV71QVMV
Cooling Capacity Rated (Min.-Max.) kW 7.1 (2.0-8.9)
Dummy
Heating Capacity Rated (Min.-Max.) kW 8.0 (2.0-10.6)
CSPF 4.65

17 18
FTKC and ATKC Series
Cooling Only

Draftless Airflow
The Coanda panel bends airflow along the ceiling while the unit takes in air at
both the top and bottom. This creates a circular flow which covers the entire room.
The whole area is cooled quickly and evenly without uncomfortable drafts.

Intelligent Eye (auto energy saving)


Intelligent Eye prevents energy wastage by using its infrared sensor to detect human
movement in a room. If there is no movement for 20 minutes, it automatically adjusts
the set temperature by approximately 2°C. Once Intelligent Eye is turned on, it
operates automatically without any further setting.
2.5 kW Class Grade 5
Intelligent Eye indicator Intelligent Eye sensor
FTKC25TVMV / RKC25TVMV ATKC25TVMV / ARKC25TVMV
FTKC25TAVMV / RKC25TAVMV ATKC25TAVMV / ARKC25TAVMV
Dummy Intelligent Eye
Cooling Capacity Rated (Min.-Max.) kW 2.5 (1.0-3.4)
For FTKC For ATKC
FTKC25/35TVMV ATKC25/35TVMV models models
CSPF 5.70
FTKC25/35TAVMV ATKC25/35TAVMV
3.5 kW Class Grade 5

FTKC35TVMV / RKC35TVMV ATKC35TVMV / ARKC35TVMV


FTKC35TAVMV / RKC35TAVMV ATKC35TAVMV / ARKC35TAVMV
Dummy
Cooling Capacity Rated (Min.-Max.) kW 3.5 (1.3-4.1)
RKC25/35TVMV ARKC25/35TVMV CSPF 5.65
RKC25/35TAVMV ARKC25/35TAVMV

If Intelligent Eye detects no movement for 20 minutes, When a person enters the room, it automatically
it adjusts the set temperature by approximately 2°C. returns the temperature to the set level.
5.0 kW Class Grade 5

FTKC50TVMV / RKC50TVMV

Cooling Capacity Rated (Min.-Max.) kW 5.2 (1.4-6.0) Dummy

CSPF 6.05
Easy to operate wireless remote controller
FTKC50/60/71TVMV
6.0 kW Class Grade 5

FTKC60TVMV / RKC60TVMV
All functions are located on the front surface of this wireless remote
controller for quick access. A luminous button makes it easy to stop
Cooling Capacity Rated (Min.-Max.) 6.0 (1.4-6.7) Dummy
kW
operation in the dark.
CSPF 5.82 The backlit LCD allows easy operation in the dark. This function
RKC50/60/71TVMV 7.1 kW Class Grade 5
is available for the FTKC series.
FTKC71TVMV / RKC71TVMV

Cooling Capacity Rated (Min.-Max.) kW 7.1 (2.1-7.5) Dummy The luminous off button is easy
to see in the dark.
The rounded controller is easy
CSPF 5.75 to operate.

19 20
FTHF Series
Heat Pump

Complete Comfort 365 Days a Year


If the ambient temperature falls below 15°C, you will probably feel cold without
some type of heating. Electric heaters are useful for spot heating. However, you
and your family are still likely to feel cold unless you stay near them.
Heat pump air conditioners can easily deliver warm air to every corner of a
room, making them much more effective. As well as heating, they also provide
cooling, dry and fan only operations for year-round comfort.

2.5 kW Class Grade 5

FTHF25RVMV / RHF25RVMV
Cooling Capacity Rated (Min.-Max.) kW 2.5 (1.0-3.4)
Dummy
Heating Capacity Rated (Min.-Max.) kW 2.5 (1.0-3.4)
FTHF25/35RVMV
CSPF

3.5 kW Class
6.00

Grade 5
Automatic Operation
FTHF35RVMV / RHF35RVMV
This function automatically selects heating or cooling mode based on the room temperature at startup. For example, if the set temperature
Cooling Capacity Rated (Min.-Max.) kW 3.5 (1.2-3.8)
Dummy
is 22°C but the room temperature is 13°C, the unit will begin heating. If the room temperature is 30°C, it will begin cooling.
Heating Capacity Rated (Min.-Max.) kW 3.5 (1.2-3.8)
RHF25/35RVMV
CSPF 5.30

Set temperature Room temperature Operation


5.0 kW Class Grade 5

FTHF50RVMV / RHF50RVMV 30°C Cooling operation


22°C
Cooling Capacity Rated (Min.-Max.) kW 5.0 (1.6-6.0)
Dummy 13°C Heating operation
Heating Capacity Rated (Min.-Max.) kW 5.0 (1.6-6.0)
CSPF 6.30
FTHF50/60/71RVMV
6.0 kW Class Grade 5

FTHF60RVMV / RHF60RVMV
Cooling Capacity Rated (Min.-Max.) kW 6.0 (1.6-6.7)
Dummy
Heating Capacity Rated (Min.-Max.) kW 6.0 (1.6-6.7)
CSPF 5.70
RHF50/60/71RVMV
7.1 kW Class Grade 5

FTHF71RVMV / RHF71RVMV
Cooling Capacity Rated (Min.-Max.) kW 7.1 (2.1-7.5)
Dummy
Heating Capacity Rated (Min.-Max.) kW 7.1 (2.1-7.5)
CSPF 5.50

21 22
FTKQ Series
Cooling Only

Compact Units Ideal for Limited Spaces


FTKQ series indoor units are only 770 mm Width
wide in all of the 2.5 to 6.0 kW classes.
Thanks to their compact design, they can 27%

285 mm
290 mm
smaller
even be installed in narrow spaces between
windows or above doors.
New model
770 mm
Previous model FTNE60MV1V
1,050 mm

Mould-Proof Air Filter


2.5 kW Class Grade 5

FTKQ25SVMV / RKQ25SVMV FTKQ25SAVMV / RKQ25SAVMV The air filter is impregnated with a mould preventative. The substance
Cooling Capacity Rated (Min.-Max.) kW 2.65 (1.0-2.9) Dummy stops any growth, increase in number or activity by mould on the
filter surface.
FTKQ25/35/50/60SVMV CSPF 4.50
FTKQ25/35SAVMV
3.5 kW Class Grade 5

FTKQ35SVMV / RKQ35SVMV FTKQ35SAVMV / RKQ35SAVMV


The air filter is coated with a mould preventative.
Cooling Capacity Rated (Min.-Max.) kW 3.50 (1.3-3.8) Dummy

CSPF 4.60
5.0 kW Class
Low/High Voltage Shield
Grade 5
RKQ25SVMV RKQ35SVMV RKQ50/60SVMV
FTKQ50SVMV / RKQ50SVMV
RKQ25SAVMV RKQ35SAVMV

Cooling Capacity Rated (Min.-Max.) kW 5.0 (1.4-5.4) Dummy


Unstable power supply is a common problem in many parts of the world. It is well known for causing overvoltage, which can seriously
CSPF 4.45 damage electronic devices. However, it also causes undervoltage, which can shut down your air conditioner just when you need it most.
6.0 kW Class Grade 5 Daikin’s printed circuit boards are specially strengthened to withstand voltage fluctuations. This allows them to operate across a wide
FTKQ60SVMV / RKQ60SVMV range of voltages in areas with unstable power. FTKQ series units operate at 150 to 264 V and can withstand zero to 440 V.
Dummy This function is available for the FTKM and FTKQ series. The FTKM series can continue operation from 130 to 264 V.
Cooling Capacity Rated (Min.-Max.) kW 6.0 (1.7-6.0)

CSPF 4.78

23 24
Next-Generation R-32 Refrigerant Reuse of Existing Piping

Replacement for R-22 Smooth Replacement of Air Conditioners


As the sole worldwide manufacturer of both air conditioning equipment and refrigerants, Daikin is continuously researching refrigerants as well You can reuse the existing piping when replacing a system that uses R-22 or R-410A
as new technologies which can reduce energy consumption. Use of refrigerants with a lower impact on global warming is urgently required as refrigerant with a new Daikin R-32 model. The piping can be changed over
climate change has become one of the most critical global issues. Daikin has now adopted R-32. This next-generation refrigerant does not without cleaning up to its maximum length. This allows a Daikin air conditioner
deplete the ozone layer and has a lower impact on global warming. using R-32 refrigerant to be installed smoothly even with built-in piping.

Notes for Installation


Zero Ozone Layer Depletion • Reuse depends on the oil stains that remain inside the existing refrigerant
piping. If the inside is extremely dirty, it is necessary to clean or replace the piping.
The ozone layer surrounds the Earth and helps to absorb • Please perform pump-down cooling operation when removing the existing air
the harmful ultraviolet rays in sunlight. Although R-22 conditioner.2 Refrigerant piping
(HCFC) refrigerant had been used in air conditioners and
Refrigerant R-22 R-410A R-32 • If you have any enquiries, please contact your local distributor and/or retailer.
refrigerators, it damages the ozone layer and its use is to Ozone
depletion 0.05 0 0
be mostly eliminated by 2020. To replace R-22, Taiwan, potential
Global
Japan and European countries with more progressive warming 1,810 2,090 675
potential1
regulations selected R-410A (HFC). However, R-410A
also has issues related to its high global warming potential.

Less Impact on Global Warming


The Earth retains solar heat in the daytime for warming and then releases Global warming potential1 Can your existing refrigerant piping be reused?
2,500
this heat at night, allowing it to maintain an optimal temperature range.
However, with greenhouse gases increasing, it is more difficult to 2,000
The existing piping has: The existing piping cannot be used.
discharge heat and the planet is gradually becoming warmer. This is • no exterior damage
1,500 No New piping is required.
called global warming. R-32 has only around 30% of the global warming • appropriate external/internal diameters
potential of R-410A and R-22. 1,000 2,090 1,810
• appropriate piping wall thickness
• separate insulation for liquid and gas pipes.
500 Yes
675
The old air conditioner can perform pump-down Recover the refrigerant using the appropriate
Greenhouse gases cause cooling operation.2 equipment.
damage which allows solar R-32 R-410A R-22 No
radiation to pass through the
Solar radiation Earth’s outer atmosphere while
Important Yes
Greenhouse gas
also trapping infrared radiation. After performing pump-down cooling operation3,
These gases rapidly increase Yes
Infrared radiation and interfere with the Earth’s close the liquid and gas stop valves.
ability to release heat into space,
Land
causing the ambient temperature Yes
Sea to rise.
Remove the old air conditioner.
Yes

Increased Energy Efficiency


Abrasion powder (iron powder, etc.) remains in the oil. Cleaning of the pipes is required.
Yes
Important No Yes
The potential refrigerating effect of R-32 is 1.5 times that of R-22 or R-410A. Perform flare connection for R-32 using the flare nut supplied with the new air conditioner.

The new air conditioner can be installed with the existing refrigerant piping.

Notes: 1. Global warming potential values are based on the Fourth Assessment Report from the Intergovernmental Panel on Climate Change (IPCC).
25 2. For pump-down operation, please follow the installation instructions or service manual. (Do not do it yourself without proper guidance.) 26
3. Please perform the pump-down cooling operation for five minutes for 2.5 and 3.5 kW models and 10 minutes for 5.0 kW or larger models.
Choice of Wide Range of Airflow Patt erns

Power-Airflow Flap and Power-Airflow Dual Flaps 3D Airflow


The Power-Airflow Flap and Power-Airflow Dual Flaps flatten out during cooling operation to deliver air to every part 3D Airflow combines Vertical and Horizon-
of a room. The flaps can direct warm air straight down to the floor during heating operation. Selecting the low angle tal Auto-Swing to reduce indoor tempera-
sends air right to the corners, while choosing the high angle spreads air around the centre. ture fluctuation. This function circulates air
The Power-Airflow Flap is available for the FTKM25/35, FTXV25/35, FTKC25/35, ATKC25/35, FTHF25/35 models and FTKQ series. to every part of a room for uniform cooling
The Power-Airflow Dual Flaps are available for the FTKM50/60/71, FTXV50/60/71, FTKC50/60/71 and FTHF50/60/71 models.
or heating of even large spaces. To start 3D 1
Airflow, push both the Vertical and Horizon-
tal Auto-Swing buttons. The flaps and
louvers swing in turn.
4 2
This function is available for the FTKM and FTXV series.

3
When you choose the low angle, cool air When you choose the high angle, cool
slides off to reach the corners of the room. air spreads around the centre of the room.

The flaps and louvers swing in turn, expanding the comfort zone.

Wide-Angle Louvers
The Wide-Angle Louvers provide effective airflow coverage no matter where the indoor unit is placed in a
room. The louvers deliver cool and warm air right to the corners of any space. The FTKM and FTXV series
can be adjusted directly from the wireless remote controller. Other units can be set manually.
Vertical Auto-Swing (up and down)
Vertical Auto-Swing automatically moves the flap up and down to
reduce temperature fluctuations in a room. The flap shuts automati-
cally when the air conditioner is turned off.

The louvers cover even


a spacious room.

The angles of the louvers can be freely adjusted


according to where people are in the room. If the
indoor unit is not positioned in the centre of the
wall, the louvers can be set to the left or right.

27 28
Energy Saving Functions

Living room Monday to Friday Bedroom Monday to Friday


Weekly Timer Programme 1 Programme 1

The Weekly Timer allows up to four actions to be programmed for each day of the week. It is possible to schedule not only
the on and off times but also to set temperatures. Once you set up the Weekly Timer, the air conditioner operates each day On On
without controller input. The Weekly Timer synchronises the air conditioner with your family’s schedule, greatly improving
comfort in your home.
22ºC If you set the Weekly Timer
30 minutes before your
wake-up time, you can avoid
23ºC Even if you go to bed at
12:00 a.m., the air
conditioner will start

This function is available for the FTKM and FTXV series. 6:30 a.m. the hot and humid morning
air and enjoy a pleasantly
11:30 p.m. operation 30 minutes
before to help you fall into
cool room as you get up. a comfortable sleep.

Programme 2 Programme 2

Off
8:00 a.m.
The Weekly Timer will
automatically stop
Off
3:00 a.m.
Even if you go to bed at
12:00 a.m., the air
conditioner will operate for
another three hours so you
continue to sleep comfortably.
operation after you leave Stopping operation during
home on a busy morning. the night prevents
You can forget about the air overcooling and saves you
conditioner. from catching a chill.

Programme 3 Programme 3

On On If you set the Weekly Timer

21ºC 23ºC
30 minutes before your
If you set the Weekly Timer wake-up time, you can
an hour before you arrive avoid the hot and humid
home, you can enjoy a morning air and enjoy a
5:30 p.m. wave of cool air as soon as
6:30 a.m. pleasantly cool room as
you step through the door. you get up.

Programme 4 Programme 4

Off
12:00 a.m.
Off
8:00 a.m.
The Weekly Timer will The Weekly Timer will
automatically stop operation automatically stop operation

Controller Buttons and Copy Function when you go to bed. when you leave home.

Deactivates, reactivates
You can set up the Weekly Timer using the
wireless remote controller. The copy function also
or deletes. Starts and completes settings. Econo Mode
enables a daily programme to be repeated on Normal operation
Moves back. Copies settings. This function limits the maximum power consumption. It helps to reduce power
other days as required. This makes it even easier
usage if the cooling load is high, for example, at startup or during large gatherings

Power consumption
to set the timer.
and periods of direct sunshine.
Moves forward.
Econo Mode
Maximum capacity decreases during Econo
Mode, requiring more time to reach the set
temperature.
Time
Selects timer.
Sets day, time

Standby Electricity Saving


and temperature.

Electrical appliances still use a surprising amount of power even when they are waiting in standby mode. Recognising
this, Daikin has developed the Standby Electricity Saving function to reduce this hidden power consumption.

29 30
Quiet Nights in Your Neighbourhood

Indoor Unit Quiet Operation Night Set Mode


The all series give you a choice of 5-step, Quiet or FTKM25SVMV during cooling operation Pressing the off timer button automatically selects Night Set Mode. This
Automatic settings for the fan speed. The Quiet Fan speeds Sound pressure levels function prevents excessive cooling or heating for a pleasant sleep.
setting selects Indoor Unit Quiet Operation, which After 60 minutes, the room temperature is raised by 0.5°C for cooling
decreases the sound pressure level by 3 to 9 dB(A) High (H) 42 dB(A)
operation or lowered by 2°C for heating operation.
below the Low setting. This wide range of settings
Low (L) 26 dB(A)
allows you to precisely control the fan speed
7 dB(A) Cooling
according to your needs. For example, the Quiet Quiet (SL) 19 dB(A) +0.5°C
function will help you to sleep more comfortably at Set temp. before
Off timer begins
night. The sound pressure level is just 19 dB(A)1 for Auto SL L M H to operate
the FTKM25/35, FTXV25/35, FTKC25 and ATKC25
models.
Fan speed Low High

Each decrease in airflow volume reduces the


Sound pressure level
sound pressure level. Heating
-2°C
Time
60 minutes
Off timer turns on Off timer stops
Outdoor Unit Quiet Operation air conditioner

This function decreases the sound pressure level by 3 to 7 dB(A) below


the rated operation. It provides a sound pressure level of 43 dB(A)1
RKC60TVMV 24 Hour On/Off Timer
Operations Sound pressure levels
for the RKM25, RXV25 and RKC50/60 models. Capacity may
This timer can start or stop the air conditioner within a 24 hour period.
decrease when Outdoor Unit Quiet Operation is selected. Rated (H) 50 dB(A)
This function is not available for the RKQ25/35/50/60 models. 7 dB(A) It can be preset in 10 minute steps by pressing the on/off timer button on
Quiet (SL) 43 dB(A) the wireless remote controller. The on timer and off timer can be used in
combination.
This function is available for the FTKM and FTXV series.
19 dB(A) is so quiet you can even hear whispers 2 dB(A)

19 20 30 40 43 50 Off timer at 1:00 a.m. and


On timer at 6:00 a.m.

Count Up-Down On/Off Timer


Indoor unit Rustling of Pendulum of Library Outdoor unit Normal office
leaves a wall clock The operation start and stop times can be set with the touch of a single
button and preset for a period of one to 12 hours in one hour increments.
Notes: 1. This value is for operation at 220 V, 50 Hz. When the off timer is set, Night Set Mode is activated automatically.
2. Based on “Examples of Sound Pressure Levels”, Ministry of the Environment, Japan, November 2002.

Stops the unit after three hours


31 and starts it again eight hours later. 32
Easy to Keep Room Air Clean

Titanium Apatite Deodorising Filter Removable Drain Pan


While the filter’s micron-level fibres trap dust, titanium apatite effectively adsorbs The drain pan collects condensation formed on the indoor heat exchanger fins. The drain pan can be
odours and allergens, as well as deodorises odours. This filter delivers consistent removed easily without any disassembly. This design dramatically reduces cleaning time and ensures a
performance for approximately three years if it is washed with water once every perfect finish.
six months. The FTKQ series can be equipped with this filter as an option. This filter is not a medical device. Benefits such as the
adsorption of odours and allergens and deodorisation of
odours are only effective for substances which are directly
attached to the Titanium Apatite Deodorising Filter.

The drain pan and louvers can be easily detached after simply removing the front panel and screws.

Air filter catches dust

Titanium Apatite Deodorising Filter


Dust Collection Filter (PM2.5)1 (optional accessory)
This filter removes PM 2.5, particulate matter which is smaller than 2.5 micrometres (µm). 1 µm is equal
to 1/1,000 mm. PM 2.5 is small enough to be breathed deep into the lungs.The filter can not be cleaned
and we recommend replacing it every six months.

How Small Is PM 2.5?2


PM 2.5 is directly produced when substances are burned in boilers,
incinerators, heaters and vehicle and ship engines. It also occurs
when sulphur and nitrogen oxides emitted by the combustion of fuel in
thermal power plants and vehicle and ship engines react with light and
Mould-Proof Air Filter PM 2.5: 2.5 µm in diameter
(zoomed to 10 times in the circle below) ozone in the air.
The air filter is impregnated with a mould
preventative. The substance stops any
growth, increase in number or activity by
mould on the filter surface.

PM 2.5 Cedar pollen: Human hair:


30 µm in average 70 µm in average
diameter3 diameter3

Notes:
1. This filter is not a medical device and it does not have any certification. The effectiveness of the filter depends on the room conditions and usage of the air conditioner.
2. The picture is sourced from the Bureau of Environment of the Tokyo Metropolitan Government, http://www.kankyo.metro.tokyo.jp/air/air_pollution/PM2.5/index.html
3. The figures are sourced from the Office of Research and Development of the US Environmental Protection Agency.
33 34
Remote Control via Smartphone

Functions
Daikin Mobile Controller (optional adaptor)
Start/stop operation Demonstrate login mode supported
The Daikin mobile controller application lets you manage Daikin inverter air conditioners from
Set operation mode Set child-proof lock 3
anywhere, helping to maintain a comfortable home environment while saving energy.
This convenient app gives you full control of core functions such as start/stop, operation mode Set room temperature Set weekly timer:
and set temperature as well as advanced features like weekly scheduling. The app also lets you
Set fan speed3 • Start/stop operation
monitor your system to ensure it is performing as desired.
• Operation mode and room temperature
Setup is extremely easy. After downloading the software, you only need to connect to a private Set airflow direction3
wireless network inside your home or mobile network outside.1
(maximum of six actions per day,
Monitor current room temperature 42 actions in total)
• Vacation mode for long holidays
Monitor current outdoor temperature4

System Configuration
In Home
Operation Wireless Internet Environment at Home
At home, the Daikin mobile controller application
turns your smartphone into a centralised remote

New Page
controller.2 It only takes a few easy taps to check Internet
and adjust the temperature in a child’s room on
the second floor from the living room. You can
also start and stop the air conditioner in the living Daikin mobile controller5 Wireless router
room from your bedroom. (optional adaptor) Daikin mobile controller
BRP072A42 application (free)
Simply download the application
Remote control PC-board set and register your air conditioners.
(optional adaptor) Smartphone

KRP067A41 or KRP980B2

For applicable models, go to http://www.daikinthai.com/dmobile/.


A Daikin mobile controller (optional adaptor) is required for each indoor unit to enable control from smartphones.

Out of Home
Operation
Required for Operation

Daikin mobile controller5


The Daikin mobile controller application takes (optional adaptor) (1) (2)
care of those nagging worries about whether you BRP072A42 + AndroidTM* phone
or iPhone**
+ Daikin mobile controller
application (free) +
(3)
Wireless router + Internet
turned off the air conditioner and ensures a Remote control PC-board set
(optional adaptor)
comfortable air conditioned environment is * Android is a trademark of Google Inc.
KRP067A41 or KRP980B2
waiting when you return home. Even outside your ** iPhone is a trademark of Apple Inc.
home, you can easily monitor and adjust points Users need to prepare items (1) to (3).
such as the operating status and room tempera- A Daikin mobile controller (optional adaptor) is required for each indoor unit.

ture or start and stop all units.

Notes: 1. For applicable OSs, go to http://www.daikinthai.com/dmobile/.


An Internet connection is required to use this service. Standard smartphone charges also apply when using the Daikin mobile controller application to
monitor or control air conditioners.
2. In-home control of air conditioners using the Daikin mobile controller application will depend on the effective coverage area of your LAN.
3. The controllable functions differ depending on the model.
4. Monitoring of the outdoor temperature is available for all models during operation. Some models can also perform monitoring while they are not operating.
35 5. A remote control PC-board set (optional adaptor) is also required for all models. 36
Function List
FTKM FTXV FTKC and ATKC FTHF FTKQ
Indoor Unit Cooling Only Heat Pump Cooling Only Heat Pump Cooling Only

Functions Models FTKM25/35 FTKM50/60/71 FTXV25/35 FTXV50/60/71 FTKC25/35 ATKC25/35 FTKC50/60/71 FTHF25/35 FTHF50/60/71 FTKQ25/35/50/60
DC Inverter Control
Hybrid Cooling (dehumidification control)

Power-Airflow Dual Flaps


Power-Airflow Flap
Comfortable Airflow

Wide-Angle Louvers

Vertical Auto-Swing (up and down)


Horizontal Auto-Swing (left and right)
3D Airflow

Comfort Airflow Mode


Indoor Unit Quiet Operation

Automatic Operation
Comfort Control

Auto Fan Speed


Intelligent Eye (auto energy saving)
Two-Area Intelligent Eye (focus and comfort)
Programme Dry Function
Standby Electricity Saving
Lifestyle Convenience

Econo Mode
Inverter Powerful Operation
Wireless Remote Controller with Backlight
Wireless Remote Controller with Luminous Button
Daikin Mobile Controller (optional adaptor)

Indoor Unit On/Off Switch


Titanium Apatite Deodorising Filter optional accessory

Dust Collection Filter (PM 2.5)(optional accessory)


Cleanliness

Mould-Proof Air Filter


Odour Removal
Wipe-Clean Flat Panel
Removable Drain Pan

24 Hour On/Off Timer


Count Up-Down On/Off Timer
Timers

Weekly Timer
Night Set Mode
Worry Free

Auto-Restart after Power Failure


Self-Diagnosis with Digital Display

Outdoor Unit RKM RXV RKC and ARKC RHF RKQ


Functions Models RKM25/35 RKM50/60/71 RXV25/35 RXV50/60/71 RKC25/35 ARKC25/35 RKC50/60/71 RHF25/35 RHF50/60/71 RKQ25/35/50/60
Comfort Control Outdoor Unit Quiet Operation

Stabiliser
Free
Stabiliser Free
Worry Free Low/High Voltage Shield
Anti-Corrosion Treatment of Outdoor Heat Exchanger Fins
37 38
Functions

Comfortable Airflow Lifestyle Convenience Comfort Control Timers


Power-Airflow Dual Flaps Standby Electricity Saving Indoor Unit Quiet Operation 24 Hour On/Off Timer
The Power-Airflow Dual Flaps can flatten out during cooling operation to Even when an air conditioner is not operating, it requires standby power. Indoor unit operating sound pressure levels are decreased from the Low This timer can start or stop the air conditioner within a 24 hour period. It
deliver cool air to the corners of a room. The flaps can direct warm air However, thanks to this function, the required standby power can be reduced. setting fan speed using the wireless remote controller. can be preset in 10 minute steps by pressing the on/off timer button on
straight down to the floor during heating operation. See page 30 See page 31 the wireless remote controller. The on timer and off timer can be used in
See page 27 combination.
See page 32
Econo Mode Outdoor Unit Quiet Operation
Power-Airflow Flap This mode limits the maximum power consumption. It improves operating Outdoor unit operating sound pressure levels can be decreased from the
The Power-Airflow Flap flattens out during cooling operation to deliver efficiency and also prevents circuit breakers from being overloaded. rated operation sound using the wireless remote controller. Count Up-Down On/Off Timer
cool air to the corners of a room. The flap also directs warm air straight See page 30 See page 31 The operation start and stop times can be set with the touch of a single
down to the floor during heating operation. button and preset for a period of one to 12 hours in one hour increments.
See page 27 When the off timer is set, Night Set Mode is activated automatically.
Inverter Powerful Operation Automatic Operation
See page 32
This function boosts cooling or heating performance for a 20 minute This function automatically selects cooling or heating operation mode
Wide-Angle Louvers period. It is convenient when it is necessary to change the room based on the room temperature at startup.
The Wide-Angle Louvers provide wide airflow coverage for effective temperature quickly.
See page 22 Weekly Timer
operation no matter where the indoor unit is placed in a room. See page 14 The Weekly Timer allows up to four actions to be programmed for
each day of the week. It is possible to schedule not only the on and
See page 28 Auto Fan Speed
off times, but also the desired temperatures during these periods. The
Wireless Remote Controller with Backlight The microprocessor automatically adjusts the fan speed to high to rapidly
copy function also makes the setting much easier and enables a daily
Vertical Auto-Swing (up and down) The backlit LCD allows easy operation in the dark. Frequently used reach the set temperature. Once the temperature is achieved, this function
programme to be repeated on other days as required.
This function automatically moves the flaps up and down to distribute air functions are conveniently located on the front of the controller. reduces the fan speed to low.
See pages 29 and 30
across a room. See page 20 See page 11

Wireless Remote Controller with Night Set Mode


Horizontal Auto-Swing (left and right) Intelligent Eye (auto energy saving) Pressing the off timer button automatically selects Night Set Mode. This
Horizontal Auto-Swing automatically moves the louvers to the left and Luminous Button Intelligent Eye with its infrared sensor automatically controls air function prevents excessive cooling or heating for a pleasant sleep. After
right to cover a room with cool or warm air. The luminous button absorbs and saves light and then slowly releases it. conditioner operation according to human movement in a room. When 60 minutes, the room temperature is raised by 0.5˚C for cooling
This makes it easy to see in the dark. there is no movement for 20 minutes, it adjusts the temperature by operation or lowered by 2˚C for heating operation.
See page 20 approximately 2°C for energy savings. See page 32
3D Airflow See page 20
This function combines Vertical and Horizontal Auto-Swing to circulate a Top view Side view
7m
cloud of cool or warm air right to the corners of even large spaces. The
flaps and louvers swing in turn.
Daikin Mobile Controller (optional adaptor) Worry Free
This optional adaptor and its application turn a smartphone into a remote 7m
See page 28
controller that can be used inside or outside the home. Together they help 90˚
to maintain comfort while saving energy and eliminate any worries about
110˚
Auto-Restart after Power Failure
Comfort Airflow Mode forgetting to turn off the air conditioner. The air conditioner memorises the settings for operation mode (automatic,
This function prevents uncomfortable drafts from blowing directly on to See pages 35 and 36 cooling, heating, dry and fan only), airflow, temperature, etc., and
the body. To prevent drafts, the flap moves upward during cooling automatically returns to them when power is restored after a power failure.
operation and downward during heating operation. Two-Area Intelligent Eye (focus and comfort)
See page 18
Indoor Unit On/Off Switch
The unit can be conveniently This function uses its infrared sensor to direct airflow either toward or Self-Diagnosis with Digital Display
started by hand if the wireless away from people. Malfunction codes are shown on the digital display panel of the wireless
remote controller is misplaced or See page 18 remote controller for fast and easy maintenance.
its batteries are not charged.

Indoor Unit On/Off Switch


Programme Dry Function Low/High Voltage Shield
The computer chip works to rid the room of humidity while keeping the All electrical components in indoor and outdoor units are designed for
Cleanliness room temperature as stable as possible. It controls the temperature and extreme durability. Their printed circuit boards can easily handle large
airflow rate automatically, so manual adjustment of these functions is variations in voltage, ensuring they always operate reliably.
Titanium Apatite Deodorising Filter Wipe-Clean Flat Panel not available. See pages 14 and 24
This filter contains titanium apatite. While the filter’s micron-level The flat panel design can be cleaned with only the single pass of a cloth
fibres trap dust, the titanium apatite adsorbs odours and allergens, as across its smooth surface. The flat panel can also be easily removed for
well as deodorises odours. The filter can be used for up to three years more thorough cleaning. Stabiliser Free
with proper maintenance. Stabiliser The highly durable electronic circuit eliminates the need for a stabiliser.
Free It can handle overload voltage of up to 440 V, offering reliable protection
See page 33 Mould-Proof Air Filter
The air filter is impregnated with a mould preventative. The substance against dangerous overvoltage. It also protects outdoor unit devices such
as the fan motor and compressor.
Dust Collection Filter (PM 2.5) (optional accessory) stops any growth, increase in number or activity by mould on the
This filter removes PM 2.5, particulate matter which is smaller than 2.5 filter surface.
micrometres (µm). 1 µm is equal to 1/1,000 mm. PM 2.5 is small See page 24 Anti-Corrosion Treatment of Outdoor
enough to be breathed deep into the lungs. This filter should be Heat Exchanger Fins
replaced every six months because it can not be cleaned. Removable Drain Pan The outdoor unit’s heat exchanger fins are processed using a special
See page 34 The drain pan collects condensation from the indoor heat exchanger fins. anti-corrosion treatment. The surface is covered with a thin acrylic resin
Removable drain pans help to reduce the cleaning time and ensure a layer to enhance the fins’ resistance to acid rain and salt corrosion.
Odour Removal perfect finish. See page 14
When the cooling and dry operation starts working, the indoor unit See page 34
absorbs unpleasant odours before distributing the air.
See page 16

39 40
Wireless Remote Controller

FTKM Series Cooling Only FTXV Series Heat Pump

FTKM25/35 Wireless Remote Controller FTXV25/35 Wireless Remote Controller


with Backlight with Backlight
On and off switch 1 11 Sets room temperature. On and off switch 1 11 Sets room temperature.
Selects fan speed. 12 Econo Mode and Selects fan speed. 12 Econo Mode and
Auto Fan Speed and 2 Outdoor Unit Quiet Operation Auto Fan Speed and 2 Outdoor Unit Quiet Operation
Indoor Unit Quiet Operation Indoor Unit Quiet Operation
Selects vertical airflow direction. Selects vertical airflow direction.
1 1
Inverter Powerful Operation 3 13 Vertical Auto-Swing and Inverter Powerful Operation 3 13 Vertical Auto-Swing and
2 3D Airflow 2 3D Airflow
11 Selects operation mode: 11
Selects operation mode: 3 3
Cooling, Dry and Fan Only. 4 Selects horizontal airflow direction. Automatic Operation, 4 Selects horizontal airflow direction.
12 12
14 Horizontal Auto-Swing and Cooling, Heating, Dry and Fan Only. 14 Horizontal Auto-Swing and
4 13 4 13
3D Airflow 3D Airflow
Comfort Airflow Mode 5 5 14 Comfort Airflow Mode 5 5 14
6 Weekly Timer: 6 Weekly Timer:
New Two-Area Intelligent Eye 6 New Two-Area Intelligent Eye 6
Weekly Deactivates, reactivates or deletes Weekly Deactivates, reactivates or deletes

24 Hour Off Timer, 15 Weekly Timer setting. 24 Hour Off Timer, 15 Weekly Timer setting.
7 7
Count Up-Down Off Timer and 7 Starts and completes settings. Count Up-Down Off Timer and 7 Starts and completes settings.
8 8
Night Set Mode Copy
Copies settings. Night Set Mode Copy
Copies settings.
9 9
10
Back
Moves back. 10
Back
Moves back.
Cancels timers. 8 Cancels timers. 8
Next
Moves forward. Next
Moves forward.
Selects timer. Sets day, Selects timer. Sets day,
time and temperature. 9 15 24 Hour On Timer and time and temperature. 9 15 24 Hour On Timer and
Count Up-Down On Timer Count Up-Down On Timer
Sets clock. 10 Sets clock. 10

FTKM50/60/71 Wireless Remote Controller FTXV50/60/71 Wireless Remote Controller


On and off switch 1 with Backlight On and off switch 1 with Backlight
11 Sets room temperature. 11 Sets room temperature.
Selects fan speed. Selects fan speed.
Auto Fan Speed and 2 12 Econo Mode and Auto Fan Speed and 2 12 Econo Mode and
Indoor Unit Quiet Operation Outdoor Unit Quiet Operation Indoor Unit Quiet Operation Outdoor Unit Quiet Operation
Selects vertical airflow direction. Selects vertical airflow direction.
Inverter Powerful Operation 3 1 Inverter Powerful Operation 3 1
13 Vertical Auto-Swing and 13 Vertical Auto-Swing and
3D Airflow Selects operation mode: 3D Airflow
Selects operation mode: 2 11 2 11
4 Automatic Operation, 4
Cooling, Dry and Fan Only. 3 Selects horizontal airflow direction. 3 Selects horizontal airflow direction.
12 Cooling, Heating, Dry and Fan Only. 12
14 Horizontal Auto-Swing and 14 Horizontal Auto-Swing and
Comfort Airflow Mode 5 4 13 Comfort Airflow Mode 5 4 13
3D Airflow 3D Airflow
5 14 5 14
Intelligent Eye 6 6 Intelligent Eye 6 6
Weekly Timer: Weekly Timer:
Weekly Deactivates, reactivates or deletes Weekly Deactivates, reactivates or deletes
24 Hour Off Timer, 24 Hour Off Timer,
7 7 15 Weekly Timer setting. 7 7 15 Weekly Timer setting.
Count Up-Down Off Timer and Count Up-Down Off Timer and
8 Starts and completes settings. 8 Starts and completes settings.
Night Set Mode Night Set Mode
9
Copy
Copies settings. 9
Copy
Copies settings.
Cancels timers. 8 Back
Moves back. Cancels timers. 8 Back
Moves back.
10 10
Next
Moves forward. Next
Moves forward.
Selects timer. Sets day, Selects timer. Sets day,
time and temperature. 9 time and temperature. 9
15 24 Hour On Timer and 15 24 Hour On Timer and
Sets clock. 10 Count Up-Down On Timer Sets clock. 10 Count Up-Down On Timer

41 42
Wireless Remote Controller

FTKC Series Cooling Only


FTHF Series Heat Pump

FTKC25/35/50/60/71 FTHF25/35/50/60/71
Wireless Remote Controller
with Backlight

Starts cooling operation. 1 9 Off switch Starts operation. 9 Off switch


Automatic Operation 1
10 Starts dry operation.
Starts dry operation. 2 10 Starts fan only operation.
1 9 Starts cooling operation. 2 1 9
11 Starts fan only operation.
2 10 Selects fan speed.
Sets room temperature. 3 2 10
11 Auto Fan Speed and Starts heating operation. 3 Selects fan speed.
Indoor Unit Quiet Operation 3 11 12 Auto Fan Speed and
Inverter Powerful Operation 4 Sets room temperature. 4 Indoor Unit Quiet Operation
11 4 12
3 12 Econo Mode
Intelligent Eye 5 12 Inverter Powerful Operation 5 13 13 Econo Mode
4 13 Selects airflow angle. 5
Vertical Auto-Swing
Outdoor Unit Quiet Operation 6
5 13 Intelligent Eye 6 6 14 14 Selects airflow angle.
Vertical Auto-Swing
6 14 14 Comfort Airflow Mode 7 15
Outdoor Unit Quiet Operation 7
Night Set Mode and 7 15 Comfort Airflow Mode
7 16
15 Cancels timers.
Count Up-Down Off Timer 8 15 Count Up-Down On Timer 8 8 17
Night Set Mode and
16
Count Up-Down Off Timer
Count Up-Down On Timer 8
17 Cancels timers.

ATKC Series Cooling Only


FTKQ Series Cooling Only

ATKC25/35 FTKQ25/35/50/60

Starts cooling operation. 1 9 Off switch Starts cooling operation. 1 7 Off switch

Starts dry operation. 2 10 Starts fan only operation. Starts dry operation. 2 8 Starts fan only operation.
1 9 1 7
2 10 Selects fan speed. 2 8 Selects fan speed.
Sets room temperature. 3 Sets room temperature. 3
11 Auto Fan Speed and 9 Auto Fan Speed and
Indoor Unit Quiet Operation Indoor Unit Quiet Operation
Inverter Powerful Operation 4 Inverter Powerful Operation 4
11 9
3 12 Econo Mode 3 10 Econo Mode
Intelligent Eye 5 12 Comfort Airflow Mode 5 10
4 13 Selects airflow angle. 4 11 Selects airflow angle.
5 13 Vertical Auto-Swing 5 11 Vertical Auto-Swing
Outdoor Unit Quiet Operation 6 Count Up-Down On Timer 6
6 14 14 Comfort Airflow Mode Night Set Mode and
12 12
Count Up-Down Off Timer
Night Set Mode and 7 6 13
7 15 Cancels timers.
Count Up-Down Off Timer 8 15 13 Cancels timers.

Count Up-Down On Timer 8

43 44
Specifications

FTKM Series Cooling Only FTXV Series Heat Pump


Indoor unit FTKM25SVMV FTKM35SVMV FTKM50SVMV FTKM60SVMV FTKM71SVMV Indoor unit FTXV25QVMV FTXV35QVMV FTXV50QVMV FTXV60QVMV FTXV71QVMV
Model name Outdoor unit Model name
RKM25SVMV RKM35SVMV RKM50SVMV RKM60SVMV RKM71SVMV Outdoor unit RXV25QVMV RXV35QVMV RXV50QVMV RXV60QVMV RXV71QVMV
kW 2.5 (1.2-3.6) 3.5 (1.2-4.1) 5.2 (1.2-6.2) 6.0 (1.2-7.1) 7.1 (1.2-8.2) kW 2.5 (0.9-3.7) 3.5 (0.9-4.2) 5.0 (1.1-6.7) 6.0 (1.1-7.5) 7.1 (2.0-8.9)
Rated Rated
Capacity 8,500 11,900 17,700 20,500 24,200 Cooling 8,500 11,900 17,100 20,500 24,200
(Min.-Max.) Btu/h (Min.-Max.) Btu/h
(4,100-12,300) (4,100-14,000) (4,100-21,200) (4,100-24,200) (4,100-28,000) (3,100-12,600) (3,100-14,300) (3,800-22,900) (3,800-25,600) (6,800-30,400)
Capacity
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz kW 3.2 (0.9-5.3) 3.7 (0.9-5.3) 6.0 (1.0-8.0) 7.2 (1.0-8.6) 8.0 (2.0-10.6)
Heating Rated
Running current Rated A 2.6 4.4 5.9 7.2 10.5 10,900 12,600 20,500 24,600 27,300
(Min.-Max.) Btu/h
Power consumption Rated (Min._Max.) W 520 (185-920) 900 (185-1,160) 1,240 (290-1,880) 1,520 (290-2,230) 2,260 (290-2,770) (3,100-18,100) (3,100-18,100) (3,400-27,300) (3,400-29,300) (6,800-36,200)
CSPF 7.40 6.53 6.73 6.21 5.87 Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Indoor unit FTKM25SVMV FTKM35SVMV FTKM50SVMV FTKM60SVMV FTKM71SVMV Cooling 2.3 3.9 5.5 7.2 9.2
Running current Rated A
Front panel colour Pure white Heating 3.1 3.7 6.4 8.3 9.5
Airflow rate H m3/min (cfm) 10.1 (357) 16.8 (593) 18.6 (657) 19.8 (699) Cooling Rated 490 (230-1,050) 810 (230-1,300) 1,140 (280-2,000) 1,520 (280-2,380) 1,930 (450-3,350)
Power consumption W
Fan speed 5 steps, quiet and automatic Heating (Min.-Max.) 650 (190-1,480) 770 (190-1,440) 1,330 (220-2,350) 1,740 (220-2,650) 2,020 (390-3,580)
Sound pressure levels H/L/SL dB(A) 42/26/19 43/28/19 45/35/29 48/37/29 49/37/30 CSPF 6.21 6.24 6.35 5.81 4.65
Dimensions HxWxD mm 285 x 770 x 226 295 x 990 x 266 Indoor unit FTXV25QVMV FTXV35QVMV FTXV50QVMV FTXV60QVMV FTXV71QVMV
Machine weight kg 9 13 Front panel colour Pure white
Outdoor unit RKM25SVMV RKM35SVMV RKM50SVMV RKM60SVMV RKM71SVMV Cooling m3/min 10.0 (353) 10.5 (371) 16.0 (565) 18.6 (657) 18.6 (657)
Airflow rate H
Casing colour Ivory white Heating (cfm) 10.1 (357) 11.0 (388) 17.2 (607) 20.0 (706) 19.7 (696)
Type Hermetically sealed swing type Fan speed 5 steps, quiet and automatic
Compressor
Motor output W 800 1,300 Cooling 40/25/19 42/26/19 45/35/28 48/36/29 49/37/30
Sound pressure levels H/L/SL dB(A)
Type R-32 Heating 40/28/20 42/29/20 45/33/28 48/33/29 49/35/30
Refrigerant
Charge volume kg 0.59 0.62 Dimensions HxWxD mm 285 × 770 × 223 295 × 990 × 263
Sound pressure levels H/SL dB(A) 46/43 47/44 47/44 49/45 52/49 Machine weight kg 9 13
Dimensions HxWxD mm 595 x 845 x 300 695 x 930 x 350 Outdoor unit RXV25QVMV RXV35QVMV RXV50QVMV RXV60QVMV RXV71QVMV
Machine weight kg 32 44 46 Casing colour Ivory white
Operation range °CDB 19.4 to 46 Type Hermetically sealed swing type
Compressor
Liquid ø6.4 Motor output W 800 1,300 2,400
Piping
Gas mm ø9.5 ø12.7 Type R-32
connection Refrigerant
Drain ø16.0 Charge volume kg 0.85 1.50 1.60
Max. piping length 20 30 Cooling 47/43 49/44 47/44 49/45 53/49
m Sound pressure levels H/SL dB(A)
Max. level difference 15 20 Heating 48/44 49/45 48/45 52/45 54/49
Dimensions HxWxD mm 550 x 675 x 284 695 x 930 x 350
Measurement conditions Machine weight kg 30 54 60
1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
2. Sound pressure levels are based on the temperature conditions in 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of
Cooling °CDB -10 to 46
Operation range
ambient conditions. Heating °CWB -15 to 18
3. CSPF is based on TCVN 7830: 2015 conditions.
Liquid ø 6.4
Piping
Gas mm ø 9.5 ø12.7 ø15.9
connection
Drain ø16.0
Max. piping length 20 30
m
Max. level difference 15 20
Note: The above values are based on operation with a 220 V, 50 Hz power supply.

Measurement conditions
1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 5 m.
2. Heating capacity is based on: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; piping length 5 m.
3. Sound pressure levels are measured in an anechoic chamber based on the temperature conditions in 1 and 2 above. These values are normally somewhat higher during actual operation as a result of
ambient conditions.
4. CSPF is based on TCVN 7830: 2015 conditions.

45 46
Specifications

FTKC Series Cooling Only ATKC Series Cooling Only


Indoor unit FTKC25TVMV FTKC35TVMV FTKC50TVMV FTKC60TVMV FTKC71TVMV Indoor unit ATKC25TVMV ATKC35TVMV
Outdoor unit RKC25TVMV RKC35TVMV RKC50TVMV RKC60TVMV RKC71TVMV Outdoor unit ARKC25TVMV ARKC35TVMV
Model name Model name
Indoor unit FTKC25TAVMV FTKC35TAVMV Indoor unit ATKC25TAVMV ATKC35TAVMV
Outdoor unit RKC25TAVMV RKC35TAVMV Outdoor unit ARKC25TAVMV ARKC35TAVMV
kW 2.5 (1.0-3.4) 3.5 (1.3-4.1) 5.2 (1.4-6.0) 6.0 (1.4-6.7) 7.1 (2.1-7.5) kW 2.5 (1.0-3.4) 3.5 (1.3-4.1)
Rated Rated
Capacity 8,500 11,900 17,700 20,500 24,200 Capacity 8,500 11,900
(Min.-Max.) Btu/h (Min.-Max.) Btu/h
(3,400-11,600) (4,400-14,000) (4,800-20,500) (4,800-22,900) (7,200-25,600) (3,400-11,600) (4,400-14,000)
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Running current Rated A 3.20 4.5 6.3 8.0 10.9 Running current Rated A 3.20 4.5
Power consumption Rated (Min._Max.) W 680 (210-1,100) 960 (250-1,455) 1,365 (260-1,730) 1,740 (300-2,060) 2,365 (400-2,550) Power consumption Rated (Min._Max.) W 680 (210-1,100) 960 (250-1,455)
CSPF 5.70 5.65 6.05 5.82 5.75 CSPF 5.70 5.65
FTKC25TVMV FTKC35TVMV FTKC50TVMV FTKC60TVMV FTKC71TVMV ATKC25TVMV ATKC35TVMV
Indoor unit Indoor unit
FTKC25TAVMV FTKC35TAVMV ATKC25TAVMV ATKC35TAVMV
Front panel colour Shiny pure white Front panel colour
Airflow rate H m3/min (cfm) 9.9 (350) 10.8 (381) 16.7 (590) 17.3 (611) Airflow rate H m3/min (cfm) 9.9 (350) Shiny pure white 10.8 (381)
Fan speed 5 steps, quiet and automatic Fan speed
Sound pressure levels H/L/SL dB(A) 38/25/19 39/26/22 44/35/29 45/36/29 46/37/31 Sound pressure levels H/L/SL dB(A) 38/25/19 5 steps, quiet and automatic 39/26/22
Dimensions HxWxD mm 285 x 770 x 226 295 x 990 x 266 Dimensions HxWxD mm 285 x 770 x 226
Machine weight kg 8 13 Machine weight kg 8
RKC25TVMV RKC35TVMV RKC50TVMV RKC60TVMV RKC71TVMV ARKC25TVMV ARKC35TVMV
Outdoor unit Outdoor unit
RKC25TAVMV RKC35TAVMV ARKC25TAVMV ARKC35TAVMV
Casing colour Ivory white Casing colour Ivory white
Type Hermetically sealed swing type Type Hermetically sealed swing type
Compressor Compressor
Motor output W 500 700 1,200 1,300 Motor output W 500 700
Type R-32 Type R-32
Refrigerant Refrigerant
Charge volume kg 0.50 0.70 1.0 1.05 Charge volume kg 0.50 0.70
Sound pressure levels H/SL dB(A) 47/44 49/45 49/43 50/43 51/46 Sound pressure levels H/SL dB(A) 47/44 49/45
Dimensions HxWxD mm 550 x 658 x 275 595 x 845 x 300 Dimensions HxWxD mm 550 x 658 x 275
Machine weight kg 23 26 36 40 Machine weight kg 23 26
Operation range °CDB 19.4 to 46 Operation range °CDB 19.4 to 46
Liquid ø6.4 Liquid ø6.4
Piping Piping
Gas mm ø9.5 ø12.7 ø15.9 Gas mm ø9.5
connection connection
Drain ø16.0 Drain ø16.0
Max. piping length 15 30 Max. piping length 15
m m
Max. level difference 12 20 Max. level difference 12

Measurement conditions Measurement conditions


1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m. 1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
2. Sound pressure levels are based on the temperature conditions in 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of 2. Sound pressure levels are based on the temperature conditions in 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of
ambient conditions. ambient conditions.
3. CSPF is based on TCVN 7830: 2015 conditions. 3. CSPF is based on TCVN 7830: 2015 conditions.

47 48
Specifications

FTHF Series Heat Pump FTKQ Series Cooling Only


Indoor unit FTHF25RVMV FTHF35RVMV FTHF50RVMV FTHF60RVMV FTHF71RVMV Indoor unit FTKQ25SVMV FTKQ35SVMV FTKQ50SVMV FTKQ60SVMV
Model name Outdoor unit RHF25RVMV RHF35RVMV RHF50RVMV RHF60RVMV RHF71RVMV Outdoor unit RKQ25SVMV RKQ35SVMV RKQ50SVMV RKQ60SVMV
Model name
kW 2.5 (1.0-3.4) 3.5 (1.2-3.8) 5.0 (1.6-6.0) 6.0 (1.6-6.7) 7.1 (2.1-7.5) Indoor unit FTKQ25SAVMV FTKQ35SAVMV
Cooling Rated
8,500 11,900 17,100 20,500 24,200 Outdoor unit RKQ25SAVMV RKQ35SAVMV
(Min.-Max.) Btu/h
(3,400-11,600) (4,100-13,000) (5,500-20,500) (5,500-22,900) (7,200-25,600) kW 2.65 (1.0-2.9) 3.50 (1.3-3.8) 5.0 (1.4-5.4) 6.0 (1.7-6.0)
Capacity Rated
kW 2.5 (1.0-3.4) 3.5 (1.2-3.8) 5.0 (1.6-6.0) 6.0 (1.6-6.7) 7.1 (2.1-7.5) Capacity 9,000 11,900 17,100 20,500
Heating Rated (Min.-Max.) Btu/h
8,500 11,900 17,100 20,500 24,200 (3,400-9,900) (4,400-13,000) (4,800-18,400) (5,800-20,500)
(Min.-Max.) Btu/h
(3,400-11,600) (4,100-13,000) (5,500-20,500) (5,500-22,900) (7,200-25,600) Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz Running current A 3.8 5.6 8.1 10.3
Rated
Cooling 2.90 4.60 6.10 8.0 10.9 Power consumption W 810 (220-990) 1,200 (250-1,460) 1,730 (355-2,070) 2,210 (370-2,510)
Running current Rated A
Heating 3.00 4.60 6.10 8.3 10.9 CSPF 4.50 4.60 4.45 4.78
Cooling Rated 610 (200-1,170) 980 (200-1,440) 1,315 (350-1,740) 1,740 (360-1,950) 2,370 (700-2,500) FTKQ25SVMV FTKQ35SVMV FTKQ50SVMV FTKQ60SVMV
Power consumption W Indoor unit
Heating (Min.-Max.) 610 (200-910) 980 (230-1,120) 1,315 (350-1,740) 1,740 (360-1,950) 2,370 (700-2,500) FTKQ25SAVMV FTKQ35SAVMV
CSPF 6.00 5.30 6.30 5.70 5.50 Front panel colour Shiny white
Indoor unit FTHF25RVMV FTHF35RVMV FTHF50RVMV FTHF60RVMV FTHF71RVMV Airflow rate H m3/min (cfm) 9.4 (330) 9.6 (339) 12.7 (448) 13.2 (466)
Front panel colour Shiny pure white Pure white Fan speed 5 steps, quiet and automatic
Cooling m3/min 10.2 (360) 10.7 (378) 18.2 (643) 20.1 (710) Sound pressure levels H/L/SL dB(A) 36/27/23 37/28/24 44/35/29 45/37/31
Airflow rate H
Heating (cfm) 10.3 (364) 10.8 (381) 19.5 (689) 21.5 (759) Dimensions HxWxD mm 285 x 770 x 223
Fan speed 5 steps, quiet and automatic Machine weight kg 8
Cooling 40/29/25 41/30/26 44/35/28 44/36/30 46/37/31 RKQ25SVMV RKQ35SVMV RKQ50SVMV RKQ60SVMV
Sound pressure levels H/L/SL dB(A) Outdoor unit
Heating 40/30/27 41/31/28 44/35/32 44/35/32 46/37/34 RKQ25SAVMV RKQ35SAVMV
Dimensions HxWxD mm 283 × 770 × 226 295 × 990 × 266 Casing colour Ivory white
Machine weight kg 8 13 Type Hermetically sealed swing type
Compressor
Outdoor unit RHF25RVMV RHF35RVMV RHF50RVMV RHF60RVMV RHF71RVMV Motor output W 500 650 1,200 1,300
Casing colour Ivory white Type R-32
Refrigerant
Type Hermetically sealed swing type Charge volume kg 0.50 0.65 0.80 0.85
Compressor
Motor output W 700 1,200 1,300 Sound pressure levels H dB(A) 49 51 52
Type R-32 Dimensions HxWxD mm 418 x 695 x 244 550 x 658 x 275 595 x 845 x 300
Refrigerant
Charge volume kg 0.70 1.00 1.05 Machine weight kg 21 26 36 40
Cooling 48/44 48/45 47/44 47/44 51/45 Operation range °CDB 19.4 to 46
Sound pressure levels H/SL dB(A)
Heating 48/44 48/45 48/45 49/45 52/46 Liquid ø6.35
Piping
Dimensions HxWxD mm 550 x 658 x 275 595 x 845 x 300 Gas mm ø9.52 ø12.7
connection
Machine weight kg 27 36 39 Drain ø16.0
Cooling °CDB 10 to 46 Max. piping length 15 30
Operation range m
Heating °CWB 1 to 20 Max. level difference 12 20
Liquid ø 6.4
Piping Measurement conditions
Gas mm ø 9.5 ø12.7 ø15.9
connection 1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
Drain ø16.0 2. Sound pressure levels are measured in an anechoic chamber based on the temperature conditions in 1 above. These are anechoic conversion values. These values are normally somewhat higher
during actual operation as a result of ambient conditions.
Max. piping length 15 30 3. CSPF is based on TCVN 7830: 2015 conditions.
m
Max. level difference 12 20

Measurement conditions
1. Cooling capacity is based on: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; piping length 7.5 m.
3. Sound pressure levels are measured in an anechoic chamber based on the temperature conditions in 1 and 2 above. These values are normally somewhat higher during actual operation as a result of
ambient conditions.
4. CSPF is based on TCVN 7830: 2015 conditions.

49 50
Options
FTKM Series Cooling Only FTKC and ATKC Series Cooling Only
Indoor Unit Indoor Unit
No. Item FTKM25/35 FTKM50/60/71 No. Item FTKC25/35 and ATKC25/35 FTKC50/60/71
1 Titanium apatite deodorising filter *1 1 Titanium apatite deodorising filter *1 KAF970A46
KAF970A46
2 Dust collection filter (PM 2.5) BAFP046A41 2 Dust collection filter (PM 2.5) BAFP046A41
3 Remote controller loss prevention with chain KKF910A4 3 Remote controller loss prevention with chain KKF910A4
4 Daikin mobile controller *2 4 Daikin mobile controller *2 BRP072A42
BRP072A42
5 Remote control PC-board set KRP067A41 KRP980B2 5 Remote control PC-board set KRP067A41 KRP980B2
Notes: *1. The filter is a standard accessory. Notes: *1. The filter is a standard accessory.
*2. A remote control PC-board set (KRP067A41 or KRP980B2) is also required for each indoor unit. *2. A remote control PC-board set (KRP067A41 or KRP980B2) is also required for each indoor unit.

Outdoor Unit Daikin mobile controller BRP072A42


No. Item RKM25/35 RKM50/60/71 Dimensions (H x W x D) 79 x 52 x 17.5 mm
1 Air direction adjustment grille KPW937E4 KPW5E112 Gross weight 40 g
Wireless LAN standard IEEE802.11 b/g/n (2.4 GHz)
2 Drain plug *1 KKP937A4 Accessories Wire harness (1,600 mm), screws (two pieces), double-faced tape,
Note: *1. One set includes five pieces for five units. installation manual

Control System
No. Item FTKM25/35 FTKM50/60/71 Outdoor Unit
1 Central remote controller *1 DCS302CA61 No. Item RKC25/35/50/60/71 and ARKC25/35
2 Unified On/Off controller *1 DCS301BA61 1 Air direction adjustment grille KPW937E4
3 Schedule timer *1 DST301BA61 2 Drain plug *1 KKP937A4
4 Interface adaptor for DIII-NET use *2 KRP928BB2S Note: *1. One set includes five pieces for five units.
5 Remote control PC-board set KRP067A41 KRP980B2
Notes: *1. An interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
*2. A remote control PC-board set (KRP067A41 or KRP980B2) is also required for each indoor unit.
Control System
No. Item FTKC25/35 and ATKC25/35 FTKC50/60/71
1 Central remote controller *1 DCS302CA61

FTXV Series Heat Pump 2


3
Unified On/Off controller
Schedule timer
*1
*1
DCS301BA61
DST301BA61
Indoor Unit 4 Interface adaptor for DIII-NET use *2 KRP928BB2S
No. Item FTXV25/35 FTXV50/60/71 5 Remote control PC-board set KRP067A41 KRP980B2
*3 BRC944B2 *1 BRC944B2 *2
1 Wired remote controller Notes: *1. An interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
BRC073A1 * BRC073A1 * *2. A remote control PC-board set (KRP067A41 or KRP980B2) is also required for each indoor unit.
1 2

Length 3 m (shielded wire) BRCW901A03


2 Wired remote controller cord
Length 8 m (shielded wire) BRCW901A08
3 Titanium apatite deodorising filter *4 KAF970A46
4 Dust collection filter (PM 2.5) BAFP046A41
5 Remote controller loss prevention with chain KKF910A4

FTHF Series
6 Daikin mobile controller BRP072A42 *1 BRP072A42*2
7 Remote control PC-board set
Heat Pump
KRP067A41 KRP980B2
Notes: *1. A remote control PC-board set (KRP067A41) is also required for each indoor unit. Indoor Unit
*2. A remote control PC-board set (KRP980B2) is also required for each indoor unit.
*3. The BRCW901A03 (three metres) or BRCW901A08 (eight metres) wired remote controller cord is also required. No. Item FTHF25/35 FTHF50/60/71
*4. The filter is a standard accessory. 1 Titanium apatite deodorising filter *1 KAF970A46
2 Dust collection filter (PM 2.5) BAFP046A41
Outdoor Unit 3 Remote controller loss prevention with chain KKF917A4 KKF910A4
No. Item RXV25/35 RXV50/60/71 *2
4 Daikin mobile controller BRP072A42
1 Air direction adjustment grille KPW937E4 KPW5E112
5 Remote control PC-board set KRP067A41 KRP980B2
2 Drain plug *1 KKP937A4
Notes: *1. The filter is a standard accessory.
Note: *1. One set includes five pieces for five units. *2. A remote control PC-board set (KRP067A41 or KRP980B2) is also required for each indoor unit.

Control System Outdoor Unit


No. Item FTXV25/35 FTXV50/60/71 No. Item RHF25/35 RHF50/60/71
1 Central remote controller *1 DCS302CA61 1 Air direction adjustment grille KPW937B4 KPW5E112
2 Unified On/Off controller *1 DCS301BA61 2 Drain plug *1 KKP937A4
3 Schedule timer *1 DST301BA61 Note: *1. One set includes five pieces for five units.
4 Interface adaptor for DIII-NET use KRP928BB2S *2 KRP928BB2S *3
5 Remote control PC-board set KRP067A41 KRP980B2
Notes: *1. An interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
*2. A remote control PC-board set (KRP067A41) is also required for each indoor unit.
51 *3. A remote control PC-board set (KRP980B2) is also required for each indoor unit. 52
Options

FTKQ Series Cooling Only


Indoor Unit
No. Item FTKQ25/35/50/60
1 Titanium apatite deodorising filter *1 KAF970A46
2 Remote controller loss prevention with chain KKF910A4
3 Daikin mobile controller *2 BRP072A42
4 Remote control PC-board set KRP067A41
Notes: *1. The filter is a standard accessory.
*2. A remote control PC-board set (KRP067A41) is also required for each indoor unit.

Daikin mobile controller BRP072A42


Dimensions (H x W x D) 79 x 52 x 17.5 mm
Gross weight 40 g
Wireless LAN standard IEEE802.11 b/g/n (2.4 GHz)
Accessories Wire harness (1,600 mm), screws (two pieces), double-faced tape,
installation manual

Outdoor Unit
No. Item RKQ25 RKQ35 RKQ50/60
1 Air direction adjustment grille – KPW937B4 KPW937E4
2 Drain plug *1 KKP937A4
Note: *1. One set includes five pieces for five units.

Control System
No. Item FTKQ25/35/50/60
1 Central remote controller *1 DCS302CA61
2 Unified On/Off controller *1 DCS301BA61
3 Schedule timer *1 DST301BA61
4 Interface adaptor for DIII-NET use *2 KRP928BB2S
5 Remote control PC-board set KRP067A41
Notes: *1. An interface adaptor for DIII-NET use (KRP928BB2S) is also required for each indoor unit.
*2. A remote control PC-board set (KRP067A41) is also required for each indoor unit.

53 54