Professional Documents
Culture Documents
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 1
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
3
4
1800 mm
1
2
y
1800 mm
;
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 2
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
102 mm
500 mm
;
Pile cap details
Pile cap width, along x axis; Lx = 1800 mm
Pile cap width, along y axis; Ly = 1800 mm
Total cap depth; Dcap = 500 mm
Density of concrete; conc = 24 kN/m3
Height of soil above pile cap; hsoil = 0 mm
Density of soil above pile cap; soil = 17 kN/m3
Column details
Column width, along x axis; lx,col = 800 mm
Column width, along y axis; ly,col = 800 mm
Column location, x axis; xc = 900 mm
Column location, y axis; yc = 900 mm
Pile details
Pile material; Concrete
Concrete pile section; Circular
Pile diameter; hpile = 300 mm
Allowable axial compression load; PpC,allow = 662.9 kN
Allowable axial tension load; PpT,allow = 366.7 kN
Allowable lateral load; Vp,allow = 92.9 kN
Number of piles; Np = 4.000
Pile embedment; dembed = 102 mm
Pile number x location (mm) y location (mm)
1 450 450
2 1506 353
3 420 1462
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 3
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
4 1426 1412
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 2.446 MPa
vumod / vn = 0.159
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD1) = 100.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.212 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.768 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.162
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD1) = 93.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.238 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 3.157 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.182
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 14
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Vu / Vn = 0.080
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD3,Pp2,LRFD3,Pp3,LRFD3,Pp4,LRFD3) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 277.1 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs dv2),0 MPa) = 0.334 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2 lx,perim + 2 ly,perim = 5200 mm
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 1.418 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 2.446 MPa
vumod / vn = 0.136
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD3) = 86.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.182 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.768 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 24
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.182 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.768 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.139
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD4) = 80.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.204 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 3.157 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.156
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD4) = 69.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.162 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.968 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 30
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 2677.1 kN
Design shear capacity; Vn = v Vn = 2007.8 kN
Vu / Vn = 0.070
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 130.6 kN
Ultimate moment force at face of column; Mu = 32.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 1515.7 kN
Design shear capacity; Vn = v Vn = 1136.8 kN
Vu / Vn = 0.115
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 119.6 kN
Ultimate moment force at face of column; Mu = 25.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 1622.4 kN
Design shear capacity; Vn = v Vn = 1216.8 kN
Vu / Vn = 0.098
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 151.9 kN
Ultimate moment force at face of column; Mu = 25.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2526.9 kN
Design shear capacity; Vn = v Vn = 1895.1 kN
Vu / Vn = 0.080
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 44
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.164
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 236.5 kN
Ultimate moment force at face of column; Mu = 31.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 2677.1 kN
Design shear capacity; Vn = v Vn = 2007.8 kN
Vu / Vn = 0.118
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 301.6 kN
Ultimate moment force at face of column; Mu = 76.9 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 1464.8 kN
Design shear capacity; Vn = v Vn = 1098.6 kN
Vu / Vn = 0.275
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 182.2 kN
Ultimate moment force at face of column; Mu = 37.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 1651.1 kN
Design shear capacity; Vn = v Vn = 1238.3 kN
Vu / Vn = 0.147
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 356.0 kN
Ultimate moment force at face of column; Mu = 63.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 49
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.768 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.273
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD8) = 203.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.516 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 3.157 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.394
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD8) = 83.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.195 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.968 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 51
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 533.7 kN
Design shear capacity; Vn = v Vn = 400.3 kN
Vu / Vn = 0.209
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD8) = 111.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 535.3 kN
Design shear capacity; Vn = v Vn = 401.5 kN
Vu / Vn = 0.278
PASS - Design shear capacity exceeds ultimate shear load
Combination 9 results: 1.2D + 1.6S + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 49.0 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.118
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 39.9 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 53
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.102
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 117.0 kN
Ultimate moment force at face of column; Mu = 14.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 2677.1 kN
Design shear capacity; Vn = v Vn = 2007.8 kN
Vu / Vn = 0.058
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 190.6 kN
Ultimate moment force at face of column; Mu = 49.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 1448.9 kN
Design shear capacity; Vn = v Vn = 1086.7 kN
Vu / Vn = 0.175
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 87.9 kN
Ultimate moment force at face of column; Mu = 17.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 54
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 1714.5 kN
Design shear capacity; Vn = v Vn = 1285.9 kN
Vu / Vn = 0.068
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 219.7 kN
Ultimate moment force at face of column; Mu = 39.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2526.9 kN
Design shear capacity; Vn = v Vn = 1895.1 kN
Vu / Vn = 0.116
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD9,Pp2,LRFD9,Pp3,LRFD9,Pp4,LRFD9) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 313.4 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs dv2),0 MPa) = 0.377 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2 lx,perim + 2 ly,perim = 5200 mm
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 1.418 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 2.446 MPa
vumod / vn = 0.154
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 55
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 488.4 kN
Design shear capacity; Vn = v Vn = 366.3 kN
Vu / Vn = 0.372
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD9) = 33.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 533.7 kN
Design shear capacity; Vn = v Vn = 400.3 kN
Vu / Vn = 0.084
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD9) = 67.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 535.3 kN
Design shear capacity; Vn = v Vn = 401.5 kN
Vu / Vn = 0.167
PASS - Design shear capacity exceeds ultimate shear load
Combination 10 results: 1.2D + 1.6R + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 49.0 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 459.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 58
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.118
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 39.9 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.102
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 117.0 kN
Ultimate moment force at face of column; Mu = 14.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 2677.1 kN
Design shear capacity; Vn = v Vn = 2007.8 kN
Vu / Vn = 0.058
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 190.6 kN
Ultimate moment force at face of column; Mu = 49.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 59
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 1448.9 kN
Design shear capacity; Vn = v Vn = 1086.7 kN
Vu / Vn = 0.175
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 87.9 kN
Ultimate moment force at face of column; Mu = 17.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 1714.5 kN
Design shear capacity; Vn = v Vn = 1285.9 kN
Vu / Vn = 0.068
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 219.7 kN
Ultimate moment force at face of column; Mu = 39.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2526.9 kN
Design shear capacity; Vn = v Vn = 1895.1 kN
Vu / Vn = 0.116
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD10,Pp2,LRFD10,Pp3,LRFD10,Pp4,LRFD10) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 313.4 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs dv2),0 MPa) = 0.377 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2 lx,perim + 2 ly,perim = 5200 mm
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.00
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 60
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 535.3 kN
Design shear capacity; Vn = v Vn = 401.5 kN
Vu / Vn = 0.212
PASS - Design shear capacity exceeds ultimate shear load
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2526.9 kN
Design shear capacity; Vn = v Vn = 1895.1 kN
Vu / Vn = 0.152
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD12,Pp2,LRFD12,Pp3,LRFD12,Pp4,LRFD12) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 349.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs dv2),0 MPa) = 0.421 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2 lx,perim + 2 ly,perim = 5200 mm
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 1.418 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 2.446 MPa
vumod / vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD12) = 110.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.233 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.768 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 71
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 1917.6 kN
Design shear capacity; Vn = v Vn = 1438.2 kN
Vu / Vn = 0.039
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 287.5 kN
Ultimate moment force at face of column; Mu = 54.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2526.9 kN
Design shear capacity; Vn = v Vn = 1895.1 kN
Vu / Vn = 0.152
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD13,Pp2,LRFD13,Pp3,LRFD13,Pp4,LRFD13) - 1.2 (conc Dcap)
(Acap - AInsidePerim)) = 349.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs dv2),0 MPa) = 0.421 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2 lx,perim + 2 ly,perim = 5200 mm
Column geometry factor (11.11.2.1); = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 1.418 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 2.446 MPa
vumod / vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 76
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 488.4 kN
Design shear capacity; Vn = v Vn = 366.3 kN
Vu / Vn = 0.525
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD13) = 2.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 533.7 kN
Design shear capacity; Vn = v Vn = 400.3 kN
Vu / Vn = 0.005
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD13) = 71.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17 (f'c 1 MPa) b dv2 = 535.3 kN
Design shear capacity; Vn = v Vn = 401.5 kN
Vu / Vn = 0.177
PASS - Design shear capacity exceeds ultimate shear load
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 413.9 kNm
Mu / Mn = 0.272
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 85.2 kNm
Tension reinforcement provided; (12) 19 mm bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Lx Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 389.5 kNm
Mu / Mn = 0.219
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 20.4 kNm
Tension reinforcement provided; (12) 19 mm top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018 Ly Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3 Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov fy / (0.85 f'c Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003 d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov fy (d - a / 2) = 605.6 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002) (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f Mn = 545.1 kNm
Mu / Mn = 0.037
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 80
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance))) (bo / bs) vcp, 32 (f'c
1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn.col.mod = 2.446 MPa
vumod / vn = 0.156
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD14) = 77.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.163 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 2.768 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.125
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD14) = 351.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo dv2),0 MPa) = 0.893 MPa
Pile geometry factor (11.11.2.1); = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17 (1 + 2 / ) (f'c 1 MPa) = 2.699 MPa
vcpb = 0.083 (s dv2 / bo + 2) (f'c 1 MPa) = 3.157 MPa
vcpc = 0.33 (f'c 1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v vn = 1.310 MPa
vug / vn = 0.682
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 83
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 2677.1 kN
Design shear capacity; Vn = v Vn = 2007.8 kN
Vu / Vn = 0.085
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 360.0 kN
Ultimate moment force at face of column; Mu = 98.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Ly dv = 1344.8 kN
Design shear capacity; Vn = v Vn = 1008.6 kN
Vu / Vn = 0.357
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 156.1 kN
Ultimate moment force at face of column; Mu = 40.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 1294.4 kN
Design shear capacity; Vn = v Vn = 970.8 kN
Vu / Vn = 0.161
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 344.5 kN
Ultimate moment force at face of column; Mu = 73.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance)) (3.5 - 2.5 min(1.0,Mu / (Vu dv))) (1.9
(f'c 1 psi) + 0.1 (f'c 1 psi) max(1.0,Vu dv / Mu)),10
(f'c 1 psi)) Lx dv = 2384.6 kN
Design shear capacity; Vn = v Vn = 1788.4 kN
Vu / Vn = 0.193
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 93
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018
1800 mm
;
;