You are on page 1of 96

Project Job Ref.

N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 1
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PILE CAP ANALYSIS & DESIGN (ACI318-11)


In accordance with ACI318-11
Tedds calculation version 2.0.00

Pile analysis summary


Unit Applied Allowable Utilization Result
Pile axial compression, pile 2 kN 257 663 0.388 PASS
Pile axial tension, pile 3 kN 142 367 0.388 PASS
Pile cap design summary
Unit Required Provided Utilization Result
Flexural reinforcement mm2 1620 (min) 3402 0.476 PASS
One way modified shear kN 419 1026 0.408 PASS
Two way col. mod. shear MPa 0.657 2.446 0.269 PASS
Two way pile shear MPa 0.893 1.310 0.682 PASS
One way corner pile shear kN 352 366 0.96 PASS

3
4
1800 mm

1
2
y

1800 mm

;
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 2
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

102 mm
500 mm

;
Pile cap details
Pile cap width, along x axis; Lx = 1800 mm
Pile cap width, along y axis; Ly = 1800 mm
Total cap depth; Dcap = 500 mm
Density of concrete; conc = 24 kN/m3
Height of soil above pile cap; hsoil = 0 mm
Density of soil above pile cap; soil = 17 kN/m3

Column details
Column width, along x axis; lx,col = 800 mm
Column width, along y axis; ly,col = 800 mm
Column location, x axis; xc = 900 mm
Column location, y axis; yc = 900 mm
Pile details
Pile material; Concrete
Concrete pile section; Circular
Pile diameter; hpile = 300 mm
Allowable axial compression load; PpC,allow = 662.9 kN
Allowable axial tension load; PpT,allow = 366.7 kN
Allowable lateral load; Vp,allow = 92.9 kN
Number of piles; Np = 4.000
Pile embedment; dembed = 102 mm
Pile number x location (mm) y location (mm)
1 450 450
2 1506 353
3 420 1462
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 3
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

4 1426 1412

Column axial loads


Axial dead load; PD = 210.6 kN
Total area axial dead load; PD,area = conc  Lx  Ly  Dcap = 38.9 kN
Axial rooflive load; PLr = 145.1 kN
Axial wind load; PW = 72.6 kN
Axial seismic load; PE = 11.7 kN
Column shear loads
Shear dead load, along x axis; VxD = 0.8 kN
Shear rooflive load, along x axis; VxLr = 0.6 kN
Shear wind load, along x axis; VxW = 12.2 kN
Shear seismic load, along x axis; VxE = 32.8 kN
Shear dead load, along y axis; VyD = 3.4 kN
Shear rooflive load, along y axis; VyLr = 3.5 kN
Shear wind load, along y axis; VyW = 15.4 kN
Shear seismic load, along y axis; VyE = 36.9 kN
Column moment loads
Moment dead load, about x-x axis; MxD = 12.9 kNm
Moment rooflive load, about x-x axis; MxLr = 13.4 kNm
Moment wind load, about x-x axis; MxW = 106.0 kNm
Moment seismic load, about x-x axis; MxE = 253.7 kNm
Moment dead load, about y-y axis; MyD = 3.9 kNm
Moment rooflive load, about y-y axis; MyLr = 2.8 kNm
Moment wind load, about y-y axis; MyW = 77.1 kNm
Moment seismic load, about y-y axis; MyE = 246.4 kNm
Pile group centroid
Centroid location, x direction; xpg,c = (xp1 + xp2 + xp3 + xp4) / Np = 951 mm
Centroid location, y direction; ypg,c = (yp1 + yp2 + yp3 + yp4) / Np = 919 mm
Pile distance from centroid
Pile 1 centroid distance, x direction; xp1,c = xp1 - xpg,c = -501 mm
Pile 1 centroid distance, y direction; yp1,c = yp1 - ypg,c = -469 mm
Pile 2 centroid distance, x direction; xp2,c = xp2 - xpg,c = 556 mm
Pile 2 centroid distance, y direction; yp2,c = yp2 - ypg,c = -566 mm
Pile 3 centroid distance, x direction; xp3,c = xp3 - xpg,c = -531 mm
Pile 3 centroid distance, y direction; yp3,c = yp3 - ypg,c = 543 mm
Pile 4 centroid distance, x direction; xp4,c = xp4 - xpg,c = 476 mm
Pile 4 centroid distance, y direction; yp4,c = yp4 - ypg,c = 493 mm
Moment of inertia of pile group
Moment of inertia about x-x axis; Ixx = yp1,c2 + yp2,c2 + yp3,c2 + yp4,c2 = 1077971 mm2
Moment of inertia about y-y axis; Iyy = xp1,c2 + xp2,c2 + xp3,c2 + xp4,c2 = 1067423 mm2
Loading eccentricity
Eccentricity of column load, x direction; ex,c = xc - xpg,c = -51 mm
Eccentricity of column load, y direction; ey,c = yc - ypg,c = -19 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 4
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Dead load pile forces


Dead load moment about x-x axis; MxD,Des = MxD + (-1)  PD  ey,c + (-1)  VyD  Dcap = 15.2 kNm
Dead load moment about y-y axis; MyD,Des = MyD + PD  ex,c + VxD  Dcap = -6.4 kNm
Dead axial load on pile 1; Pp1,D = (PD + PD,area) / Np + MyD,Des  xp1,c / Iyy + MxD,Des  (-1)  yp1,c / Ixx = 72
kN
Dead axial load on pile 2; Pp2,D = (PD + PD,area) / Np + MyD,Des  xp2,c / Iyy + MxD,Des  (-1)  yp2,c / Ixx = 67
kN
Dead axial load on pile 3; Pp3,D = (PD + PD,area) / Np + MyD,Des  xp3,c / Iyy + MxD,Des  (-1)  yp3,c / Ixx = 58
kN
Dead axial load on pile 4; Pp4,D = (PD + PD,area) / Np + MyD,Des  xp4,c / Iyy + MxD,Des  (-1)  yp4,c / Ixx = 53
kN

RoofLive load pile forces


RoofLive load moment about x-x axis; MxLr,Des = MxLr + (-1)  PLr  ey,c + (-1)  VyLr  Dcap = 14.4 kNm
RoofLive load moment about y-y axis; MyLr,Des = MyLr + PLr  ex,c + VxLr  Dcap = -4.3 kNm
RoofLive axial load on pile 1; Pp1,Lr = PLr / Np + MyLr,Des  xp1,c / Iyy + MxLr,Des  (-1)  yp1,c / Ixx = 45 kN
RoofLive axial load on pile 2; Pp2,Lr = PLr / Np + MyLr,Des  xp2,c / Iyy + MxLr,Des  (-1)  yp2,c / Ixx = 42 kN
RoofLive axial load on pile 3; Pp3,Lr = PLr / Np + MyLr,Des  xp3,c / Iyy + MxLr,Des  (-1)  yp3,c / Ixx = 31 kN
RoofLive axial load on pile 4; Pp4,Lr = PLr / Np + MyLr,Des  xp4,c / Iyy + MxLr,Des  (-1)  yp4,c / Ixx = 28 kN

Wind load pile forces


Wind load moment about x-x axis; MxW,Des = MxW + (-1)  PW  ey,c + (-1)  VyW  Dcap = 99.7 kNm
Wind load moment about y-y axis; MyW,Des = MyW + PW  ex,c + VxW  Dcap = 79.5 kNm
Wind axial load on pile 1; Pp1,W = PW / Np + MyW,Des  xp1,c / Iyy + MxW,Des  (-1)  yp1,c / Ixx = 24 kN
Wind axial load on pile 2; Pp2,W = PW / Np + MyW,Des  xp2,c / Iyy + MxW,Des  (-1)  yp2,c / Ixx = 112 kN
Wind axial load on pile 3; Pp3,W = PW / Np + MyW,Des  xp3,c / Iyy + MxW,Des  (-1)  yp3,c / Ixx = -72 kN
Wind axial load on pile 4; Pp4,W = PW / Np + MyW,Des  xp4,c / Iyy + MxW,Des  (-1)  yp4,c / Ixx = 8 kN

Seismic load pile forces


Seismic load moment about x-x axis; MxE,Des = MxE + (-1)  PE  ey,c + (-1)  VyE  Dcap = 235.4 kNm
Seismic load moment about y-y axis; MyE,Des = MyE + PE  ex,c + VxE  Dcap = 262.2 kNm
Seismic axial load on pile 1; Pp1,E = PE / Np + MyE,Des  xp1,c / Iyy + MxE,Des  (-1)  yp1,c / Ixx = -18 kN
Seismic axial load on pile 2; Pp2,E = PE / Np + MyE,Des  xp2,c / Iyy + MxE,Des  (-1)  yp2,c / Ixx = 263 kN
Seismic axial load on pile 3; Pp3,E = PE / Np + MyE,Des  xp3,c / Iyy + MxE,Des  (-1)  yp3,c / Ixx = -246 kN
Seismic axial load on pile 4; Pp4,E = PE / Np + MyE,Des  xp4,c / Iyy + MxE,Des  (-1)  yp4,c / Ixx = 12 kN

ASCE 7-10 load combinations (ASD)


1.0D (0.109)
1.0D + 1.0L (0.109)
1.0D + 1.0Lr (0.176)
1.0D + 1.0S (0.109)
1.0D + 1.0R (0.109)
1.0D + 0.75L + 0.75Lr (0.159)
1.0D + 0.75L + 0.75S (0.109)
1.0D + 0.75L + 0.75R (0.109)
1.0D + 0.6W (0.202)
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 5
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

(1.0 + 0.14SDS)D + 0.7E (0.388)


1.0D + 0.75L + 0.75Lr + 0.45W (0.224)
1.0D + 0.75L + 0.75S + 0.45W (0.177)
1.0D + 0.75L + 0.75R + 0.45W (0.177)
(1.0 + 0.10SDS)D + 0.75L + 0.75S + 0.525E (0.316)
0.6D + 0.6W (0.162)
(0.6 - 0.14SDS)D + 0.7E (0.388)

Combination 1 results: 1.0D


Pile 1 axial load; Pp1 = 1.0  Pp1,D = 72 kN
max(Pp1 / PpC,allow,0) = 0.109
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D = 67 kN
max(Pp2 / PpC,allow,0) = 0.101
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D = 57.9 kN
max(Pp3 / PpC,allow,0) = 0.087
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D = 52.6 kN
max(Pp4 / PpC,allow,0) = 0.079
PASS - Pile allowable compression load exceeds axial force
Combination 2 results: 1.0D + 1.0L
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,L = 72 kN
max(Pp1 / PpC,allow,0) = 0.109
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,L = 67 kN
max(Pp2 / PpC,allow,0) = 0.101
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,L = 57.9 kN
max(Pp3 / PpC,allow,0) = 0.087
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,L = 52.6 kN
max(Pp4 / PpC,allow,0) = 0.079
PASS - Pile allowable compression load exceeds axial force
Combination 3 results: 1.0D + 1.0Lr
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,Lr = 116.5 kN
max(Pp1 / PpC,allow,0) = 0.176
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,Lr = 108.7 kN
max(Pp2 / PpC,allow,0) = 0.164
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,Lr = 89 kN
max(Pp3 / PpC,allow,0) = 0.134
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,Lr = 80.4 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 6
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

max(Pp4 / PpC,allow,0) = 0.121


PASS - Pile allowable compression load exceeds axial force
Combination 4 results: 1.0D + 1.0S
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,S = 72 kN
max(Pp1 / PpC,allow,0) = 0.109
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,S = 67 kN
max(Pp2 / PpC,allow,0) = 0.101
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,S = 57.9 kN
max(Pp3 / PpC,allow,0) = 0.087
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,S = 52.6 kN
max(Pp4 / PpC,allow,0) = 0.079
PASS - Pile allowable compression load exceeds axial force
Combination 5 results: 1.0D + 1.0R
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 1.0  Pp1,R = 72 kN
max(Pp1 / PpC,allow,0) = 0.109
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 1.0  Pp2,R = 67 kN
max(Pp2 / PpC,allow,0) = 0.101
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 1.0  Pp3,R = 57.9 kN
max(Pp3 / PpC,allow,0) = 0.087
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 1.0  Pp4,R = 52.6 kN
max(Pp4 / PpC,allow,0) = 0.079
PASS - Pile allowable compression load exceeds axial force
Combination 6 results: 1.0D + 0.75L + 0.75Lr
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,Lr = 105.4 kN
max(Pp1 / PpC,allow,0) = 0.159
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,Lr = 98.2 kN
max(Pp2 / PpC,allow,0) = 0.148
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,Lr = 81.3 kN
max(Pp3 / PpC,allow,0) = 0.123
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,Lr = 73.4 kN
max(Pp4 / PpC,allow,0) = 0.111
PASS - Pile allowable compression load exceeds axial force
Combination 7 results: 1.0D + 0.75L + 0.75S
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,S = 72 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 7
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

max(Pp1 / PpC,allow,0) = 0.109


PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,S = 67 kN
max(Pp2 / PpC,allow,0) = 0.101
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,S = 57.9 kN
max(Pp3 / PpC,allow,0) = 0.087
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,S = 52.6 kN
max(Pp4 / PpC,allow,0) = 0.079
PASS - Pile allowable compression load exceeds axial force
Combination 8 results: 1.0D + 0.75L + 0.75R
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,R = 72 kN
max(Pp1 / PpC,allow,0) = 0.109
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,R = 67 kN
max(Pp2 / PpC,allow,0) = 0.101
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,R = 57.9 kN
max(Pp3 / PpC,allow,0) = 0.087
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,R = 52.6 kN
max(Pp4 / PpC,allow,0) = 0.079
PASS - Pile allowable compression load exceeds axial force
Combination 9 results: 1.0D + 0.6W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.6  Pp1,W = 86.5 kN
max(Pp1 / PpC,allow,0) = 0.130
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.6  Pp2,W = 134.2 kN
max(Pp2 / PpC,allow,0) = 0.202
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.6  Pp3,W = 14.9 kN
max(Pp3 / PpC,allow,0) = 0.023
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.6  Pp4,W = 57.4 kN
max(Pp4 / PpC,allow,0) = 0.087
PASS - Pile allowable compression load exceeds axial force

Combination 10 results: (1.0 + 0.14SDS)D + 0.7E


Pile 1 axial load; Pp1 = 1.085  Pp1,D + 0.7  Pp1,E = 65.8 kN
max(Pp1 / PpC,allow,0) = 0.099
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.085  Pp2,D + 0.7  Pp2,E = 256.9 kN
max(Pp2 / PpC,allow,0) = 0.388
PASS - Pile allowable compression load exceeds axial force
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 8
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile 3 axial load; Pp3 = 1.085  Pp3,D + 0.7  Pp3,E = -109.4 kN


max(Pp3 / (-1  PpT,allow),0) = 0.298
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 1.085  Pp4,D + 0.7  Pp4,E = 65.6 kN
max(Pp4 / PpC,allow,0) = 0.099
PASS - Pile allowable compression load exceeds axial force
Combination 11 results: 1.0D + 0.75L + 0.75Lr + 0.45W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,Lr + 0.45  Pp1,W = 116.3 kN
max(Pp1 / PpC,allow,0) = 0.175
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,Lr + 0.45  Pp2,W = 148.6 kN
max(Pp2 / PpC,allow,0) = 0.224
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,Lr + 0.45  Pp3,W = 49 kN
max(Pp3 / PpC,allow,0) = 0.074
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,Lr + 0.45  Pp4,W = 77.1 kN
max(Pp4 / PpC,allow,0) = 0.116
PASS - Pile allowable compression load exceeds axial force
Combination 12 results: 1.0D + 0.75L + 0.75S + 0.45W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,S + 0.45  Pp1,W = 82.9 kN
max(Pp1 / PpC,allow,0) = 0.125
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,S + 0.45  Pp2,W = 117.4 kN
max(Pp2 / PpC,allow,0) = 0.177
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,S + 0.45  Pp3,W = 25.7 kN
max(Pp3 / PpC,allow,0) = 0.039
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,S + 0.45  Pp4,W = 56.2 kN
max(Pp4 / PpC,allow,0) = 0.085
PASS - Pile allowable compression load exceeds axial force
Combination 13 results: 1.0D + 0.75L + 0.75R + 0.45W
Pile 1 axial load; Pp1 = 1.0  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,R + 0.45  Pp1,W = 82.9 kN
max(Pp1 / PpC,allow,0) = 0.125
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.0  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,R + 0.45  Pp2,W = 117.4 kN
max(Pp2 / PpC,allow,0) = 0.177
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.0  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,R + 0.45  Pp3,W = 25.7 kN
max(Pp3 / PpC,allow,0) = 0.039
PASS - Pile allowable compression load exceeds axial force
Pile 4 axial load; Pp4 = 1.0  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,R + 0.45  Pp4,W = 56.2 kN
max(Pp4 / PpC,allow,0) = 0.085
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 9
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Pile allowable compression load exceeds axial force

Combination 14 results: (1.0 + 0.10SDS)D + 0.75L + 0.75S + 0.525E


Pile 1 axial load; Pp1 = 1.06  Pp1,D + 0.75  Pp1,L + 0.75  Pp1,S + 0.525  Pp1,E = 67.1 kN
max(Pp1 / PpC,allow,0) = 0.101
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 1.06  Pp2,D + 0.75  Pp2,L + 0.75  Pp2,S + 0.525  Pp2,E = 209.2 kN
max(Pp2 / PpC,allow,0) = 0.316
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 1.06  Pp3,D + 0.75  Pp3,L + 0.75  Pp3,S + 0.525  Pp3,E = -67.8 kN
max(Pp3 / (-1  PpT,allow),0) = 0.185
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 1.06  Pp4,D + 0.75  Pp4,L + 0.75  Pp4,S + 0.525  Pp4,E = 62.1 kN
max(Pp4 / PpC,allow,0) = 0.094
PASS - Pile allowable compression load exceeds axial force
Combination 15 results: 0.6D + 0.6W
Pile 1 axial load; Pp1 = 0.6  Pp1,D + 0.6  Pp1,W = 57.7 kN
max(Pp1 / PpC,allow,0) = 0.087
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 0.6  Pp2,D + 0.6  Pp2,W = 107.4 kN
max(Pp2 / PpC,allow,0) = 0.162
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 0.6  Pp3,D + 0.6  Pp3,W = -8.2 kN
max(Pp3 / (-1  PpT,allow),0) = 0.022
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 0.6  Pp4,D + 0.6  Pp4,W = 36.4 kN
max(Pp4 / PpC,allow,0) = 0.055
PASS - Pile allowable compression load exceeds axial force

Combination 16 results: (0.6 - 0.14SDS)D + 0.7E


Pile 1 axial load; Pp1 = 0.515  Pp1,D + 0.7  Pp1,E = 24.8 kN
max(Pp1 / PpC,allow,0) = 0.037
PASS - Pile allowable compression load exceeds axial force
Pile 2 axial load; Pp2 = 0.515  Pp2,D + 0.7  Pp2,E = 218.7 kN
max(Pp2 / PpC,allow,0) = 0.330
PASS - Pile allowable compression load exceeds axial force
Pile 3 axial load; Pp3 = 0.515  Pp3,D + 0.7  Pp3,E = -142.4 kN
max(Pp3 / (-1  PpT,allow),0) = 0.388
PASS - Pile allowable tension load exceeds axial force
Pile 4 axial load; Pp4 = 0.515  Pp4,D + 0.7  Pp4,E = 35.6 kN
max(Pp4 / PpC,allow,0) = 0.054
PASS - Pile allowable compression load exceeds axial force
Pile cap design
Material details
Compressive strength of concrete; f'c = 28.000 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 10
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Concrete type; Normal weight


Concrete modification factor; =1
Yield strength of reinforcement; fy = 420.000 MPa
Nominal cover to top reinforcement; cnom,top = 50 mm
Nominal cover to bottom reinforcement; cnom,bot = 50 mm
ASCE 7-10 load combinations (LRFD)
1.4D (0.476)
1.2D + 1.6L + 0.5Lr (0.476)
1.2D + 1.6L + 1  0.5S (0.476)
1.2D + 1.6L + 0.5R (0.476)
1.2D + 1.0L + 1.6Lr (0.476)
1.2D + 1.0L + 1.6S (0.476)
1.2D + 1.0L + 1.6R (0.476)
1.2D + 1.6Lr + 0.5W (0.554)
1.2D + 1.6S + 0.5W (0.476)
1.2D + 1.6R + 0.5W (0.476)
1.2D + 1.0L + 0.5Lr + 1.0W (0.582)
1.2D + 1.0L + 1  0.5S + 1.0W (0.525)
1.2D + 1.0L + 0.5R + 1.0W (0.525)
(1.2 + 0.2  SDS)D + 1.0L + 1  0.2S + 1.0E (0.960)
0.9D + 1.0W (0.476)
(0.9 - 0.2  SDS)D + 1.0E (0.861)

Combination 1 results: 1.4D


Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 37.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.091
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 11
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Moment design, about x-x axis, positive moment


Ultimate bending moment; Mu = 30.1 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 164.4 kN
Ultimate moment force at face of column; Mu = 21.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.082
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 152.4 kN
Ultimate moment force at face of column; Mu = 37.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1515.7 kN
Design shear capacity; Vn = v  Vn = 1136.8 kN
Vu / Vn = 0.134
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 12
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, top side


Ultimate shear force at face of column; Vu = 139.6 kN
Ultimate moment force at face of column; Mu = 29.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1622.4 kN
Design shear capacity; Vn = v  Vn = 1216.8 kN
Vu / Vn = 0.115
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 177.2 kN
Ultimate moment force at face of column; Mu = 30.1 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.094
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD1,Pp2,LRFD1,Pp3,LRFD1,Pp4,LRFD1) - 1.4  (conc  Dcap) 
(Acap - AInsidePerim)) = 323.3 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.389 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 13
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.159
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD1) = 100.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.212 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.162
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD1) = 93.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.238 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.182
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 14
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 3


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD1) = 81.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.189 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.144
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD1) = 73.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.171 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.131
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD1) = 100.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 15
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear capacity; Vn = v  Vn = 443.6 kN


Vu / Vn = 0.227
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD1) = 93.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.256
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD1) = 81.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.203
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD1) = 73.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.183
PASS - Design shear capacity exceeds ultimate shear load
Combination 2 results: 1.2D + 1.6L + 0.5Lr
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 41.1 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 16
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm


Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.099
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 33.3 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.085
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 178.3 kN
Ultimate moment force at face of column; Mu = 23.9 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.089
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 165.3 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 17
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate moment force at face of column; Mu = 41.1 kNm


Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1510.7 kN
Design shear capacity; Vn = v  Vn = 1133.0 kN
Vu / Vn = 0.146
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 149.1 kN
Ultimate moment force at face of column; Mu = 31.6 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1616.5 kN
Design shear capacity; Vn = v  Vn = 1212.4 kN
Vu / Vn = 0.123
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 194.5 kN
Ultimate moment force at face of column; Mu = 33.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.103
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 18
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear load; Vu = abs(Sum(Pp1,LRFD2,Pp2,LRFD2,Pp3,LRFD2,Pp4,LRFD2) - 1.2  (conc  Dcap) 


(Acap - AInsidePerim)) = 349.6 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.421 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD2) = 108.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.229 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.175
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD2) = 101.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.257 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 19
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile location factor (11.11.2.1); s =20


Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.196
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD2) = 85.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.198 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.151
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD2) = 77.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.179 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 20
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa


vug / vn = 0.137
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD2) = 108.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.245
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD2) = 101.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.276
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD2) = 85.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.212
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD2) = 77.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.192
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 21
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Combination 3 results: 1.2D + 1.6L + 1  0.5S

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 32.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.078
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 25.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.066
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 141.0 kN
Ultimate moment force at face of column; Mu = 18.7 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 22
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm


Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.070
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 130.6 kN
Ultimate moment force at face of column; Mu = 32.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1515.7 kN
Design shear capacity; Vn = v  Vn = 1136.8 kN
Vu / Vn = 0.115
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 119.6 kN
Ultimate moment force at face of column; Mu = 25.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1622.4 kN
Design shear capacity; Vn = v  Vn = 1216.8 kN
Vu / Vn = 0.098
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 151.9 kN
Ultimate moment force at face of column; Mu = 25.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 23
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Vu / Vn = 0.080
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD3,Pp2,LRFD3,Pp3,LRFD3,Pp4,LRFD3) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 277.1 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.334 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.136
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD3) = 86.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.182 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 24
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vug / vn = 0.139


PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD3) = 80.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.204 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.156
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD3) = 69.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.162 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.124
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 25
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear load; Vu = abs(Pp4,LRFD3) = 63.1 kN


Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD3) = 86.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.195
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD3) = 80.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.220
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD3) = 69.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.174
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 26
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 4


Ultimate shear force; Vu = abs(Pp4,LRFD3) = 63.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Combination 4 results: 1.2D + 1.6L + 0.5R
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 32.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.078
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 25.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 27
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134


PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.066
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 141.0 kN
Ultimate moment force at face of column; Mu = 18.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.070
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 130.6 kN
Ultimate moment force at face of column; Mu = 32.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1515.7 kN
Design shear capacity; Vn = v  Vn = 1136.8 kN
Vu / Vn = 0.115
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 119.6 kN
Ultimate moment force at face of column; Mu = 25.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1622.4 kN
Design shear capacity; Vn = v  Vn = 1216.8 kN
Vu / Vn = 0.098
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 28
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, bottom side


Ultimate shear force at face of column; Vu = 151.9 kN
Ultimate moment force at face of column; Mu = 25.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.080
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD4,Pp2,LRFD4,Pp3,LRFD4,Pp4,LRFD4) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 277.1 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.334 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.136
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD4) = 86.4 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 29
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.182 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.139
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD4) = 80.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.204 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.156
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD4) = 69.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.162 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 30
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.124
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD4) = 63.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD4) = 86.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.195
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD4) = 80.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.220
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 31
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 3


Ultimate shear force; Vu = abs(Pp3,LRFD4) = 69.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.174
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD4) = 63.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Combination 5 results: 1.2D + 1.0L + 1.6Lr
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 60.3 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.146
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 49.8 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 32
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)


Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.128
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 260.4 kN
Ultimate moment force at face of column; Mu = 35.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.130
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 241.7 kN
Ultimate moment force at face of column; Mu = 60.3 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1504.8 kN
Design shear capacity; Vn = v  Vn = 1128.6 kN
Vu / Vn = 0.214
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 213.9 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 33
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate moment force at face of column; Mu = 45.5 kNm


Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1609.3 kN
Design shear capacity; Vn = v  Vn = 1206.9 kN
Vu / Vn = 0.177
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 288.2 kN
Ultimate moment force at face of column; Mu = 49.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.152
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD5,Pp2,LRFD5,Pp3,LRFD5,Pp4,LRFD5) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 509.2 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.613 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 34
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa


Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.251
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD5) = 157.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.332 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.254
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD5) = 147.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.374 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.285
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 35
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter width; ly,perim = 631 mm


Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD5) = 119.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.278 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.212
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD5) = 107.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.250 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.191
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD5) = 157.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.355
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 36
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 2


Ultimate shear force; Vu = abs(Pp2,LRFD5) = 147.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.401
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD5) = 119.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.298
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD5) = 107.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.268
PASS - Design shear capacity exceeds ultimate shear load
Combination 6 results: 1.2D + 1.0L + 1.6S
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 32.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 37
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278


PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.078
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 25.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.066
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 141.0 kN
Ultimate moment force at face of column; Mu = 18.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.070
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 130.6 kN
Ultimate moment force at face of column; Mu = 32.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 38
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1515.7 kN
Design shear capacity; Vn = v  Vn = 1136.8 kN
Vu / Vn = 0.115
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 119.6 kN
Ultimate moment force at face of column; Mu = 25.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1622.4 kN
Design shear capacity; Vn = v  Vn = 1216.8 kN
Vu / Vn = 0.098
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 151.9 kN
Ultimate moment force at face of column; Mu = 25.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.080
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD6,Pp2,LRFD6,Pp3,LRFD6,Pp4,LRFD6) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 277.1 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.334 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 39
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00


Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.136
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD6) = 86.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.182 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.139
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD6) = 80.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.204 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 40
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa


Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.156
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD6) = 69.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.162 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.124
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD6) = 63.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 41
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way corner pile shear design, pile 1


Ultimate shear force; Vu = abs(Pp1,LRFD6) = 86.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.195
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD6) = 80.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.220
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD6) = 69.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.174
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD6) = 63.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Combination 7 results: 1.2D + 1.0L + 1.6R
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 32.4 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 42
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)


Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.078
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 25.8 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.066
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 141.0 kN
Ultimate moment force at face of column; Mu = 18.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 43
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.070
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 130.6 kN
Ultimate moment force at face of column; Mu = 32.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1515.7 kN
Design shear capacity; Vn = v  Vn = 1136.8 kN
Vu / Vn = 0.115
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 119.6 kN
Ultimate moment force at face of column; Mu = 25.3 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1622.4 kN
Design shear capacity; Vn = v  Vn = 1216.8 kN
Vu / Vn = 0.098
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 151.9 kN
Ultimate moment force at face of column; Mu = 25.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.080
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 44
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Column modified two way shear design


Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD7,Pp2,LRFD7,Pp3,LRFD7,Pp4,LRFD7) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 277.1 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.334 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.136
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD7) = 86.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.182 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.139
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 45
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 2


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD7) = 80.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.204 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.156
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD7) = 69.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.162 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.124
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD7) = 63.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.147 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 46
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00


Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.112
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD7) = 86.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.195
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD7) = 80.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.220
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD7) = 69.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.174
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD7) = 63.1 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 47
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm


Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.157
PASS - Design shear capacity exceeds ultimate shear load
Combination 8 results: 1.2D + 1.6Lr + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 76.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.186
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 63.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 48
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.164
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 236.5 kN
Ultimate moment force at face of column; Mu = 31.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.118
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 301.6 kN
Ultimate moment force at face of column; Mu = 76.9 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1464.8 kN
Design shear capacity; Vn = v  Vn = 1098.6 kN
Vu / Vn = 0.275
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 182.2 kN
Ultimate moment force at face of column; Mu = 37.8 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1651.1 kN
Design shear capacity; Vn = v  Vn = 1238.3 kN
Vu / Vn = 0.147
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 356.0 kN
Ultimate moment force at face of column; Mu = 63.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 49
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm


Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.188
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD8,Pp2,LRFD8,Pp3,LRFD8,Pp4,LRFD8) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 545.5 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.657 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.269
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD8) = 169.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.358 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 50
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.273
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD8) = 203.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.516 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.394
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD8) = 83.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.195 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 51
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vug / vn = 0.149


PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD8) = 111.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.259 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.198
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD8) = 169.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.383
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD8) = 203.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.554
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD8) = 83.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 52
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.209
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD8) = 111.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.278
PASS - Design shear capacity exceeds ultimate shear load
Combination 9 results: 1.2D + 1.6S + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 49.0 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.118
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 39.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 53
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.102
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 117.0 kN
Ultimate moment force at face of column; Mu = 14.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.058
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 190.6 kN
Ultimate moment force at face of column; Mu = 49.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1448.9 kN
Design shear capacity; Vn = v  Vn = 1086.7 kN
Vu / Vn = 0.175
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 87.9 kN
Ultimate moment force at face of column; Mu = 17.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 54
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1714.5 kN
Design shear capacity; Vn = v  Vn = 1285.9 kN
Vu / Vn = 0.068
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 219.7 kN
Ultimate moment force at face of column; Mu = 39.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.116
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD9,Pp2,LRFD9,Pp3,LRFD9,Pp4,LRFD9) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 313.4 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.377 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.154
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 55
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 1


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD9) = 98.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.207 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.158
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD9) = 136.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.347 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.265
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD9) = 33.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.078 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 56
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00


Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.060
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD9) = 67.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.156 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.119
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD9) = 98.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.222
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD9) = 136.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 57
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.372
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD9) = 33.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.084
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD9) = 67.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.167
PASS - Design shear capacity exceeds ultimate shear load
Combination 10 results: 1.2D + 1.6R + 0.5W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 49.0 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 58
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.118
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 39.9 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.102
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 117.0 kN
Ultimate moment force at face of column; Mu = 14.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.058
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 190.6 kN
Ultimate moment force at face of column; Mu = 49.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 59
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1448.9 kN
Design shear capacity; Vn = v  Vn = 1086.7 kN
Vu / Vn = 0.175
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 87.9 kN
Ultimate moment force at face of column; Mu = 17.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1714.5 kN
Design shear capacity; Vn = v  Vn = 1285.9 kN
Vu / Vn = 0.068
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 219.7 kN
Ultimate moment force at face of column; Mu = 39.9 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.116
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD10,Pp2,LRFD10,Pp3,LRFD10,Pp4,LRFD10) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 313.4 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.377 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 60
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Column location factor (11.11.2.1); s =20


Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.154
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD10) = 98.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.207 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.158
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD10) = 136.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.347 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 61
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.265
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD10) = 33.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.078 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.060
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD10) = 67.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.156 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.119
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD10) = 98.5 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 62
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm


Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.222
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD10) = 136.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.372
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD10) = 33.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.084
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD10) = 67.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.167
PASS - Design shear capacity exceeds ultimate shear load
Combination 11 results: 1.2D + 1.0L + 0.5Lr + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 74.4 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 63
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2


PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.180
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 61.5 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.158
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 130.4 kN
Ultimate moment force at face of column; Mu = 15.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 64
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear capacity; Vn = v  Vn = 2007.8 kN


Vu / Vn = 0.065
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 285.3 kN
Ultimate moment force at face of column; Mu = 74.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1423.8 kN
Design shear capacity; Vn = v  Vn = 1067.8 kN
Vu / Vn = 0.267
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 85.6 kN
Ultimate moment force at face of column; Mu = 16.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1802.9 kN
Design shear capacity; Vn = v  Vn = 1352.2 kN
Vu / Vn = 0.063
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 330.1 kN
Ultimate moment force at face of column; Mu = 61.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.174
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 65
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter length; lx,perim = 1300 mm


Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD11,Pp2,LRFD11,Pp3,LRFD11,Pp4,LRFD11) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 422.2 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.508 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.208
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD11) = 132.8 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.280 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.214
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 66
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm


Ultimate shear load; Vu = abs(Pp2,LRFD11) = 213.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.542 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.414
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD11) = 13.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.031 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.024
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD11) = 85.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.198 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 67
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa


vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.151
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD11) = 132.8 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.299
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD11) = 213.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.582
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD11) = 13.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.034
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD11) = 85.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 68
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.212
PASS - Design shear capacity exceeds ultimate shear load

Combination 12 results: 1.2D + 1.0L + 1  0.5S + 1.0W

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 65.7 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.159
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 54.0 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.139
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 69
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

PASS - Design moment capacity exceeds ultimate moment load


One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 93.0 kN
Ultimate moment force at face of column; Mu = 10.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.046
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 250.5 kN
Ultimate moment force at face of column; Mu = 65.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1414.4 kN
Design shear capacity; Vn = v  Vn = 1060.8 kN
Vu / Vn = 0.236
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 56.1 kN
Ultimate moment force at face of column; Mu = 9.7 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1917.6 kN
Design shear capacity; Vn = v  Vn = 1438.2 kN
Vu / Vn = 0.039
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 287.5 kN
Ultimate moment force at face of column; Mu = 54.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 70
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.152
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD12,Pp2,LRFD12,Pp3,LRFD12,Pp4,LRFD12) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 349.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.421 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD12) = 110.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.233 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 71
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa


Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.178
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD12) = 192.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.489 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.373
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD12) = 2.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.005 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.004
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 72
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 4


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD12) = 71.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.165 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.126
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD12) = 110.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.249
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD12) = 192.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.525
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD12) = 2.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 73
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Shear strength reduction factor; v = 0.75


Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.005
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD12) = 71.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.177
PASS - Design shear capacity exceeds ultimate shear load
Combination 13 results: 1.2D + 1.0L + 0.5R + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 65.7 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.159
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 54.0 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 74
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm


Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.139
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 93.0 kN
Ultimate moment force at face of column; Mu = 10.5 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.046
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 250.5 kN
Ultimate moment force at face of column; Mu = 65.7 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1414.4 kN
Design shear capacity; Vn = v  Vn = 1060.8 kN
Vu / Vn = 0.236
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 56.1 kN
Ultimate moment force at face of column; Mu = 9.7 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 75
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1917.6 kN
Design shear capacity; Vn = v  Vn = 1438.2 kN
Vu / Vn = 0.039
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 287.5 kN
Ultimate moment force at face of column; Mu = 54.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.152
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD13,Pp2,LRFD13,Pp3,LRFD13,Pp4,LRFD13) - 1.2  (conc  Dcap) 
(Acap - AInsidePerim)) = 349.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.421 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.172
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 76
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 1


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD13) = 110.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.233 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.178
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD13) = 192.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.489 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.373
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD13) = 2.1 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.005 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 77
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00


Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.004
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD13) = 71.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.165 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.126
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD13) = 110.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.249
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD13) = 192.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 78
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.525
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD13) = 2.1 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.005
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD13) = 71.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.177
PASS - Design shear capacity exceeds ultimate shear load

Combination 14 results: (1.2 + 0.2  SDS)D + 1.0L + 1  0.2S + 1.0E

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 112.6 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 79
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.272
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 85.2 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.219
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 20.4 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 605.6 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 545.1 kNm
Mu / Mn = 0.037
PASS - Design moment capacity exceeds ultimate moment load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 80
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Moment design, about x-x axis, negative moment


Ultimate bending moment; Mu = 28.6 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top - y.top / 2 = 422 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02911
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 578.5 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 520.6 kNm
Mu / Mn = 0.055
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 108.0 kN
Ultimate moment force at face of column; Mu = 20.4 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.054
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 419.0 kN
Ultimate moment force at face of column; Mu = 112.6 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1368.6 kN
Design shear capacity; Vn = v  Vn = 1026.5 kN
Vu / Vn = 0.408
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 81
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

One-way shear design at column face, along y axis, top side


Ultimate shear force at face of column; Vu = 102.1 kN
Ultimate moment force at face of column; Mu = 28.6 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1126.1 kN
Design shear capacity; Vn = v  Vn = 844.6 kN
Vu / Vn = 0.121
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 413.1 kN
Ultimate moment force at face of column; Mu = 85.2 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2464.9 kN
Design shear capacity; Vn = v  Vn = 1848.7 kN
Vu / Vn = 0.223
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD14,Pp2,LRFD14,Pp3,LRFD14,Pp4,LRFD14) - 1.321  (conc 
Dcap)  (Acap - AInsidePerim)) = 316.7 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.381 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 82
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.156
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD14) = 77.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.163 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.125
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD14) = 351.6 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.893 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.682
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 83
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 3


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD14) = 169.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.395 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.302
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD14) = 81.7 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.190 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.145
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD14) = 77.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 84
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear capacity; Vn = v  Vn = 443.6 kN


Vu / Vn = 0.175
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD14) = 351.6 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.960
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD14) = 169.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.423
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD14) = 81.7 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.203
PASS - Design shear capacity exceeds ultimate shear load
Combination 15 results: 0.9D + 1.0W
Moment design, about y-y axis, positive moment
Ultimate bending moment; Mu = 57.6 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 85
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm


Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.139
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 47.5 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.122
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 57.8 kN
Ultimate moment force at face of column; Mu = 5.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.029
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 217.9 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 86
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate moment force at face of column; Mu = 57.6 kNm


Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1399.3 kN
Design shear capacity; Vn = v  Vn = 1049.5 kN
Vu / Vn = 0.208
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 26.2 kN
Ultimate moment force at face of column; Mu = 3.4 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2291.9 kN
Design shear capacity; Vn = v  Vn = 1718.9 kN
Vu / Vn = 0.015
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 249.5 kN
Ultimate moment force at face of column; Mu = 47.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2526.9 kN
Design shear capacity; Vn = v  Vn = 1895.1 kN
Vu / Vn = 0.132
PASS - Design shear capacity exceeds ultimate shear load
Column modified two way shear design
Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 87
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Ultimate shear load; Vu = abs(Sum(Pp1,LRFD15,Pp2,LRFD15,Pp3,LRFD15,Pp4,LRFD15) - 0.9  (conc  Dcap) 


(Acap - AInsidePerim)) = 280.4 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.338 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.138
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD15) = 89.0 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.188 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.143
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 2
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD15) = 172.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.438 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 88
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile location factor (11.11.2.1); s =20


Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.334
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD15) = 19.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.045 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.035
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD15) = 55.4 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.129 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 89
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa


vug / vn = 0.098
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD15) = 89.0 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.201
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD15) = 172.2 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.470
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD15) = 19.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.049
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD15) = 55.4 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.138
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 90
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Combination 16 results: (0.9 - 0.2  SDS)D + 1.0E

Moment design, about y-y axis, positive moment


Ultimate bending moment; Mu = 98.0 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot / 2 = 339 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02278
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 459.9 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 413.9 kNm
Mu / Mn = 0.237
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, positive moment
Ultimate bending moment; Mu = 73.5 kNm
Tension reinforcement provided; (12) 19 mm  bot bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - dembed - cnom,bot - x.bot - y.bot / 2 = 320 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02134
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 432.7 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 389.5 kNm
Mu / Mn = 0.189
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about y-y axis, negative moment
Ultimate bending moment; Mu = 28.8 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 91
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Area of tension reinforcement provided; As.prov = 3402 mm2


Minimum area of reinforcement (10.5.4); As.min = 0.0018  Ly  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top / 2 = 441 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Ly) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.03055
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 605.6 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 545.1 kNm
Mu / Mn = 0.053
PASS - Design moment capacity exceeds ultimate moment load
Moment design, about x-x axis, negative moment
Ultimate bending moment; Mu = 40.0 kNm
Tension reinforcement provided; (12) 19 mm  top bars (152 mm c/c)
Area of tension reinforcement provided; As.prov = 3402 mm2
Minimum area of reinforcement (10.5.4); As.min = 0.0018  Lx  Dcap = 1620 mm2
PASS - Area of reinforcement provided exceeds minimum
Maximum spacing of reinforcement (10.5.4); smax = min(3  Dcap, 457 mm) = 457 mm
PASS - Maximum permissible reinforcement spacing exceeds actual spacing
Depth to tension reinforcement; d = Dcap - cnom,top - x.top - y.top / 2 = 422 mm
Depth of compression block; a = As.prov  fy / (0.85  f'c  Lx) = 33 mm
Neutral axis factor; 1 = 0.85
Depth to neutral axis; c = a / 1 = 39 mm
Strain in tensile reinforcement (10.3.5); t = 0.003  d / c - 0.003 = 0.02911
PASS - Tensile strain exceeds minimum required, 0.004
Nominal moment capacity; Mn = As.prov  fy  (d - a / 2) = 578.5 kNm
Flexural strength reduction factor; f = min(max(0.65 + (t - 0.002)  (250 / 3), 0.65), 0.9) = 0.900
Design moment capacity; Mn = f  Mn = 520.6 kNm
Mu / Mn = 0.077
PASS - Design moment capacity exceeds ultimate moment load
One-way shear design at column face, along x axis, left side
Ultimate shear force at face of column; Vu = 171.7 kN
Ultimate moment force at face of column; Mu = 28.8 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wL = 50 mm
Shear strength reduction factor; v = 0.75
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 92
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wL + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 2677.1 kN
Design shear capacity; Vn = v  Vn = 2007.8 kN
Vu / Vn = 0.085
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along x axis, right side
Ultimate shear force at face of column; Vu = 360.0 kN
Ultimate moment force at face of column; Mu = 98.0 kNm
Depth to reinforcement; dv = min(dx.bot,dx.top) = 339 mm
Distance to nearest pile; wR = 126 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wR + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Ly  dv = 1344.8 kN
Design shear capacity; Vn = v  Vn = 1008.6 kN
Vu / Vn = 0.357
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, top side
Ultimate shear force at face of column; Vu = 156.1 kN
Ultimate moment force at face of column; Mu = 40.0 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wT = 112 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wT + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 1294.4 kN
Design shear capacity; Vn = v  Vn = 970.8 kN
Vu / Vn = 0.161
PASS - Design shear capacity exceeds ultimate shear load
One-way shear design at column face, along y axis, bottom side
Ultimate shear force at face of column; Vu = 344.5 kN
Ultimate moment force at face of column; Mu = 73.5 kNm
Depth to reinforcement; dv = min(dy.bot,dy.top) = 320 mm
Distance to nearest pile; wB = 50 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (CRSI Section 5.3); Vn = min((dv / (wB + etolerance))  (3.5 - 2.5  min(1.0,Mu / (Vu  dv)))  (1.9 
  (f'c  1 psi) + 0.1    (f'c  1 psi)  max(1.0,Vu  dv / Mu)),10   
(f'c  1 psi))  Lx  dv = 2384.6 kN
Design shear capacity; Vn = v  Vn = 1788.4 kN
Vu / Vn = 0.193
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 93
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Column modified two way shear design


Depth to reinforcement; dv2 = 320 mm
Distance to closest pile, x direction; wx = 50 mm
Distance to closest pile, y direction; wy = 50 mm
Shear perimeter length; lx,perim = 1300 mm
Shear perimeter width; ly,perim = 1300 mm
Shear perimeter, modified (CRSI 5.3); bs = lx,perim + ly,perim = 2600 mm
Area inside shear perimeter; AInsidePerim = lx,perim  ly,perim = 1690000.000 mm2
Ultimate shear load; Vu = abs(Sum(Pp1,LRFD16,Pp2,LRFD16,Pp3,LRFD16,Pp4,LRFD16) - 0.779  (conc 
Dcap)  (Acap - AInsidePerim)) = 191.5 kN
Ultimate shear stress from vertical load; vumod = max(Vu / (bs  dv2),0 MPa) = 0.231 MPa
Shear perimeter, traditional (11.11.1.2); bo = 2  lx,perim + 2  ly,perim = 5200 mm
Column geometry factor (11.11.2.1);  = ly,col / lx,col = 1.00
Column location factor (11.11.2.1); s =20
Concrete shear strength, traditional (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 1.418 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.418 MPa
Concrete shear strength, modified (CRSI 5.3); vcp.mod = min((dv2 / (2 (average(wx,wy) + etolerance)))  (bo / bs)  vcp, 32  (f'c
 1 MPa)) = 3.568 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = vcp.col.mod = 3.261 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn.col.mod = 2.446 MPa
vumod / vn = 0.094
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 1
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 743 mm
Shear perimeter width; ly,perim = 743 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1485 mm
Ultimate shear load; Vu = abs(Pp1,LRFD16) = 38.5 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.081 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.768 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.062
PASS - Design shear capacity exceeds ultimate shear load
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 94
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile two way shear design, pile 2


Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 587 mm
Shear perimeter width; ly,perim = 645 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1232 mm
Ultimate shear load; Vu = abs(Pp2,LRFD16) = 315.3 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.801 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 3.157 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.612
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 3
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 712 mm
Shear perimeter width; ly,perim = 631 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1343 mm
Ultimate shear load; Vu = abs(Pp3,LRFD16) = 200.9 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.468 MPa
Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00
Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.968 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.357
PASS - Design shear capacity exceeds ultimate shear load
Pile two way shear design, pile 4
Depth to reinforcement; dv2 = 320 mm
Shear perimeter length; lx,perim = 666 mm
Shear perimeter width; ly,perim = 681 mm
Shear perimeter (11.11.1.2); bo = lx,perim + ly,perim = 1347 mm
Ultimate shear load; Vu = abs(Pp4,LRFD16) = 53.2 kN
Ultimate shear stress from vertical load; vug = max(Vu / (bo  dv2),0 MPa) = 0.123 MPa
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 95
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Pile geometry factor (11.11.2.1);  = ly,pile / lx,pile = 1.00


Pile location factor (11.11.2.1); s =20
Pile shear strength (11.11.2.1); vcpa = 0.17  (1 + 2 / )    (f'c  1 MPa) = 2.699 MPa
vcpb = 0.083  (s  dv2 / bo + 2)    (f'c  1 MPa) = 2.961 MPa
vcpc = 0.33    (f'c  1 MPa) = 1.746 MPa
vcp = min(vcpa,vcpb,vcpc) = 1.746 MPa
Shear strength reduction factor; v = 0.75
Nominal shear stress capacity (Eq. 11-2); vn = min(vcpa,vcpb,vcpc) = 1.746 MPa
Design shear stress capacity (Eq. 11-1); vn = v  vn = 1.310 MPa
vug / vn = 0.094
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 1
Ultimate shear force; Vu = abs(Pp1,LRFD16) = 38.5 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp1,Ly - yp1) + min(xp1,Lx - xp1) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 2058 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 591.4 kN
Design shear capacity; Vn = v  Vn = 443.6 kN
Vu / Vn = 0.087
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 2
Ultimate shear force; Vu = abs(Pp2,LRFD16) = 315.3 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp2,Ly - yp2) + min(xp2,Lx - xp2) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1699 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 488.4 kN
Design shear capacity; Vn = v  Vn = 366.3 kN
Vu / Vn = 0.861
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 3
Ultimate shear force; Vu = abs(Pp3,LRFD16) = 200.9 kN
Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm
Width of design section; b = (min(yp3,Ly - yp3) + min(xp3,Lx - xp3) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1857 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 533.7 kN
Design shear capacity; Vn = v  Vn = 400.3 kN
Vu / Vn = 0.502
PASS - Design shear capacity exceeds ultimate shear load
One-way corner pile shear design, pile 4
Ultimate shear force; Vu = abs(Pp4,LRFD16) = 53.2 kN
Project Job Ref.
N/A Kohler
Section Sheet no./rev.
PC4 Grid D/5 96
Calc. by Date Chk'd by Date App'd by Date
Paa 12/8/2018

Depth to reinforcement; dv2 = min(dx.bot,dy.bot,dx.top,dy.top) = 320 mm


Width of design section; b = (min(yp4,Ly - yp4) + min(xp4,Lx - xp4) + (dp / 2 + min(dv2,330 mm) -
etolerance) / sin(45 deg)) / sin(45 deg) = 1863 mm
Shear strength reduction factor; v = 0.75
Nominal shear capacity (Eq. 11-3); Vn = 0.17    (f'c  1 MPa)  b  dv2 = 535.3 kN
Design shear capacity; Vn = v  Vn = 401.5 kN
Vu / Vn = 0.132
PASS - Design shear capacity exceeds ultimate shear load

(12) 19 mm  top bars (152 mm c/c)

(12) 19 mm  bot bars (152 mm c/c)

(12) 19 mm  bot bars (152 mm c/c)


(12) 19 mm  top bars (152 mm c/c)
1800 mm

1800 mm

;
;

You might also like