You are on page 1of 26

1 2 3 4 5 6 7 8 9 10

Information.dwg
Plotted: 3/20/2017 11:29 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R000.1 Project

Grady Memorial Hospital


ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100

Facade Rehabilitation Project


Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

G
Atlanta, Georgia L

IN
N

D
O

D
S

BI
G
Grady Project No. F2016008 G
E
S

R
WJE Project No. 2016.1879 O

FO
P
Consultants R
INDEX TO DRAWINGS SCOPE OF WORK GENERAL NOTES
P U
BASE BID - SCOPE OF WORK BID ALTERNATES 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN FIELD. DO NOT SCALE DRAWINGS.
R000.01 PROJECT INFORMATION ORIGINAL BUILDING ORIGINAL BUILDING DIMENSIONS SHOWN ON THE DRAWINGS ARE TAKEN FROM THE ORIGINAL CONSTRUCTION DOCUMENTS AND
R000.02 SITE PLAN ARE PROVIDED FOR INFORMATION ONLY.
1. THROUGH-WALL FLASHING REPAIRS: CONTRACTOR SHALL REMOVE FOUR COURSES OF BRICK MASONRY ALTERNATE NO. 1 - IN LIEU OF WINDOW PERIMETER SEALANT REPLACEMENT OUTLINED ABOVE FOR THE
R100.01 ORIGINAL BUILDING ELEVATIONS
ABOVE THE SHELF ANGLE AND ONE COURSE BENEATH THE SHELF ANGLE AS NECESSARY TO INSTALL NEW ORIGINAL BUILDING, REMOVE AND REPLACE FAILED WINDOW PERIMETER SEALANT ONLY, INCLUDING: REMOVAL 2. CONTRACTOR SHALL VERIFY ALL QUANTITIES. QUANTITIES SHOWN ARE FOR ESTIMATING PURPOSES ONLY.
R100.02 ORIGINAL BUILDING ELEVATIONS
THROUGH-WALL FLASHING AT LOCATIONS IDENTIFIED ON THE BUILDING ELEVATIONS ON SHEETS R100.01 OF FAILED SEALANT TO A VERTICAL OR HORIZONTAL TRANSITION, SURFACE PREPARATION, AND INSTALLATION ALLOWANCE QUANTITIES ARE ESTIMATED FROM A VISUAL SURVEY ONLY.
R100.03 ORIGINAL BUILDING ELEVATIONS
R100.04 ORIGINAL BUILDING ELEVATIONS THROUGH R100.12. NEW THROUGH-WALL FLASHING REPAIRS SHALL BE PERFORMED IN ACCORDANCE WITH OF NEW BACKER ROD AND SEALANT. PAYMENT BASED ON PER LINEAR FOOT INSTALLED. IF ACCEPTED,
R100.05 ORIGINAL BUILDING ELEVATIONS DETAILS 1 THROUGH 3/R500.01 AND SPECIFICATION SECTIONS 07 62 00 AND 07 65 00. CONTRACTOR SHALL 3. THE CONTRACTOR SHALL COORDINATE REQUIREMENTS AND PROVIDE PROOF OF INSURANCE PRIOR TO THE
ALTERNATE NO. 2 - IN LIEU OF THROUGH-WALL FLASHING REPAIRS FOR THE ORIGINAL BUILDING, INSTALL
R100.06 ORIGINAL BUILDING ELEVATIONS INSPECT SHELF ANGLE ANCHORAGE AT EACH LOCATION PRIOR TO REMOVAL OF BRICK MASONRY BENEATH START OF WORK.
THROUGH-WALL FLASHING REPAIRS AT FIFTY PERCENT (50%) OF THE SHELF ANGLE LOCATIONS, TO BE
R100.07 ORIGINAL BUILDING ELEVATIONS THE EXISTING STEEL SHELF ANGLES. NOTIFY ARCHITECT/ENGINEER OF ANY DISPLACED, LOOSE, OR MISSING DETERMINED BY A/E, INCLUDING NEW SUPPLEMENTAL HELICAL ANCHORS ABOVE AND BELOW BRICK MASONRY
R100.08 ORIGINAL BUILDING ELEVATIONS SHELF ANGLE ANCHORS. 4. THERE SHALL BE COMPLETE COOPERATION BETWEEN THE GENERAL CONTRACTOR AND SUB-CONTRACTORS
F TO BE REMOVED; REMOVAL OF FOUR COURSES OF BRICK MASONRY VENEER ABOVE THE SHELF ANGLE AND ONE TO ENSURE SATISFACTORY PROGRESS AND PERFORMANCE OF THE WORK. F
R100.09 ORIGINAL BUILDING ELEVATIONS
2. BASE OF WALL FLASHING REPAIRS: CONTRACTOR SHALL INSTALL NEW BASE OF WALL FLASHING REPAIRS AT COURSE BELOW; CLEANING, PRIMING, AND PAINTING EXISTING STEEL SHELF ANGLES; NEW STAINLESS STEEL
R100.10 ORIGINAL BUILDING ELEVATIONS
LOCATIONS ILLUSTRATED IN THE BUILDING ELEVATIONS ON SHEETS R100.01 THROUGH R100.12 IN FLASHING; NEW SELF-ADHERED MEMBRANE FLASHING; NEW BRICK MASONRY; AND NEW SEALANT BENEATH 5. THE CONTRACTOR SHALL VERIFY EXISTING PLUMBING AND ELECTRICAL LINES AND EQUIPMENT THAT WILL BE
R100.11 ORIGINAL BUILDING ELEVATIONS
R100.12 ORIGINAL BUILDING ELEVATIONS ACCORDANCE WITH DETAIL 4/R500.01 AND SPECIFICATION SECTIONS 07 62 00 AND 07 65 00. THROUGH-WALL FLASHING. IF ACCEPTED, ALTERNATE 2 BID PROVIDED SHALL REPLACE THE THROUGH-WALL ACCESSED AS PART OF WORK PERFORMED. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY EQUIPMENT,
R200.01 WEST ADDITION ELEVATIONS FLASHING REPAIRS INCLUDED IN THE BASE BID. LABOR, MATERIALS, AND COMPONENTS REQUIRED FOR THE TEMPORARY RELOCATION OF
3. SUPPLEMENTAL BRICK VENEER ANCHORAGE: CONTRACTOR SHALL INSTALL NEW SUPPLEMENTAL BRICK
R200.02 WEST ADDITION ELEVATIONS MECHANICAL/ELECTRICAL EQUIPMENT AND PLUMBING LINES DURING THE REPAIR WORK.
MASONRY REPAIR ANCHORS AT ISOLATED LOCATIONS ILLUSTRATED IN THE BUILDING ELEVATIONS ON WEST ADDITION
R200.03 WEST ADDITION ELEVATIONS SHEETS R100.01 THROUGH R100.12 AND AT LOCATIONS DETERMINED BY A/E DURING CLOSE-UP INSPECTION
R300.01 SOUTH ADDITION ELEVATIONS ALTERNATE NO. 3 - PERFORM FACADE REPAIRS TO THE WEST ADDITION, AS INDICATED IN ITEMS 1 THROUGH 7 6. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, LICENSES AND GOVERNMENT FEES AS
OF THE BUILDING FACADE. NEW ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH DETAILS 2 AND BELOW. REQUIRED. THE CONTRACTOR SHALL COMPLY WITH CODES, ORDINANCES, RULES, REGULATIONS, ORDERS
R300.02 SOUTH ADDITION ELEVATIONS
4/R500.03 AND SPECIFICATION SECTION 04 01 21. FOR BIDDING PURPOSES, CONTRACTOR SHALL ASSUME AND OTHER LEGAL REQUIREMENTS OF PUBLIC AUTHORITY, WHICH BEAR ON THE PERFORMANCE OF THE
R400.01 ENLARGED ELEVATIONS 1. WINDOW WET SEAL REPAIRS: CONTRACTOR SHALL INSTALL WET SEAL REPAIRS TO THE INSTALLED
1,250 SUPPLEMENTAL ANCHORS WILL BE INSTALLED THROUGHOUT THE BUILDING FACADE, IN ADDITION TO WORK.
R500.01 BRICK MASONRY REPAIR DETAILS ALUMINUM-FRAMED WINDOW SYSTEMS AS ILLUSTRATED IN DETAILS 4 AND 5/R400.01 AND SPECIFICATION
R500.02 BRICK MASONRY REPAIR DETAILS THE SUPPLEMENTAL ANCHORS ILLUSTRATED TO BE INSTALLED IN THE THROUGH-WALL FLASHING REPAIRS.
SECTION 07 92 00. 7. CONTRACTOR SHALL PROMPTLY SUBMIT VERBAL AND WRITTEN NOTICE TO THE ARCHITECT/ENGINEER OF
R500.03 BRICK MASONRY REPAIR DETAILS 4. REBUILD BRICK MASONRY VENEER: AT LOCATIONS ILLUSTRATED ON THE BUILDING ELEVATIONS ON SHEETS
R500.04 CAST STONE AND CONCRETE REPAIR DETAILS 2. SEALANT REPLACEMENT: CONTRACTOR SHALL REMOVE AND REPLACE EXISTING SEALANT AT PRECAST OBSERVED VARIANCE OF THE CONTRACT DOCUMENTS FROM ACTUAL ON-SITE CONDITIONS.
R100.01 THROUGH R100.12, AND AT LOCATIONS IDENTIFIED BY ARCHITECT/ENGINEER DURING INITIAL
R500.05 STONE MASONRY REPAIR DETAILS INSPECTION OF FACADE AREAS, CONTRACTOR SHALL REMOVE EXISTING BRICK MASONRY AND REBUILD IN CONCRETE JOINTS AND STONE PANEL JOINTS, INCLUDING WINDOW PERIMETER SEALANTS, INCLUDING
R500.06 TYPICAL REPAIR DETAILS 8. CONTRACTOR SHALL SUPPLY THE OWNER WITH MATERIAL SAFETY DATA SHEETS (MSDS) FOR EACH CHEMICAL
ACCORDANCE WITH DETAILS 9/R500.01 AND 6/R500.03 AND SPECIFICATION SECTION 04 01 21. FOR BIDDING REMOVAL OF EXISTING SEALANT, SURFACE PREPARATION, AND INSTALLATION OF NEW BACKER ROD AND
THAT WILL BE BROUGHT ONTO THE JOB SITE AND SHALL COMPLY WITH THE REQUIREMENTS OF THE OSHA
PURPOSES, CONTRACTOR SHALL ASSUME 3,500 SQUARE FEET OF BRICK VENEER WILL BE REMOVED AND SEALANT.IN ACCORDANCE WITH DETAILS 1 AND 2/R500.06 AND SPECIFICATION SECTION 07 92 00.
HAZARD COMMUNICATION STANDARD
RECONSTRUCTED. 3. BASE OF WALL SEALANT REPAIRS: CONTRACTOR SHALL REMOVE AND REPLACE SILICONE SEALANT ALONG
5. MASONRY REPOINTING: CONTRACTOR SHALL REPOINT ALL MORTAR JOINTS WITHIN THE PENTHOUSE AND THE BASE OF THE WALL AROUND THE PERIMETER OF THE WESTERN ADDITION. NEW SEALANT SHALL BE 9. THE CONTRACTOR MUST SUBMIT DEMOLITION AND CONSTRUCTION SCHEDULES TO THE OWNER AND
ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO BEGINNING DEMOLITION
APPLICABLE CODES AND STANDARDS PARAPET WALLS IN ACCORDANCE WITH DETAILS 7 AND 9/R500.02 AND SPECIFICATION SECTION 04 01 27.
LOCATION OF REPOINTING SHALL BE AS ILLUSTRATED ON THE BUILDING ELEVATIONS ON SHEETS R100.1 4.
INSTALLED IN ACCORDANCE WITH DETAILS 1 AND 2/R500.06 AND SPECIFICATION SECTION 07 92 00.
GRANITE AND MARBLE PANEL CRACK REPAIRS: CONTRACTOR SHALL REPAIR CRACKS IN THE STONE PANELS 10. THE PRODUCTS SPECIFIED ARE BELIEVED TO HAVE PROPERTIES ADEQUATE FOR SUCCESSFUL COMPLETION
E ALL WORK SHALL BE IN ACCORDANCE WITH THE CURRENT BUILDING CODE FOR THE CITY OF SAINT PETERSBURG, THROUGH R100.12 AND INDICATED BY ARCHITECT/ENGINEER DURING INITIAL INSPECTIONS. IN ACCORDANCE WITH DETAILS 4 AND 5/R500.06 AND SPECIFICATION SECTION 04 01 40.91. FOR BIDDING E
OF THE WORK. IF THE CONTRACTOR HAS FOUND THESE PRODUCTS TO BE UNACCEPTABLE OR HAS HAD
FLORIDA. THE PUBLICATIONS LISTED BELOW ARE THE GOVERNING CODES AND STANDARDS AND ARE REFERENCED 6. BRICK MASONRY CRACK REPAIR: CONTRACTOR SHALL REPAIR CRACKS IN THE BRICK MASONRY VENEER PURPOSES, CONTRACTOR SHALL ASSUME 300 LINEAR FEET OF CRACK REPAIR THROUGHOUT THE WESTERN DIFFICULTY USING THESE MATERIALS, THE CONTRACTOR SHALL IMMEDIATELY INFORM THE
BY THE BASIC DESIGNATION. IN THE CASE OF CONFLICTING REQUIREMENTS, THE BUILDING CODE SHALL GOVERN. AND MASS WALL SYSTEMS IN ACCORDANCE WITH DETAILS 4 AND 5/R500.06 AND SPECIFICATION SECTION 04 ADDITION. ARCHITECT/ENGINEER
01 21. FOR BIDDING PURPOSES, CONTRACTOR SHALL ASSUME THAT 2,500 LINEAR FEET OF CRACK REPAIR 5. GRANITE AND MARBLE PANEL STONE MASONRY SPALL REPAIRS: CONTRACTOR SHALL INSTALL SPALL
BUILDING CODE INTERNATIONAL BUILDING CODE, 2012 EDITION 11. CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF THE REPAIR WORK
SHALL BE PERFORMED IN THE MASONRY VENEER AND 1,000 LINEAR FEET IN THE MASS MASONRY PARAPET REPAIRS TO CRACKED OR SPALLED CORNERS OF THE STONE PANELS THROUGHOUT THE BUILDING FACADE
ACI AMERICAN CONCRETE INSTITUTE, 318-10 BUILDING CODE REQUIREMENTS FOR STRUCTURAL WALLS. AS ILLUSTRATED IN DETAILS 1 AND 2/R500.05 AND SPECIFICATION SECTION 04 01 40.91. FOR BIDDING
12. WISS, JANNEY, ELSTNER ASSOCIATES, INC. (WJE) SHALL NOT HAVE CONTROL OVER OR CHARGE OF AND SHALL
CONCRETE 7. CAST STONE SPALL REPAIR: CONTRACTOR SHALL REMOVE ALL LOOSE OR INCIPIENT SPALLS IN EXCESS OF 2 PURPOSES, CONTRACTOR SHALL ASSUME 80 SPALL REPAIR TO BE PERFORMED THROUGHOUT THE NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES,
INCHES BY 2 INCHES FROM THE CAST STONE WINDOW SILLS AND COPING THROUGHOUT THE ORIGINAL WESTERN ADDITION. OR FOR SAFETY PRECAUTIONS AND SAFETY PROGRAMS IN CONNECTION WITH THE PROJECT. SINCE THESE
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS BUILDING AND INSTALL NEW CEMENTITIOUS PATCH MATERIAL IN ACCORDANCE WITH DETAIL 7/R500.04 AND ARE THE RESPONSIBILITY OF OTHERS, WJE SHALL NOT BE RESPONSIBLE FOR THE CONTRACTOR'S SCHEDULES
6. THIN STONE CLADDING REPAIRS: CONTRACTOR SHALL REPAIR BUG HOLES OR OTHER NATURAL
SPECIFICATION SECTION 03 01 34. FOR BIDDING PURPOSES, CONTRACTOR SHALL ASSUME 400 SMALL DEPRESSIONS IN THE THIN STONE CLADDING EXCEEDING 1/4-INCH IN DEPTH WITH NEW STONE PATCHING OR FAILURE TO CARRY OUT THE PROJECT IN ACCORDANCE WITH CONTRACT DOCUMENTS. WJE SHALL NOT
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS HAVE CONTROL OVER OR CHARGE OF ACTS OR OMISSIONS OF THE CONTRACTOR, SUBCONTRACTORS, OR
SPALLS, 50 MEDIUM SPALLS, AND 20 LARGE SPALLS WILL BE REPAIRED. MATERIALS IN ACCORDANCE WITH DETAIL 6/R500.05 AND SPECIFICATION SECTION 04 01 40.91. FOR BIDDING
THEIR AGENTS OR EMPLOYEES, OR OF ANY OTHER NON-WJE PERSONS PERFORMING PORTIONS OF THE
ICRI INTERNATIONAL CONCRETE REPAIR INSTITUTE 8. CAST STONE JOINT REPLACEMENT AT WINDOW PERIMETERS: CONTRACTOR SHALL GRIND GROUTED JOINT PURPOSES, CONTRACTOR SHALL ASSUME 125 PATCHES WILL BE INSTALLED THROUGHOUT THE WESTERN
PROJECT
BETWEEN CAST STONE UNITS AT WINDOW PERIMETERS AND INSTALL NEW SILYL TERMINATED ADDITION.
OSHA OCCUPATIONAL SAFETY AND HEALTH ACT POLYURETHANE SEALANT IN ACCORDANCE WITH DETAIL 5/R500.01 AND SPECIFICATION SECTION 07 92 00. 7. FACADE CLEANING: CONTRACTOR SHALL CLEAN ALL PRECAST CONCRETE PANELS, MARBLE, GRANITE, AND 13. THE CONTRACTOR WILL LIMIT ON-SITE STORAGE OF MATERIALS TO THOSE AREAS IDENTIFIED BY THE OWNER.
9. CONCRETE SPALL REPAIR AT PROMENADE: CONTRACTOR SHALL REMOVE LOOSE, DETERIORATED, OR THIN STONE PANELS THROUGHOUT THE WESTERN ADDITION FACADE IN ACCORDANCE WITH SPECIFICATION THE CONTRACTOR SHALL NOT UNREASONABLY ENCUMBER SITE WITH MATERIALS OR EQUIPMENT. THE
SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION MATERIALS AND EQUIPMENT SHALL BE CONFINED TO THE AREAS INDICATED IN THE CONTRACT DOCUMENTS
DELAMINATED CONCRETE FROM THE CAST-IN-PLACE CONCRETE COLUMNS AND BEAMS AT THE 16TH FLOOR SECTION 04 01 20. CARE SHALL BE TAKEN TO PREVENT DAMAGE OR ETCHING OF THE ALUMINUM WINDOW
SYSTEMS, DECORATIVE PANELS, AND GLAZING THROUGHOUT THE BUILDING. OR BY THE DIRECTION OF THE OWNER OR ARCHITECT/ENGINEER. DO NOT LOAD STRUCTURE WITH WEIGHT
PROMENADE. CONTRACTOR SHALL INSTALL NEW CEMENTITIOUS PATCHING MATERIAL IN ACCORDANCE WITH
THAT WILL ENDANGER STRUCTURE. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR THE
DETAIL 8/R500.04 AND SPECIFICATION SECTION 03 01 34. ALTERNATE NO. 3A - FOR THE WEST ADDITION, IN LIEU OF THE SEALANT REPLACEMENT IN ITEM 3.2 ABOVE, PROTECTION AND SAFEKEEPING OF PRODUCTS STORED ON PREMISES. CONTRACTOR SHALL MOVE ANY Project

D
ABBREVIATION LIST 10. CAST-IN-PLACE CONCRETE PAINTING AT PROMENADE: CONTRACTOR SHALL APPLY AN ACRYLIC COATING TO INSPECT EXISTING SEALANTS AND REPLACE FAILED SEALANTS ONLY, INCLUDING: INSPECTION OF ALL EXISTING
SEALANTS, REMOVAL OF FAILED SEALANTS TO A HORIZONTAL OR VERTICAL PANEL JOINT OR TRANSITION,
STORED MATERIAL OR PRODUCTS WHICH INTERFERE WITH OPERATIONS OF THE OWNER.
D
THE EXPOSED CAST-IN-PLACE CONCRETE BEAMS AND COLUMNS AT THE PROMENADE ON THE 16TH FLOOR
SURFACE PREPARATION, AND NEW BACKER ROD AND SEALANT. FOR BIDDING PURPOSES, CONTRACTOR SHALL
CMU CONCRETE MASONRY UNIT AS SPECIFIED IN SPECIFICATION SECTION 09 97 24.
ASSUME 12,500 LINEAR FEET OF SEALANT REPLACEMENT AT THE WEST ADDITION. IF ACCEPTED, ALTERNATE 3A
14. WATER AND ELECTRICITY MAY BE TAKEN FROM BUILDING FOR CONSTRUCTION PURPOSES ONLY AT AREAS
IDENTIFIED ACCEPTABLE BY THE OWNER. TOILET FACILITIES IN BUILDING SHALL NOT BE USED BY THE
Grady Memorial Hospital
DIA. DIAMETER 11. CAST-IN-PLACE CONCRETE LEDGES: CONTRACTOR SHALL APPLY A NEW URETHANE TRAFFIC BEARING BID PROVIDED SHALL REPLACE THE SEALANT REPLACEMENT INCLUDED IN ALTERNATE 3.
EMBED. EMBEDMENT MEMBRANE TO SKY FACING AND VERTICAL SURFACES OF THE CAST-IN-PLACE CONCRETE LEDGES AT THE
CONTRACTOR.
Facade Rehabilitation - Project
O.C. ON-CENTER 16TH FLOOR OF THE A AND B WING IN ACCORDANCE WITH DETAIL 6/R500.04 AND SPECIFICATION SECTION 07 SOUTH ADDITION 15. CONTRACTOR SHALL PROVIDE AND MAINTAIN REQUIRED DUST BARRIERS, CANOPIES, BARRICADES,
SIM.
TYP.
SIMILAR
TYPICAL
18 00.
ALTERNATE NO. 4 - PERFORM FACADE REPAIRS TO THE SOUTH ADDITION, AS INDICATED IN ITEMS 1 THROUGH 6
PROTECTION AND WARNING LIGHTS IN GOOD CONDITION UNTIL THE COMPLETION OF THE WORK REQUIRING No. F2016008
SUCH PROTECTION AND THEN REMOVE THE SAME. ALL CANOPIES AND BARRICADES SHALL COMPLY WITH
V.I.F. VERIFY IN FIELD 12. STEEL LINTEL COATING: CONTRACTOR SHALL CLEAN, PRIME, AND PAINT THE STEEL LINTELS AND SHELF
ANGLES THROUGHOUT THE BUILDING IN ACCORDANCE WITH SPECIFICATION SECTION 09 97 13. PRIOR TO
BELOW. FEDERAL, STATE AND LOCAL LAWS AND REGULATIONS. 80 Jesse Hill Jr. Dr., SE
1. SEALANT REPLACEMENT: CONTRACTOR SHALL REMOVE AND REPLACE EXISTING SEALANT AT STONE PANEL
COATING, CONTRACTOR SHALL REMOVE ALL CORROSION PRODUCT, DIRT, DEBRIS, OR DELETERIOUS
MATERIALS.
JOINTS, INCLUDING WINDOW PERIMETER SEALANTS, INCLUDING REMOVAL OF EXISTING SEALANT, SURFACE 16. THE CONTRACTOR SHALL MAINTAIN PREMISES FREE FROM ACCUMULATIONS OF WASTE MATERIAL AND Atlanta, Georgia 30303
PREPARATION, AND INSTALLATION OF NEW BACKER ROD AND SEALANT IN ACCORDANCE WITH DETAILS 1 RUBBISH.
13. MISCELLANEOUS STEEL PAINTING: CONTRACTOR SHALL CLEAN, PRIME, AND PAINT ALL EXPOSED STEEL AND 2/R500.06 AND SPECIFICATION SECTION 07 92 00. 17. THE CONTRACTOR IS TO RETURN DAMAGED AREAS TO ORIGINAL CONDITION.
SYMBOL LEGEND ELEMENTS, INCLUDING BUT NOT LIMITED TO EXTERIOR DOORS, LADDERS, RAILINGS, AND GUARDRAILS IN
ACCORDANCE WITH SPECIFICATION SECTION 09 97 13.
2. BASE OF WALL SEALANT REPAIRS: CONTRACTOR SHALL REMOVE AND REPLACE SILICONE SEALANT ALONG 18. THE CONTRACTOR SHALL PROTECT GROUNDS AND LANDSCAPING WHEN PERFORMING WORK. THE
THE BASE OF THE WALL AROUND THE PERIMETER OF THE SOUTHERN ADDITION. NEW SEALANT SHALL BE CONTRACTOR WILL BE RESPONSIBLE FOR DAMAGE TO GROUNDS AND LANDSCAPING AND BE REQUIRED TO
14. WINDOW PERIMETER SEALANT REPLACEMENT: CONTRACTOR SHALL REMOVE AND REPLACE PERIMETER INSTALLED IN ACCORDANCE WITH DETAIL 7/R500.05 AND SPECIFICATION SECTION 07 92 00. REPAIR OR REPLACE AS NECESSARY.
EXTERIOR ELEVATION SEALANTS AT WINDOW SYSTEMS WITH NEW SILICONE SEALANT AS IDENTIFIED IN DETAILS 1 THROUGH
1 3. STONE MASONRY SPALL REPAIRS: CONTRACTOR SHALL INSTALL SPALL REPAIRS TO CRACKED OR SPALLED
(DRAWING 1, SHEET A1.0) ENLARGED DETAIL 3/R400.01. 19. CONTRACTOR SHALL COMPLY WITH ALL SECURITY PROCEDURES REQUIRED BY THE OWNER.
A1.0 CORNERS OF THE STONE PANELS THROUGHOUT THE BUILDING FACADE. DUTCHMAN REPAIRS SHALL BE
(DRAWING 1, SHEET A1.0)
15. GANGED WINDOW SYSTEM SEALANT: CONTRACTOR SHALL INSTALL NEW PREFORMED SILICONE SEALANT AT INSTALLED IN ACCORDANCE WITH DETAILS 1 AND 2/R500.05 AND SPECIFICATION SECTION 04 01 40.91. FOR 20. COSTS CAUSED BY ILL-TIMED WORK, DEFECTIVE WORK OR WORK NOT CONFORMING TO THE CONTRACT
1 SECTION DETAIL GANGED RIBBON WINDOW SYSTEM ASSEMBLIES AS ILLUSTRATED IN DETAIL 2/R400.01. BIDDING PURPOSES, CONTRACTOR SHALL ASSUME 100 SPALL REPAIRS TO BE PERFORMED THROUGHOUT Client
DOCUMENTS, ARE THE RESPONSIBILITY OF THE CONTRACTOR.
A1.0 (DRAWING 1, SHEET A1.0) 1 THE SOUTHERN ADDITION.
16. WINDOW SYSTEM GLAZING GASKET SEALING: CONTRACTOR SHALL REMOVE AND REPLACE FAILED GLAZING
C A1.0 C
21. THE CONTRACTOR SHALL PROVIDE SHORING, BRACING AND SUPPORT AS REQUIRED TO MAINTAIN THE
SEALANT THROUGHOUT THE BUILDING FACADE. FOR BIDDING PURPOSES, CONTRACTOR SHALL ASSUME
15,000 LINEAR FEET OF SEALANT REPAIR SHALL BE PERFORMED.
4. STONE PANEL CRACK REPAIRS: CONTRACTOR SHALL REPAIR CRACKS IN THE STONE PANELS IN
ACCORDANCE WITH DETAILS 4 AND 5/R500.06 AND SPECIFICATION SECTION 04 01 40.91. FOR BIDDING STRUCTURAL INTEGRITY OF THE NEW OR EXISTING CONSTRUCTION DURING THE WORK. CONSTRUCTION Grady Memorial Hospital
DEBRIS SHALL BE REMOVED IN A MANNER THAT AVOIDS OVERLOADING ADJACENT STRUCTURAL MEMBERS.
UPPER LEVEL ELEVATION LABEL 17. SEALANT REPLACEMENT AT MISCELLANEOUS PENETRATIONS: CONTRACTOR SHALL INSTALL NEW SILICONE
SEALANT AT ALL THROUGH-WALL PENETRATIONS IN THE BUILDING FACADE THROUGHOUT THE PROPERTY, IN
PURPOSES, CONTRACTOR SHALL ASSUME 200 LINEAR FEET OF CRACK REPAIR THROUGHOUT THE WESTERN
ADDITION.
80 Jesse Hill Jr. Dr., SE
22. THE CONTRACTOR AND HIS RESPECTIVE SUBCONTRACTORS SHALL EACH HAVE FIVE OR MORE YEARS
ACCORDANCE WITH DETAIL 3/R500.06 AND SPECIFICATION SECTION 07 92 00. 5. STONE PANEL BUG HOLE REPAIRS: CONTRACTOR SHALL REPAIR BUG HOLES OR OTHER NATURAL EXPERIENCE PERFORMING REPAIR WORK SIMILAR IN SIZE, TYPE, AND COMPLEXITY TO WHAT IS SHOWN IN THE Atlanta, Georgia 30303
LOCATION MAP 18. SEALANT REPLACEMENT AT RE-ENTRANT CORNERS: CONTRACTOR SHALL INSTALL NEW SILICONE SEALANT
AT RE-ENTRANT CORNERS OF THE INFILL WALLS AT LOCATIONS IDENTIFIED ON THE BUILDING ELEVATIONS
DEPRESSIONS IN THE THIN STONE CLADDING EXCEEDING 1/4-INCH IN DEPTH WITH NEW STONE PATCHING
MATERIALS IN ACCORDANCE WITH DETAIL 6/R500.05 AND SPECIFICATION SECTION 04 01 40.91. FOR BIDDING
CONTRACT DOCUMENTS.

PURPOSES, CONTRACTOR SHALL ASSUME 100 PATCHES WILL BE INSTALLED THROUGHOUT THE WESTERN 23. ENFORCE STRICT DISCIPLINE AND GOOD ORDER AMONG EMPLOYEES. DO NOT EMPLOY UNFIT PERSONS OR
ON SHEETS R100.01 THROUGH 100.12. NEW SEALANT SHALL BE INSTALLED IN ACCORDANCE WITH DETAILS 1
ADDITION. PERSONS NOT SKILLED IN THE ASSIGNED TASK.
AND 2/R500.06 AND SPECIFICATION SECTION 07 92 00.
19. WINDOW REPLACEMENT: AT LOCATIONS IDENTIFIED ON THE BUILDING ELEVATIONS ON SHEETS R100.01 6. FACADE CLEANING: CONTRACTOR SHALL CLEAN ALL STONE PANEL CLADDING THROUGHOUT THE SOUTHERN 24. WHERE A DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE OR SIMILAR CONDITIONS, EVEN
THROUGH R100.12, CONTRACTOR SHALL REMOVE PLYWOOD PANELS FROM WINDOW OPENINGS AND INSTALL ADDITION FACADE IN ACCORDANCE WITH SPECIFICATION SECTION 04 01 20. CARE SHALL BE TAKEN TO THOUGH NOT SPECIFICALLY MARKED ON THE DRAWINGS.
WINDOW UNITS TO MATCH THE SURROUNDING WINDOW SYSTEMS. GLAZING FOR NEW WINDOW UNITS SHALL PREVENT DAMAGE OR ETCHING OF THE ALUMINUM WINDOW SYSTEMS, DECORATIVE PANELS, AND GLAZING
BE SPANDREL GLASS TO PROVIDE AN OPAQUE WALL PANEL AT THESE LOCATIONS. THROUGHOUT THE BUILDING. 25. ALL CONSTRUCTION SHALL BE SUBJECT TO REVIEW BY THE ARCHITECT/ENGINEER BEFORE IT IS CONCEALED
FROM VIEW. COORDINATE EXPECTED REVIEW ITEMS WITH THE ARCHITECT/ENGINEER PRIOR TO THE START OF
20. SUPPLEMENTAL WINDOW ANCHORAGE: CONTRACTOR SHALL INSTALL SUPPLEMENTAL WINDOW ANCHORAGE CONSTRUCTION AND PROVIDE REASONABLE NOTIFICATION TO THE ARCHITECT/ENGINEER TO ALLOW FOR
TO SELECT WINDOW UNITS, AS IDENTIFIED ON THE BUILDING ELEVATIONS ON SHEETS R100.01 THROUGH ALTERNATE NO. 4A - FOR THE SOUTH ADDITION, IN LIEU OF THE SEALANT REPLACEMENT IN ITEM 4.1 ABOVE, SUCH REVIEW AS THE WORK PROCEEDS.
R100.12. PRIOR TO INSTALLATION OF THESE REPAIRS, A/E SHALL EVALUATE THE EXISTING CONDITION OF INSPECT EXISTING SEALANTS AND REPLACE FAILED SEALANTS ONLY, INCLUDING: INSPECTION OF ALL EXISTING
THESE INDIVIDUAL WINDOW UNITS. SEALANTS, REMOVAL OF FAILED SEALANTS TO A HORIZONTAL OR VERTICAL PANEL JOINT OR TRANSITION, 26. REMOVE AND DISPOSE OF IN A PROPER MANNER (OFF-SITE) ALL EXISTING MATERIAL REMOVED FROM THE
SURFACE PREPARATION, AND NEW BACKER ROD AND SEALANT. FOR BIDDING PURPOSES, CONTRACTOR SHALL BUILDING DURING THE COURSE OF THE WORK ON A DAILY BASIS. REMOVAL AND DISPOSAL SHALL BE
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

21. FACADE CLEANING: CONTRACTOR SHALL CLEAN ALL EXPOSED CAST-IN-PLACE CONCRETE ELEMENTS, CAST SATISFACTORY TO THE ARCHITECT/ENGINEER AND OWNER
ASSUME 15,000 LINEAR FEET OF SEALANT REPLACEMENT AT THE WEST ADDITION. IF ACCEPTED, ALTERNATE 4A
STONE WINDOW SILLS AND COPINGS, AND BRICK MASONRY THROUGHOUT THE BUILDING FACADE IN BID PROVIDED SHALL REPLACE THE SEALANT REPLACEMENT INCLUDED IN ALTERNATE 4.
B B
ACCORDANCE WITH SPECIFICATION SECTION 04 01 20.52. CARE SHALL BE TAKEN TO PREVENT DAMAGE OR 27. CONTRACTOR SHALL COORDINATE USE OF PREMISES UNDER THE DIRECTION OF THE OWNER. TEMPORARY
ETCHING OF THE ALUMINUM WINDOW SYSTEMS, DECORATIVE PANELS, AND GLAZING THROUGHOUT THE DISRUPTIONS TO THE USE OF THE BUILDING BY EMPLOYEES AND PUBLIC, INCLUDING NOISE, DUST AND
BUILDING. Mark Date Description
DISRUPTION OF UTILITIES, SHALL BE COORDINATED A MINIUMUM OF 48 HOURS IN ADVANCE AND APPROVED BY
THE OWNER. CONTRACTOR WORK NOT COORDINATED IN ADVANCE WHICH CAUSES DISRUPTIONS TO THE USE 0 1/2" 1" 2"
OF THE BUILIDNG BY EMPLOYEES AND PUBLIC MAY BE STOPPED BY THE OWNER AND SHALL NOT BE
COMMENCED AGAIN UNTIL PROPER COORDINATION IS ACHIEVED. CONTRACTOR SHALL BE RESPONSIBLE FOR THIS SHEET PLOTS FULL SIZE
ALL COSTS RESULTING FROM WORK STOPPAGES OR DELAYS CAUSED BY CONTRACTORS LACK OF AT 30x42 (INCHES)

COORDINATION WITH THE OWNER.

28. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE WATER TIGHTNESS OF THE AREAS OF THE Project No. 2016.1879
STRUCTURE BEING WORKED ON DURING THE COURSE OF THE WORK. PROVIDE TEMPORARY PROTECTION OF
THE EXISTING CONSTRUCTION FROM THE WEATHER UNTIL REMOVED PORTIONS ARE COMPLETELY REPLACE Date 3/6/17
WITH NEW CONSTRUCTION. THE COST OF DAMAGE AND REPAIRS SHALL BE MADE AT NO COST TO THE OWNER.

29. THESE DRAWINGS AND SPECIFICATIONS APPLY TO THE PROJECT INDENTIFIED IN THE TITLEBLOCK ONLY AND
Drawn WL, KM
SHALL NOT BE USED FOR ANY OTHER PURPOSE WITHOUT THE EXPRESSED WRITTEN CONSENT OF WJE.
Checked LC
30. IN THE EVENT OF CONFLICT BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE MORE STRINGENT
REQUIREMENT AND BETTER QUALITY SHALL GOVERN UNLESS WRITTEN NOTIFICATION IS PROVIDED BY THE Scale As Noted
ARCHITECT/ENGINEER

31. THE SCOPE OF WORK COVERED UNDER THIS PROJECT INCLUDES THE COST OF HOISTING, SCAFFOLD,
A GRADY MEMORIAL HOSPITAL PEDESTRIAN PROTECTION, STORAGE, DEMOLITION, DISPOSAL, CONCRETE WORK, MASONRY, CARPENTRY, A
80 JESSE HILL JR. DRIVE, SE.
ATLANTA, GEORGIA 30303
LUMBER, MECHANICAL, ELECTRICAL, AND PLUMBING. Project Information
32. SAFETY IS THE RESPONSIBILITY OF THE CONTRACTOR, AND THE CONTRACTOR SHALL CONDUCT WORK IN FULL
AND COMPLETE ACCORDANCE WITH FEDERAL, STATE, AND LOCAL STATUTES, LAWS, AND ORDINANCES,
INCLUDING, BUT NOT LIMITED TO OSHA AND EPA.
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R000.01
1 2 3 4 5 6 7 8 9 10

Plan.dwg
Plotted: 3/20/2017 11:29 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R000.3 Site

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

O G
1

LY
R100.11

S IN
A
ARMSTRONG STREET SE 2016 ADDITION - NOT IN SCOPE

N
SE DD
1 1

I
R200.02 R200.03

PO B
G G

R R
PU FO
2 1 Consultants
R100.10
L R100.10

1
R100.02

K B

C
F F

PRATT STREET SE
2 1

JESSE HILL JR. DRIVE SE


R100.12 R100.12

2
R100.06
I 1
R100.09

4
R200.02

6 5
R100.11 R100.11 D
1
R100.05
1 3 4
R200.01 R100.11
R100.11

ELEVATION KEY
E E
A - SEE 1/R100.11 FOR ARMSTRONG STREET ENTRANCE FRONT AND SIDE
3 ELEVATIONS
R200.02

B - SEE 3/R100.12 FOR C-WING LIGHT WELL SOUTH ELEVATION


1
R100.06 C - SEE 4/R100.12 FOR C-WING LIGHT WELL EAST ELEVATION

H D - SEE 3/R100.07 FOR M-WING LIGHT EAST ELEVATION

WEST ADDITION E - SEE 3/R100.03 FOR D-WING LIGHT WELL EAST ELEVATION
1 2
R100.04 R100.04
F - SEE 4/R10.07 FOR O-WING SOUTH ELEVATION

G - SEE 2/R100.03 FOR A-WING LIGHT WELL WEST ELEVATION


E
G H - SEE 1/R100.07 FOR ELEVATIONS OF E-WING SOUTH COURTYARD
2 BUILDING
R100.08 1
R100.03
I - SEE 2/R100.09 FOR ELEVATIONS OF E-WING NORTH COURTYARD
BUILDING
Project
J - SEE 6/R100.12 FOR B-WING LIGHT WELL WEST ELEVATION
D 2 D
R100.07 K - SEE 5/R100.12 FOR B-WING LIGHT WELL SOUTH ELEVATION Grady Memorial Hospital
L - SEE 2/R100.11 FOR ARMSTRONG STREET LOW ROOF ELEVATIONS Facade Rehabilitation - Project
1 2 No. F2016008
R100.01 R100.01
80 Jesse Hill Jr. Dr., SE
F Atlanta, Georgia 30303
1
R100.08

2
R200.02

2
R300.02

Client
GILMER STREET SE
2
C R300.01 C
Grady Memorial Hospital
80 Jesse Hill Jr. Dr., SE
1
Atlanta, Georgia 30303
R300.01
SOUTH ADDITION
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B B

1 Mark Date Description


R300.02
0 1/2" 1" 2"

BUTLER PARKING DECK THIS SHEET PLOTS FULL SIZE


AT 30x42 (INCHES)

Project No. 2016.1879

Date 3/6/17

N Drawn KM

Site Plan Checked LC


1 SCALE: 1/32" = 1'-0"

Scale As Noted

A A
Site Plan
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R000.02
1 2 3 4 5 6 7 8 9 10

Building - A Wing Elevations.dwg


Plotted: 3/20/2017 11:29 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.1 Original

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

G
L
ORIGINAL BUILDING - D-WING

IN
N

D
WEST ADDITION - A-WING ORIGINAL BUILDING - A-WING

D
S

BI
EXISTING CAST STONE COPING - ROUT
G
EXISTING CAST STONE COPING - ROUT SEVENTEENTH FLOOR
AND SEAL ALL JOINTS IN ACCORDANCE
WITH DETAIL 4/R500.04, TYP. ROOF LEVEL
G

SE

R
AND SEAL ALL JOINTS IN ACCORDANCE 4

O
4 2 3 EXISTING CONCRETE LEDGE - SEE

FO
WITH DETAIL 4/R500.04, TYP. R500.04
R500.04 R500.04 R500.04 TYP. DETAIL 6/R500.04, TYP. EXISTING ALUMINUM-FRAMED VERTICAL
TYP.
TYP. RIBBON WINDOW SYSTEM - REMOVE AND
REPLACE PERIMETER SEALANT, TYP.
P
EJ SIXTEENTH FLOOR SIXTEENTH FLOOR
Consultants
R
EXISTING CAST STONE TRIM AT WINDOW
SURROUND FOR PUNCHED OPENINGS -
EXISTING METAL SPANDREL PANEL BETWEEN
VERTICAL RIBBON WINDOW SYSTEM, TYP.
P U
3 FIFTEENTH FLOOR FIFTEENTH FLOOR
R400.01 TYP. ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL 8/500.05, TYP., 2 3
EXISTING CAST STONE TRIM AT
SIM. R500.04 R500.04
WINDOW SURROUNDS FOR PUNCHED TYP.
OPENINGS - ROUT AND SEAL ALL FOURTEENTH FLOOR FOURTEENTH FLOOR
1 JOINTS IN ACCORDANCE WITH DETAIL SEE ELEVATION 2/R100.04 FOR WEST SC
V R400.01 TYP. 8/500.05, TYP., SIM. ELEVATION OF D-WING
EXISTING OVERFLOW SCUPPER -
EXISTING METAL SPANDREL PANEL 1 SEE DETAIL 3/R500.03
BETWEEN VERTICAL RIBBON WINDOW THIRTEENTH FLOOR R500.01 THIRTEENTH FLOOR
SC
F SYSTEM, TYP. F
EXISTING METAL PANEL WITHIN RIBBON TYP. EJ
WINDOW SYSTEM - CLEAN, PRIME, AND
PAINT, TYP.

TWELFTH FLOOR TWELFTH FLOOR


3 1
EXISTING CAST STONE WINDOW SILL - 2
TYP. R400.01 R400.01 TYP.
R400.01 EXISTING METAL PANEL WITHIN RIBBON
ROUT AND SEAL VERTICAL JOINTS IN
TYP. WINDOW SYSTEM - CLEAN, PRIME, AND
ACCORDANCE WITH DETAIL 8/R500.05,
PAINT, TYP.
TYP., SIM.
1
ELEVENTH FLOOR EXISTING CAST STONE WINDOW SILL - ELEVENTH FLOOR
R500.01
EXISTING ALUMINUM FRAMED RIBBON TYP. ROUT AND SEAL ALL JOINTS IN
WINDOW SYSTEM - REPLACE ACCORDANCE WITH DETAIL 8/R500.05,
PERIMETER SEALANT, TYP. TYP., SIM.
EXISTING ALUMINUM FRAMED RIBBON
TENTH FLOOR WINDOW SYSTEM - REMOVE AND TENTH FLOOR
2 REPLACE PERIMETER SEALANT, TYP.
EXISTING ALUMINUM-FRAMED R400.01
VERTICAL RIBBON WINDOW SYSTEM -
TYP.
REPLACE PERIMETER SEALANT, TYP. SEE ELEVATION 1/R100.05 FOR EAST
NINTH FLOOR ELEVATION OF D-WING NINTH FLOOR

E E

EIGHTH FLOOR EIGHTH FLOOR

4
R500.01 4 EXISTING MECHANICAL SYSTEM
TYP.
R500.01 LOUVERS TO REMAIN, TYP.
SEVENTH FLOOR TYP. SEVENTH FLOOR

SIX-A FLOOR SIX-A FLOOR


EXISTING MECHANICAL SYSTEM LOUVERS
TO REMAIN, TYP.

SIXTH FLOOR SIXTH FLOOR

SEE ELEVATION 1/R100.02 FOR WEST


ELEVATION OF F/G WING SEE ELEVATION 1/R100.05 FOR
EAST ELEVATION OF C-WING
SEE ELEVATION 1/R200.03 FOR EAST FIFTH FLOOR FIFTH FLOOR Project
ELEVATION OF WEST ADDITION
D D
F/G WING - SOUTH ELEVATION - Grady Memorial Hospital
SEE ELEVATION 1/R100.08 SEE ELEVATION 2/R100.07 FOR
FOURTH FLOOR EAST ELEVATION OF O-WING
FOURTH FLOOR
Facade Rehabilitation - Project
No. F2016008
F/G-WING AND O-WING PRATT STREET ENTRANCE
BUILDING INTERIOR 80 Jesse Hill Jr. Dr., SE
THIRD FLOOR THIRD FLOOR
Atlanta, Georgia 30303
EXISTING SHEET METAL COPING - SEAL
WEST ADDITION - SOUTH ELEVATION - JOINTS WITH PREFORMED SILICONE SHEET
SEE ELEVATION 2/R200.2 - SEE DETAIL 1/R500.04, TYP.
SECOND FLOOR SECOND FLOOR
EXISTING STEEL BEAM - SEAL ALL JOINTS
AND PAINT IN ACCORDANCE WITH
SPECIFICATION SECTION 09 97 13

FIRST FLOOR EXISTING CAST STONE COPING - ROUT FIRST FLOOR


Client
AND SEAL ALL JOINTS IN ACCORDANCE
EJ WITH DETAIL 4/R500.04, TYP.
C C
EXISTING STONE PANELS - ROUT AND SEAL Grady Memorial Hospital
JOINTS IN ACCORDANCE WITH DETAIL
GROUND FLOOR 8/R500.05, TYP. GROUND FLOOR 80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
EXISTING PAINTED WOOD PANEL - REPLACE
WITH NEW PREFINISHED ALUMINUM SHEET
METAL - ANCHORED WITH SCREWS AT 12
INCHES ON-CENTER WITH NEOPRENE
WASHERS - INSTALL NEW SILICONE SEALANT
AT PERIMETER

A WING - SOUTH ELEVATION SCOPE OF WORK SUMMARY:


D-WING - SOUTH ELEVATION SCOPE OF WORK SUMMARY:
1 SCALE: 1/16" = 1'-0"
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
2 SCALE: 1/16" = 1'-0"
1. SHELF ANGLE FLASHING REPAIR - SEE DETAIL 1 THROUGH 3/R500.01
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. SPOT REPOINTING - SEE DETAILS 7 THROUGH 9/R500.02 3. SPOT REPOINTING - SEE DETAILS 7 THROUGH 9/R500.02
4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 4. STEEL LINTEL AND METAL PANEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
5. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 5. SEALANT REPLACEMENT - SEE DETIALS 1 AND 2/R500.06
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
7. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04 7. CASE STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
B 8. CONCRETE LEDGE COATING REPAIRS - SEE DETAIL 6/R500.04 8. STONE PANEL REPAIRS - SEE SHEET R500.05 B
9. BUILDING TRANSITION SEALANT REPAIRS 9. EXPANSION JOINT SEALANT REPAIRS
Mark Date Description
0 1/2" 1" 2"

KEY PLAN KEY PLAN


THIS SHEET PLOTS FULL SIZE
AT 30x42 (INCHES)

Project No. 2016.1879

LEGEND Date 3/6/17


SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR Drawn WL, KM
THROUGH WALL FLASHING AND BASE OF
V MISCELLANEOUS VENT WALL REPAIRS
Checked LC
PP THROUGH WALL FLASHING REPAIRS
PIPE PENETRATION
NEW BACKER ROD AND SEALANT AT CAST STONE COPING - INSPECT AND REPAIR Scale As Noted
EJ
BUILDING TRANSITIONS AND EXPANSION
JOINTS CAST STONE WINDOW SILLS
A CAST-IN-PLACE CONCRETE - INSPECT AND
REPAIR SPALLS
SUPPLEMENTAL BRICK MASONRY ANCHORS TO
BE INSTALLED
A Original Building
RECONSTRUCT BRICK MASONRY Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.01
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:30 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.13 Original

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

ORIGINAL BUILDING - B-WING ORIGINAL BUILDING - A-WING

G
L

IN
N

D
O

D
CAST STONE COPING, TYP.
S

BI
CLEAN, PRIME, AND PAINT EXISTING PAINTED
G
EXISTING METAL PANEL INFILL - CLEAN, PRIME
STEEL LOUVERS, TYP. G

SE

R
AND PAINT - RE-ANCHOR PANELS WITH NEW CLEAN, PRIME, AND PAINT STEEL DOORS, TYP.

FO
METAL SCREWS WITH NEOPRENE FASTENERS
EXISTING CAST-IN-PLACE CONCRETE PROMENADE - REPAIR
CONCRETE SPALLS IN ACCORDANCE WITH DETAIL 8/R500.04 - COAT
ALL EXPOSED CONCRETE IN ACCORDANCE WITH SPECIFICATION
PENTHOUSE ROOF LEVEL
P
SECTION 09 97 24, TYP.
Consultants
R
EXISTING CAST STONE COPING - ROUT AND SEAL ALL JOINTS
IN ACCORDANCE WITH DETAIL 4/R500.04, TYP.
P U
ROOF LEVEL

EXISTING STEEL HANDRAILS - CLEAN, PRIME AND PAINT IN


ACCORDANCE WITH SPECIFICATION SECTION 09 97 13

SIXTEENTH FLOOR
EJ EJ EJ EJ

FIFTEENTH FLOOR
F F
EXISTING METAL PANEL WITHIN RIBBON WINDOW SYSTEM TO
REMAIN, TYP.

EXISTING ALUMINUM FRAMED RIBBON WINDOW SYSTEM - FOURTEENTH FLOOR


1
R400.01 TYP. REPLACE FAILED PERIMETER SEALANT IN ACCORDANCE
WITH DETAIL 2/R400.01, TYP.

EXISTING CAST STONE WINDOW SILL - ROUT AND SEAL JOINTS


IN ACCORDANCE WITH DETAIL 8/R500.05, TYP., SIM.
THIRTEENTH FLOOR

CLEAN, PRIME, AND PAINT EXISTING STEEL LINTELS AT


WINDOW HEAD, TYP.

EXISTING LEAD-COATED COPPER EXPANSION JOINT. SEE


DETAIL 3/R500.02, TYP., SIM. TWELFTH FLOOR
2 TYP.
R400.01
SIM.

SEE ELEVATION 2/R200.02 FOR SOUTH ELEVATION OF WEST


ADDITION
ELEVENTH FLOOR

E SEE ELEVATION 1/R200.02 FOR NORTH E


ELEVATION OF WEST ADDITION

TENTH FLOOR

SEE SHEET R200.02 FOR LIGHT WELL ELEVATIONS,


TYP.

NINTH FLOOR

ORIGINAL BUILDING - F/G WING


EIGHTH FLOOR

2 3
R500.04 R500.04
TYP.
SEVENTH FLOOR

EJ SIX-A FLOOR Project

D D
Grady Memorial Hospital
1
R500.01
TYP.
SIXTH FLOOR Facade Rehabilitation - Project
EXISTING THROUGH-WALL No. F2016008
SCUPPER. SEE DETAIL 3/R500.03,
TYP
FIFTH FLOOR
80 Jesse Hill Jr. Dr., SE
SC
Atlanta, Georgia 30303
PP
FOURTH FLOOR

WEST ADDITION - INTERIOR SPACE


4 NOT IN SCOPE
R500.01
THIRD FLOOR
TYP.
Client

C C

SECOND FLOOR
Grady Memorial Hospital
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
FIRST FLOOR

GROUND FLOOR
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

LEGEND

B B
SCOPE OF WORK SUMMARY: SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR
ORIGINAL BUILDING - WEST ELEVATION 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01 THROUGH WALL FLASHING AND BASE OF
1 SCALE: 1/16" = 1'-0" 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 V MISCELLANEOUS VENT
WALL REPAIRS Mark Date Description
3. BRICK MASONRY SUPPLEMENTAL ANCHORAGE REPAIRS - SEE DETAILS 2 THROUGH 5/R500.03 0 1/2" 1" 2"
PP PIPE PENETRATION THROUGH WALL FLASHING REPAIRS
4. SPOT REPOINTING - SEE DETAILS 7 THROUGH 9/R500.02
5. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 CAST STONE COPING - INSPECT AND REPAIR
NEW BACKER ROD AND SEALANT AT THIS SHEET PLOTS FULL SIZE
6. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 EJ AT 30x42 (INCHES)
BUILDING TRANSITIONS AND EXPANSION
7. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 CAST STONE WINDOW SILLS
JOINTS
8. BUILDING TRANSITION SEALANT REPAIRS
9. EXPANSION JOINT REPAIRS CAST-IN-PLACE CONCRETE - INSPECT AND SUPPLEMENTAL BRICK MASONRY ANCHORS TO Project No. 2016.1879
REPAIR SPALLS BE INSTALLED
KEY PLAN
RECONSTRUCT BRICK MASONRY Date 3/6/17

Drawn WL, KM

Checked LC

Scale As Noted

A A Original Building
Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.02
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:30 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.3 Original

ENGINEERS
ARCHITECTS
ORIGINAL BUILDING - E WING
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

EXISTING PAINTED WINDOW FRAMES EXISTING CAST STONE COPING, TYP.


AND GLAZING UNITS - CLEAN, PRIME,
AND PAINT

MECHANICAL PENTHOUSE - FACADE AREA


BEHIND EXISTING SIGNAGE - NOT IN SCOPE -
Y

G
PERFORM BASE OF WALL REPAIRS PER TWENTIETH FLOOR

IN
DETAIL 4/R500.01, TYP.
EXISTING CAST STONE COPING - ROUT
N

D
O
AND SEAL ALL JOINTS IN ACCORDANCE NINETEENTH FLOOR
WITH DETAIL 4/R500.04, TYP. EXISTING MECHANICAL SYSTEM

D
SC SC EXHAUST DUCT WORK TO REMAIN
4
S

BI
EXISTING THROUGH-WALL SCUPPER. INSTALL NEW BACKER ROD AND

E
R500.04
G SEE DETAIL 3/R500.03, TYP. SEALANT AT COPING-TO-MECHANICAL G
TYP.
DUCT INTERFACE
S

R
EIGHTEENTH FLOOR EXISTING LEAD-COATED COPPER
EJ EJ EJ
SC SC EXPANSION JOINT - SEE DETAIL

O
SC SC

FO
PP PP 3/R500.03, TYP.
CAST-IN-PLACE CONCRETE OVERHANG
EXISTING CAST STONE COPING -
4
R500.04
P
R
- SEE DETAIL 6/R500.04, TYP.
ROUT AND SEAL ALL JOINTS IN TYP.
SEVENTEENTH FLOOR Consultants

2 3
R500.04 R500.04
ACCORDANCE WITH DETAIL
4/R500.04, TYP.

EXISTING ALUMINUM FRAMED RIBBON


EJ
3
R400.01
SIM.
TYP.
1
R500.01
TYP.
EJ FOURTH FLOOR

P U
TYP. WINDOW SYSTEM - REPLACE PERIMETER
EJ SIXTEENTH FLOOR SEALANT IN ACCORDANCE WITH DETAIL
2/R400.01, TYP. THIRD FLOOR
2
TYP.
R400.01
EXISTING ARCHITECTURAL METAL PANEL
WITHIN RIBBON WINDOW SYSTEM TO BE
CLEANED, PRIMED, AND PAINTED, TYP. EJ FIFTEENTH FLOOR
EXISTING CAST STONE WINDOW SILL - SECOND FLOOR
EXISTING ALUMINUM FRAMED RIBBON ROUT AND SEAL ALL JOINTS IN
WINDOW SYSTEM - REPLACE FAILED ACCORDANCE WITH DETAIL 8/R500.05,
TYP., SIM. 4
PERIMETER SEALANT - SEE DETAIL R500.01
F FOURTEENTH FLOOR F
2/R400.01, TYP. TYP.
3
EXISTING CAST STONE WINDOW SILL TO R400.01 TYP.
BE COATED - ROUT AND SEAL ALL JOINTS
IN ACCORDANCE WITH DETAIL 8/R500.05, A-WING LIGHT WELL WEST ELEVATION
TYP., SIM. THIRTEENTH FLOOR 2 SCALE: 1/16" = 1'-0"

EXISTING CAST STONE LEDGES AT


WINDOW SURROUNDS FOR PUNCHED ORIGINAL BUILDING - A-WING - ORIGINAL BUILDING - D-WING -
OPENINGS - ROUT AND SEAL ALL JOINTS IN SOUTH ELEVATION - SEE 1/R100.01 SOUTH ELEVATION - SEE 2/R100.01 SCOPE OF WORK SUMMARY:
ACCORDANCE WITH DETAIL 3/R400.01, TYP.
TWELFTH FLOOR 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
EXISTING LEAD-COATED COPPER 4. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
EXPANSION JOINT - SEE DETAIL 3/R500.02, 5. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
TYP.
6. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
ELEVENTH FLOOR 7. EXPANSION JOINT REPAIRS
1
R400.01 TYP.
KEY PLAN

TENTH FLOOR
E E
EXISTING WOODEN PANEL AT WINDOW
OPENING - INSTALL NEW PREFINISHED
PANEL TO ACCOMODATE A/C UNIT TYP.
NINTH FLOOR

EXISTING THROUGH-WALL SCUPPER -


EXISTING CAST STONE COPING - ROUT SEE DETAIL 3/R500.03, TYP.
EIGHTH FLOOR AND SEAL ALL JOINTS IN ACCORDANCE 4
WITH DETAIL 4/R500.04, TYP. R500.04
2
TYP. TYP.
R400.01

EJ 1 EJ FOURTH FLOOR
SC R500.01
EXISTING LEAD-COATED COPPER 3 SIM.
SEVENTH FLOOR TYP.
EXPANSION JOINT - SEE DETAIL R400.01 TYP.
3/R500.02, TYP., SIM.
EXISTING MECHANICAL SYSTEM LOUVERS
TO REMAIN, TYP. 1 SIX-A FLOOR THIRD FLOOR
R500.01
TYP. 2
TYP.
R400.01

CLEAN, PRIME, AND PAINT EXISTING STEEL Project


DOORS, TYP.
D SIXTH FLOOR SECOND FLOOR D
EXISTING ALUMINUM FRAMED RIBBON
WINDOW SYSTEM - REPLACE PERIMETER Grady Memorial Hospital
SEALANT IN ACCORDANCE WITH DETAIL
2/R400.01, TYP. Facade Rehabilitation - Project
FIFTH FLOOR PP
EXISTING CAST STONE WINDOW SILL - FIRST FLOOR No. F2016008
EXISTING CAST STONE COPING, TYP. ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL 8/R500.05, 80 Jesse Hill Jr. Dr., SE
E TYP., SIM.
FOURTH FLOOR Atlanta, Georgia 30303
EJ EJ M M GROUND FLOOR

SEE ELEVATION 2/R100.03 FOR WEST 4


PP THIRD FLOOR R500.01
ELEVATION OF A-WING LIGHT WELL
TYP.

D-WING LIGHT WELL EAST ELEVATION


EXISTING STEEL STAIR ASSEMBLY TO BE 3 SCALE: 1/16" = 1'-0"
CLEANED, PRIMED, AND PAINTED
SECOND FLOOR Client

C C
SEE ELEVATION 3/R100.03 FOR EAST
ELEVATION OF D-WING LIGHT WELL
SCOPE OF WORK SUMMARY:
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
Grady Memorial Hospital
SOUTH COURTYARD - INTERIOR FIRST FLOOR
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
80 Jesse Hill Jr. Dr., SE
SEE ELEVATION 1/R100.04 FOR A-WING
SPACE - NOT IN SCOPE
SEE ELEVATION 2/R100.04 FOR
4. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
5. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 Atlanta, Georgia 30303
EAST ELEVATION D-WING WEST ELEVATION 6. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
7. REPLACE WOOD SPANDREL PANELS WITH NEW PREFINISHED ALUMINUM PANELS
8. EXPANSION JOINT REPAIRS
GROUND FLOOR
KEY PLAN

4
R500.01
TYP.

BASEMENT LEVEL
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

SCOPE OF WORK SUMMARY:


B 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01 B
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
E WING - SOUTH ELEVATION
1 SCALE: 1/16" = 1'-0"
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
4. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
Mark Date Description
0 1/2" 1" 2"
5. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
LEGEND
6. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
THIS SHEET PLOTS FULL SIZE
7. CONCRETE LEDGE COATING REPAIRS - SEE DETAIL 6/R500.04 AT 30x42 (INCHES)
8. REPLACE WOOD SPANDREL PANELS WITH NEW PREFINISHED ALUMINUM PANELS SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR
9. EXPANSION JOINT REPAIRS THROUGH WALL FLASHING AND BASE OF
V MISCELLANEOUS VENT WALL REPAIRS Project No. 2016.1879
PP PIPE PENETRATION THROUGH WALL FLASHING REPAIRS
Date 3/6/17
NEW BACKER ROD AND SEALANT AT CAST STONE COPING - INSPECT AND REPAIR
EJ
KEY PLAN BUILDING TRANSITIONS AND EXPANSION
JOINTS CAST STONE WINDOW SILLS Drawn WL, KM
CAST-IN-PLACE CONCRETE - INSPECT AND SUPPLEMENTAL BRICK MASONRY ANCHORS TO
REPAIR SPALLS BE INSTALLED Checked LC
RECONSTRUCT BRICK MASONRY
Scale As Noted

A A Original Building
Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.03
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:30 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.03 Original

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
ORIGINAL BUILDING - D WING 770.923.9822 tel | 770.232.9044 fax
ORIGINAL BUILDING - A WING www.wje.com

SEE 1/R100.03 FOR E-WING EXISTING CAST STONE COPING - ROUT


SEE 1/R100.03 FOR E-WING
AND SEAL ALL JOINTS IN ACCORDANCE

Y
SOUTH ELEVATION SOUTH ELEVATION

G
WITH DETAIL 4/R500.04, TYP.
EIGHTEENTH FLOOR EIGHTEENTH FLOOR
L

IN
EXISTING CAST STONE COPING - ROUT EXISTING CONCRETE SHADE SLAB TO BE EXISTING STEEL HANDRAILS - CLEAN,
N

D
AND SEAL ALL JOINTS IN ACCORDANCE

O
EXISTING CONCRETE SHADE COATED - SEE DETAIL 6/R500.04, TYP. PRIME, AND PAINT IN ACCORDANCE
WITH DETAIL 4/R500.04, TYP. SLAB TO BE COATED - SEE WITH SPECIFICATION SECTION 09 97 13

D
DETAIL 6/R500.04, TYP.

BI
EXISTING STEEL HANDRAILS - CLEAN, SEVENTEENTH FLOOR SEVENTEENTH FLOOR

E
EXISTING MECHANICAL
G PRIME, AND PAINT IN ACCORDANCE G
4 2 3 SYSTEM EXHAUST DUCT 3 2 EXISTING CAST STONE COPING, TYP.
4

S
WITH SPECIFICATION SECTION 09 97 13
WORK TO REMAIN

R
R500.04 R500.04 R500.04 R500.04 R500.04 R500.04
TYP. TYP.

O
TYP. TYP.

FO
SIXTEENTH FLOOR SIXTEENTH FLOOR

P
EXISTING THROUGH-WALL SCUPPER -
SEE DETAIL 3/R500.03, TYP. SC SC

Consultants
R
FIFTEENTH FLOOR FIFTEENTH FLOOR

P U
EXISTING CAST STONE TRIM AT WINDOW 1 FOURTEENTH FLOOR 1 EXISTING CAST STONE TRIM AT WINDOW FOURTEENTH FLOOR
SURROUNDS FOR PUNCHED OPENINGS - 3 R500.01 R500.01 3 SURROUNDS FOR PUNCHED OPENINGS -
ROUT AND SEAL ALL JOINTS IN R400.01 TYP. TYP. TYP. R400.01 TYP. ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL 8/R500.05, ACCORDANCE WITH DETAIL 8/R500.05,
TYP., SIM. TYP., SIM.
EXISTING METAL PANEL WITHIN RIBBON WINDOW THIRTEENTH FLOOR THIRTEENTH FLOOR
EXISTING METAL PANEL WITHIN RIBBON WINDOW
SYSTEM - CLEAN, PRIME, AND PAINT, TYP. SYSTEM TO REMAIN, TYP.
EXISTING ALUMINUM FRAMED RIBBON WINDOW EXISTING ALUMINUM FRAMED RIBBON WINDOW
F SYSTEM - REPLACE FAILED PERIMETER SEALANT. F
SYSTEM - REPLACE FAILED PERIMETER SEALANT
SEE DETAIL 2/R400.02, TYP. IN ACCORDANCE WITH DETAIL 2/R400.01, TYP.
TWELFTH FLOOR TWELFTH FLOOR
EXISTING CAST STONE WINDOW SILL - ROUT AND EXISTING CAST STONE WINDOW SILL - ROUT AND
SEAL ALL JOINTS IN ACCORDANCE WITH DETAIL SEAL ALL JOINTS IN ACCORDANCE WITH DETAIL
8/R500.05, TYP., SIM. 8/R500.05, TYP., SIM.

ELEVENTH FLOOR ELEVENTH FLOOR


1
CLEAN, PRIME, AND PAINT EXISTING EXPOSED R400.01 TYP.
STEEL LINTELS AT WINDOW HEAD, TYP.

EXISTING MECHANICAL SYSTEM LOUVERS TO TENTH FLOOR EXISTING MECHANICAL SYSTEM LOUVERS TO TENTH FLOOR
1
REMAIN, TYP. R400.01 TYP. REMAIN, TYP.

EXISTING LEAD-COATED COPPER EXPANSION EXISTING LEAD-COATED COPPER EXPANSION


JOINT - SEE DETAIL 3/500.02, TYP., SIM. JOINT - SEE DETAIL 3/500.02, TYP., SIM.
NINTH FLOOR NINTH FLOOR
EJ EJ
SEE ELEVATION 2/R100.08 FOR F/G
WING NORTH ELEVATION
E EIGHTH FLOOR EIGHTH FLOOR E
2 2
R400.01 R400.01
SEE DETAIL 2/R100.08 FOR F/G
TYP. TYP. WING NORTH ELEVATION

SEVENTH FLOOR SEVENTH FLOOR

SIX-A FLOOR SIX-A FLOOR

SIXTH FLOOR SIXTH FLOOR

FIFTH FLOOR FIFTH FLOOR

Project

D D
FOURTH FLOOR EJ FOURTH FLOOR Grady Memorial Hospital
Facade Rehabilitation - Project
THIRD FLOOR THIRD FLOOR
No. F2016008
PP 80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
SECOND FLOOR SECOND FLOOR

4
R500.01
TYP.
FIRST FLOOR FIRST FLOOR

ORIGINAL BUILDING - LOWER Client


LEVEL INTERIOR SPACE
C C
GROUND FLOOR GROUND FLOOR Grady Memorial Hospital
4
80 Jesse Hill Jr. Dr., SE
ORIGINAL BUILDING - LOWER R500.01
LEVEL INTERIOR SPACE
TYP.
Atlanta, Georgia 30303
BASEMENT LEVEL BASEMENT LEVEL

SCOPE OF WORK SUMMARY: SCOPE OF WORK SUMMARY:


A WING - EAST ELEVATION 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01 D WING - WEST ELEVATION 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
1 SCALE: 1/16" = 1'-0" 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 2 SCALE: 1/16" = 1'-0" 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. SEALANT REPLACEMENT - SEE SIMILAR DETAIL 8/R500.05 3. SEALANT REPLACEMENT - SEE SIMILAR DETAIL 8/R500.05
4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
5. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04 5. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
6. EXPANSION JOINT REPAIRS 6. EXPANSION JOINT REPAIRS
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B B
KEY PLAN KEY PLAN
Mark Date Description
0 1/2" 1" 2"

THIS SHEET PLOTS FULL SIZE


AT 30x42 (INCHES)

Project No. 2016.1879


LEGEND
Date 3/6/17
SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR
V MISCELLANEOUS VENT
THROUGH WALL FLASHING AND BASE OF Drawn WL, KM
WALL REPAIRS

PP PIPE PENETRATION
THROUGH WALL FLASHING REPAIRS Checked LC
NEW BACKER ROD AND SEALANT AT CAST STONE COPING - INSPECT AND REPAIR
EJ Scale As Noted
BUILDING TRANSITIONS AND EXPANSION
JOINTS CAST STONE WINDOW SILLS

A
CAST-IN-PLACE CONCRETE - INSPECT AND
REPAIR SPALLS
SUPPLEMENTAL BRICK MASONRY ANCHORS TO
BE INSTALLED A Original Building
RECONSTRUCT BRICK MASONRY
Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.04
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:30 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.04 Original

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

ORIGINAL BUILDING - D WING ORIGINAL BUILDING - C WING

G
L

IN
EXISTING CAST STONE COPING - ROUT AND SEAL ALL JOINTS
N

D
IN ACCORDANCE WITH DETAIL 4/R500.04, TYP.
O

D
EXISTING PAINTED STEEL LOUVERS
S

BI
G CLEAN, PRIME, AND PAINT STEEL DOORS, TYP.
EXISTING METAL PANEL INFILL - CLEAN, PRIME
G

SE

R
AND PAINT - RE-ANCHOR PANELS WITH NEW
EXISTING CAST-IN-PLACE CONCRETE COLUMNS - REPAIR
METAL SCREWS WITH NEOPRENE FASTENERS
O

FO
CONCRETE SPALLS IN ACCORDANCE WITH DETAIL 8/R500.04 - PAINT

P
ALL EXPOSED CONCRETE IN ACCORDANCE WITH SPECIFICATION
SECTION 09 97 24, TYP.

Consultants
R
U
EXISTING STEEL HANDRAILS - CLEAN, PRIME AND PAINT IN
ACCORDANCE WITH SPECIFICATION SECTION 09 97 13

P
EXISTING OVERFLOW SCUPPER -
SEE DETAIL 3/R500.03
ROOF LEVEL

EXISTING METAL PANEL WITHIN RIBBON WINDOW


SYSTEM TO REMAIN, TYP. SC SC SC SC SIXTEENTH FLOOR

EXISTING ALUMINUM FRAMED RIBBON WINDOW


SYSTEM - REPLACE FAILED PERIMETER SEALANT
FIFTEENTH FLOOR
F IN ACCORDANCE WITH DETAIL 2/R400.01, TYP. F
EXISTING CAST STONE WINDOW SILL - ROUT AND 2 3
R500.04 R500.04
SEAL ALL JOINTS IN ACCORDANCE WITH DETAIL TYP.
8/R500.05, TYP., SIM. FOURTEENTH FLOOR
CLEAN, PRIME, AND PAINT EXISTING EXPOSED
STEEL LINTELS AT WINDOW HEAD, TYP. 4
R500.04
TYP.
THIRTEENTH FLOOR
EXISTING CAST STONE TRIM AT WINDOW 1
SURROUNDS FOR PUNCHED OPENINGS - R400.01 TYP.
ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL 8/R500.05,
TYP., SIM.
TWELFTH FLOOR
EXISTING METAL SPANDREL PANEL BETWEEN
VERTICAL RIBBON WINDOW SYSTEM, TYP.

ELEVENTH FLOOR

E EXISTING ALUMINUM-FRAMED VERTICAL E


RIBBON WINDOW SYSTEM - REPLACE
FAILED PERIMETER SEALANT IN 1
ACCORDANCE WITH DETAIL 2/R400.01, R500.01 TENTH FLOOR
SIM., TYP. TYP.

NINTH FLOOR

EXISTING MECHANICAL SYSTEM LOUVERS TO


REMAIN, TYP.
3 SIM. EIGHTH FLOOR
R400.01 TYP.

ORIGINAL BUILDING - O WING


2 3
R500.04 R500.04
TYP. SEVENTH FLOOR

EJ EJ SIX-A FLOOR Project

D D
Grady Memorial Hospital
SIXTH FLOOR Facade Rehabilitation - Project
2
R400.01 No. F2016008
TYP.
80 Jesse Hill Jr. Dr., SE
FIFTH FLOOR
Atlanta, Georgia 30303
SC

FOURTH FLOOR

THIRD FLOOR
Client
4
C R500.01 C
TYP.
SECOND FLOOR
Grady Memorial Hospital
O-WING EAST ELEVATION -
SEE ELEVATION 2/R100.07 80 Jesse Hill Jr. Dr., SE
NEW BUILDING ADDITION
NOT IN SCOPE
Atlanta, Georgia 30303
FIRST FLOOR

M-WING EAST ELEVATION -


SEE ELEVATION 3/R100.07

GROUND FLOOR

BASEMENT LEVEL
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B B

Mark Date Description


0 1/2" 1" 2"

LEGEND THIS SHEET PLOTS FULL SIZE


AT 30x42 (INCHES)
SCOPE OF WORK SUMMARY:
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01 SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR
C AND D WING - EAST ELEVATION 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 THROUGH WALL FLASHING AND BASE OF
1 SCALE: 1/16" = 1'-0" 3. SPOT REPOINTING - SEE DETAILS 7 THROUGH 9/R500.02
V MISCELLANEOUS VENT
WALL REPAIRS
Project No. 2016.1879
4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
PP PIPE PENETRATION THROUGH WALL FLASHING REPAIRS Date 3/6/17
5. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 CAST STONE COPING - INSPECT AND REPAIR
NEW BACKER ROD AND SEALANT AT
7. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04 EJ Drawn WL, KM
BUILDING TRANSITIONS AND EXPANSION
8. CONCRETE LEDGE COATING REPAIRS - SEE DETAIL 6/R500.04 CAST STONE WINDOW SILLS
JOINTS
CAST-IN-PLACE CONCRETE - INSPECT AND SUPPLEMENTAL BRICK MASONRY ANCHORS TO Checked LC
REPAIR SPALLS BE INSTALLED
KEY PLAN Scale As Noted
RECONSTRUCT BRICK MASONRY

A A Original Building
Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.05
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:30 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.05 Original

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

ORIGINAL BUILDING - D WING C-WING

G
L

IN
N

D
O

D
S

BI
G
SIXTEENTH FLOOR SIXTEENTH FLOOR
G

SE

R
O

FO
EXISTING OVERFLOW SCUPPER -

FIFTEENTH FLOOR
SEE DETAIL 3/R500.03, TYP.
FIFTEENTH FLOOR
P
4 4 Consultants
R
EXISTING OVERFLOW SCUPPER - SEE DETAIL
3/R500.03, TYP.
R500.04
TYP.
FOURTEENTH FLOOR
R500.04
TYP.
FOURTEENTH FLOOR
P U
SC SC
TYP.
EXISTING CAST STONE COPING - ROUT AND 3 2 2 3 EXISTING CAST STONE COPING - ROUT AND
R500.04 R500.04 R500.04 R500.04
SEAL ALL JOINTS IN ACCORDANCE WITH TYP. SEAL ALL JOINTS IN ACCORDANCE WITH
DETAIL 4/R500.04, TYP. DETAIL 4/R500.04, TYP.
THIRTEENTH FLOOR THIRTEENTH FLOOR
EXISTING METAL PANEL WITHIN RIBBON WINDOW SC SC
SYSTEM - CLEAN, PRIME, AND PAINT, TYP.

EXISTING ALUMINUM FRAMED RIBBON WINDOW


SYSTEM - REPLACE FAILED PERIMETER SEALANT TWELFTH FLOOR TWELFTH FLOOR
- SEE DETAIL 2/R400.01, TYP.
F F
EXISTING METAL PANEL WITHIN RIBBON
EXISTING CAST STONE WINDOW SILL - ROUT AND WINDOW SYSTEM TO REMAIN - CLEAN,
SEAL ALL JOINTS IN ACCORDANCE WITH DETAIL PRIME, AND PAINT, TYP.
8/R500.05, TYP., SIM.
ELEVENTH FLOOR ELEVENTH FLOOR
EXISTING CAST STONE WINDOW SILL -
ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL 8/R500.05,
TYP., SIM.
TENTH FLOOR 2 TENTH FLOOR
R400.01 EXISTING ALUMINUM FRAMED RIBBON
TYP. WINDOW SYSTEM - REPLACE FAILED
PERIMETER SEALANT IN ACCORDANCE
WITH DETAIL 2/R400.01, TYP.
1
R500.01 NINTH FLOOR NINTH FLOOR
1 SEE ELEVATION 1/R100.05 FOR EAST
TYP. R400.01 TYP. ELEVATION OF C-WING

EXISTING MECHANICAL SYSTEM LOUVERS TO EIGHTH FLOOR EIGHTH FLOOR


REMAIN, TYP.

E E
1
R500.01
SEVENTH FLOOR SEVENTH FLOOR
TYP.

SIX-A FLOOR SIX-A FLOOR


2
R400.01
TYP.

SIXTH FLOOR 1 SIXTH FLOOR


R400.01 TYP.

FIFTH FLOOR FIFTH FLOOR

SEE ELEVATION 1/R100.05 FOR EAST ELEVATION OF


D-WING

FOURTH FLOOR FOURTH FLOOR Project

D D

EXISTING STEEL ANTENNA


Grady Memorial Hospital
THIRD FLOOR ANCHORAGES TO BE CLEANED PRIMED
AND PAINTED
THIRD FLOOR
Facade Rehabilitation - Project
4
R500.01
4 No. F2016008
R500.01
TYP.
SECOND FLOOR TYP. SECOND FLOOR
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
ORIGINAL BUILDING INTERIOR ORIGINAL BUILDING INTERIOR
SPACE - NOT IN SCOPE SPACE - NOT IN SCOPE

Client

C C
D-WING - NORTH ELEVATION C-WING - SOUTH ELEVATION Grady Memorial Hospital
1 SCALE: 1/16" = 1'-0" 2 SCALE: 1/16" = 1'-0"

80 Jesse Hill Jr. Dr., SE


SCOPE OF WORK SUMMARY: SCOPE OF WORK SUMMARY: Atlanta, Georgia 30303
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04 3. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
5. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 5. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52

KEY PLAN KEY PLAN


Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B B

Mark Date Description


0 1/2" 1" 2"

LEGEND
THIS SHEET PLOTS FULL SIZE
AT 30x42 (INCHES)
SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR
THROUGH WALL FLASHING AND BASE OF
V MISCELLANEOUS VENT Project No. 2016.1879
WALL REPAIRS

PP PIPE PENETRATION THROUGH WALL FLASHING REPAIRS


Date 3/6/17
NEW BACKER ROD AND SEALANT AT CAST STONE COPING - INSPECT AND REPAIR
EJ
BUILDING TRANSITIONS AND EXPANSION
CAST STONE WINDOW SILLS
Drawn WL, KM
JOINTS
CAST-IN-PLACE CONCRETE - INSPECT AND SUPPLEMENTAL BRICK MASONRY ANCHORS TO Checked LC
REPAIR SPALLS BE INSTALLED
RECONSTRUCT BRICK MASONRY Scale As Noted

A A Original Building
Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.06
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:31 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.06 Original

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

G
L

IN
N

D
O

D
S

BI
EXISTING ALUMINUM FRAMED WINDOW SYSTEM - EXISTING CAST-IN-PLACE CONCRETE EXISTING CAST-IN-PLACE CONCRETE
G REPLACE FAILED PERIMETER SEALANT IN
ACCORDANCE WITH DETAIL 2/R400.01, TYP. 4
R500.04
LEDGE - ROUT AND SEAL CRACKS - CLEAN,
PRIME, AND COAT 4
LEDGE - ROUT AND SEAL CRACKS -
CLEAN, PRIME, AND COAT
ORIGINAL BUILDING - O WING EXISTING OVERFLOW SCUPPER -
SEE DETAIL 3/R500.04
G

SE

R
R500.04
TYP. ROOF LEVEL TYP. ROOF LEVEL 4
O

FO
EXISTING CAST STONE
PP R500.01
COPING, TYP.
PP
TYP.
P
FOURTH FLOOR FOURTH FLOOR EJ SC SC EJ LOW ROOF LEVEL
Consultants
R
EXISTING CAST STONE WINDOW SILL - ROUT AND
SEAL ALL JOINTS IN ACCORDANCE WITH DETAIL
4
TYP.
R500.01 EAST ELEVATION
CLEAN, PRIME, AND PAINT EXISTING STEEL
LINTELS AT WINDOW HEAD, TYP.
4
R500.01 SOUTH ELEVATION
MECHANICAL SYSTEM PENETRATION -
SEAL PERIMETER IN ACCORDANCE WITH
EXISTING LEAD-COATED
EXPANSION JOINT BETWEEN
O-WING AND D-WING - SEE DETAIL 3
P U
8/R500.05, TYP., SIM. TYP. DETAIL 3/R500.06, TYP. THROUGH 6/R500.02, SIM.
THIRD FLOOR
2 EXISTING ALUMINUM FRAMED
R400.01 RIBBON WINDOW SYSTEM -
TYP. REPLACE FAILED PERIMETER
SEALANT. SEE 2/R400.01
SECOND FLOOR
1
EXISTING METAL PANEL TO BE
TYP. R400.01
CLEANED, PRIMED, AND PAINTED,
TYP.
F CAST STONE WINDOW SILL AND F
ACCENT BAND - ROUT AND SEAL FIRST FLOOR
EXISTING CAST-IN-PLACE CONCRETE EXISTING ALUMINUM FRAMED EXISTING CAST-IN-PLACE CONCRETE
LEDGE - ROUT AND SEAL ALL JOINTS IN WINDOW SYSTEM - REPLACE FAILED LEDGE - ROUT AND SEAL CRACKS - ALL JOINTS IN ACCORDANCE
4 4 EXISTING BUILDING TO BE WITH DETAIL 8/R500.05, TYP., SIM.
ACCORDANCE WITH DETAIL 4/R500.04, TYP. PERIMETER SEALANT IN CLEAN, PRIME, AND COAT
R500.04 R500.04 DEMOLISHED - NOT IN SCOPE
- CLEAN, PRIME, AND COAT ACCORDANCE WITH DETAIL
TYP. ROOF LEVEL TYP. ROOF LEVEL GRANITE PANELS AND COLUMN
2/R400.01, TYP.
CLADDING - ROUT AND SEAL
LF GROUND FLOOR
JOINTS - SEE DETAIL 8/R500.05

EXISTING STEEL PLUMBING TO REMAIN, TYP. FOURTH FLOOR FOURTH FLOOR PREFINISHED ALUMINUM CLAD ENTRANCE CANOPY TO
BE CLEANED

CLEAN, PRIME, AND PAINT EXISTING STEEL 4 EXISTING CAST STONE WINDOW 4 CLEAN, PRIME, AND PAINT EXISTING STEEL ALUMINUM FRAMED STOREFRONT ENTRANCE - INSPECT
LINTELS AND EXPOSED STEEL ELEMENTS, TYP. NORTH ELEVATION R500.01 SILL - ROUT AND SEAL AL JOINTS R500.01 LINTELS AT WINDOW HEAD, TYP. AND REPLACE PERIMETER SEALANT AS NECESSARY
WEST ELEVATION
TYP. IN ACCORDANCE WITH DETAIL TYP.
8/R500.05, TYP., SIM.

E-WING S. COURTYARD BUILDING ELEVATIONS O WING - EAST ELEVATION


1 SCALE: 1/16" = 1'-0" 2 SCALE: 1/16" = 1'-0"

E E
SCOPE OF WORK SUMMARY: SCOPE OF WORK SUMMARY:
1. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2. BRICK MASONRY SEALANT REPLACEMENT - SEE DETAIL 8/R500.05 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 3. SPOT REPOINTING - SEE DETAILS 7 THROUGH 9/R500.02
4. WINDOW PERIMETER SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
5. CAST STONE JOINT REPAIR - SEE DETAIL 8/R500.05 5. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
7. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
8. STONE PANEL REPAIRS - SEE SHEET R500.05
KEY PLAN 9. EXPANSION JOINT REPAIRS KEY PLAN

ORIGINAL BUILDING - O WING

Project

D D
EXISTING METAL FENCING - CLEAN,
PRIME, AND PAINT
Grady Memorial Hospital
SEVENTH FLOOR Facade Rehabilitation - Project
EXISTING LEAD-COATED COPPER
EXPANSION JOINT - SEE DETAIL
3/R500.02, TYP. EXISTING CAST STONE COPING, TYP.
No. F2016008
EXISTING SHEET METAL COPING - SEAL SIX-A FLOOR
JOINTS WITH PREFORMED SILICONE 80 Jesse Hill Jr. Dr., SE
SHEET - SEE DETAIL 1/R500.04, TYP.
ROOF LEVEL SC SC SC SC Atlanta, Georgia 30303
EJ EXISTING STEEL BEAM. SEAL JOINTS IN SIXTH FLOOR
BEAM WITH SILYL-TERMINATED
POLYURETHANE SEALANT AND CLEAN,
PRIME, AND PAINT IN ACCORDANCE EXISTING OVERFLOW SCUPPER -
FIRST FLOOR WITH SPECIFICATION SECTION 09 97 13. SEE DETAIL 3/R500.04
V FIFTH FLOOR

EXISTING METAL PANELS, TYP. 3 2 4 EXISTING CAST STONE


R500.04 R500.04 R500.04 COPING - ROUT AND SEAL ALL
TYP.
JOINTS IN ACCORDANCE WITH Client
GROUND FLOOR FD
1 DETAIL 4/R500.04, TYP.
C FD TYP. R500.01 C
SC TYP.
FOURTH FLOOR
Grady Memorial Hospital
SOUTH ADDITION - H-WING
EXISTING MARBLE
CLADDING, TYP.
EXISTING MARBLE CLAD
COLUMNS, TYP..
BUILDING INTERIOR EXISTING ALUMINUM FRAMED 80 Jesse Hill Jr. Dr., SE
RIBBON WINDOW SYSTEM -
1 REPLACE FAILED PERIMETER
THIRD FLOOR Atlanta, Georgia 30303
R400.01 TYP. SEALANT. SEE 2/R400.01

EXISTING CAST STONE WINDOW


M-WING - EAST ELEVATION SILL - ROUT AND SEAL ALL JOINTS
3 SCALE: 1/16" = 1'-0" IN ACCORDANCE WITH DETAIL SECOND FLOOR
SCOPE OF WORK SUMMARY: 8/R500.05, TYP., SIM.
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01 2 EXISTING METAL PANEL TO BE
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 R400.01 CLEANED, PRIMED, AND PAINTED,
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 TYP. TYP.
4. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
5. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 EXISTING MECHANICAL SYSTEM
LOUVERS TO REMAIN, TYP. FIRST FLOOR
6. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
7. STONE PANEL REPAIRS - SEE SHEET R500.05
PP PP
8. EXPANSION JOINT REPAIRS
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without

REMOVE, STORE, AND REINSTALL


permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

SECURITY CAMERAS DURING REPAIRS GROUND FLOOR


B B
KEY PLAN
Mark Date Description
EXISTING ROOF INTERFACE - STEP
0 1/2" 1" 2"
FLASHING AND LAP ONTO ROOF MEMBRANE

THIS SHEET PLOTS FULL SIZE


AT 30x42 (INCHES)

O WING - SOUTH ELEVATION


LEGEND 4 SCALE: 1/16" = 1'-0" Project No. 2016.1879
SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR
THROUGH WALL FLASHING AND BASE OF Date 3/6/17
V MISCELLANEOUS VENT SCOPE OF WORK SUMMARY:
WALL REPAIRS
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01 Drawn WL, KM
PP PIPE PENETRATION THROUGH WALL FLASHING REPAIRS 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. SPOT REPOINTING - SEE DETAILS 7 THROUGH 9/R500.02
NEW BACKER ROD AND SEALANT AT CAST STONE COPING - INSPECT AND REPAIR
4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 Checked LC
EJ
BUILDING TRANSITIONS AND EXPANSION 5. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
JOINTS CAST STONE WINDOW SILLS
6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 Scale As Noted
CAST-IN-PLACE CONCRETE - INSPECT AND SUPPLEMENTAL BRICK MASONRY ANCHORS TO 7. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
REPAIR SPALLS BE INSTALLED 8. STONE PANEL REPAIRS - SEE SHEET R500.05

A RECONSTRUCT BRICK MASONRY


9. EXPANSION JOINT REPAIRS
KEY PLAN A Original Building
Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.07
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:31 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.07 Original

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

G
L

IN
N

D
O

D
S

BI
G G

SE

R
O

FO
ORIGINAL BUILDING - F/G WING
P
ORIGINAL BUILDING - F/G WING SOUTH ADDITION - H-WING Consultants
R
EXISTING CAST STONE
COPING - ROUT AND SEAL ALL
P U
JOINTS IN ACCORDANCE WITH
DETAIL 4/R500.04, TYP.
4 2 3 4
EXISTING CAST STONE COPING - ROUT R500.04 R500.04 R500.04 TYP. R500.04
AND SEAL ALL JOINTS IN ACCORDANCE TYP. TYP.
ROOF LEVEL EXISTING LEAD-COATED ROOF LEVEL
WITH DETAIL 4/R500.04, TYP. COPPER EXPANSION JOINT -
SEE DETAIL 3/R500.02, TYP.,
EJ SIM.
EJ EJ
EIGHTH FLOOR SC SC SC EIGHTH FLOOR
2 TYP.
F EXISTING LEAD-COATED COPPER EXISTING ALUMINUM FRAMED F
2 3 R400.01
EXPANSION JOINT - SEE DETAIL WINDOW SYSTEM - REPLACE
R500.04 R500.04
3/R500.02, TYP. TYP. FAILED PERIMETER SEALANT
IN ACCORDANCE WITH
SEVENTH FLOOR DETAIL 2/R400.01, TYP. SEVENTH FLOOR
EJ SC
EXISTING METAL PANEL WITHIN RIBBON 1
WINDOW SYSTEM TO REMAIN, TYP. SIX-A FLOOR R500.01 SIX-A FLOOR
TYP.
EXISTING CAST STONE WINDOW
EXISTING CAST STONE WINDOW SILL - SILL - ROUT AND SEAL ALL
ROUT AND SEAL VERTICAL JOINTS IN JOINTS IN ACCORDANCE WITH
ACCORDANCE WITH DETAIL 8/R500.05, 1 DETAIL 8/R500.05, TYP., SIM.
SIXTH FLOOR SIXTH FLOOR
TYP., SIM. R500.01
1
EXISTING ALUMINUM FRAMED RIBBON TYP. R400.01 TYP.
WINDOW SYSTEM - REPLACE FAILED
PERIMETER SEALANT IN ACCORDANCE
WITH DETAIL 2/R400.01, TYP. FIFTH FLOOR FIFTH FLOOR
INSTALL PREFORMED
CLEAN, PRIME, AND PAINT EXISTING 2 SILICONE SEALANT AT
EXPOSED STEEL LINTELS AT WINDOW R400.01 SURFACE MOUNTED
HEAD, TYP. LOUVER FLANGES, TYP.
E TYP. E
SEE ELEVATION 2/R300.01 FOR WEST FOURTH FLOOR FOURTH FLOOR
ELEVATION OF SOUTH ADDITION EJ EJ
EXISTING LEAD-COATED
COPPER EXPANSION SEE ELEVATION 2/R100.03 FOR
4 JOINT - SEE DETAIL WEST ELEVATION OF A- WING
R500.01 THIRD FLOOR LIGHT WELL THIRD FLOOR
3/R500.02, TYP.
TYP.

SOUTH ADDITION - H-WING - INTERIOR - SECOND FLOOR ORIGINAL BUILDING - A-WING, D-WING, SECOND FLOOR
NOT IN SCOPE OF WORK AND COURTYARD INTERIOR SPACE
EXISTING MECHANICAL
SYSTEM EXHAUST DUCT 4
R500.01
WORK TO REMAIN, TYP.
TYP.
FIRST FLOOR SEE ELEVATION 3/R100.03 FIRST FLOOR
FOR EAST COURTYARD
ELEVATION D- WING LIGHT
WELL
Project
CLEAN, PRIME, AND PAINT
D GROUND FLOOR GROUND FLOOR D
STEEL DOORS, TYP.
Grady Memorial Hospital
Facade Rehabilitation - Project
BASEMENT LEVEL BASEMENT LEVEL No. F2016008
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
F-G WING - SOUTH ELEVATION F-G WING - NORTH ELEVATION
1 SCALE: 1/16" = 1'-0" 2 SCALE: 1/16" = 1'-0"
SCOPE OF WORK SUMMARY: SCOPE OF WORK SUMMARY:
1. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 1. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
2. BRICK MASONRY SEALANT REPLACEMENT - SEE DETAIL 8/R500.05 2. BRICK MASONRY SEALANT REPLACEMENT - SEE DETAIL 8/R500.05
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
4. WINDOW PERIMETER SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 4. WINDOW PERIMETER SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
5. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04 5. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
7. EXPANSION JOINT REPAIRS 7. EXPANSION JOINT REPAIRS
Client

C KEY PLAN C
KEY PLAN Grady Memorial Hospital
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B B

Mark Date Description


0 1/2" 1" 2"

THIS SHEET PLOTS FULL SIZE


AT 30x42 (INCHES)
LEGEND

SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR Project No. 2016.1879
THROUGH WALL FLASHING AND BASE OF
V MISCELLANEOUS VENT
WALL REPAIRS Date 3/6/17
PP PIPE PENETRATION THROUGH WALL FLASHING REPAIRS
Drawn WL, KM
NEW BACKER ROD AND SEALANT AT CAST STONE COPING - INSPECT AND REPAIR
EJ
BUILDING TRANSITIONS AND EXPANSION Checked LC
JOINTS CAST STONE WINDOW SILLS

CAST-IN-PLACE CONCRETE - INSPECT AND SUPPLEMENTAL BRICK MASONRY ANCHORS TO Scale As Noted
REPAIR SPALLS BE INSTALLED
RECONSTRUCT BRICK MASONRY
A A Original Building
Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.08
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:31 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.08 Original

ORIGINAL BUILDING - E WING


ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
SC SC TWENTIETH FLOOR
2915 Premiere Parkway, Suite 100
EXISTING CAST STONE COPING - ROUT Duluth, Georgia 30097
AND SEAL ALL JOINTS IN ACCORDANCE
770.923.9822 tel | 770.232.9044 fax
WITH DETAIL 4/R500.04, TYP. NINETEENTH FLOOR www.wje.com

4
R500.04
PP
TYP.

SC SC EIGHTEENTH FLOOR

G
INSTALL NEW BACKER ROD AND

L
SEALANT AT COPING-TO-MECHANICAL

IN
DUCT INTERFACE 2 3

N
R500.04 R500.04
TYP.
SEVENTEENTH FLOOR

D
O

D
EXISTING ROOF OVERFLOW
SCUPPER - SEE DETAIL 3/R500.03,
S

BI
TYP.
G
EXISTING MECHANICAL SYSTEM
SIXTEENTH FLOOR G

SE

R
EXHAUST DUCT WORK TO REMAIN

FO
FIFTEENTH FLOOR
P
Consultants
R
EXISTING METAL PANEL TO BE
CLEANED, PRIMED, AND PAINTED, TYP. FOURTEENTH FLOOR
P U
EXISTING ALUMINUM FRAMED RIBBON
WINDOW SYSTEM - REPLACE FAILED
PERIMETER SEALANT. SEE DETAIL 1
2/R400.01, TYP. R500.01 THIRTEENTH FLOOR
TYP.
EXISTING CAST STONE WINDOW SILL -
ROUT AND SEAL ALL JOINTS. SEE DETAIL
8/R500.05, TYP., SIM.

EXISTING CAST STONE TRIM TWELFTH FLOOR


1
SURROUNDING PUNCHED OPENINGS - R400.01 TYP.
F F
ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL 3/R400.01, TYP.

ELEVENTH FLOOR

ORIGINAL BUILDING - C-WING - ORIGINAL BUILDING - B-WING -


NORTH ELEVATION - SEE 1/R100.10 NORTH ELEVATION - SEE 2/R100.10
TENTH FLOOR

NINTH FLOOR
PP

EIGHTH FLOOR

E E
SEVENTH FLOOR

SIX-A FLOOR

SIXTH FLOOR

SEE ELEVATION 2/R100.09 FOR


BUILDING ELEVATION
FIFTH FLOOR

EXISTING SHEET METAL COPING - SEAL EXISTING MECHANICAL


JOINTS WITH PREFORMED SILICONE SYSTEM EXHAUST DUCT WORK
SHEET - SEE DETAIL 1/R500.04, TYP. TO REMAIN
PP FOURTH FLOOR
Project
EJ EJ EXISTING SHEET METAL
D EXISTING LEAD-COATED COPPER COPING D
EXPANSION JOINT - SEE DETAIL
3/R500.02, TYP., SIM.
Grady Memorial Hospital
THIRD FLOOR
2
TYP. EXISTING SURFACE MOUNTED LIGHT
SEE ELEVATION 6/R100.12
FOR B-WING LIGHT WELL
Facade Rehabilitation - Project
R400.01
FIXTURE - SEE DETAIL 3/R500.06, TYP. WEST ELEVATION
No. F2016008
SEE ELEVATION 2/R100.03 FOR A-WING EXISTING STEEL DOOR - CLEAN,
LIGHT WELL EAST ELEVATION PRIME, AND PAINT SECOND FLOOR 80 Jesse Hill Jr. Dr., SE
EXISTING SHEET METAL COVER Atlanta, Georgia 30303

EMERGENCY VEHICLE ENTRANCE - FIRST FLOOR


SEE ELEVATION 1/R100.1
4
R500.01
TYP. SCOPE OF WORK SUMMARY:
GROUND FLOOR 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 Client
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
C 4. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 C
5. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
6. CAST STONE SILL AND COPING REPAIRS - SEE SHEET 6/R500.04
Grady Memorial Hospital
BASEMENT LEVEL
7. EXPANSION JOINT REPAIRS 80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
KEY PLAN

E-WING - NORTH ELEVATION


1 SCALE: 1/16" = 1'-0"

ROOF OVERFLOW SCUPPER - SEE DETAIL


3/R500.03, TYP.
EXISTING EXPANSION JOINT - SEE DETAILS 3
THROUGH 6/R500.02, TYP. EXISTING CAST STONE COPING - ROUT AND
SEAL ALL JOINTS IN ACCORDANCE WITH
SUPPLEMENTAL BRICK EXISTING CAST STONE COPING - ROUT AND EXISTING CAST STONE COPING - ROUT AND DETAIL 4/R500.04, TYP.
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

MASONRY ANCHORS TO SEAL ALL JOINTS IN ACCORDANCE WITH SEAL ALL JOINTS IN ACCORDANCE WITH
DETAIL 4/R500.04, TYP. 4 DETAIL 8/R500.04, TYP., SIM. 4
B BE INSTALLED, TYP. - B
R500.04 R500.04
SEE DETAIL 2/R500.03
ROOF LEVEL TYP. ROOF LEVEL TYP. ROOF LEVEL
TYP. Mark Date Description
2 EJ 2
R400.01 SC SC EJ R400.01 TYP.
0 1/2" 1" 2"

PP PP PP
PP
THIS SHEET PLOTS FULL SIZE
FOURTH FLOOR FOURTH FLOOR FOURTH FLOOR AT 30x42 (INCHES)

TYP.
4 EXISTING STEEL DOOR TO BE 4 EXISTING CAST STONE WINDOW SILL - ROUT EXISTING CAST STONE WINDOW SILL - ROUT AND 4 CLEAN, PRIME, AND PAINT EXISTING STEEL Project No. 2016.1879
R500.01 R500.01 SEAL ALL JOINTS IN ACCORDANCE WITH DETAIL R500.01
CLEANED, PRIMED AND PAINTED - AND SEAL ALL JOINTS IN ACCORDANCE WITH ELEMENTS, TYP.
TYP. NORTH ELEVATION EAST ELEVATION WEST ELEVATION TYP.
REPLACE CRACKED GLAZING DETAIL 8/R500.05, TYP., SIM. 8/R500.05, TYP., SIM.
LEGEND Date 3/6/17

SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR Drawn WL, KM
THROUGH WALL FLASHING AND BASE OF
V MISCELLANEOUS VENT
SCOPE OF WORK SUMMARY: WALL REPAIRS Checked LC
E-WING N. COURTYARD BUILDING ELEVATIONS 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2 SCALE: 1/16" = 1'-0" 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
PP PIPE PENETRATION THROUGH WALL FLASHING REPAIRS
Scale As Noted
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 NEW BACKER ROD AND SEALANT AT CAST STONE COPING - INSPECT AND REPAIR
4. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 EJ
BUILDING TRANSITIONS AND EXPANSION
5. REMOVE ABANDONED ANTENNAE FROM EAST ELEVATION JOINTS CAST STONE WINDOW SILLS
A 6. REPLACE CRACKED GLAZING AT STEEL DOOR ON EAST ELEVATION
7. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
CAST-IN-PLACE CONCRETE - INSPECT AND SUPPLEMENTAL BRICK MASONRY ANCHORS TO
A Original Building
REPAIR SPALLS BE INSTALLED
8. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
RECONSTRUCT BRICK MASONRY Elevations
KEY PLAN

Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.09
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:31 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.09 Original

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

G
L

IN
ORIGINAL BUILDING -C WING B-WING

D
O

D
S

BI
4
G
SEVENTEENTH FLOOR
R500.04
TYP. SEVENTEENTH FLOOR
G

SE

R
EXISTING ALUMINUM-FRAMED EXISTING ALUMINUM-FRAMED
EXISTING CAST STONE
O

FO
VERTICAL RIBBON WINDOW VERTICAL RIBBON WINDOW 2 3
R500.04 R500.04 COPING - ROUT AND SEAL ALL
SYSTEM - REPLACE FAILED
PERIMETER SEALANT. SEE
SYSTEM - REPLACE FAILED
PERIMETER SEALANT. SEE TYP. JOINTS IN ACCORDANCE WITH
P
R
SIXTEENTH FLOOR SIMILAR DETAIL 2/R400.01, DETAIL 4/R500.04, TYP. SIXTEENTH FLOOR
DETAIL 2/R400.01, SIM. EJ
TYP. Consultants

P U
FIFTEENTH FLOOR FIFTEENTH FLOOR
EXISTING ROOF OVERFLOW SCUPPER - 4 EXISTING METAL SPANDREL EXISTING METAL SPANDREL
SEE DETAIL 3/R500.03, TYP. R500.04
PANEL BETWEEN VERTICAL PANEL BETWEEN VERTICAL
TYP. RIBBON WINDOW SYSTEM, TYP. RIBBON WINDOW SYSTEM, TYP.
FOURTEENTH FLOOR 1 FOURTEENTH FLOOR
R400.01 TYP.
SC EXISTING METAL PANEL WITHIN
EXISTING CAST STONE COPING - ROUT 2 3 RIBBON WINDOW SYSTEM TO
AND SEAL ALL JOINTS IN ACCORDANCE R500.04 R500.04 REMAIN, TYP.
WITH DETAIL 4/R500.04, TYP. TYP.
THIRTEENTH FLOOR 1 THIRTEENTH FLOOR
EJ R500.01
F SC EXISTING CAST STONE TRIM AT TYP. EXISTING ALUMINUM FRAMED F
EXISTING CAST STONE TRIM AT
EXISTING METAL PANEL WITHIN WINDOW SURROUNDS FOR WINDOW SURROUNDS FOR RIBBON WINDOW SYSTEM -
RIBBON WINDOW SYSTEM - CLEAN, PUNCHED OPENINGS - ROUT PUNCHED OPENINGS - ROUT REPLACE FAILED PERIMETER
PRIME, AND PAINT, TYP. AND SEAL ALL JOINTS IN AND SEAL ALL JOINTS IN SEALANT IN ACCORDANCE
ACCORDANCE WITH DETAIL TWELFTH FLOOR ACCORDANCE WITH DETAIL WITH DETAIL 2/R400.01, TYP. TWELFTH FLOOR
3/R400.01, TYP. 3/400.01, TYP.
EXISTING ALUMINUM FRAMED RIBBON
WINDOW SYSTEM - REPLACE FAILED
PERIMETER SEALANT. SEE DETAIL 2/R400.01,
TYP. 1
ELEVENTH FLOOR ELEVENTH FLOOR
R500.01
2 TYP. TYP. 3
R400.01 R400.01 TYP. CLEAN, PRIME, AND PAINT
EXISTING EXPOSED STEEL
LINTELS AT WINDOW HEAD,
TYP.
TENTH FLOOR TENTH FLOOR

EXISTING LEAD-COATED
COPPER EXPANSION JOINT -
SEE DETAIL 3/R500.02, TYP.,
SIM. 1 NINTH FLOOR NINTH FLOOR
R400.01 TYP. 3 EXISTING CAST STONE
EXISTING CAST STONE WINDOW R400.01 TYP. WINDOW SILL - ROUT AND
E E
SILL - ROUT AND SEAL ALL SEAL ALL JOINTS IN
JOINTS IN ACCORDANCE WITH ACCORDANCE WITH DETAIL
DETAIL 8/R500.05, TYP., SIM. EIGHTH FLOOR 2/R400.01, TYP. EIGHTH FLOOR
TYP.
2
R400.01

SEVENTH FLOOR SEVENTH FLOOR


EXISTING MECHANICAL EXISTING MECHANICAL
SYSTEM LOUVERS TO REMAIN, SYSTEM LOUVERS TO
TYP. SIX-A FLOOR REMAIN, TYP. SIX-A FLOOR

SIXTH FLOOR SIXTH FLOOR

EXISTING CAST STONE EXISTING CAST STONE COPING,


COPING, TYP. FIFTH FLOOR TYP. FIFTH FLOOR Project

D SC SC SC SC D

REANCHOR EXISTING STEEL Grady Memorial Hospital


FRAMED WINDOW SYSTEM
FOURTH FLOOR FOURTH FLOOR
Facade Rehabilitation - Project
No. F2016008
4 4
R500.01 R500.01 80 Jesse Hill Jr. Dr., SE
TYP. TYP.
Atlanta, Georgia 30303

Client

C C
Grady Memorial Hospital
C-WING - NORTH ELEVATION SCOPE OF WORK SUMMARY:
B-WING - NORTH ELEVATION SCOPE OF WORK SUMMARY:
80 Jesse Hill Jr. Dr., SE
1 SCALE: 1/16" = 1'-0"
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2 SCALE: 1/16" = 1'-0"
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. BRICK MASONRY SEALANT REPLACEMENT - SEE DETAIL 8/R500.05
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. BRICK MASONRY SEALANT REPLACEMENT - SEE DETAIL 8/R500.05 Atlanta, Georgia 30303
4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
5. WINDOW PERIMETER SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 5. WINDOW PERIMETER SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
6. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04 6. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04
7. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 7. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52

KEY PLAN KEY PLAN


Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B B

Mark Date Description


0 1/2" 1" 2"

THIS SHEET PLOTS FULL SIZE


AT 30x42 (INCHES)

LEGEND Project No. 2016.1879


SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR Date 3/6/17
THROUGH WALL FLASHING AND BASE OF
V MISCELLANEOUS VENT
WALL REPAIRS
Drawn WL, KM
PP PIPE PENETRATION THROUGH WALL FLASHING REPAIRS

NEW BACKER ROD AND SEALANT AT CAST STONE COPING - INSPECT AND REPAIR Checked LC
EJ
BUILDING TRANSITIONS AND EXPANSION
JOINTS CAST STONE WINDOW SILLS Scale As Noted
CAST-IN-PLACE CONCRETE - INSPECT AND SUPPLEMENTAL BRICK MASONRY ANCHORS TO
REPAIR SPALLS BE INSTALLED
A RECONSTRUCT BRICK MASONRY A Original Building
Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.10
1 2 3 4 5 6 7 8 9 10

Building Elevations.dwg
Plotted: 3/20/2017 11:31 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.10 Original

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
STEEL FRAMED MECHANICAL UNIT
SCREEN - CLEAN, PRIME, AND PAINT ALL
770.923.9822 tel | 770.232.9044 fax
www.wje.com
STEEL ELEMENTS
STEEL FRAMED MECHANICAL UNIT
SCREEN - CLEAN, PRIME, AND STEEL FRAMED MECHANICAL UNIT EXISTING SHEET METAL COPING - SEAL
PAINT ALL STEEL ELEMENTS SCREEN - CLEAN, PRIME, AND JOINTS WITH PREFORMED SILICONE
PAINT ALL STEEL ELEMENTS SHEET - SEE DETAIL 1/R500.04, TYP.
ROOF LEVEL ROOF LEVEL

G
2 SIM.
TYP.
SEE 2/R100.11 FOR REPAIRS R400.01

IN
AT THIS LOCATION

1 N

D
THIRD FLOOR THIRD FLOOR
R500.01
O

D
TYP. EXISTING ALUMINUM FRAMED WINDOW

S
SYSTEM - REPLACE FAILED PERIMETER

BI
SEALANT IN ACCORDANCE WITH DETAIL
G
SECOND FLOOR
2/R400.01, TYP.
SECOND FLOOR
G

SE

R
1

O
EXISTING CAST STONE WINDOW SILL -

FO
R400.01 TYP.
ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL 8/R500.05,
TYP., SIM. P
FIRST FLOOR FIRST FLOOR
Consultants
R
ARMSTRONG STREET ENTRANCE
CANOPY
EXISTING ARCHITECTURAL METAL PANEL -
CLEAN, PRIME, AND PAINT, TYP.
P U
GROUND FLOOR GROUND FLOOR

EAST ELEVATION NORTH ELEVATION WEST ELEVATION

SCOPE OF WORK SUMMARY:


F F
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
ARMSTRONG STREET ENTRANCE ELEVATIONS 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
1 SCALE: 1/16" = 1'-0"
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
4. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
5. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
6. CAST STONE SILL REPAIRS - SEE SHEET R500.04

KEY PLAN

E E

EXISTING SHEET METAL COPING - EXISTING GALVANIZED LADDER - CLEAN, EXISTING SHEET METAL COPING - SEAL STEEL FRAMED MECHANICAL UNIT
SEAL JOINTS WITH PREFORMED PRIME, AND PAINT JOINTS WITH PREFORMED SILICONE SCREEN - CLEAN, PRIME, AND
SILICONE SHEET - SEE DETAIL SHEET - SEE DETAIL 1/R500.04, TYP. PAINT ALL STEEL ELEMENTS
1/R500.04, TYP.
EXISTING EXPANSION JOINT - SEE ROOF OVERFLOW SCUPPER - SEE DETAIL EXISTING EXPANSION JOINT - SEE DETAILS 3
DETAIL 3 THROUGH 6/R500.02, TYP. 3/R500.03, TYP. THROUGH 6/R500.02, TYP., SIM.
STEEL FRAMED MECHANICAL UNIT ROOF LEVEL ROOF LEVEL ROOF LEVEL
SCREEN - CLEAN, PRIME, AND EJ SC SC SC EJ EJ
EJ
PAINT ALL STEEL ELEMENTS 3 TYP. 3 3
R400.01 R400.01 R400.01
TYP. TYP.
LOW ROOF LEVEL LOW ROOF LEVEL LOW ROOF LEVEL

4 4
R500.01 R500.01
EXISTING ROOF TERMINATION EXISTING CAST STONE TRIM AT WINDOW EXISTING CAST STONE TRIM AT WINDOW EXISTING ROOF TERMINATION DETAIL - EXISTING CAST STONE TRIM AT WINDOW
DETAIL - NOT IN SCOPE SURROUNDS FOR PUNCHED OPENINGS - SURROUNDS FOR PUNCHED OPENINGS - TYP. NOT IN SCOPE TYP. SURROUNDS FOR PUNCHED OPENINGS -
WEST ELEVATION ROUT AND SEAL ALL JOINTS IN ROUT AND SEAL ALL JOINTS IN NORTH ELEVATION EAST ELEVATION ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL 3/R400.01, ACCORDANCE WITH DETAIL 3/R400.01, ACCORDANCE WITH DETAIL 3/R400.01,
Project
TYP. TYP. TYP.
D D
Grady Memorial Hospital
Facade Rehabilitation - Project
LOW ROOF - ELEVATIONS
2 SCALE: 1/16" = 1'-0" SCOPE OF WORK SUMMARY: No. F2016008
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 80 Jesse Hill Jr. Dr., SE
3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
4. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
5. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
Atlanta, Georgia 30303
6. CAST STONE SILL REPAIR - SEE SHEET R500.04

KEY PLAN

Client

C EXISTING CAST STONE C

EXISTING CAST STONE


COPING - ROUT AND SEAL ALL
JOINTS IN ACCORDANCE WITH
4
R500.04
PENTHOUSE ROOF
Grady Memorial Hospital
COPING - ROUT AND SEAL ALL
JOINTS IN ACCORDANCE WITH TYP.
DETAIL 4/R500.04 TYP. 80 Jesse Hill Jr. Dr., SE
DETAIL 4/R500.04 4 TWENTIETH FLOOR
R500.04 EXISTING CAST STONE
COPING - ROUT AND SEAL ALL
4 EXTENT OF GALVANIZED Atlanta, Georgia 30303
ROOF LEVEL R500.04
3 JOINTS IN ACCORDANCE WITH STEEL STAIR STRUCTURE
EXISTING GALVANIZED TYP.
R400.01 DETAIL 4/R500.04 3
LADDER - CLEAN, PRIME, TYP. NINETEENTH FLOOR
R400.01
AND PAINT SIM. TYP.
SIM.
CLEAN, PRIME, AND PAINT
CLEAN, PRIME, AND PAINT EIGHTEENTH FLOOR
STEEL DOORS, TYP. 4
STEEL DOORS, TYP.
R500.01
4 TYP.
R500.01 CLEAN, PRIME, AND PAINT EIGHTEENTH FLOOR
4
TYP. STEEL DOORS, TYP. R500.01 TYP.

A AND B WING - MECH. PENTHOUSE EAST ELEVATION C AND D WING MECH. PENTHOUSE - WEST ELEVATION E WING MECH PENTHOUSE - EAST ELEVATION
3 SCALE: 1/16" = 1'-0" 4 SCALE: 1/16" = 1'-0" 5 SCALE: 1/16" = 1'-0"
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B B

Mark Date Description


EXISTING CAST STONE 0 1/2" 1" 2"

COPING - ROUT AND SEAL ALL PENTHOUSE ROOF


JOINTS IN ACCORDANCE WITH 4
THIS SHEET PLOTS FULL SIZE
R500.04 LEGEND
DETAIL 4/R500.04 AT 30x42 (INCHES)
TYP.
SC ROOF OVERFLOW SCUPPER REMOVE AND REPLACE BRICK MASONRY FOR
TWENTIETH FLOOR THROUGH WALL FLASHING AND BASE OF Project No. 2016.1879
PP PP V MISCELLANEOUS VENT
WALL REPAIRS
THROUGH WALL FLASHING REPAIRS Date 3/6/17
PP PP PIPE PENETRATION
NINETEENTH FLOOR
NEW BACKER ROD AND SEALANT AT CAST STONE COPING - INSPECT AND REPAIR Drawn WL, KM
PP SCOPE OF WORK SUMMARY: EJ
TYP. BUILDING TRANSITIONS AND EXPANSION
CLEAN, PRIME, AND PAINT PP 1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01 CAST STONE WINDOW SILLS
JOINTS
STEEL DOORS, TYP. 4 2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01 Checked LC
R500.01 3. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 CAST-IN-PLACE CONCRETE - INSPECT AND SUPPLEMENTAL BRICK MASONRY ANCHORS TO
4. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 REPAIR SPALLS BE INSTALLED
EIGHTEENTH FLOOR Scale As Noted
5. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 RECONSTRUCT BRICK MASONRY
6. CAST STONE SILL AND COPING REPAIRS - SEE SHEET R500.04

A A Original Building
Elevations
E WING MECH. PENTHOUSE - WEST ELEVATION
6 SCALE: 1/16" = 1'-0" Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R100.11
1 2 3 4 5 6 7 8 9 10

Building Elevation.dwg
Plotted: 3/20/2017 11:31 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R100.11 Original

ENGINEERS
ORIGINAL BUILDING - C WING
ORIGINAL BUILDING - B WING ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
EXISTING MECHANICAL SYSTEM EXISTING CAST STONE COPING - ROUT 2915 Premiere Parkway, Suite 100
EXHAUST DUCT WORK TO REMAIN AND SEAL ALL JOINTS IN ACCORDANCE Duluth, Georgia 30097
WITH DETAIL 4/R500.04, TYP.
EIGHTEENTH FLOOR EIGHTEENTH FLOOR 770.923.9822 tel | 770.232.9044 fax
EXISTING CAST STONE COPING -
www.wje.com
ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL
4/R500.04, TYP.
4 4
R500.04 R500.04
TYP. SEVENTEENTH FLOOR TYP. SEVENTEENTH FLOOR

G
L

IN
SIXTEENTH FLOOR SIXTEENTH FLOOR
N

D
RECONSTRUCT EXISTING
O

D
BRICK MASONRY. SEE DETAIL
6/R500.03, TYP.
S

BI
FIFTEENTH FLOOR FIFTEENTH FLOOR
G
EXISTING CAST STONE WINDOW SILL - EXISTING CAST STONE WINDOW SILL - SUPPLEMENTAL BRICK
G

SE

R
ROUT AND SEAL ALL JOINTS IN ROUT AND SEAL ALL JOINTS IN MASONRY ANCHORS TO BE
ACCORDANCE WITH DETAIL 8/R500.05, ACCORDANCE WITH DETAIL 8/R500.05, INSTALLED, TYP. - SEE DETAIL

FO
TYP., SIM. FOURTEENTH FLOOR TYP., SIM. 2/R500.03 FOURTEENTH FLOOR

EXISTING CAST STONE TRIM AT


3
R400.01 TYP. EXISTING CAST STONE TRIM AT
3
R400.01 TYP.
P
WINDOW SURROUNDS FOR PUNCHED
OPENINGS - ROUT AND SEAL ALL
WINDOW SURROUNDS FOR PUNCHED
OPENINGS - ROUT AND SEAL ALL Consultants
R
JOINTS IN ACCORDANCE WITH DETAIL
8/R500.05, TYP., SIM.
THIRTEENTH FLOOR JOINTS IN ACCORDANCE WITH DETAIL
8/R500.05, TYP., SIM.
THIRTEENTH FLOOR

P U
TWELFTH FLOOR TWELFTH FLOOR
1 1
EXISTING METAL PANEL WITHIN
R400.01 TYP. R400.01 TYP.
RIBBON WINDOW SYSTEM TO
REMAIN, TYP.
ELEVENTH FLOOR ELEVENTH FLOOR

EXISTING METAL PANEL WITHIN


F RIBBON WINDOW SYSTEM TO F
REMAIN, TYP.

TENTH FLOOR TENTH FLOOR


EXISTING ALUMINUM FRAMED RIBBON EXISTING ALUMINUM FRAMED RIBBON
WINDOW SYSTEM - REPLACE WINDOW SYSTEM - REPLACE
PERIMETER SEALANT IN PERIMETER SEALANT IN
ACCORDANCE WITH DETAIL 2/R400.01, ACCORDANCE WITH DETAIL 2/R400.01,
NINTH FLOOR NINTH FLOOR
TYP. 2 SIM. TYP.
R400.01 TYP.

EIGHTH FLOOR EIGHTH FLOOR

EXISTING MECHANICAL SYSTEM


LOUVERS TO REMAIN, TYP. SEVENTH FLOOR SEVENTH FLOOR

EXISTING MECHANICAL SYSTEM


SIX-A FLOOR LOUVERS TO REMAIN, TYP. SIX-A FLOOR
E E
CLEAN, PRIME, AND PAINT
CLEAN, PRIME, AND PAINT EXISTING EXPOSED STEEL ELEMENTS,
STEEL ELEMENTS, TYP. TYP.
SIXTH FLOOR SIXTH FLOOR

EXISTING CAST STONE COPING -


ROUT AND SEAL ALL JOINTS IN
ACCORDANCE WITH DETAIL 4/R500.04,
TYP. FIFTH FLOOR FIFTH FLOOR
TYP. PP
SC
4
R500.01

FOURTH FLOOR EJ EJ FOURTH FLOOR


2
PP (x6) R400.01 TYP.
EXISTING MECHANICAL
SYSTEM DUCT WORK TO
REMAIN, TYP.
THIRD FLOOR THIRD FLOOR
EXISTING PAINTED GLAZING
TO BE REPAINTED
PP Project
EXISTING PLUMBING TO REMAIN
D D

SECOND FLOOR SECOND FLOOR Grady Memorial Hospital


CLEAN, PRIME, AND PAINT Facade Rehabilitation - Project
EXISTING STEEL ELEMENTS, TYP.
No. F2016008
FIRST FLOOR FIRST FLOOR 80 Jesse Hill Jr. Dr., SE
4 Atlanta, Georgia 30303
R500.01
TYP.
GROUND FLOOR GROUND FLOOR

BASEMENT LEVEL BASEMENT LEVEL


Client
KEY PLAN KEY PLAN
C C
B-WING EAST ELEVATION Grady Memorial Hospital
C WING - WEST ELEVATION SCOPE OF WORK SUMMARY: B WING - EAST ELEVATION SCOPE OF WORK SUMMARY:
80 Jesse Hill Jr. Dr., SE
1 SCALE: 1/16" = 1'-0"
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01 2 SCALE: 1/16" = 1'-0"
1. SHELF ANGLE FLASHING REPAIR - SEE DETAILS 1 THROUGH 3/R500.01
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. BRICK MASONRY SUPPLEMENTAL ANCHORAGE REPAIRS - SEE DETAILS 2 THROUGH 5/R500.03
2. BASE OF WALL FLASHING REPAIR - SEE DETAIL 4/R500.01
3. BRICK MASONRY SUPPLEMENTAL ANCHORAGE REPAIRS - SEE DETAILS 2 THROUGH 5/R500.03
Atlanta, Georgia 30303
4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13 4. MISCELLANEOUS STEEL PAINTING - SEE SPECIFICATION SECTION 09 97 13
5. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06 5. SEALANT REPLACEMENT - SEE DETAILS 1 AND 2/R500.06
6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 6. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52

EXISTING LEAD-COATED COPPER


EXPANSION JOINT - SEE DETAIL
EXISTING SHEET METAL COPING - SEAL 3/R500.02, TYP., SIM. EXISTING SHEET METAL COPING - SEAL EXISTING SHEET METAL COPING - SEAL EXISTING SHEET METAL COPING - SEAL
JOINTS WITH PREFORMED SILICONE JOINTS WITH PREFORMED SILICONE JOINTS WITH PREFORMED SILICONE JOINTS WITH PREFORMED SILICONE
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

SHEET - SEE DETAIL 1/R500.04, TYP. FOURTH FLOOR SHEET - SEE DETAIL 1/R500.04, TYP. FOURTH FLOOR SHEET - SEE DETAIL 1/R500.04, TYP. FOURTH FLOOR SHEET - SEE DETAIL 1/R500.04, TYP. FOURTH FLOOR
EJ EJ EJ
B SIM. 3 3 SIM. 2 SIM. 3 SIM. B
TYP. R400.01 R400.01 TYP. R400.01 TYP. R400.01 TYP.
CLEAN, PRIME, AND PAINT EXISTING
Mark Date Description
EXPOSED STEEL LINTELS AT WINDOW
CLEAN, PRIME, AND PAINT EXISTING CLEAN, PRIME, AND PAINT EXISTING HEAD, TYP. CLEAN, PRIME, AND PAINT EXISTING 0 1/2" 1" 2"
EXPOSED STEEL LINTELS AT WINDOW THIRD FLOOR EXPOSED STEEL LINTELS AT WINDOW PP THIRD FLOOR THIRD FLOOR EXPOSED STEEL LINTELS AT WINDOW THIRD FLOOR
2 TYP.
HEAD, TYP. V V HEAD, TYP. R400.01 HEAD, TYP. 4 THIS SHEET PLOTS FULL SIZE
EXISTING ALUMINUM FRAMED RIBBON EXISTING STEEL LADDER - CLEAN, PRIME, PP PP R500.01 AT 30x42 (INCHES)

PP EXISTING THROUGH-WALL SCUPPER - WINDOW SYSTEM - REPLACE PERIMETER AND PAINT ALL EXPOSED STEEL TYP.
SEE DETAIL 4/R500.04, TYP. SEALANT IN ACCORDANCE WITH DETAIL ELEMENTS, TYP.
PP SECOND FLOOR EJ SECOND FLOOR 2/R400.01, TYP. SECOND FLOOR SECOND FLOOR Project No. 2016.1879
SC EXISTING CAST STONE COPING - ROUT
SIM. 2 TYP. 2
TYP. R400.01 AND SEAL ALL JOINTS IN ACCORDANCE SIM. R400.01 Date 3/6/17
PP PP
EXISTING CAST STONE COPING - ROUT WITH DETAIL 4/R500.04, TYP.
4
R500.01 AND SEAL ALL JOINTS IN ACCORDANCE EXISTING PLYWOOD PANEL - REPLACE Drawn WL, KM
TYP. WITH DETAIL 4/R500.04, TYP. GLAZING WITH NEW SPANDREL PANELS
FIRST FLOOR FIRST FLOOR FIRST FLOOR FIRST FLOOR
Checked LC
4 4 4
R500.01 R500.01 R500.01 Scale As Noted
TYP. TYP. TYP.

A
C WING LIGHT WELL - SOUTH ELEVATION C WING LIGHT WELL EAST ELEVATION B WING LIGHT WELL - SOUTH ELEVATION B WING LIGHT WELL - WEST ELEVATION
A Original Building
3 4 5 6
SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0" SCALE: 1/16" = 1'-0"
Elevations
Sheet Title

1 2
KEY PLAN

3 4 5
KEY PLAN

6 7
KEY PLAN

8 9
KEY PLAN

10
Sheet No. R100.12
1 2 3 4 5 6 7 8 9 10

Addition Elevations.dwg
Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R200.01 West

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

G
L

IN
WESTERN ADDITION - B WING WESTERN ADDITION - A WING

D
O

D
S

BI
G G

SE

R
O

FO
P
Consultants
R
P U
ROOF LEVEL

ARCHITECTURAL METAL
LOUVERS, TYP.
15TH FLOOR

F 4 5 F
R400.01 R400.01 14TH FLOOR
TYP.

EXISTING THIN STONE


VENEER CLADDING SYSTEM, 13TH FLOOR
TYP.

12TH FLOOR

EXISTING PRECAST WALL


PANEL, TYP.
11TH FLOOR

ARCHITECTURAL METAL
SPANDREL, TYP. 10TH FLOOR
E E

9TH FLOOR
ALUMINUM WINDOW SYSTEM,
TYP. INSPECT PERIMETER
SEALANT AND REPLACE AS
NECESSARY IN ACCORDANCE
WITH DETAILS 4 AND 5/R400.01, 8TH FLOOR
TYP.

7TH FLOOR
EXISTING SILICONE SEALANT AT
HORIZONTAL AND VERTICAL
STONE-TO-STONE JOINTS.
INSPECT SEALANT AND 6A FLOOR
REPLACE AS NECESSARY,TYP.

Project

D 6TH FLOOR D
Grady Memorial Hospital
Facade Rehabilitation - Project
5TH FLOOR
No. F2016008
80 Jesse Hill Jr. Dr., SE
4TH FLOOR Atlanta, Georgia 30303

3RD FLOOR

Client
2ND FLOOR
STEEL COLUMN SHAFT AND
C CAPITAL, TYP. C
Grady Memorial Hospital
80 Jesse Hill Jr. Dr., SE
1ST FLOOR

EXISTING THIN STONE PANEL


Atlanta, Georgia 30303
CLAD COLUMN BASE AND
PEDESTAL, TYP.

GROUND FLOOR
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B SCOPE OF WORK SUMMARY: B


LEGEND
WEST ELEVATION 1. STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05
1 SCALE: 1/16" = 1'-0" 2. STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05 METAL SPANDREL PANELS AND BUILDING Mark Date Description
3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06 COMPONENTS 0 1/2" 1" 2"
4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
THIS SHEET PLOTS FULL SIZE
AT 30x42 (INCHES)

KEY PLAN Project No. 2016.1879

Date 3/6/17

Drawn WL, KM

Checked LC

Scale As Noted

A A
West Addition Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R200.01
1 2 3 4 5 6 7 8 9 10

Addition Elevations.dwg
Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R200.02 West
WESTERN ADDITION - B WING
ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

16TH FLOOR
H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
15TH FLOOR Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

14TH FLOOR

G
5 13TH FLOOR
R400.01 1182.33
L

IN
TYP.

D
O

D
12TH FLOOR

BI
G
EXISTING PRECAST WALL
G

SE

R
PANEL, TYP. 11TH FLOOR
WESTERN ADDITION - B WING WESTERN ADDITION - A WING

FO
P
ARCHITECTURAL METAL
10TH FLOOR Consultants
R
ROOF LEVEL ROOF LEVEL
SPANDREL, TYP.

P U
ARCHITECTURAL METAL 9TH FLOOR
LOUVERS, TYP. ALUMINUM WINDOW SYSTEM,
15TH FLOOR 15TH FLOOR TYP. INSPECT PERIMETER
ARCHITECTURAL METAL
SEALANT AND REPLACE AS
LOUVERS, TYP.
NECESSARY IN ACCORDANCE
8TH FLOOR
WITH DETAILS 4 AND 5/R400.01,
TYP.
14TH FLOOR 14TH FLOOR

F 7TH FLOOR F

EXISTING SILICONE SEALANT AT


EXISTING THIN STONE HORIZONTAL AND VERTICAL
VENEER CLADDING SYSTEM, 13TH FLOOR 13TH FLOOR 6A FLOOR
PRECAST PANEL JOINTS.
TYP. INSPECT SEALANT AND
EXISTING THIN STONE
VENEER CLADDING SYSTEM, REPLACE AS NECESSARY, TYP.
TYP.
12TH FLOOR 12TH FLOOR 6TH FLOOR

11TH FLOOR 11TH FLOOR 5TH FLOOR

10TH FLOOR 10TH FLOOR LIGHT WELL - NORTH ELEVATION


3 SCALE: 1/16" = 1'-0"

E E
SCOPE OF WORK SUMMARY:
9TH FLOOR 9TH FLOOR
ALUMINUM WINDOW SYSTEM, 1. STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05
TYP. INSPECT PERIMETER 2. STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05
SEALANT AND REPLACE AS 3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06
NECESSARY IN ACCORDANCE ALUMINUM WINDOW SYSTEM,
TYP. INSPECT PERIMETER 4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
WITH DETAILS 1 AND 2/R500.06,
8TH FLOOR SEALANT AND REPLACE AS 8TH FLOOR
TYP.
NECESSARY IN ACCORDANCE
WITH DETAILS 1 AND 2/R500.06,
TYP.

7TH FLOOR 7TH FLOOR KEY PLAN


EXISTING SILICONE SEALANT AT
WESTERN ADDITION - B WING
HORIZONTAL AND VERTICAL
STONE-TO-STONE JOINTS.
INSPECT SEALANT AND 6A FLOOR EXISTING SILICONE SEALANT AT 6A FLOOR
REPLACE AS NECESSARY, TYP. HORIZONTAL AND VERTICAL
STONE-TO-STONE JOINTS.
INSPECT SEALANT AND
REPLACE AS NECESSARY, TYP. PARAPET
6TH FLOOR 6TH FLOOR 16TH FLOOR
Project

D D
Grady Memorial Hospital
5TH FLOOR 5TH FLOOR 15TH FLOOR
Facade Rehabilitation - Project
No. F2016008
4TH FLOOR 4TH FLOOR
5
R400.01
TYP.
14TH FLOOR 80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
3RD FLOOR 3RD FLOOR EXISTING PRECAST WALL 13TH FLOOR
PANEL, TYP.

STEEL COLUMN SHAFT AND


ARCHITECTURAL PANEL, TYP. 12TH FLOOR
2ND FLOOR 2ND FLOOR ARCHITECTURAL METAL
SPANDREL, TYP.
Client
STEEL COLUMN SHAFT AND
EXISTING THIN STONE PANEL ARCHITECTURAL PANEL, TYP.
C C
CLAD COLUMN BASE AND
PEDESTAL, TYP. 1ST FLOOR 1ST FLOOR
11TH FLOOR Grady Memorial Hospital
ALUMINUM WINDOW SYSTEM, 80 Jesse Hill Jr. Dr., SE
TYP. INSPECT PERIMETER
CONCRETE COLUMNS EXISTING THIN STONE PANEL SEALANT AND REPLACE AS
NECESSARY IN ACCORDANCE
Atlanta, Georgia 30303
CLAD COLUMN BASE AND 10TH FLOOR
GROUND FLOOR PEDESTAL, TYP. GROUND FLOOR WITH DETAILS 4 AND 5/R400.01,
TYP.

CONCRETE COLUMNS 9TH FLOOR

EXISTING SILICONE SEALANT AT


HORIZONTAL AND VERTICAL
NORTH ELEVATION SOUTH ELEVATION PRECAST PANEL JOINTS.
1 SCALE: 1/16" = 1'-0" 2 SCALE: 1/16" = 1'-0" INSPECT SEALANT AND 8TH FLOOR
REPLACE AS NECESSARY, TYP.
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without

SCOPE OF WORK SUMMARY: SCOPE OF WORK SUMMARY:


permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

7TH FLOOR
B 1. STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05 1. STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05 B
2. STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05 2. STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05
3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06 3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06 6A FLOOR Mark Date Description
4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
0 1/2" 1" 2"

THIS SHEET PLOTS FULL SIZE


KEY PLAN KEY PLAN AT 30x42 (INCHES)
6TH FLOOR

Project No. 2016.1879

Date 3/6/17
5TH FLOOR

Drawn WL, KM

Checked LC
LIGHT WELL - SOUTH ELEVATION
4 SCALE: 1/16" = 1'-0" Scale As Noted

SCOPE OF WORK SUMMARY:


A A
1.
2.
STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05
STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05
West Addition Elevations
3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06
4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
Sheet Title

KEY PLAN

1 2 3 4 5 6 7 8 9 10
Sheet No. R200.02
1 2 3 4 5 6 7 8 9 10

Addition Elevations.dwg
Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R200.03 West

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

G
L

IN
WESTERN ADDITION - A WING WESTERN ADDITION - B WING
N

D
O

D
S

BI
G G

SE

R
O

FO
P
Consultants
R
P U
ROOF LEVEL

ARCHITECTURAL METAL
LOUVERS, TYP.

3'-6"
15TH FLOOR

F F
14TH FLOOR

EXISTING THIN STONE


VENEER CLADDING SYSTEM, 13TH FLOOR
TYP.

12TH FLOOR

EXISTING PRECAST WALL


PANEL, TYP.
11TH FLOOR

ARCHITECTURAL METAL
SPANDREL, TYP. 5
E 10TH FLOOR E
R400.01 SIM.
TYP.

9TH FLOOR
ALUMINUM WINDOW SYSTEM,
TYP. INSPECT PERIMETER
SEALANT AND REPLACE AS
NECESSARY IN ACCORDANCE
WITH DETAILS 4 AND 5/R400.01,
TYP. 8TH FLOOR

EXISTING SILICONE SEALANT AT 7TH FLOOR


HORIZONTAL AND VERTICAL
STONE-TO-STONE JOINTS.
INSPECT SEALANT AND 6A FLOOR
REPLACE AS NECESSARY, TYP.
Project

D D
6TH FLOOR
Grady Memorial Hospital
Facade Rehabilitation - Project
5TH FLOOR No. F2016008
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
4TH FLOOR

3RD FLOOR

Client
2ND FLOOR
C C
Grady Memorial Hospital
80 Jesse Hill Jr. Dr., SE
1ST FLOOR Atlanta, Georgia 30303

GROUND FLOOR

EAST ELEVATION
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without

SCOPE OF WORK SUMMARY:


permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

1 SCALE: 1/16" = 1'-0"


B 1. STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05 B
2. STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05
3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06 Mark Date Description
4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
0 1/2" 1" 2"

THIS SHEET PLOTS FULL SIZE


AT 30x42 (INCHES)

KEY PLAN
Project No. 2016.1879

Date 3/6/17

Drawn WL, KM

Checked LC

Scale As Noted

A A
West Addition Elevations
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R200.03
1 2 3 4 5 6 7 8 9 10

Addition Elevations.dwg
Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R300.01 South

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H K-WING ENTRANCE J-WING H-WING H


Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
PENTHOUSE 770.923.9822 tel | 770.232.9044 fax
LEVEL www.wje.com
ARCHITECTURAL METAL
LOUVERS, TYP.
MECHANICAL SCREEN WALL

ROOF LEVEL

G
L
EXISTING ALUMINUM WINDOW

IN
SYSTEM. INSPECT PERIMETER
SEALANT AND REPLACE AS
NECESSARY, TYP.
N

D
7TH FLOOR
O

D
S

BI
E
6A FLOOR
G G

R
O

FO
ARCHITECTURAL METAL
SPANDREL, TYP. 6TH FLOOR
P
Consultants
R
EXISTING TRAVERTINE
PANELS, TYP.
5TH FLOOR
P U
4TH FLOOR

EXISTING SILICONE SEALANT AT


HORIZONTAL AND VERTICAL
STONE-TO-STONE JOINTS.
INSPECT SEALANT AND
REPLACE AS NECESSARY, TYP. 3RD FLOOR

F F

2ND FLOOR
6
R400.01
TYP.
CLEAN METAL ENTRANCE
CANOPIES
EXISTING METAL FENCING
1ST FLOOR
NOT IN SCOPE OF WORK

GROUND FLOOR

TRAVERTINE CLAD
ENTRANCE COLUMNS, KEY PLAN
TYP.

E E

LEGEND
EAST ELEVATION SCOPE OF WORK SUMMARY:
1 SCALE: 1/16" = 1'-0"
1. STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05
ARCHITECTURAL METAL SPANDREL PANEL
2. STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05
BASE OF WALL SEALANT REPAIR. SEE
3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06
DETAIL 7/R500.05.
4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
5. STONE CLADDING BASE OF WALL REPAIRS - SEE DETAIL 7/R500.05

H-WING J-WING K-WING ENTRANCE

Project

D D
PENTHOUSE
MECHANICAL SCREEN WALL
LEVEL Grady Memorial Hospital
Facade Rehabilitation - Project
ARCHITECTURAL METAL
LOUVERS, TYP. No. F2016008
80 Jesse Hill Jr. Dr., SE
ROOF LEVEL
Atlanta, Georgia 30303
EXISTING ALUMINUM WINDOW
SYSTEM. INSPECT PERIMETER
SEALANT AND REPLACE AS
NECESSARY, TYP. 7TH FLOOR

6A FLOOR

Client

C 6TH FLOOR C

ARCHITECTURAL METAL
Grady Memorial Hospital
SPANDREL, TYP. 80 Jesse Hill Jr. Dr., SE
5TH FLOOR Atlanta, Georgia 30303
EXISTING TRAVERTINE
PANELS, TYP.

4TH FLOOR

EXISTING SILICONE SEALANT AT


HORIZONTAL AND VERTICAL
STONE-TO-STONE JOINTS. 3RD FLOOR
INSPECT SEALANT AND REPLACE
AS NECESSARY, TYP.
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

2ND FLOOR
6
B R400.01 B
TYP.
Mark Date Description
0 1/2" 1" 2"
1ST FLOOR
THIS SHEET PLOTS FULL SIZE
AT 30x42 (INCHES)

EXISTING METAL FENCING


NOT IN SCOPE OF WORK
Project No. 2016.1879
GROUND FLOOR
Date 3/6/17
EXISTING DECK
CURVED METAL PANEL CLAD Drawn WL, KM
ENTRANCE
Checked LC
KEY PLAN

Scale As Noted

A SCOPE OF WORK SUMMARY: A

WEST ELEVATION 1. STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05
LEGEND
South Addition Elevations
2 SCALE: 1/16" = 1'-0" 2. STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05 ARCHITECTURAL METAL SPANDREL PANEL
3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06
4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 BASE OF WALL SEALANT REPAIR. SEE
5. STONE CLADDING BASE OF WALL REPAIRS - SEE DETAIL 7/R500.05 DETAIL 7/R500.05. Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R300.01
1 2 3 4 5 6 7 8 9 10

Addition Elevations.dwg
Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R300.02 South

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
J-WING K-WING L-WING Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

PENTHOUSE
LEVEL
MECHANICAL SCREEN WALL
ARCHITECTURAL METAL

G
LOUVERS, TYP.

IN
ROOF LEVEL
N

D
O

D
S

BI
G
7TH FLOOR
G

SE

R
EXISTING TRAVERTINE
O

FO
PANELS, TYP. 6A FLOOR

P
Consultants
R
ARCHITECTURAL METAL
SPANDREL, TYP. 6TH FLOOR

P U
5TH FLOOR

EXISTING ALUMINUM WINDOW


SYSTEM. INSPECT PERIMETER
SEALANT AND REPLACE AS 4TH FLOOR
NECESSARY, TYP.

F F

3RD FLOOR

EXISTING SILICONE SEALANT AT 2ND FLOOR


HORIZONTAL AND VERTICAL 6
STONE-TO-STONE JOINTS. R400.01 CLEAN METAL ENTRANCE
INSPECT SEALANT AND TYP.
CANOPIES
REPLACE AS NECESSARY, TYP.

1ST FLOOR

GROUND FLOOR

EXISTING DECK
E E

LEGEND
SCOPE OF WORK SUMMARY:
SOUTH ELEVATION
1 SCALE: 1/16" = 1'-0"
1. STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05
ARCHITECTURAL METAL SPANDREL PANEL
2. STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05
BASE OF WALL SEALANT REPAIR. SEE
3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06
DETAIL 7/R500.05.
4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52
5. STONE CLADDING BASE OF WALL REPAIRS - SEE DETAIL 7/R500.05

KEY PLAN

Project
L-WING K-WING J-WING
D D
Grady Memorial Hospital
MECHANICAL SCREEN WALL
PENTHOUSE
Facade Rehabilitation - Project
ARCHITECTURAL METAL LEVEL No. F2016008
LOUVERS, TYP.
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
ROOF LEVEL

EXISTING SILICONE SEALANT AT


HORIZONTAL AND VERTICAL
STONE-TO-STONE JOINTS.
INSPECT SEALANT AND 7TH FLOOR
REPLACE AS NECESSARY, TYP.
Client
6A FLOOR
C C
Grady Memorial Hospital
ARCHITECTURAL METAL
SPANDREL, TYP. 6TH FLOOR
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303

5TH FLOOR

EXISTING ALUMINUM WINDOW


SYSTEM. INSPECT PERIMETER H-WING INTERIOR NOT IN
SEALANT AND REPLACE AS SCOPE OF WORK
NECESSARY, TYP. 4TH FLOOR

EXISTING TRAVERTINE 3RD FLOOR


PANELS, TYP.
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B B

2ND FLOOR Mark Date Description


CLEAN METAL 6
ENTRANCE CANOPIES R400.01 0 1/2" 1" 2"
TYP.
THIS SHEET PLOTS FULL SIZE
AT 30x42 (INCHES)

1ST FLOOR
Project No. 2016.1879

Date 3/6/17
GROUND FLOOR Drawn WL, KM

Checked LC

Scale As Noted
SCOPE OF WORK SUMMARY: LEGEND

A NORTH ELEVATION 1. STONE CLADDING CRACK AND SPALL REPAIR - SEE DETAILS 1 THROUGH 3R/500.05 ARCHITECTURAL METAL SPANDREL PANEL A
2 SCALE: 1/16" = 1'-0" 2. STONE CLADDING BUG HOLE REPAIR - SEE DETAIL 6/R500.05
South Addition Elevations
3. SEALANT REPLACEMENT - SEE DETAILS 4 AND 5/R500.05 AND DETAILS 1 AND 2/R500.06 BASE OF WALL SEALANT REPAIR. SEE
4. FACADE CLEANING - SEE SPECIFICATION SECTION 04 01 20.52 DETAIL 7/R500.05.
5. STONE CLADDING BASE OF WALL REPAIRS - SEE DETAIL 7/R500.05

Sheet Title

KEY PLAN

1 2 3 4 5 6 7 8 9 10
Sheet No. R300.02
1 2 3 4 5 6 7 8 9 10

Elevations.dwg
Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R400.01 Enlarged

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS
REMOVE AND REPLACE PERIMETER
SEALANT, TYP. TYP. TYP.
REMOVE AND REPLACE PERIMETER
H SEALANT, TYP. H
ALTERNATE NO. 1 - INSPECT ALL EXTENT OF NEW Wiss, Janney, Elstner Associates, Inc.
EXISTING PERIMETER SEALANT - THROUGH-WALL FLASHING
2 SIM.
REPAIRS 2 1 2915 Premiere Parkway, Suite 100
REPLACE FAILED SEALANT IN ALTERNATE NO. 1 - INSPECT ALL
ACCORDANCE WITH DETAILS 1
R500.01
EXISTING PERIMETER SEALANT - R500.01 TYP. R500.01
TYP.
APPROXIMATE EXTENT OF Duluth, Georgia 30097
AND 2/R500.06 REPLACE FAILED SEALANT IN BRICK REMOVAL FOR NEW 770.923.9822 tel | 770.232.9044 fax
REMOVE EXISTING BRICK MASONRY 3
ACCORDANCE WITH DETAILS 1 THROUGH-WALL FLASHING R500.01 www.wje.com
AS NECESSARY TO REMOVE CAST TYP.
AND 2/R500.06 REPAIRS
STONE
EXISTING ARCHITECTURAL
METAL SPANDREL PANEL.
EXISTING ALUMINUM FRAMED REMOVE EXISTING CAST STONE REMOVE AND REPLACE PERIMETER
RIBBON WINDOW SYSTEM HEAD TO INSTALL NEW SEALANT, TYP.
INSPECT AND REPLACE FAILED
THROUGH-WALL FLASHING
GLAZING SEALANT, TYP. INSTALL NEW PRE-FORMED
SILICONE SHEET AT ALL GANGED ALTERNATE NO. 1 - INSPECT ALL

O G
MULLION JOINTS, TYP. INSPECT ALL EXISTING GLAZING EXISTING PERIMETER SEALANT -

LY
EXISTING ALUMINUM FRAMED TYP. REPLACE FAILED SEALANT IN

TYP.
9 SEALANT - REPLACE ALL FAILED

S IN
RIBBON WINDOW SYSTEM

TYP.
INSPECT AND REPLACE FAILED R400.01 SEALANT, TYP. ACCORDANCE WITH DETAILS 1
GLAZING SEALANT, TYP. AND 2/R500.06

N
SE DD
ROUT AND SEAL EXISTING JOINTS
IN CAST STONE WINDOW SILLS IN ROUT AND SEAL EXISTING JOINTS ROUT AND SEAL EXISTING JOINTS 7
ACCORDANCE WITH DETAIL IN CAST STONE WINDOW SILLS IN IN CAST STONE WINDOW TRIM IN R500.04 TYPICAL CRACK IN CAST

I
8/R500.05, TYP., SIM. ACCORDANCE WITH DETAIL 7 ACCORDANCE WITH DETAIL TYP. STONE SILL - ROUT AND SEAL

PO B
7 8/R500.05, TYP., SIM. R500.04 8/R500.05, TYP., SIM. IN ACCORDANCE WITH DETAIL
G G
R500.04
TYP. 8/R500.05, TYP.

R R
COAT EXISTING CAST STONE TYP. COAT EXISTING CAST STONE
SIM. CR EXISTING BRICK VENEER TO
SILL WITH NEW ACRYLIC SILL WITH NEW ACRYLIC

PU FO
COATING, TYP. COATING, TYP. REMAIN, TYP.
CR LIMITS OF TYPICAL SPALL AT TYP.
CR CAST STONE SILL. SEE 6
TYPICAL CRACK IN CAST
R500.01
STONE SILL - ROUT AND SEAL TYPICAL CRACK IN CAST DETAIL 7/R500.04, TYP.
IN ACCORDANCE WITH DETAIL STONE SILL - ROUT AND SEAL 5 Consultants
EXISTING BRICK VENEER, 5
4/R500.06, TYP. IN ACCORDANCE WITH DETAIL R500.01 EXISTING BRICK VENEER,
R500.01
TYP. SIM. 4/R500.06 TYP. TYP.
LIMITS OF TYPICAL SPALL AT
CAST STONE SILL

LIMITS OF TYPICAL SPALL AT


CAST STONE SILL

SPANDREL PANEL - ENLARGED ELEVATION RIBBON WINDOW - ENLARGED ELEVATION PUNCHED OPENING - ENLARGED ELEVATION
1 SCALE: 1/2" = 1'-0" 2 SCALE: 1/2" = 1'-0" 3 SCALE: 1/2" = 1'-0"

F F

TYP.

TYP.
TYP. TYPICAL EXISTING
STONE-TO-STONE SEALANT JOINT -
TO BE REMOVED AND REPLACED,
TYP.
EXISTING PRECAST 7 7
CONCRETE WALL PANEL R400.01 INSPECT ALL EXISTING R400.01
TYP. PERIMETER SEALANT - REPLACE EXISTING PRECAST
TYP.
SIM. FAILED SEALANT IN ACCORDANCE CONCRETE WALL PANEL
WITH DETAILS 1 AND 2/R500.06 ALTERNATE NO. 2 - INSPECT ALL
EXISTING SEALANT - REPLACE
EXISTING METAL SPANDREL
FAILED SEALANT IN ACCORDANCE
PANEL, TYP. WET SEAL EXISTING ALUMINUM INSPECT ALL EXISTING
E WITH DETAILS 1 AND 2/R500.06 E
RIBBON WINDOW ASSEMBLY, PERIMETER SEALANT - REPLACE
TYP. FAILED SEALANT IN ACCORDANCE
WITH DETAILS 1 AND 2 R/500.06

TYP.
TYP. EXISTING ALUMINUM FRAMED
9
WINDOW SYSTEM

TYP.
R400.01
WET SEAL EXISTING ALUMINUM
RIBBON WINDOW ASSEMBLY,
TYP.

TYP.

8 INSTALL NEW PRE-FORMED 8


R400.01 SILICONE SHEET AT ALL GANGED R400.01
TYP. MULLION JOINTS, TYP. TYP.
SIM.
TYPICAL CRACK IN STONE
SILL - ROUT AND SEAL IN
ACCORDANCE WITH DETAIL CR
4/R500.06, TYP.
EXISTING METAL SPANDREL Project
PANEL JOINTS. REMOVE AND
D D
REPLACE SEALANT, TYP.
Grady Memorial Hospital
TYPICAL CRACK/SPALL AT 1 2
Facade Rehabilitation - Project
TRAVERTINE CLADDING R500.05 R500.05
TYP.
No. F2016008
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
SPANDREL PANEL - WESTERN ADDITION ENLARGED ELEVATION - WESTERN ADDITION
4 SCALE: 1/2" = 1'-0" 5 SCALE: 1/2" = 1'-0"

TRAVERTINE CLADDING - ENLARGED ELEVATION Client

C
6 SCALE: 1/2" = 1'-0"
C
Grady Memorial Hospital
EXISTING RIBBON WINDOW
80 Jesse Hill Jr. Dr., SE
EXISTING WALL CONSTRUCTION,
TYP.
ASSEMBLY
Atlanta, Georgia 30303
EXISTING PRECAST CONCRETE WET SEAL EXISTING RIBBON WINDOW
PANEL, TYP. ASSEMBLY, TYP.

INSPECT ALL EXISTING SEALANT -


REPLACE FAILED SEALANT IN NEW PRE-FORMED SILICONE
EXISTING WEEP HOLES AT 2'-6" ACCORDANCE WITH DETAILS 1 AND SHEET
O.C. 2/R500.06, TYP.

NEW SILICONE SEALANT


EXISTING METAL PANEL BEAD, TYP.
EXISTING WALL CONSTRUCTION,
NEW BACKER ROD AND SEALANT TYP.
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

EXISTING WEEP HOLES AT 2'-6"


EXISTING METAL PANEL
B O.C. - SEAL WITH SILICONE B
SEALANT, TYP.
Mark Date Description
INSPECT ALL EXISTING SEALANT -
INSTALL NEW BACKER ROD AND 0 1/2" 1" 2"
REPLACE FAILED SEALANT IN INSPECT AND REPLACE
SEALANT AT OPEN JOINT
ACCORDANCE WITH DETAILS 1 AND FAILED GLAZING SEALANT,
BETWEEN PRECAST CONCRETE
2/R500.06, TYP. TYP. THIS SHEET PLOTS FULL SIZE
AND METAL PANEL AT 30x42 (INCHES)
WET SEAL EXISTING RIBBON WINDOW V.I.F.
ASSEMBLY, TYP. EXISTING ALUMINUM RIBBON
EXISTING PRECAST CONCRETE WINDOW SYSTEM, TYP. Project No. 2016.1879
EXISTING RIBBON WINDOW PANEL, TYP.
ASSEMBLY
Date 3/6/17

Drawn WL, KM

Checked LC

Scale As Noted
PARTIAL WALL SECTION AT HEAD PARTIAL WALL SECTION AT SILL GANGED MULLION JOINT DETAIL
A
7 SCALE: 1 1/2" = 1'-0" 8 SCALE: 1 1/2" = 1'-0" 9 SCALE: 1' = 1'-0"
A
Enlarged Elevations

Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R400.01
1 2 3 4 5 6 7 8 9 10

Masonry Repair Details.dwg


Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R500.01 Brick

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
EXISTING BRICK VENEER TO EXISTING WEATHER-RESISTIVE EXISTING CLAY TILE, CMU, OR
BARRIER, TYP.
REMOVE AND REPLACE THE FIRST FOUR COURSES EXISTING CLAY TILE, CMU, OR
BRICK MASONRY BACK-UP WALL
Wiss, Janney, Elstner Associates, Inc.
REMAIN, TYP. BRICK MASONRY BACK-UP WALL REMOVE AND REPLACE TWO COURSES OF BRICK
OF BRICK BEARING ON THE SHELF ANGLE. 2915 Premiere Parkway, Suite 100
AND CAST STONE HEADER AS SHOWN.
REPLACEMENT BRICK TO MATCH EXISTING.
EXISTING CLAY TILE, CMU, OR BRICK CONTRACTOR TO SUBMIT REPLACEMENT BRICK FOR
REPLACEMENT BRICK TO MATCH EXISTING. Duluth, Georgia 30097
EXISTING WEATHER-RESISTIVE CONTRACTOR TO SUBMIT REPLACEMENT BRICK FOR
REMOVE AND REPLACE THE FIRST FOUR COURSES MASONRY BACK-UP WALL APPROVAL PRIOR TO REPLACEMENT BARRIER, TYP. EXISTING WEATHER-RESISTIVE
770.923.9822 tel | 770.232.9044 fax
OF BRICK BEARING ON THE SHELF ANGLE AND THE APPROVAL PRIOR TO REPLACEMENT
www.wje.com
FIRST COURSE OF BRICK BENEATH THE SHELF BARRIER, TYP.
ANGLE. REPLACEMENT BRICK TO MATCH EXISTING. NEW URETHANE SEALANT
NEW URETHANE SEALANT NEW MORTAR NETTING
CONTRACTOR TO SUBMIT REPLACEMENT BRICK FOR NEW MORTAR NETTING
NEW URETHANE SEALANT
APPROVAL PRIOR TO REPLACEMENT NEW S.S. TERMINATION BAR
NEW S.S. TERMINATION BAR NEW SELF-ADHERED FLASHING. PRIOR TO ANCHORED AT 12" O.C. MAX INSTALL NEW WEEP VENTS AT 24"
ANCHORED AT 12" O.C. MAX INSTALLATION, CLEAN/REMOVE EXISTING
NEW SELF-ADHERED FLASHING. PRIOR TO O.C.MAX
DAMP PROOFING IN ACCORDANCE WITH NEW S.S. TERMINATION BAR

G
INSTALLATION, CLEAN/REMOVE EXISTING NEW MORTAR NETTING FLASHING MANUFACTURER'S ANCHORED AT 12" O.C. MAX

6" MIN.
L
DAMP PROOFING IN ACCORDANCE WITH RECOMMENDATIONS TO ENSURE PROPER NEW SILICONE-MODIFIED ACRYLIC

IN
FLASHING MANUFACTURER'S ADHESION TO THE SUBSTRATE COATING, TYP.

6" MIN.
RECOMMENDATIONS TO ENSURE PROPER
ADHESION TO THE SUBSTRATE 1/4"
EXISTING STEEL SHELF ANGLE/LINTEL. CLEAN,
PRIME, AND PAINT WITH A RUST INHIBITIVE N

D
INSTALL NEW WEEP VENTS AT 24" O.C.,
EXISTING STEEL SHELF ANGLE/LINTEL. CLEAN,
O

6" MIN.
1/4" MAXIMUM PAINT. CONTRACTOR AND ARCHITECT/ENGINEER NEW SELF-ADHERED FLASHING. PRIOR TO
PRIME, AND PAINT WITH A RUST INHIBITIVE

D
INSTALL NEW WEEP VENTS AT 24" TO VERIFY ANCHORAGE OF EXISTING SHELF EXISTING STEEL SHELF ANGLE/LINTEL. CLEAN,
PAINT. CONTRACTOR AND ARCHITECT/ENGINEER INSTALLATION, CLEAN/REMOVE EXISTING
O.C., MAXIMUM NEW 28 GAUGE S.S.DRIP FLASHING. ANGLE/LINTEL PRIOR TO REMOVAL OF BRICK DAMP PROOFING IN ACCORDANCE WITH
PRIME, AND PAINT WITH A RUST INHIBITIVE
S

BI
TO VERIFY ANCHORAGE OF EXISTING SHELF PAINT. CONTRACTOR AND ARCHITECT/ENGINEER
COURSE BELOW ANGLE
G
NEW 28 GAUGE S.S.DRIP FLASHING.
ANGLE/LINTEL PRIOR TO REMOVAL OF BRICK
COURSE BELOW ANGLE
BED METAL FLASHING IN CONTINUOUS
BED OF SEALANT. SEE DETAILS 1 AND
FLASHING MANUFACTURER'S
RECOMMENDATIONS TO ENSURE PROPER
TO VERIFY ANCHORAGE OF EXISTING SHELF
ANGLE/LINTEL PRIOR TO REMOVAL OF BRICK
G

SE

R
2/R500.02 FOR SPLICE JOINTS AND ADHESION TO THE SUBSTRATE
BED METAL FLASHING IN CONTINUOUS COURSE BELOW ANGLE
INSIDE/OUTSIDE CORNER DETAILS

FO
BED OF SEALANT. SEE DETAILS 1 AND
ROUT AND SEAL ALL JOINTS IN CAST
2/R500.02 FOR SPLICE JOINTS, AND
INSIDE/OUTSIDE CORNER DETAILS
STONE SURROUNDS, TYP.
NEW BACKER ROD AND SEALANT
P
NEW BACKER ROD AND SEALANT NEW 28 GAUGE S.S.DRIP FLASHING.
Consultants
R
U
BED METAL FLASHING IN CONTINUOUS
NEW BACKER ROD AND SEALANT BED OF SEALANT. SEE DETAILS 1 AND EXISTING ALUMINUM-FRAMED WINDOW
3
8" JOINT TO REMAIN BETWEEN TOP OF NEW
BRICK AND BOTTOM OF SHELF ANGLE. FILL
JOINT WITH PRE-FORMED NEOPRENE
EXISTING ALUMINUM-FRAMED RIBBON
WINDOW SYSTEM
2/R500.02 FOR SPLICE JOINTS AND
INSIDE/OUTSIDE CORNER DETAILS
SYSTEM
P
EXPANSION JOINT FILLER

TYPICAL SHELF ANGLE REPAIR DETAIL TYPICAL HEAD FLASHING AT RIBBON WINDOW TYPICAL HEAD FLASHING AT PUNCHED OPENING
F 1 SCALE: 3" = 1'-0" 2 SCALE: 3" = 1'-0" 3 SCALE: 3" = 1'-0" F

EXISTING BRICK VENEER TO REMAIN, TYP.


EXISTING WEATHER-RESISTIVE
BARRIER
NEW SELF-ADHERED FLASHING MEMBRANE.
PRIOR TO INSTALLATION, CLEAN/REMOVE EXISTING ALUMINUM-FRAMED
NEW TERMINATION BAR AND
EXISTING DAMP PROOFING IN ACCORDANCE RIBBON WINDOW SYSTEM
URETHANE SEALANT
WITH THE FLASHING MANUFACTURER'S
RECOMMENDATIONS TO ENSURE PROPER NEW SILICONE SEALANT AT WINDOW EXISTING ALUMINUM-FRAMED WINDOW
ADHESION TO THE SUBSTRATE EXISTING CLAY TILE, CMU, OR BRICK PERIMETER SYSTEM
MASONRY BACK-UP WALL EXISTING CAST STONE JAMB

EXISTING BRICK VENEER TO BE REMOVED, TYP. COAT EXISTING EXPOSED CAST COAT EXISTING EXPOSED CAST
STONE ELEMENTS WITH NEW STONE ELEMENTS WITH NEW
NEW MORTAR NETTING ACRYLIC COATING, TYP. ACRYLIC COATING, TYP.
INSTALL NEW WEEP VENTS AT 24" O.C.

ROUT AND SEAL ALL VERTICAL AND NEW SILICONE SEALANT AT


NEW TWO-PIECE S.S. 28-GA. BASE OF WALL 1/2" MIN.
E NEW GROUT TO FILL CAVITY SKYWARD FACING JOINTS IN CAST WINDOW PERIMTER E
FLASHING AND ROOF COUNTERFLASHING - STONE - SEE DETAIL 8/R500.05, TYP.,
ANCHOR COUNTERFLASHING 8" O.C. WITH S.S. BELOW NEW BASE-OF-WALL
FLASHING SIM.
SCREW AND GASKET. SEE DETAILS 1 AND
2/R500.02 FOR SPLICE JOINTS AND ROUT AND SEAL JOINTS IN CAST
INSIDE/OUTSIDE CORNER DETAILS. EXISTING CAST STONE SILL - STONE, TYP. SEE DETAIL 8/R.500.05
ANCHORAGE NOT SHOWN FOR
CLARITY
EXISTING CAST STONE SILL -
EXISTING ROOF TERMINATION - DETAIL EXISTING CLAY TILE, CMU, OR
EXISTING CONCRETE ROOF/FLOOR ANCHORAGE NOT SHOWN FOR
VARIES BY ROOF AREA - NOT IN SCOPE BRICK MASONRY BACK-UP WALL
SLAB CLARITY
EXISTING ROOF MEMBRANE ASSEMBLY TO NEW BACKER ROD AND SEALANT,
VARIES

REMAIN - PREVENT ALTERATIONS AS NOT TYP.


TO VOID EXISTING WARRANTIES
NEW BACKER ROD AND SEALANT,
EXISTING BRICK VENEER TO TYP.
REMAIN, TYP.

EXISTING BRICK VENEER TO


EXISTING CLAY TILE, CMU, OR REMAIN, TYP.
BRICK MASONRY BACK-UP WALL
Project

D D
Grady Memorial Hospital
Facade Rehabilitation - Project
No. F2016008
TYPICAL BASE-OF-WALL FLASHING REPAIR TYPICAL SILL REPAIR AT RIBBON WINDOW TYPICAL SILL REPAIR AT PUNCHED OPENING
4 SCALE: 3" = 1'-0" 5 SCALE: 3" = 1'-0" 6 SCALE: 3" = 1'-0" 80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303

REMOVE, STORE, AND REINSTALL EXISTING


CAST STONE COPING - ANCHORED TO
4 4
R500.04 R500.04
MATCH EXISTING Client
SIM.
C EXISTING CAST STONE COPING C

NEW CMU BACK-UP WALL, FULLY GROUTED WITH


Grady Memorial Hospital
4
R500.04
#5 REBAR AT 16" O.C. FULLY GROUTED
80 Jesse Hill Jr. Dr., SE
EXISTING CLAY TILE, CMU, OR BRICK
NEW EPDM SLIP SHEET
Atlanta, Georgia 30303
> 12" TO TOP OF FLASHING

EXISTING CAST STONE COPING MASONRY BACK-UP WALL NEW WEATHER-RESISTIVE BARRIER, TYP.

NEW TERMINATION BAR AND URETHANE


SEALANT
NEW 28 GA S.S. COUNTERFLASHING BEDDED
IN SEALANT, ANCHORS AT 12" O.C.
EVALUATE MORTAR AT ALL
12" MAX

PARAPET WALLS - A/E TO NEW BRICK VENEER TO MATCH EXISTING, TYP.


IDENTIFY AREAS TO BE
REPOINTED, TYP. EXISTING ROOF TERMINATION - DETAIL
VARIES BY ROOF AREA - NOT IN SCOPE EXISTING ROOF MEMBRANE ASSEMBLY.
TERMINATION DETAIL/HEIGHT VARIES BY ROOF
EXISTING ROOF MEMBRANE ASSEMBLY EXISTING ROOF MEMBRANE ASSEMBLY TO LEVEL - DO NOT MODIFY
EXISTING CLAY TILE, CMU, REMAIN - PREVENT ALTERATIONS TO VOID
OR BRICK MASONRY TO REMAIN - PREVENT ALTERATIONS
AS NOT TO VOID EXISTING EXISTING WARRANTIES
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without

BACK-UP WALL NEW #5 REBAR EMBEDDED IN EXISTING


permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

WARRANTIES EVALUATE MORTAR AT ALL


CONCRETE SLAB 6" MINIMUM - SET IN EPOXY

1'-6"
PARAPET WALLS - A/E TO
B B
IDENTIFY AREAS TO BE
EXISTING CONCRETE SLAB REPOINTED, TYP. EXISTING CONCRETE SLAB
Mark Date Description
0 1/2" 1" 2"

EXISTING CONCRETE SLAB


THIS SHEET PLOTS FULL SIZE
AT 30x42 (INCHES)

4 Project No. 2016.1879


R500.01 4
SIM. R500.01
Date 3/6/17
SIM.

Drawn WL, KM

Checked LC

Scale As Noted

A
PARAPET WALL FLASHING REPAIR - TYPE 1 PARAPET WALL FLASHING REPAIR - TYPE 2 REBUILD PARAPET WALL SECTION
A Brick Masonry Repair
7 8 9
SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0"
Details
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R500.01
1 2 3 4 5 6 7 8 9 10

Masonry Details.dwg
Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R500.02 Brick

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

1/4 IN.
H SELF-ADHERING MEMBRANE FLASHING H
(FULLY ADHERE MEMBRANE TO METAL AS
Wiss, Janney, Elstner Associates, Inc.
SPECIFIED IN THE PROJECT MANUAL)
2915 Premiere Parkway, Suite 100
EXPANSION JOINT VARIES Duluth, Georgia 30097
EXTENTS OF EXISTING LEAD
COATED COPPER EXPANSION JOINT V.I.F 770.923.9822 tel | 770.232.9044 fax
www.wje.com

NEW SILICONE SEALANT AND BACKER


ROD OR BOND-BREAKER TAPE, TYP.
EXISTING BRICK MASONRY VENEER
TO REMAIN, TYP.

WELDED CORNER SECTION OF EXISTING LEAD-COATED


EXTENTS OF EXISTING BRICK
12" M
Y

G
12" END DAM IN. COPPER EXPANSION JOINT TO BE
MIN WELDED CORNER SURROUNDING EACH SHELF

L
. REMOVED, TYP.
ANGLE/LINTEL TO BE REMOVED AND
TYP.

IN
.,
12" MIN REPLACED, TYP.
5 N

D
EXISTING STEEL SHELF
R500.02
O

D
ANGLE/LINTEL. CLEAN,
PRIME, AND PAINT WITH
S

BI
HORIZONTAL S.S. FLASHING
G
HORIZONTAL S.S.FLASHING
A RUST INHIBITIVE
PAINT. CONTRACTOR
G

SE

R
ADHERE METAL-TO-METAL AND
ARCHITECT/ENGINEER

O
LAPS WITH THREE ROWS OF

FO
BUTYL SEALANT, TYP. TO VERIFY
INSIDE CORNER DETAIL OUTSIDE CORNER DETAIL INSIDE CORNER DETAIL
METAL DRIP FLASHING COVER
ANCHORAGE OF
EXISTING SHELF
4
R500.02
P
R
PLATE ANGLE/LINTEL PRIOR
Consultants

HEMMED EDGE OF COVER PLATE


TO NEST OVER HEMMED EDGE
P U
OF FLASHING

TYPICAL PREFABRICATED SHEET METAL FLASHING TYPICAL SPLICE DETAIL NEW EXPANSION JOINT DETAIL
1 SCALE: 3" = 1'-0" 2 SCALE: 3" = 1'-0" 3 SCALE: 1 1/2" = 1'-0"

F F

EXISTING BRICK VENEER TO REMAIN, EXISTING BACKUP TO REMAIN,


TYP. TYP.
EXISTING WEATHER-RESISTIVE
BARRIER, TYP.
EXISTING LEAD-COATED COPPER NEW S.S. DRIP EDGE FLASHING
EXPANSION JOINT, TYP. TERMINATES AT EXPANSION JOINT,
EXISTING CLAY TILE, CMU, OR TYP.
BRICK MASONRY BACK-UP WALL
E EXISTING EXPANSION JOINT E
EXISTING BRICK VENEER TO BE
ANCHORS TO BE REMOVED, NEW S.S. SPLICE COVER WITH
REMOVED, TYP. SEE DETAIL 1/R500.01
TYP. BACK LEG - INSTALL SIMILAR TO
FOR WATERPROOFING DETAILS AND URETHANE SEALANT
TYPICAL SHELF ANGLE REPAIR DETAIL 2/R500.02

NEW ALUMINUM TERMINATION BAR EXISTING CLAY TILE, CMU, OR


ANCHORED AT 12" O.C. MAX BRICK MASONRY BACK-UP WALL,
TYP.
NEW MORTAR NETTING EXISTING FACE BRICK TO REMAIN,
EXISTING LEAD COATED COPPER TYP. 3"
EXPANSION JOINT TO BE REMOVED
NEW SILICONE SEALANT AND
AT NEW THROUGH-WALL FLASHING
BACKER ROD
REPAITS
EXISTING STEEL SHELF
NEW S.S. DRIP EDGE FLASHING - ANGLE/LINTEL. CLEAN, PRIME, AND EXISTING BRICK MASONRY
SEE DETAIL 6/R500.02 FOR PAINT WITH A RUST INHIBITIVE VENEER TO BE REMOVED
INSTALLATION AT EXPANSION PAINT. CONTRACTOR AND AND REPLACED, TYP. EXISTING EXPANSION JOINT TO REMAIN.
JOINT ARCHITECT/ENGINEER TO VERIFY ENSURE JOINT IS FULL DEPTH OF BRICK
ANCHORAGE OF EXISTING SHELF NEW BOND-BREAKER TAPE MASONRY - SPLICE NEW FLASHING AT
ANGLE/LINTEL PRIOR TO REMOVAL OR BACKER-ROD, AND EXPANSION JOINT
NEW BACKER ROD AND SEALANT OF BRICK COURSE BELOW ANGLE SEALANT 1" TYP.

Project
3
8"
JOINT TO REMAIN BETWEEN TOP OF NEW
D BRICK AND BOTTOM OF SHELF ANGLE. FILL D
JOINT WITH PRE-FORMED FOAM EXPANSION
JOINT FILLER
Grady Memorial Hospital
NOTE: SELF-ADHERED MEMBRANE FLASHING NOT SHOWN FOR CLARITY Facade Rehabilitation - Project
No. F2016008
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
TYPICAL SECTION AT EXPANSION JOINT TYPICAL EXPANSION JOINT REMOVAL DETAIL FLASHING AT EXPANSION JOINT DETAIL
4 SCALE: 3" = 1'-0" 5 SCALE: 3" = 1'-0" 6 SCALE: 3" = 1'-0"

Client

C C
Grady Memorial Hospital
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303

REMOVE MORTAR FROM ONE SIDE OF INSTALL SECOND AND THIRD 1/4
EXISTING MORTAR JOINTS IN. THICK LAYER OF
JOINT USING HAND TOOLS (HAMMER AND
MAKE NARROW CUT ALONG CHISEL) ONLY. CUT FROM EDGE OF PREHYDRATED POINTING
EXISTING MORTAR BED JOINT
CENTER OF JOINT. ADJACENT MASONRY TOWARD CENTER. ADJACENT MORTAR. TOOL MORTAR TO A
MASONRY UNITS ALONG JOINT AS MASONRY UNITS ALONG JOINT AS WELL REPEAT STEP 2 TO REMOVE MORTAR CONCAVE FINISH WHEN IT IS
DO NOT DAMAGE BRICK OR WELL AS AT ENDS OF JOINT AS AT ENDS OF JOINT SHALL NOT BE FROM OTHER SIDE OF JOINT. REMOVE "THUMBPRINT" HARD.
STONE UNITS. ALL DAMAGED SHALL NOT BE DAMAGED DURING DAMAGED DURING THIS PROCESS. DO NOT ALL DUST AND DEBRIS.
UNITS MUST BE REPLACED. CUTTING OF JOINTS WIDEN JOINT.
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without

"HALF-MOONS" CREATED BY GRINDER


permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

STEPS 2 AND 3
ARE UNACCEPTABLE & MUST BE
B REMOVED TO ACHIEVE A UNIFORM 3 4" B
MIN. DEPTH
Mark Date Description
REMOVE EXCESS MORTAR @ TOP & MOISTEN JOINTS AND ALLOW
0 1/2" 1" 2"
BOTTOM OF HEAD JOINT LEFT BY MANUAL JOINTS TO SURFACE DRY BEFORE
CHIPPING OR OTHER MEANS APPLYING MORTAR. INSTALL FIRST
LAYER OF PREHYDRATED MORTAR THIS SHEET PLOTS FULL SIZE
HEAD JOINT 1/4 IN. DEEP. TOOL MORTAR AFTER AT 30x42 (INCHES)

IT BECOMES "THUMBPRINT" HARD.


BRICK OR LIMESTONE FACE
STEP 1 STEP 2 STEP 3
Project No. 2016.1879

3/4 IN. OR UNTIL SOUND MORTAR, Date 3/6/17


WHICHEVER IS GREATER. STEP 1
Drawn WL, KM

Checked LC

Scale As Noted

A
7
REPOINTING ISOMETRIC
N.T.S. 8
REPOINTING - MORTAR REMOVAL
N.T.S. 9
REPOINTING - NEW MORTAR APPLICATION
N.T.S.
A Brick Masonry Repair
Details
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R500.02
1 2 3 4 5 6 7 8 9 10

Masonry Repair Details.dwg


Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R500.03 Brick

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
770.923.9822 tel | 770.232.9044 fax
www.wje.com

8" MAX. 32" APPROX.

G
2 1
L

IN
APPROXIMATE LOCATION OF EXISTING
R500.01 R500.01
TYP. TYP. STEEL SHELF ANGLE
N

D
O

D
APPROXIMATE EXTENT OF NEW
THROUGH-WALL FLASHING REPAIRS
S

BI
E

8"
G G

R
24" APPROX.
O

FO
SEE DETAIL 2/R400.01 FOR
TYPICAL REPAIRS TO RIBBON
P
R
WINDOWS
Consultants
NEW SUPPLEMENTAL REPAIR ANCHOR.
TYP. OFFSET SUPPLEMENTAL ANCHORS
HORIZONTALLY AND VERTICALLY FROM
P U
EXISTING BRICK REPAIR ANCHORS

4
F R500.03 F
TYP.

SUPPLEMENTAL ANCHOR PATTERN


2 SCALE: 1/2" = 1'-0"

TYPICAL METAL PANEL REPAIR AT INSIDE CORNER


1 SCALE: 3/4" = 1'-0"

E E
V.I.F.

EXISTING CLAY TILE, CMU, OR BRICK EXISTING BACKUP WALL


MASONRY BACK-UP WALL, TYP.
MASONRY TIE ANCHOR
INSTALLED AT 16" O.C.
INSTALL NEW HELICAL MASONRY HORIZONTALLY AND
REPAIR ANCHORS AT APPROXIMATELY VERTICALLY IN REBUILT
24" O.C. VERTICALLY AND 32" O.C. MASONRY AREAS, TYP.
EXISTING FLASHING OVER SCUPPER - HORIZONTALLY
BEND AS NECESSARY TO INSTALL NEW
1" MIN.

PRE-FORMED SILICONE REPAIRS. RETURN


FLASHING TO ORIGINAL CONDITION EXISTING BRICK VENEER TO REMAIN,
TYP.

APPROX. 2'-0"
EXISTING LEAD-COATED COPPER EXISTING WALL CAVITY MIN. 112"
ROOF OVERFLOW SCUPPER REBUILT BRICK FACADE MORTAR EMBEDMENT
Project
EXISTING DAMP PROOFING
D D
NEW PRE-FORMED SILICONE SEALANT, TYP.
Grady Memorial Hospital
5
8" MIN.

EXISTING BRICK VENEER TO REMAIN, TYP.


MORTAR COVER Facade Rehabilitation - Project
No. F2016008
80 Jesse Hill Jr. Dr., SE
1" MIN. 3" TYP.
Atlanta, Georgia 30303

ROOF OVERFLOW SCUPPER REPAIR MASONRY REPAIR ANCHOR DETAIL MASONRY TIE ANCHOR DETAIL
3 SCALE: 3" = 1'-0" 4 SCALE: 1 1/2" = 1'-0" 5 SCALE: 6" = 1'-0"

Client

C C
5 Grady Memorial Hospital
R500.03
TYP. 80 Jesse Hill Jr. Dr., SE
REMOVE AND REPLACE EXISTING BRICK VENEER
WALL - SEE ELEVATIONS FOR LOCATIONS. Atlanta, Georgia 30303
REPLACEMENT BRICK TO MATCH EXISTING.
CONTRACTOR TO SUBMIT REPLACEMENT BRICK FOR
APPROVAL PRIOR TO REPLACEMENT

NEW MASONRY TIE ANCHOR

EXISTING WEATHER-RESISTIVE
BARRIER, TYP.
1
R500.01
SIM.
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

EXISTING STEEL SHELF ANGLE/LINTEL. CLEAN,


B PRIME, AND PAINT WITH A RUST INHIBITIVE B
PAINT. CONTRACTOR AND ARCHITECT/ENGINEER
TO VERIFY ANCHORAGE OF EXISTING SHELF Mark Date Description
ANGLE/LINTEL PRIOR TO REMOVAL OF BRICK
6" MIN.

0 1/2" 1" 2"


COURSE BELOW ANGLE

THIS SHEET PLOTS FULL SIZE


1/4" AT 30x42 (INCHES)

NEW THROUGH-WALL FLASHING - SEE Project No. 2016.1879


DETAIL 1/R500.01
Date 3/6/17

EXISTING CLAY TILE, CMU, OR BRICK Drawn WL, KM


MASONRY BACK-UP WALL
Checked LC

Scale As Noted

A A Brick Masonry Repair


BRICK VENEER REPAIR DETAIL Details
6 SCALE: 3" = 1'-0"

Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R500.03
1 2 3 4 5 6 7 8 9 10

Masonry Repair Details.dwg


Plotted: 3/20/2017 11:32 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R500.04 Brick

ENGINEERS
EXISTING MASS MASONRY WALL ARCHITECTS
MATERIALS SCIENTISTS

REMOVE AND REPLACE SEALANT AT PERIMETER EXISTING EXISTING BRICK VENEER WALL
H H
OF SADDLE FLASHING
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
NEW CANT BEAD OF SILICONE SEALANT AT Duluth, Georgia 30097
HEMMED EDGE OF SADDLE FLASHING
P. TYPICAL SPLICE JOINT IN PREFINISHED 770.923.9822 tel | 770.232.9044 fax
TY EXISTING SADDLE FLASHING
3" SHEET METAL COPING - REMOVE FAILED www.wje.com
SEALANT
NEW SEALANT JOINT BETWEEN
EXISTING BRICK MASONRY WALL
AND CAST STONE COPING
EXISTING PREFINISHED TYPICAL SHEET NEW PRE-FORMED SILICONE SHEET
BEDDED IN SEALANT NEW PRE-FORMED SILICONE SEALANT BED IN
METAL COPING
THREE LINES OF SILICONE SEALANT

G
EXISTING CAST STONE COPING

IN
EXISTING CAST STONE COPING

N
EXISTING CAST STONE COPING
EXISTING BRICK VENEER, TYP.

D
SEALANT JOINT AND BOND BREAKER
O

D
TAPE BETWEEN BRICK MASONRY AND
SEALANT JOINT AND BOND BREAKER SEALANT JOINT AND BOND BREAKER
UNDERSIDE OF CAST STONE COPING,
S

BI
TAPE BETWEEN BRICK MASONRY AND TAPE BETWEEN BRICK MASONRY AND
G UNDERSIDE OF CAST STONE COPING,
TYP.
UNDERSIDE OF CAST STONE COPING,
TYP.
TYP. G

SE

R
.
O

FO
YP EXISTING CLAY TILE, CMU, OR BRICK
EXISTING CLAY TILE, CMU, OR BRICK 3"T
MASONRY BACK-UP WALL, TYP.
EXISTING CLAY TILE, CMU, OR BRICK
MASONRY BACK-UP WALL, TYP.
P
MASONRY BACK-UP WALL, TYP.
Consultants
R
EXISTING EXISTING BRICK VENEER
PARAPET WALL
P U
EXISTING EXISTING BRICK VENEER PARAPET
WALL

SHEET METAL COPING REPAIR SHEET METAL COPING - PARAPET TO WALL NEW SADDLE FLASHING DETAIL
F 1 SCALE: 1 1/2" = 1'-0" 2 SCALE: 1 1/2" = 1'-0" 3 SCALE: 1 1/2" = 1'-0" F

VERIFY IN FIELD

EXISTING BRICK VENEER TO REMAIN, TYP.

EXISTING SHEET METAL ROOF TERMINATION EXISTING THROUGH-WALL FLASHING TO


REMAIN
EXISTING ANCHOR POCKET - REMOVE
LOOSE MATERIAL AND INSTALL NEW NEW ONE-INCH CANT BEAD OF SEALANT
FIELD VERIFY SILYL-TERMINATED POLYURETHANE
SEALANT NEW PEDESTRIAN TRAFFIC BEARING MEMBRANE
EXISTING CAST STONE LEDGE. CLEAN, PRIME, AND BASE COAT
EXISTING DOWEL TO REMAIN
SEAL CRACKS, CLEAN, AND COAT WITH NEW
SILICONE MODIFIED ACRYLIC COATING. NEW PEDESTRIAN TRAFFIC BEARING MEMBRANE
CONTRACTOR TO CLEAN, PRIME, AND COAT
EXISTING CAST STONE COPING SUBSTRATE
2" WEARING SURFACE COAT

3" MIN.
WITH NEW ACRYLIC COATING
E PREPARE SUBSTRATE AND PRIME AS REQUIRED E
6"
REMOVE EXISTING SILICONE SEALANT
BETWEEN COPING. ROUT AND SEAL
COPING JOINTS AND REPLACE WITH NEW
SILYL-TERMINATED POLYURETHANE EXISTING BRICK VENEER TO REMAIN, TYP.
6"
SEALANT, TYP.

EXISTING CAST STONE COPING TO REMAIN

COAT VERTICAL FACE AND UNDERSIDE OF


EXISTING CLAY TILE, CMU, OR BRICK
CONCRETE SLAB WITH NEW ACRYLIC COATING
MASONRY BACK-UP WALL, TYP.

EXISTING CAST-IN-PLACE CONCRETE LEDGE -


ROUT AND SEAL CRACKS AND REPAIR SPALLS -
SEE DETAIL 8/R500.05, SIM.
Project

D NEW BACKER ROD AND SEALANT D


CAST COPING STONE REPAIR DETAIL ROOF LEDGE DETAIL Grady Memorial Hospital
4 SCALE: 3" = 1'-0" 5 SCALE: 1 1/2" = 1'-0" EXISTING BACK-UP WALL CONSTRUCTION

TRAFFIC BEARING MEMBRANE AT OVERHANG Facade Rehabilitation - Project


6 SCALE: 3" = 1'-0"
No. F2016008
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
EXISTING REINFORCING BARS ADD HELICAL PINS AT 8 INCHES O.C.
WITH A MINIMUM OF THREE ANCHORS
EXISTING ALUMINUM-FRAMED REMOVE UNSOUND AND SOUND
COAT EXISTING EXPOSED CAST PER PATCH
RIBBON WINDOW SYSTEM CONCRETE FROM REPAIR AREA - CAST
STONE ELEMENTS WITH NEW
TO RESTORE ORIGINAL CROSS-SECTION
ACRYLIC COATING, TYP.
USING THE SPECIFIED REPAIR PATCH CHIP CONCRETE TO A DEPTH OF
MATERIAL. SEE SPECIFICATION 03 01 31 3/4" BELOW REINFORCING STEEL
ROUT AND SEAL ALL JOINTS IN CAST EXISTING CAST STONE SILL -
2" MIN. ANCHORAGE NOT SHOWN FOR
STONE - SEE DETAIL 8/R500.05, TYP., NEW COATING WHERE REQUIRED AT 3/8" SAWCUT AROUND PERIMETER OF
SIM. CLARITY TOPSIDE AND VERTICAL CONCRETE PATCH AREA - BEVEL SAWCUT AWAY Client
SURFACES. FROM CENTER OF PATCH AREA
NEW HELICAL PINS AT 8" O.C. AND A
C MINIMUM OF (2) ANCHORS PER PATCH C
NEW BACKER ROD AND SEALANT-
SEE DETAILS 1 AND 2/R500.06, TYP. Grady Memorial Hospital

1-1/2" MAX
EXTENT OF CONCRETE REMOVAL
EXISTING BRICK VENEER TO
80 Jesse Hill Jr. Dr., SE
CLEAN AND COAT EXISTING REMAIN, TYP.
Atlanta, Georgia 30303

CLEARANCE
REINFORCING STEEL

3/4" MIN.
NEW REPAIR CONCRETE TO MATCH
EXISTING PROFILE, SURFACE EXISTING CLAY TILE, CMU, OR
TEXTURE, FINISH, AND COLOR BRICK MASONRY BACK-UP WALL

EXISTING REINFORCED CONCRETE SUN SHADE


NOTES:

THIS REPAIR DETAIL APPLIES TO CONCRETE SPALLS LOCATED ON THE TOP, UNDERSIDE, AND VERTICAL EDGES OF THE CONCRETE SUN SHADES AND PROMENADE.
NOTES:
1. REMOVE ALL LOOSE CONCRETE FROM THE AFFECTED AREA. IF REPAIR AREA EXCEEDS EIGHT SQUARE FEET, SHORING MAY BE REQUIRED AND CONTRACTOR SHALL NOTIFY REPAIR PROCEDURES:
ARCHITECT/ENGINEER PRIOR TO DEMOLITION. LOCATE ALL EMBEDDED ITEMS PRIOR TO DEMOLITION.
1. REMOVE ALL LOOSE CONCRETE FROM THE AFFECTED AREA. IF REPAIR AREA EXCEEDS EIGHT SQUARE FEET, SHORING MAY BE REQUIRED AND CONTRACTOR SHALL NOTIFY ARCHITECT/ENGINEER PRIOR TO DEMOLITION. LOCATE ALL
2. MAKE A 3/8 INCH DEEP SAW-CUT AROUND THE PERIMETER OF THE AFFECTED AREA. THE SAW-CUTS SHALL BE A MINIMUM OF 2 INCHES OUTSIDE THE AREA OF DISTRESS. THE SHAPE OF EACH EMBEDDED ITEMS PRIOR TO DEMOLITION.
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

SAW-CUT AREA SHALL NOT BE IRREGULAR.


2. MAKE A 3/8 INCH DEEP SAW-CUT AROUND THE PERIMETER OF THE AFFECTED AREA. THE SAW-CUTS SHALL BE A MINIMUM OF 2 INCHES OUTSIDE THE AREA OF DISTRESS. THE SHAPE OF EACH SAW-CUT AREA SHALL NOT BE IRREGULAR.
B B
3. USE CHIPPING HAMMERS OF NOMINAL 15-LB CLASS OR LESS TO REMOVE ALL LOOSE AND UNSOUND CONCRETE IN THE AREA BOUND BY THE SAW-CUTS. CONTINUE TO CHIP INTO THE
UNDERLYING SOUND CONCRETE AND REMOVE IT TO A DEPTH OF AT LEAST 3/4 INCH BEYOND THE FIRST MAT OF EXPOSED REINFORCING STEEL. DO NOT DAMAGE EXISTING REINFORCING 3. USE CHIPPING HAMMERS OF NOMINAL 15-LB CLASS OR LESS TO REMOVE ALL LOOSE AND UNSOUND CONCRETE IN THE AREA BOUND BY THE SAW-CUTS. CONTINUE TO CHIP INTO THE UNDERLYING SOUND CONCRETE AND REMOVE IT TO A
DEPTH OF AT LEAST 3/4 INCH BEYOND THE FIRST MAT OF EXPOSED REINFORCING STEEL. DO NOT DAMAGE EXISTING REINFORCING DURING DEMOLITION. IF REINFORCING STEEL IS NOT IDENTIFIED WITHIN THE LIMITS OF THE PATCH, THE Mark Date Description
DURING DEMOLITION. IF REINFORCING STEEL IS NOT IDENTIFIED WITHIN THE LIMITS OF THE PATCH, THE ARCHITECT/ENGINEER SHALL BE NOTIFIED.
ARCHITECT/ENGINEER SHALL BE NOTIFIED. 0 1/2" 1" 2"

4. PROVIDE MIN. SURFACE PROFILE OF ICRI CSP 7 WITH A FRACTURED AGGREGATE SURFACE ON EXISTING SOUND CONCRETE. SEE SPECIFICATION SECTION 03 01 31 FOR ADDITIONAL SURFACE
PREPARATION REQUIREMENTS. 4. PROVIDE MIN. SURFACE PROFILE OF ICRI CSP 7 WITH A FRACTURED AGGREGATE SURFACE ON EXISTING SOUND CONCRETE. SEE SPECIFICATION SECTION 03 01 31 FOR ADDITIONAL SURFACE PREPARATION REQUIREMENTS.
THIS SHEET PLOTS FULL SIZE
AT 30x42 (INCHES)

5. IF EXISTING REINFORCING BARS ARE CORRODED AND HAVE GREATER THAN 10% LOSS IN CROSS SECTION, CONTACT THE ARCHITECT/ENGINEER BEFORE COMPLETING FURTHER WORK AT THE 5. IF EXISTING REINFORCING BARS ARE CORRODED AND HAVE GREATER THAN 10% LOSS IN CROSS SECTION, CONTACT THE ARCHITECT/ENGINEER BEFORE COMPLETING FURTHER WORK AT THE REPAIR.
REPAIR.
6. SANDBLAST THE EXPOSED CONCRETE SURFACES AND REINFORCING STEEL WITHIN THE AREA OF THE PATCH. AGGRESSIVELY BLAST THE SAW-CUT EDGES AROUND THE PERIMETER OF THE REPAIR. IF SAND BLASTING IS NOT ALLOWED, Project No. 2016.1879
6. SANDBLAST THE EXPOSED CONCRETE SURFACES AND REINFORCING STEEL WITHIN THE AREA OF THE PATCH. AGGRESSIVELY BLAST THE SAW-CUT EDGES AROUND THE PERIMETER OF THE ACCEPTABLE ALTERNATIVE CLEANING METHODS INCLUDE:
REPAIR. IF SAND BLASTING IS NOT ALLOWED, ACCEPTABLE ALTERNATIVE CLEANING METHODS INCLUDE: 6.1. ABRASIVE BLAST, TO SSPC-SP 6/NACE NO. 3 FINISH, WITH MINIMAL RUST OR CONCRETE DEBRIS Date 3/6/17
6.1. ABRASIVE BLAST, TO SSPC-SP 6/NACE NO. 3 FINISH, WITH MINIMAL RUST OR CONCRETE DEBRIS 6.2. COMMERCIAL GRADE POWER TOOL CLEANING, TO SSPC-SP 15 AT LOCATIONS EXPLICITLY APPROVED BY A/E IN WRITING. PREPARE TO CONDITION OF MINIMAL RUST OF CONCRETE DEBRIS.
6.2. COMMERCIAL GRADE POWER TOOL CLEANING, TO SSPC-SP 15 AT LOCATIONS EXPLICITLY APPROVED BY A/E IN WRITING. PREPARE TO CONDITION OF MINIMAL RUST OF CONCRETE DEBRIS.
7. PAINT THE EXPOSED REINFORCING STEEL WITH ANTI-CORROSION AGENT PER SPECIFICATION 03 01 31. Drawn WL, KM
7. CLEAN THE ENTIRE AREA OF THE PATCH WITH HIGH-PRESSURE, OIL-FREE COMPRESSED AIR.
8. INSTALL FORMWORK AS REQUIRED AND PLACE CONCRETE, CONSOLIDATED WITH VIBRATORS, TO ACHIEVE COMPLETE FILLING OF THE REPAIR AREA. WET CURE FOR 7 DAYS. Checked LC
8. PAINT THE EXPOSED REINFORCING STEEL WITH ANTI-CORROSION AGENT PER SPECIFICATION 03 01 31.
9. AFTER CONCRETE HAS SUFFICIENTLY CURED, SOUND TEST THE REPAIR AREAS TO DETECT ANY AREAS OF DEBONDED OR DELAMINATED REPAIR CONCRETE. REMOVE AND REPLACE ANY UNSOUND CONCRETE.
Scale As Noted
9. INSTALL FORMWORK AS REQUIRED AND PLACE CONCRETE, CONSOLIDATED WITH VIBRATORS, TO ACHIEVE COMPLETE FILLING OF THE REPAIR AREA. WET CURE FOR 7 DAYS.
10. AFTER CONCRETE REPAIRS AND CURING HAVE BEEN COMPLETED (14 DAYS MINIMUM), PERFORM AN ALKALINITY TEST TO EVALUATE THE ABILITY OF THE SUBSTRATE TO RECEIVE NEW COATING. FOLLOWING ACCEPTABLE ALKALINITY
RESULTS, INSTALL A NEW COATING WHERE REQUIRED AT TOPSIDE, VERTICAL, AND UNDERSIDE CONCRETE SURFACES AS PER DETAIL 6/R500.04 AND MANUFACTURER'S INSTALLATION INSTRUCTIONS.
A
10. AFTER CONCRETE HAS SUFFICIENTLY CURED, SOUND TEST THE REPAIR AREAS TO DETECT ANY AREAS OF DEBONDED OR DELAMINATED REPAIR CONCRETE. REMOVE AND REPLACE ANY
UNSOUND CONCRETE. A Cast Stone and Concrete
TYPICAL SILL REPAIR CONCRETE PATCH REPAIR DETAIL Repair Details
7 SCALE: 3" = 1'-0" 8 SCALE: 3" = 1'-0"

Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R500.04
1 2 3 4 5 6 7 8 9 10

Repair Details.dwg
Plotted: 3/20/2017 11:33 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R500.05 Stone

ENGINEERS
ARCHITECTS
EXISTING THIN STONE, GRANITE, MATERIALS SCIENTISTS
OR MARBLE PANEL, TYP.

MIN. 1/2" REPAIR MORTAR


H H
EXISTING SEALANT IN JOINT TO BE EXISTING SEALANT IN JOINT TO BE REMOVED BEHIND HEAD OF ANCHOR
4 Wiss, Janney, Elstner Associates, Inc.
REMOVED AND REPLACED, TYP. 4 AND REPLACED, TYP.
TYP. R500.05 TYP. 2915 Premiere Parkway, Suite 100
R500.05
SIM. SIM. EXISTING THIN STONE, GRANITE, OR MARBLE 1 Duluth, Georgia 30097
PANEL, TYP. 2" SAWCUT EDGE
EXISTING THIN STONE, GRANITE, OR ALL AROUND PATCH 770.923.9822 tel | 770.232.9044 fax
MARBLE PANEL, TYP. www.wje.com

4" 4" EXISTING KERF FOR STONE ANCHORAGE MIN. 12" CLEAR COVER OVER
EXISTING KERF FOR STONE ANCHORAGE STAINLESS STEEL ELEMENTS

NEW HILTI HIT-HY 70 ADHESIVE ANCHOR NEW HILTI HIT-HY 70 ADHESIVE ANCHOR SCREEN NEW 8MM STAINLESS STEEL HELICAL

3"
3"
SCREEN TUBE REPAIR. PATCHED TO MATCH TUBE REPAIR. PATCHED TO MATCH EXISTING ANCHORS SET 2" MINIMUM INTO SOUND
STONE AND BENT INTO "L" SHAPE
Y

G
EXISTING STONE. SEE DETAIL 4/R500.05 STONE. SEE DETAIL 4/R500.05
AFTER INSTALLATION

IN
EXISTING SPALL LOCATION. SPALL DOES NOT NEW STONE REPAIR MORTAR
N

D
EXISTING SPALL LOCATION. SPALL DOES NOT EXTEND TO
EXTEND TO STONE PANEL BEHIND KERF. IF
SPALLED STONE PIECE IS AVAILABLE,
STONE PANEL BEHIND KERF. IF THE SPALLED STONE
O

D
PIECE IS NOT PRESENT, SAWCUT EDGES OF THE SPALL

S
RE-ADHERE SPALL WITH DOW CORNING 756 NEW BACKER ROD AND SEALANT
TO CREATE A RECTANGULAR PATCH. DO NOT CUT INTO

BI
SMS SEALANT. FILL KERF WITH SEALANT.
STONE SECTION BEHIND EXISTING KERF. ANCHOR PATCH
G WITH NEW 18" DIA. STAINLESS STEEL PINS, SET IN EPOXY.
SEE DETAIL 3/R500.05. PATCH MATERIAL TO BE JAHN
G

SE

R
M160, GRANITE REPAIR MORTAR, OR APPROVED EQUAL.

FO
NOTE: IF THE CRACK AROUND THE SPALLED AREA EXTENDS NOTE: IF THE CRACK AROUND THE SPALLED AREA EXTENDS
THROUGH THE SECTION OF THE STONE PANEL BEHIND THE KERF, THROUGH THE SECTION OF THE STONE PANEL BEHIND THE KERF,
NOTIFY A/E TO DEVELOP ADDITIONAL REPAIR PROCEDURE NOTIFY A/E TO DEVELOP ADDITIONAL REPAIR PROCEDURE
ADDITIONAL REPAIR NOTES: P
1. MIN. PATCH DEPTH IS 1/2" AT PATCH EDGES AND 1-1/2" AT REMAINDER.
Consultants
R
1
STONE PANEL SPALL REPAIR - OPTION A
2
STONE PANEL SPALL REPAIR - OPTION B
2. SEE SPECIFICATIONS FOR SPALL/PATCH SIZE DEFINITIONS AND ADDITIONAL
REQUIREMENTS.
P U
SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0"
3. ANGLED STAINLESS STEEL HEADED STUDS, MIN. 1/8" DIAMETER EPOXY OR EXPANSION SET
INTO STONE WITH MIN. 2" EMBEDMENT MAY BE UTILIZED IN-LIEU OF HELICAL ANCHORS.
EXACT PATCH ANCHORAGE TO BE ESTABLISHED DURING IN-SITU MOCK-UP REPAIR.

4. PATCH MATERIAL TO BE JAHN M160, GRANITE REPAIR MORTAR, OR APPROVED EQUAL.

2" TYP. TYPICAL STONE SPALL REPAIR DETAIL - PATCH


F 3 SCALE: 3" = 1'-0" F

EXISTING THIN STONE, GRANITE, OR MARBLE PANEL,


TYP.

NEW 12" DIAMETER STAINLESS STEEL THREADED ROD WITH


HILTI HIT-SC SCREEN TUBE SET IN HILTI HIT - HY 70
ADHESIVE. PROVIDE OPENING IN SEALANT JOINT ADJACENT
TO RPEAIR FOR INSPECTION OF THE INSTALLED REPAIR
USING A BOROSCOPE. ENSURE ADHESIVE PROVIDES
SUPPORT FROM PRECAST CONCRETE BACK-UP WALL TO THE
BACKSIDE OF THE STONE PANEL. A/E TO OBSERVE MOCK-UP
112"
3
4"
AT FIRST REPAIR LOCATION 2" TYP.

VARIES
PATCH FACE OF THE STONE PANEL WITH JAHN M160,
GRANITE REPAIR MORTAR, OR APPROVED EQUAL.
COLOR TO BE SELECTED BY OWNER EXISTING THIN STONE, GRANITE, OR
MARBLE PANEL, TYP. EXISTING THIN STONE, GRANITE, OR MARBLE
PANEL, TYP. - THICKNESS VARIES BY STONE
INSTALL A NEW 1 4" THICK CLOSED-CELL FOAM CAP TYPE:
OVER THE FRONT OF THE ANCHOR EXISTING CAVITY - GRANITE/MARBLE: 2"
- SANDSTONE: 1"
E EXISTING CONCRETE BACK-UP E
IF CRACK PRESENT, NOTIFY A/E FOR ADDITIONAL WALL BACKING MATERIAL AS
REPAIR DETAILS NECESSARY NEW NON-SHRINKING REPAIR
MATERIAL TO MATCH EXISTING STONE
MIN. 3/8" DIA. STAINLESS STEEL PREFINISHED PANEL
REPAIRS TO THE SPALLED AREA OF STONE PANEL AS PANEL ANCHOR. ANCHOR MAY BE EPOXY SET

VARIES
INDICATED IN DETAILS 1, 2, OR 3/R500.05. MINIMUM OR MECHANICALLY SET INTO BACK-UP
DEPTH OF REPAIR TO BE 116" CONCRETE. IF EPOXY SET, EMBED ANCHOR
MIN. 4 INCHES INTO BACK-UP. PLACE
EXISTING SEALANT IN JOINT TO BE REMOVED AND ANCHORS AS NOTED IN DEDUCTIVE
REPLACED ALTERNATE - IF EPOXY SET THREADED ROD IS CONTRACTOR TO CLEAN AND PREPARE
EXISTING PRECAST
USED, MATCH ROD LENGTH WITH DEPTH OF STONE SURFACES AT BUG HOLE IN
CONCRETE BACK-UP WALL
DRILLED HOLE SO THAT NO MORE THAN 18" OF ACCORDANCE WITH REPAIR MATERIAL
EXISTING KERF FOR STONE ANCHORAGE, TYP. ROD EXTENDS ABOVE NUT MANUFACTURER'S SPECIFICATIONS AND
SPECIFICATION SECTION 04 01 40.91
EXISTING STONE PANEL ANCHORAGE

EXISTING PRECAST CONCRETE BACK-UP WALL

Project

D D
Grady Memorial Hospital
Facade Rehabilitation - Project
No. F2016008
TYPICAL STONE PANEL SPALL REPAIR - SECTION SUPPLEMENTAL STONE ANCHOR SECTION TYPICAL BUG HOLE REPAIR SECTION 80 Jesse Hill Jr. Dr., SE
4 SCALE: 6" = 1'-0" 5 SCALE: 3" = 1'-0" 6 SCALE: 3" = 1'-0"
Atlanta, Georgia 30303

Client

C C
Grady Memorial Hospital
EXISTING CONCRETE BACK-UP WALL VARIES
EXISTING WALL CAVITY
80 Jesse Hill Jr. Dr., SE
EXISTING STONE ANCHOR TO
Atlanta, Georgia 30303
REMAIN EXISTING STONE MASONRY

EXISTING THIN STONE, GRANITE, OR


MARBLE PANEL, TYP. 3
4" MIN.
1
4" MIN.
VARIES

NEW BACKER ROD AND SEALANT


V.I.F.
CLEAN JOINT BEFORE INSTALLING
NEW BACKER ROD AND SEALANT
EXISTING BELOW-GRADE WATERPROOFING
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without

EXISTING MORTAR JOINT GROUND


permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

MEMBRANE TO REMAIN
TO A DEPTH OF 3 4". WHERE EXISTING
B MORTAR IS MISSING OR UNSOUND B
BEYOND 3 4", REPOINT TO THE DEPTH
SHOWN Mark Date Description
VARIES

0 1/2" 1" 2"


NOTE:
CONFIRM TYPICAL LOCATIONS OF
EXISITNG ANCHORS AND DOWELS PRIOR THIS SHEET PLOTS FULL SIZE
AT 30x42 (INCHES)
TO REMOVING EXISTING MORTAR. DO NOT
DAMAGE EXISTING STONE ANCHORS OR
DOWELS DURING REMOVAL OF MORTAR
Project No. 2016.1879

Date 3/6/17
EXISTING GRADE OR MECHANICAL GRATE -
EXCAVATE UP TO 12" OR REMOVE AND Drawn WL, KM
RESET GRATE AS NECESSARY. RESTORE
FINISHED GRADE TO EXISTING CONDITION Checked LC

Scale As Noted
STONE PANEL BASE-OF-WALL DETAIL STONE PANEL SEALANT REPAIR
7 8
A
SCALE: 3" = 1'-0" SCALE: 6" = 1'-0"
A Stone Masonry Repair
Details
Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R500.05
1 2 3 4 5 6 7 8 9 10

Masonry Repairs.dwg
Plotted: 3/20/2017 11:33 AM by Reynolds, Nathan File Name: p:\2016\2016.1xxx\2016.1879.0 - grady facade construction document (blc)\Drawings\Sheets\R500.06 Brick

ENGINEERS
ARCHITECTS
MATERIALS SCIENTISTS

H H
Wiss, Janney, Elstner Associates, Inc.
2915 Premiere Parkway, Suite 100
Duluth, Georgia 30097
B B
770.923.9822 tel | 770.232.9044 fax
www.wje.com

B
CLEAN, PRIME, AND PAINT MISCELLANEOUS STEEL
VENTS PIPES, ATTACHED STRUCTURES, AND SIMILAR

H
T H ELEMENTS FOUND ON ROOF AREAS THROUGHOUT
SEALANT CHART D

T
THE PROPERTY WITH AN APPROVED COATING - DO
B NOT PAINT GALVANIZED ELEMENTS, TYP.
B
W D
Y

G
T
1/4 IN. 1/4 IN.
L

IN
H
N

W
B

1/4 IN. TO 1/2 IN. 1/4 IN.

D
T
O

D
B 1/2 IN. TO 1 IN. W/2

BI
G
B = BOND LINE - MIN. 3/8" ON CONCRETE, STUCCO, OR MASONRY
GREATER THAN 1 IN. W/2 G

SE

R
- MIN. 1/4" ON METAL OR GLASS
T = SEALANT THICKNESS - MIN. 1/8" TO 3/8" FOR SILICONE SEALANTS
O

FO
- MIN. 1/4" TO 1/2" FOR URETHANE SEALANTS
GENERAL SEALANT BEAD PROFILE - PROVIDE AN "HOURGLASS" PROFILE WHERE POSSIBLE (B>T)
P
- PROVIDE MIN. 2:1 LENGTH TO THICKNESS RATIO (H:T)
Consultants
R
P U

TYPICAL SEALANT PROFILES TYPICAL SEALANT CHART ROOF ELEMENTS COATING DETAIL
1 SCALE: 1' = 1'-0" 2 SCALE: 1' = 1'-0" 3 SCALE: 1 1/2" = 1'-0"

F F

E E

Project

D D
Grady Memorial Hospital
Facade Rehabilitation - Project
No. F2016008
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303

Client

C C
Grady Memorial Hospital
80 Jesse Hill Jr. Dr., SE
Atlanta, Georgia 30303
Copyright 2016. All rights reserved. No part of this document may be reproduced in any form or by any means without
permission from Wiss, Janney, Elstner Associates, Inc. (WJE). WJE disclaims any responsibility for its unauthorized use.

B B

Mark Date Description


0 1/2" 1" 2"

THIS SHEET PLOTS FULL SIZE


AT 30x42 (INCHES)

Project No. 2016.1879

Date 3/6/17

Drawn WL, KM

Checked LC

Scale As Noted

A A
Typical Repair Details

Sheet Title

1 2 3 4 5 6 7 8 9 10
Sheet No. R500.06

You might also like