1. GENERAL

1.1 Document Purpose

This document provides installation information for the West-


ell UCIM-08C 8-Position Universal Customer Interface
Module (UCIM), shown in Figure 1.

1.2 Document Status

This document replaces the HyperEdge practice number


785-000148 and provides an editorial update.

1.3 Product Purpose

The UCIM-08C is used with the DTWA-528-08 8-position Digital


Terminal Wall-mounting Assembly (DTWA) as a replacement
for the standard Customer Interface Module (CIM), to provide
individual customer interfaces of either RJ48C, RJ48S, or RJ48H
(selectable) jacks.
Figure 1. Front View of UCIM-08C
1.4 Product Features

Features of the UCIM-08C are as follows: 3. Position the UCIM-08C either on the left or right side of the
mounting by sliding the UCIM card-edge connector into
S Selectable RJ48C/RJ48S/RJ48H jack configuration the 56-pin connector. Secure the UCIM into place via the
thumbscrews.
S Temperature hardened (-40_C to 65_C) 4. Re-position the cover back into place and secure it to the
mounting assembly. Note: If the UCIM is installed on the left
S Complies with UL 1950, Issue 2 of the NEC side, flip the top cover over and secure into place.

1.5 Installer Connections - INSPECTION NOTE -


Visually inspect the product for damages prior to installation. If
Pin-outs of the jacks used by the UCIM-08C are listed in the damaged in transit, immediately report the damage to the transporta-
table below. tion company and to Westell.

Lead RJ48C/X RJ48S 3. CUSTOMER & TECHNICAL SERVICES


(DS1/HDSL) (DDS/Analog)
To order units, or if technical or customer assistance is re-
T 5 1
quired, contact Westell by calling or using one of the following
R 4 2 options:
T1 2 7
Voice: (800) 377-8766
R1 1 8
email: global_support@westell.com
Typical of Circuits 1 through 8.

Table 1. UCIM-08C Pin-outs For additional information about Westell, visit the Westell
World Wide Web site at http://www.Westell.com.

2 INSTALLATION 4. WARRANTY & REPAIRS

The UCIM-08C can be mounted on either the right or left side 4.1 Warranty
of the Westell DTWA-528-08 mounting assembly.
Westell warrants this product to be free of defects at the time
of shipment. Westell also warrants this product to be fully func-
1. Lay the mounting assembly down on its backplate.
tional for the time period specified by the terms and conditions
2. Turn the thumbscrews, located on the right-hand side of the governing the sale of the product. Any attempt to repair or
mounting, counterclockwise and lift off the top cover of the modify the equipment by anyone other than an authorized
mounting assembly. Westell representative will void the warranty.

0801I1RA E Copyright 2008 Westell, Inc. All rights reserved. Page 1 of 2


Section UCI-M08-C00-301
030-300546

4.2 Repair and Return

Westell will repair or replace any defective Westell equipment Part # Description
without cost during the warranty period if the unit is defective UCIM08C 8-Position Universal Customer Interface Module with
for any reason other than abuse, improper use, or improper selectable interfaces of RJ48C/RJ48S/RJ48H.
installation. To return defective equipment, first request a Re- CLEI* Code: VAMYABBRAA. Barcode/ECI: 439593. CPR: 203428.
turn Material Authorization (RMA) number from Westell by *CLEI is a trademark of Telcordia Technologies.
calling or using one of the options shown below. Once an RMA Table 2. Ordering Information
number is obtained, return the defective unit (freight prepaid),
along with a brief problem description, to the address we will
provide to you when you contact us. Feature U.S. Metric
Voice: (630) 375-4211 Height 7.75 in. 19.7 cm
email: rgmdept@westell.com Width 6 in. 15.2 cm
Depth 0.75 in. 1.9 cm
Replacements will be shipped in the fastest manner consistent Weight (approx.) 13 oz. 5.9 g
with the urgency of the situation. Westell will continue to repair Operating Temp. -40° to 149°F -40° to 65°C
or replace faulty equipment beyond the warranty period for a
nominal charge. Contact Westell for details. Table 3. Physical Specifications