Operating Instruction for Weighing Meter K3NV MCI 70-N

The following symbols were used through out the chapter for easy setting of parameters.

- Mode Key - Press briefly the mode key single time.

1Sec - - Press the mode key for about 1 second.

- Shift Key - Press briefly the shift key single time.

- Up Key - Using the Up Key select the desired data.

- - Using the Up and Shift key select the desired data.

Esc - Escape Key - Press briefly the Esc key single time.

Reset - Reset / Teach - Press briefly the Reset/Teach key single time.
/ Teach

Reset
1Sec / Teach - - Press the Reset/Teach key for about 1 second.

Esc + - - Press both the Esc key and the Up Key.

Page1
Operating Instruction for Weighing Meter K3NV MCI 70-N

The following flowchart explains the setting procedure for the weighing meter.

Power On

Run Mode display The display shows the data

1Sec

SUSEt Setting Menu

SCALE Scale Menu

SEtUP Setup Menu

1Sec

In -t Input Range

Set the parameter as shown


bLC blc – 0 to 20mV input

FrE Frequency

Page2
Operating Instruction for Weighing Meter K3NV MCI 70-N

50 Power line Frequency

In -t Input Range

Esc

SEtUP
Setup Menu

Opt Option Menu

1Sec

AvG Average Processing

60008 Movement Average 8 times

StCnE Startup Compensation

Page3
Operating Instruction for Weighing Meter K3NV MCI 70-N

4
Power on delay – 4 Sec

HYS Hysteresis

x Agg – 5 ; Cem – 2 ; Adm – 0.05

C–oUT Comparitive Output Pattern

nonAL Standard Output

LSEt.H

LSEt.L

Page4
Operating Instruction for Weighing Meter K3NV MCI 70-N

AvG

Esc

oPt Option Menu

tESt

SuSEt Setting value Menu

Starting of Calibration
- Ensure that the weigher
is empty. SCALE Scaling Menu

1 Sec

InP.2

Page5
Operating Instruction for Weighing Meter K3NV MCI 70-N

dSP.2

InP.1 Input Value 1

Reset
1Sec / Teach

The display shows the


X.XXXX input voltage in mV

Reset
/ Teach

InP.1

dsP.1 Display value 1

0
Set value ‘0’

dEC-P Decimal position

Page6
Operating Instruction for Weighing Meter K3NV MCI 70-N

X.X.X.X.X Decimal point position


Agg – Nil ; Cem – Nil ; Adm – x.xxx

InP.2

Esc

SCALE

SEtUP

oPt Option Menu

1Sec

AvG

StCnE

HYS

Page7
Operating Instruction for Weighing Meter K3NV MCI 70-N

C–oUt

LSEt.H

LSEt.L Linear Output Range - Low

Reset
1 Sec / Teach

The display shows the value


0 corresponding to zero weight
on the weigher.
Reset
/ Teach

LSEt.L

Esc

oPt Option Menu

tESt

SuSEt

Page8
Operating Instruction for Weighing Meter K3NV MCI 70-N

Calibration for Max load G


- Ensure that the weigher
loaded with maximum
weight to be measured.
Agg – 1250Kg ; Cem – 400Kg SCALE
Adm – 6.000Kg
1 Sec

InP.2 Input Value 2

Reset
1 Sec
/ Teach

X.XXXX The display shows the


input voltage in mV
Reset
/ Teach

InP.2

dsP.2 Display value 2

Enter the value corresponding to


XXXX Maximum weigher value.
Agg – 1250 ; Cem – 400 ; Adm – 6.000

InP.1

Esc

Page9
Operating Instruction for Weighing Meter K3NV MCI 70-N

SCALE

SEtUP

oPt

1Sec

AvG

StCnE

HYS

C–oUt

Page10
Operating Instruction for Weighing Meter K3NV MCI 70-N

LSEt.H Linear Output Range - High

Reset
1 Sec / Teach

The display shows the value


xxxx corresponding to Max. Weight
on the weigher.
Reset Agg-1250; Cem- 400; Adm- 6.000
/ Teach

LSEt.H

Esc

oPt

tESt

SuSEt
Setting Value Menu

1Sec

S u .H H Weigher Maximum value

Page11
Operating Instruction for Weighing Meter K3NV MCI 70-N

Agg - 1250 ; Cem - 400 ; Adm – 6.000


XXXX

Su.H Weigher Pre-Maximum value

XXXX Agg - 1230 ; Cem - 395 ; Adm – 5.950

Su.L Weigher Empty value

XXXX Agg - 5 ; Cem - 2 ; Adm - 0.005

Su.LL

XXXX Agg : -5 ; Cem : -2 ; Adm : -0.005

Page12
Operating Instruction for Weighing Meter K3NV MCI 70-N

Su.HH

Esc

SuSEt

Esc

Run Mode The Display shows weigher value

Esc +

Prot Protect Menu

1 Sec

ALL All Key Protect

uPoFF Protect off

SuSEt Setting value change Prohibit

Page13
Operating Instruction for Weighing Meter K3NV MCI 70-N

uPoN Protect ON

ZEro Zero Setting Prohibit

uPon Protect ON

nn.rSt Maximum and Minimum value Prohibit

uPon
Protect ON

SECr Security

1 Setup Menu Prohibited

Page14
Operating Instruction for Weighing Meter K3NV MCI 70-N

ALL

Esc

Run Mode End of Parameter Setting