The proposed Three – Storey Airport Hotel has an estimated vicinity area of 550
square meters including the building and landscapes, 35m x 5.5m parking space. It
will provide a wide and comfortable space for the customers. It is located near the
The site has a bearing capacity of 19 Kpa. The site belongs to the San Jose, Area
with total land area of 48.56 sq. km. and a population density of 1300/sq. km.
Barangay San Fernando is located N 40° 44’ 30.822” and W 73° 59’ 21.508”.
the capital town of Antique. The barangay is divided into 4 puroks. It is a place by the
sea and it has many knowned beach resorts that is regularly visited by the locals and
even visitors from nearby towns. It is approximately 3.5km from the Municipal Hall
The proposed project will demolish existing concrete structures only. The area for
There will be an excavation for wall footing, column footing and septic tank only.
There will be slab on fill in the main floor, CR, ramp and porch.
Concrete work includes column footing, wall footing, column, beam, slab on fill
II. A. 4. C Column
Beam 3 (426.33m x 0.20m x0. 40m) are all the same on the second
Slab on fill is composed of the main floor, cr, porch and ramp (1st
and second floor). On the first floor, the main floor has a dimension
38.2m x 0.3m), and ramp (3.6m x 1.5m x 0.3 m). On the second
floor, the main floor has a dimension of 7.5m x 4.5m x0.125m (10
0.125m (10 units)). On the third floor, the main floor has a
the roof deck has a dimension of 16m x 4.5m x 0.125m (2 units) and
II. A. 4. G Stairs
Stair has a total width of 1.95 meters. It has 20 steps with a rise of
II. A. 5. C Column
In this item of work, the main bar to be used is 20mm ᴓ and 10mm
II. A. 5. D Beam
In this item of work, the main bar to be used is 12mmᴓ and 12mmᴓ.
In this item of work, the main bar to be used is 10mmᴓ and 10mmᴓ.
II. A. 5. G Stairs
In this item of work, the main bar to be used is 12mmᴓ and 10mmᴓ.
II. A. 6 Forms and Scaffolding
The materials to be used are (1/4" X 4' x 8') Marine Plywood, 2" x 3" x 14" Good
Lumber (rough).
In this item of work, the area to be plastered on all floors is 1,875 m2 and the
The total area to be covered by ceramic unglazed (24” x 24”) in first floor is 460.06
m2. The total area to be covered by ceramic unglazed tile (16” x 16”) in rooms and
balconies is 634.88 m2. The total area to be covered by ceramic unglazed tile (20”
x 20”) in second and third floor hallway is 139.35 m2. The total area to be covered
by ceramic unglazed tile (8” x 8”) and (8” x 8”) glazed wall tile in toilet and
ceramic unglazed tile (24” x 24”) and (8” x 8”) glazed wall tile in comfort room is
For concreting, the bottom slab is 6.0m x 2.7m x0.15m and top slab is 6.0m x 2.7m
x 0.1m.
II. A. 11 Window
The window to be used is fixed glass window (1.5m x 1.2m- 4 sets) and (1.275m x
II. A. 12 Doors
Doors to be used are the following; (2m x 2.1m- 2 sets, D1) glass double door, ;
(1.6m x 2.1m- 3 sets, D2) double door, (.8m x 2.1m- 20 sets, D3) sliding glass door,
(.8m x 2.1m- 26 sets, D4) panel door, (.6m x 2.1m- 24 sets, D5) hollow core flush
door, (.8m x 2.1m- 1 set, D6) half glass panel door, (.6m x 1.8m- 6 sets, D7)
aluminum door.
II. A. 13 Ceiling
The materials to be used are shown in the detailed estimates of this project proposal.
Paint should be applied on walls and ceiling. The areas to be painted are: 1875 m2
In this item of work, there are (52 pcs.) Junction box, (50 pcs.) Utility box, (978
pcs.) Electrical Conduit PVC 20 mm, (4 pcs.) Panel Box, Flush Type, 16 Branches,
Wire, Stranded, (69 pcs.) Duplex C.O Tampered Proof, (4 pcs.) 3-Gang Switch with
Plate Cover, (12 pcs.) 2- Gang Switch with Plate Cover, (29 pcs.) 1-Gang Switch
with Plate Cover, (70 pcs.) C-Flourescent Lamp, (7 pcs.) Flourescent Lamp, (80
pcs.) Pin Light, (52 sets) Circuit Breaker, 20 AT, 2P, (52 pcs.) Lighting Outlet, (21
pcs.) 1 Hp, Air-Con., (23 sets) Aircon Outlet, (20 rolls) Electrical Tape, Big.
II. B Benefits
The success of the 3 storey hotel will not only be beneficial for travellers,
but also to local people nearby because there will be an increase of visitors that
convenient stores, laundry shops, etc., which will be an opportunity for residents
to earn money. Neighbouring places can also open up resorts because the place is
located near the beach. Improvement on local tourism and small industries can be
expected out of it because it can draw a lot of foreign and domestic visitors. The
proposed 3-storey hotel will provide the guests, tourists, passengers, and the
locals a temporary place to stay, provide food services and cater the personal
objective or goal.
There are a number of different types of constraint that can affect construction
projects.
the early stages of a project, so that awareness of them and their potential impact can be
managed. This includes understanding the dynamics of the project and how different
constraints interrelate, as well as being clear about any potential risks and who is
Design constraints are factors that limit the range of potential design
next can begin; therefore each task acts as a constraint on the next
task.
performance.
construction system may not be the best option for achieving the
project goal and quality. It will affect the proceeding of the project.
Legal constraints refer to the many regulations that the activities and
and so on.
However, where there are delays that are not the contractor's fault,
Preservation of ecology.
original plans.
Improper measuring of the aggregates during the mixing operation, this is common
practice when the work is on its momentum where laborers fail to observe the right
The cement and fine aggregates for grouting concrete joints are mostly overlooked
The pure cement powder used by mason in plastering operations to prevent the
construction management.
Breakage of concrete hollow blocks and other fragile materials such as ceramic
tiles, light bulbs, and jalousie during installation are common on the project