TEST REPORT FOR MOISTURE CONTENT OF SAND

Project name : Tested for :


Moisture content
Lab Reference :
Date of sampling: Date of test :

Test No. 1 2 3 4 5

Container No.

Wt. Of wet sand taken (Sw)

Wt. Of dry sand in pan (Sd)

Wt. Of water (W=Sw-Sd)

Moisture content
= 100* W/Sd

Remarks:

Test result: OK / NOT OK


Checked by: CONTRACTOR CLIENT
Name:
Signature:
TEST REPORT FOR SILT CONTENT OF FINE AGGREGATE

Project name :
Tested for : silt content
Source :
Lab Reference : Store entry no:
Date of sampling: Date of test :

Sl. No. Descriptions Trail No. Remarks

1 Volume of the sand


(v1)
2 Volume of silt (v2)

3 Silt content in %.
V2/V1 X 100

Comments if any
Checked by: CONTRACTOR CLIENT
Name:
Signature:
TEST REPORT FOR SIEVE ANALYSIS OF FINE AGGREGATE

Project name :
Tested for : Sieve analysis
Source :
Lab Reference : Store entry no:
Date of sampling: Date of test :
Technical ref. : IS 383 – 1970 (RA-2002)

Sieve Wt. Cum.wt. Cum. % Cum. % Percentage passing As per


retained retained wt. passing IS 383 for
retained Zone 1 Zone 2 Zone 3 Zone 4
10mm 100 100 100 100

4.75 90-100 90-100 90-100 95-100


mm
2.36 60-95 75-100 85-100 95-100
mm
1.18 30-70 55-90 75-100 90-100
mm
600 15-34 35-59 60-79 80-100
microns
300 5-20 8-30 12-40 15-50
microns
150 0-10 0-10 0-10 0-15
microns
Pan

Remarks:

Test result: OK / NOT OK


Checked by: CONTRACTOR CLIENT
Name:
Signature:
TEST REPORT FOR SIEVE ANALYSIS OF COARSE AGGREGATE,

Project name : Tested for :


Sieve analysis,
Lab Reference: Store entry :
Date of sampling: Date of test:
Technical ref. : IS 383 – 1970 (RA-2002), IS 2386 – 1970 (RA.2002)

Sieve Wt. Cumu wt. Cumu. Cumu. % Requirement Requirement


no. retained retained % wt. passing 12.5mm 20mm
retained Graded Single Graded Single
size size
------ ------ 100 100
40mm

100 100 95-100 85-100


20mm

90-100 85-100 ------ -------


12.5mm

40-85 0- 45 25-55 0-20


10mm

0-10 0-10 0-10 0-5


4.75mm

Pan
Remarks:

Test result: OK / NOT OK


Checked by: CONTRACTOR CLIENT
Name:
Signature:
TEST REPORT FOR BRICKS
Project name : Tested for : Compressive
strength
& water absorption
Lab Reference: ` Store entry :
Date of sampling:
Date of test:
Technical ref. :
1. Physical Properties

Dimensional Conformance
Sounding
Colour
Obliqueness
Remarks
2. Compressive strength

Sl. C/S Area Maximum Compressive Requirement Remarks


No. (mm2) Load (N) Strength as per
LXB N per mm2 specification
1
2
3

3. Water absorption

Sl. Wt. of oven Wt. of wet % of water Requirement Remarks


No. dried brick brick (kg) absorption
(kg)
1 not more than
2 20% by mass
3

Test result: OK / NOT OK


Checked by: CONTRACTOR CLIENT
Name:
Signature: