General Refrigeration Example below of 2 low side leaks. In both cases, high side
Rules pressure was very high (200-250 PSI) and amp draw was
1. Under normal conditions, low side and high side also high (around an amp).
pressures follow one another. Reason: after defrost the compressor sucked moisture into
--If high side pressure goes up, low side pressure follows the system.
--If low side pressure goes up, high side pressure follows
MOISTURE DOES NOT BELONG
2. Heat load has greatest effect on low side pressure IN A SEALED SYSTEM!!!
-- As heat load increases, both low and high side pressures
go up
-- As heat load is decreased, pressures go down
_______
_______
Normal Condition
_______
Low Side Leak- Refrigerant still left in the system
Restriction
_______
_______
Inefficient Compressor
_______