You are on page 1of 5
> C7. SES a Vy leceu\.slsss went OF Ajm Municipality & Planning Department BUILDING MATERIALS LABORATORY [REPORT ON COMPRESSIVE STRENGTH OF CONCRETE CORE CLIENT/ OWNER ‘YOUSEF MOHAMMED ABDULLA MOHAMMED REPORTNO. —, RSPCI8-2 conTRAcToR NOOR AL MANAMA BLDG.CONT, DATEREPORTED Il-Jan-18 CONSULTANT SMART ARCHLENG.CONS. REQUESTNO. —; QSPCIB-2 BUILDING PERMIT NO. -BLDG-00-17-0000690 SAMPLE NO. SSPCIB-L PROJECT NAME, PRO.G+4 BLDG. CLIENTREE.NO. ROJECT LOCATION 517-NUAIMEYA.2-CITY CENTER-AJMAN, INVOICENO. ——, 3182 PAGE oft SAMPLE DETAILS: [SAMPLE DESCRIPTION CORE CASTING DATE NG CONCRETE SUPPLIER P SAMPLED BY 2 BML REPRESENT, [CONCRETE GRADE (N/mm) we DRILLING DATE Sans \ceMENT TYPE CONTENT Ne RECEIVING DATE & TIM; 7-Janel8 MAX AGG. SIZE 20mm SAMPLES BROUGHT IN}; BML REPRESENT Iso. OF SAMPLES a SURFACE MOIST. CONDI; DRY POURCE OF CONCRETE CORE: PILE SOAKING PERIOD 8s EST DETAILS: REFARATION METHOD USED Cuing, Grinding & Capping DATE TESTED 7 TosanTe [rest METHOD DBS :1861 :PART 120-1983, TESTED BY AZM/SHD EST METHOD VARIATION Nil REPORTED BY ABZ, Tess of sample (ys) Be pe 7 one 4 5 6 ore Reference i Cy PB Drilig location PLE PUBS PES dition of specimen ‘NORMAL NORMAL NORMAT rection of dling VERTICAL VERTICAL VERTICAL 3 93 3 ia 1 120 7, is 26 SATURATED SATURATED SATURATED cmcrete demity (Kel) a0 2420 2350 load at fallre (KN) 1650 200 130 ompresive strength (Mmm) 270 30 255 ibe regth (am) 280 350 270 rent (Fk) (M2) 30 au RO etbod ead preparation SULFUR COMP CAPPING SULFUR COMP CAPPING SULFUR COMP.CAPPING of falture SATISFACTORY SATISFACTORY SATISFACTORY REMARKS : This report shall nt be reproduced except ia ful, without the approval ofthe laboratory. = Please see attached documents of core description. Seng (ok) denotes characteristic sent based on conection factor 0. (BS 60872010 and use as pidance Strength (3) ss for srcra adequacy based on BS 60892010 GENERAL DESCRIPTION OF THE DRILLED CORES ual Observations: Sample No. 004 005 006 Core Reference Pile-1 Pile-2 Pile-3 Length / Diameter 155/93 190/93 200/93 Conerete Compaction Good Good Good Distribution of Segregated and noticed Uniform Segregated Material ‘cement paste at the middle ofcore Classification of Voids SM s Excess Voidage (%) os os os Reinforcement Details Nil Nil Nil 20 mm down crushed |20 mm down crushed aggregates aggregates Aggregate Description *S. Small (05 min to 3 mm), M- Medium 3 mm to 6 mm). Attachment to Report No, RSPC18-002-(Page 12) Large (6 mim), HC Honeycombing . . \\= Sac SESS ales We S ORME FAA Government Of Ajman Municipality & Planning Departmen BUILDING MATERIALS LABORATORY REPORT ON COMPRESSIVE STRENGTH OF CONCRETE CORE CLIENT OWNER YOUSEF MOHAMMED ABDULLA MOHAMMED REPORT NO. ; RSPCIB-2 ‘coNTRACTOR NOOR AL MANAMA BLDG CONT. DATEREPORTED + IlaneI8 CONSULTANT SMART ARCHLENG.CONS, REQUESTNO. —; QSPCIB2 BUILDING PERMIT NO. P O1-BLDG-100-17-2000680 SAMPLENO.: SSPCIBA-8 PROJECT NAME F PRO.G*4 BLDG. CLIENTREF.NO. | - PROJECT LOCATION SIT-NUAIMEYA2-CITY CENTER-AIMAN INVOICENO. 3182 PAGE 2of? [SAMPLEDETARS ISANIPLE DESCRIPTION CORE ‘CASTING DATE NG IcoNcRETESUPPLIER : SAMPLED BY BML REPRESENT ICONCRETEGRADE (Wim NP DRILLING Dare San8 IcusterT¥PE/CONTENT.—: NP RECEIVING DATE.& TIM: 7-an-I8 MAXAGG. SIZE 20mm SAMPLES BROUGHTINY : BML REPRESENT ho. oF sampes 2 SURFACE MOIST. COND! : DRY “OURCEOF CONCRETE CORE: PILE SOAKINGPERIOD atin [reST DETAILS: PREPARATION METHOD USED DATE TESTED 7 ToaTs [rest merHop TESTED By AZMSHD [nest METHOD VARIATION REPORTED BY = ABZ Details stn % x umple No. 7 8 rages aa ars aaa a Sova Sr a ame aaa 7 im = 7 i =a ee oe Concrete density (Kg/m") 2240, 2420 Sarre i i Fei mgh hea 7 7 [Pstimate cube strength (Nimam’) 28.0 35.0 =a = a Seer Taco | Saco = TATE AACR REMARKS: This report shall not be reproduced except in fll, without the approval ofthe laboratory. ~ Please see attached documents of core description, ‘Surength (fe) denotes characteristic strength based on correction factor 0.85 (BS 6089-2010) and use es guidance ‘Strength (Fk) is we for structural adequacy based on BS 6089:2010,

You might also like