You are on page 1of 12

ComAp

Fault Name Suffix FMI


Code
Actuator0 Fls 757 3
Actuator1 Fls 758 3
Actuator2 Fls 759 3
Actuator0 Fls 757 4
Actuator1 Fls 758 4
Actuator2 Fls 759 4
BattVoltErr Wrn 167 1
BattVoltErr Wrn 168 1
BattSensErr Fls 169 3
BattSensErr Fls 169 4
Can0Err Fls 511 14
Can1Err Fls 512 14
Can2Err Fls 513 14
Can0Err Fls 511 12
Can1Err Fls 512 12
Can2Err Fls 513 12
CoolantTemp Wrn 213 1

CoolTempSens Fls 215 3

CoolTempSens Fls 215 4

PCSComGB Fls 524 9


ComMSErrA Wrn 611 1
ComMSErrT Wrn 612 1
RdntMode Wrn 613 1
T15Err Fls 725 5
PCSComSpd Fls 548 9
Cy146SpiCom Fls 573 9
CY320SpiCom Fls 812 9
StopBtnErr Fls 813 2
MSIDpin Wrn 814 1
EcuEepromErr Fls 772 11
EcuEepromErr Fls 772 14
EcuEepromErr Fls 772 12
InjCutOff Wrn 721 1

OvrSpeed Wrn 769 1


AmbiantPres Fls 142 2
AmbPresSens Fls 143 3
AmbPresSens Fls 143 4
CamshaftSig Fls 791 2
CamshaftSig Fls 791 12
CamshaftSig Fls 791 14
CrkShaftSig Fls 793 2
CrkShaftSig Fls 793 12
FuelFltClog Wrn 712 1
FlowLim1 Wrn 651 1
FlowLim8 Wrn 652 1
FlowLim4 Wrn 662 1
FlowLim12 Wrn 663 1
FlowLim5 Wrn 653 1
FlowLim10 Wrn 654 1
FlowLim3 Wrn 655 1
FlowLim7 Wrn 656 1
FlowLim6 Wrn 657 1
FlowLim11 Wrn 658 1
FlowLim2 Wrn 659 1
FlowLim9 Wrn 661 1
FuelPres Wrn 135 1
FuelPres Wrn 136 1
FuelPresSens Fls 711 3
FuelPresSens Fls 711 4
FuelTemp Wrn 181 1
FuelTempSens Fls 183 3
FuelTempSens Fls 183 4
InjBank1 Wrn 895 1
InjBank2 Wrn 896 1
InjBank3 Wrn 897 1
InjChip1 Wrn 826 1
InjChip2 Wrn 827 1
Injector1 Fls 413 5
Injector8 Fls 414 5
Injector4 Fls 424 5
Injector12 Fls 425 5
Injector5 Fls 415 5
Injector10 Fls 416 5
Injector3 Fls 417 5
Injector7 Fls 418 5
Injector6 Fls 419 5
Injector11 Fls 421 5
Injector2 Fls 422 5
Injector9 Fls 423 5
Injector1 Fls 413 3
Injector8 Fls 414 3
Injector4 Fls 424 3
Injector12 Fls 425 3
Injector5 Fls 415 3
Injector10 Fls 416 3
Injector3 Fls 417 3
Injector7 Fls 418 3
Injector6 Fls 419 3
Injector11 Fls 421 3
Injector2 Fls 422 3
Injector9 Fls 423 3
PTOSwitch Fls 127 3
MeteringUnit Fls 442 5
MeteringUnit Fls 442 6
MeteringUnit Fls 441 3
MeteringUnit Fls 441 4
MeteringUnit Fls 442 3
MeteringUnit Fls 442 4
PTOSwitch Fls 127 4
EcuADC Wrn 831 1
EcuADC Wrn 832 1
InternErr1 Wrn 834 1
InternErr2 Wrn 835 1
EcuRomErr Wrn 836 1
InternErr3 Wrn 633 1
InternErr3 Wrn 634 1
InternErr3 Wrn 635 1
InternErr3 Wrn 636 1
InternErr3 Wrn 637 1
InternErr3 Wrn 638 1
InternErr3 Wrn 639 1
InternErr3 Wrn 641 1
InternErr3 Wrn 642 1
InternErr3 Wrn 643 1
InjectETMax Wrn 48 1
InjectETMax Wrn 49 1
MainRlyOpen Wrn 752 1
MainRlyStk Wrn 751 1
PTOSwitch Fls 127 5
HWPSShutOff Wrn 845 1
HWPSShutOff Wrn 846 1
HWPSShutOff Wrn 847 1
HWPSShutOff Wrn 848 1
OilPressure Wrn 93 1
OilPressure Wrn 94 1
OilPresSens Fls 112 3
OilPresSens Fls 112 4
OilTemp Wrn 177 1
OilTempSens Fls 176 3
OilTempSens Fls 176 4
EHIDpin Wrn 824 1
EHIDpin Wrn 824 1
IntakePres Wrn 113 1
IntakePSens Fls 117 3
IntakePSens Fls 117 4
PrReliefVlv Wrn 912 1
PRVOpened Wrn 918 1
PrReliefVlv Wrn 917 1
R2S2MSCErr Wrn 853 1
RailPrMgmt0 Wrn 854 1
RailPrMgmt1 Wrn 855 1
RailPrMgmt2 Wrn 856 1
RailPrMgmt4 Wrn 858 1
RailPrMgmt5 Wrn 859 1
RailPrMgmt8 Wrn 863 1
RailPresSens Fls 156 5
RailPresSens Fls 156 3
RailPresSens Fls 156 4
PRVModeErr Wrn 879 1
RailPSensWi Fls 157 3
RailPSensWi Fls 157 4
PTOSwitch Fls 127 6
SpeedPot Fls 91 3
SpeedWire Fls 29 3
SpeedPot Fls 91 4
SpeedWire Fls 29 4
SensSupply1 Wrn 741 1
SensSupply2 Wrn 742 1
SensSupply3 Wrn 743 1
DatasetErr Wrn 591 1
DatasetErr Wrn 592 1
SpeedSelHi Fls 891 3
SpeedSelHi Fls 891 4
ECUWarnLamp Fls 715 5
ECUWarnLamp Fls 715 3
ECUWarnLamp Fls 715 4
Reset Wrn 717 1
EcuTemp Wrn 34 1
EcuTemp Wrn 35 1
EcuTemp Fls 36 2
IntakeTemp Wrn 122 1
IntakeTSens Fls 125 3
IntakeTSens Fls 125 4
EcuOnLmp Fls 889 5
EcuOnLmp Fls 889 3
EcuOnLmp Fls 889 4
SpeedSelLo Fls 893 5
SpeedSelLo Fls 893 3
SpeedSelLo Fls 893 4
Active Active
Description Active L6 Lamp ON
Master Slave
Short circuit to battery error at acuator relay 0 Y Y Y Y
Short circuit to battery error at acuator relay 1 Y N N Y
Short circuit to battery error at acuator relay 2 Y N Y Y
Short circuit to minus error at acuator relay 0 Y Y Y Y
Short circuit to minus error at acuator relay 1 Y N N Y
Short circuit to minus error at acuator relay 2 Y N Y Y
High Battery Voltage indication Y Y Y Y
Low Battery voltage indication Y Y Y Y
SRC high for battery voltage sensor Y Y Y Y
SRC low for battery voltage sensor Y Y Y Y
Open Bus CAN A Y Y Y Y
Open Bus CAN B Y Y Y Y
Open Bus CAN C Y Y N Y
BusOff (short-circuit) error CAN A Y Y Y Y
BusOff (short-circuit) error CAN B Y Y Y Y
BusOff (short-circuit) error CAN C Y Y N Y
Coolant temperature too high Y Y Y Y
SRC High for Engine coolant temperature sensor
Y Y Y Y
(down stream) (short-circuit to battery or open circuit)

SRC low for Engine coolant temperature sensor (down


Y Y Y Y
stream) (short circuit to gnd)
Timeout communication error with CAN lever (GB
Y N Y Y
control)
Angle synchronous communication error on CAN C Y Y N Y
Time synchronous communication error on CAN C Y Y N Y
ECU in redundant mode Y Y N Y
T15 different between Master and slave ECUs Y Y N Y
Timeout communication error with CAN lever (Speed
Y N Y Y
control)
Reported SPI and COM-Errors of a Cy146 Y Y Y Y
SPI/COM-Errors of the Cy320 Y Y Y Y
Stop signal error Y Y Y Y
M/S Identification pin error Y Y Y Y
EEP Read Error based on the error for more blocks Y Y Y Y
EEP Read Error based on the error for more blocks Y Y Y Y
EEP Write Error based on the error for one block Y Y Y Y
Injection cut off demand (ICO) for shut off coordinator Y Y Y Y

Overspeed detection in component engine protection Y Y Y Y


Low Environment pressure Y Y Y Y
Sensor signal error High for Environment Pressure Y Y Y Y
Sensor signal error low for Environment Pressure Y Y Y Y
DFC for camshaft signal diagnose - disturbed signal Y Y Y Y
DFC for camshaft signal diagnose - no signal Y Y Y Y
DFC for camshaft offset angle exceeded Y Y Y Y
DFC for crankshaft signal diagnose - disturbed signal Y Y Y Y
DFC for crankshaft signal diagnose - no signal Y Y Y Y
Signal error for fuel filter clog detection Y N Y Y
Flow limiter closed in cyl. 1 N Y Y Y
Flow limiter closed in cyl. 8 Y N Y Y
Flow limiter closed in cyl. 4 N Y N Y
Flow limiter closed in cyl. 12 Y N N Y
Flow limiter closed in cyl. 5 N Y Y Y
Flow limiter closed in cyl. 10 Y N Y Y
Flow limiter closed in cyl. 3 N Y Y Y
Flow limiter closed in cyl. 7 Y N Y Y
Flow limiter closed in cyl. 6 N Y N Y
Flow limiter closed in cyl. 11 Y N N Y
Flow limiter closed in cyl. 2 N Y N Y
Flow limiter closed in cyl. 9 Y N N Y
Fuel pressure in low pressure circuit too high Y N Y Y
Fuel pressure in low pressure circuit too low Y N Y Y
Sensor signal error high for fuel pressure Y N Y Y
Sensor signal error low for fuel Pressure Y N Y Y
Fuel temperature too high Y N Y Y
Sensor signal error high temperature sensor Y N Y Y
SRC low for fuel temperature sensor Y N Y Y
Short circuit in injection bank 0 Y Y Y Y
Short circuit in injection bank 1 Y Y Y Y
Short circuit in injection bank 2 Y Y N Y
Chip error in the CY33x power stage component Y Y Y Y
Chip error in the CY33x power stage component Y Y Y Y
Open load error of injector 1 N Y Y Y
Open load error of injector 8 Y N Y Y
Open load error of injector 4 N Y N Y
Open load error of injector 12 Y N N Y
Open load error of injector 5 N Y Y Y
Open load error of injector 10 Y N Y Y
Open load error of injector 3 N Y Y Y
Open load error of injector 7 Y N Y Y
Open load error of injector 6 N Y N Y
Open load error of injector 11 Y N N Y
Open load error of injector 2 N Y N Y
Open load error of injector 9 Y N N Y
Short circuit in the injector 1 N Y Y Y
Short circuit in the injector 8 Y N Y Y
Short circuit in the injector 4 N Y N Y
Short circuit in the injector 12 Y N N Y
Short circuit in the injector 5 N Y Y Y
Short circuit in the injector 10 Y N Y Y
Short circuit in the injector 3 N Y Y Y
Short circuit in the injector 7 Y N Y Y
Short circuit in the injector 6 N Y N Y
Short circuit in the injector 11 Y N N Y
Short circuit in the injector 2 N Y N Y
Short circuit in the injector 9 Y N N Y
CAN signal error max for PTO switch Y N Y Y
open load of metering unit output Y Y Y Y
over teperature of device driver of metering unit Y Y Y Y
short circuit to battery in the high side of the MeUn Y Y Y Y
short circuit to ground in the high side of the MeUn Y Y Y Y
short circuit to battery of metering unit output Y Y Y Y
short circuit to ground of metering unit output Y Y Y Y
CAN signal error min for PTO switch Y N Y Y
NTP error in ADCmonitoring Y Y Y Y
ADC test error Y Y Y Y
Errors in internal query/response communication Y Y Y Y
Errors in internal SPI-communication Y Y Y Y
Multiple error while checking the complete ROM-
Y Y Y Y
memory
Internal synchronization error Y Y Y Y
DFC to set a torque limitation once an error is detected
Y Y Y Y
before MoCSOP’s error reaction is set
Wrong set response time Y Y Y Y
Too many SPI errors during MoCSOP execution. Y Y Y Y
Error in undervoltage monitoring Y Y Y Y
WDA is not working properly Y Y Y Y
OS timeout in the shut off path test. Failure setting the
Y Y Y Y
alarm task period.
Internal positive test failed Y Y Y Y
Timeout in the shutoff path test Y Y Y Y
Error in over voltage monitoring Y Y Y Y
Injector energizing time OverRun Y Y Y Y
Injector energizing time OverRun with cooling injection Y Y Y Y
Early opening defect of main relay Y Y Y Y
Main relay stuck error Y Y Y Y
CAN signal not plausible for PTO switch Y N Y Y
WDA active due to errors in query-/response
Y Y Y Y
communication
ABE active due to undervoltage detection Y Y Y Y
ABE active due to overvoltage detection Y Y Y Y
WDA/ABE active due to unknown reason Y Y Y Y
Oil pressure too high Y N Y Y
Oil pressure too low Y N Y Y
Sensor error high for oil pressure Y N Y Y
Sensor error low for Oil pressure sensor Y N Y Y
Oil temperature too high error Y N Y Y
Sensor error High for Oil Temperature Y N Y Y
Sensor error low for Oil Temperature Y N Y Y
Engine harness identification error N Y N Y
Engine harness identification error Y N Y Y
Intake pressure to high Y Y Y Y
Sensor error high for intake pressure sensor Y Y Y Y
Sensor error low for intake pressure sensor Y Y Y Y
pressure relief valve reached maximun allowed
Y Y Y Y
opening count
pressure relief valve is open Y Y Y Y
pressure relief valve reached maximun allowed open
Y Y Y Y
time
Reported MSC-Errors of a R2S2 Y Y Y Y
maximum positive deviation of rail pressure exceeded Y Y Y Y
leakage is detected based on fuel quantity balance Y Y Y Y
maximum negative rail pressure deviation with
Y Y Y Y
metering unit on lower limit is exceeded
minimum rail pressure exceeded Y Y Y Y
maximum rail pressure exceeded Y Y Y Y
setpoint of metering unit in idle mode not plausible Y Y Y Y
Rail pressure raw value is intermittent Y Y Y Y
rail pressure raw value is above maximum offset Y Y Y Y
rail pressure raw value is below minimum offset Y Y Y Y
maximum rail pressure exceeded : PRV not correctly
Y Y Y Y
opened
Sensor error high for rail pressure sensor Y Y Y Y
Sensor error low for rail pressure sensor Y Y Y Y
CAN signal error for PTO switch Y N Y Y
Signal Range Check High for APP1 Y N Y Y
Signal Range Check High for APP2 Y N Y Y
Signal Range Check Low for APP1 Y N Y Y
Signal Range Check Low for APP2 Y N Y Y
Error Sensor supplies 1 Y Y Y Y
Error Sensor supplies 2 Y Y Y Y
Error Sensor supplies 3 Y Y Y Y
ECU dataset variant identifier is invalid Y Y Y Y
An error has occurred in the switchover to the desired
Y Y Y Y
data set variant in the code word.
Short circuit to battery error on SpeedSel High side Y N Y Y
Short circuit to ground error on SpeedSel High side Y N Y Y
Open Load error on SVS lamp power stage Y N Y Y
Short circuit to battery error on SVS lamp Y N Y Y
Short circuit to ground error on SVS lamp Y N Y Y
Software reset 0 Y Y Y Y
ECU temperature too high Y Y Y Y
ECU temperature too low Y Y Y Y
ECU temperature sensor error Y Y Y Y
Intake temperature too high Y Y Y Y
Sensor error high for intake temperature sensor Y Y Y Y
Sensor error low for intake temperature sensor Y Y Y Y
Open Load error on ECU ON lamp power stage Y Y Y Y
Short circuit to battery error on ECU ON lamp Y Y Y Y
Short circuit to ground error on ECU ON lamp Y Y Y Y
Open Load error on SpeedSel Low side Y N Y Y
Short circuit to battery error on SpeedSel Low side Y N Y Y
Short circuit to ground error on SpeedSel Low side Y N Y Y
ComAp Delete if Delete
Comments
Display Healed delay
Y Y 2 ReInit.
Y Y 2 ReInit. air heater 2
Y Y 2 ReInit. air heater 1
Y Y 2 ReInit.
Y Y 2 ReInit. air heater 2
Y Y 2 ReInit. air heater 1
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit. Chg ECU
Y Y 2 ReInit. Chg ECU
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.

Y Y 2 ReInit.

Y Y 2 ReInit.

Y Y 2 ReInit.
In case of CAN gas lever
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
In case of CAN gas lever
Y N Chg ECU
Y N Chg ECU
Y Y 2 ReInit.
Y Y 2 ReInit. Detection dataset / ecu position mismatch
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y N

Y N
Y Y 2 ReInit.
Y Y 2 ReInit. Chg ECU
Y Y 2 ReInit. Chg ECU
Y N
Y N
Y N
Y N
Y N
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit. Connection error
Y Y 2 ReInit. Connection error
Y Y 2 ReInit. Connection error
Y Y 2 ReInit. Connection error
Y Y 2 ReInit. Connection error
Y Y 2 ReInit. Connection error
Y Y 2 ReInit.
Y N Re Init ECU
Y N Re Init ECU
Y N Chg ECU
Y N Chg ECU
Y N
Chg ECU
Y N Chg ECU
Y N
Chg ECU
Y N Chg ECU
Y N Chg ECU
Y N Chg ECU
Y N Chg ECU
Y N
Chg ECU
Y N Chg ECU
Y N Chg ECU
Y N Chg ECU
Y N
Y N
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y N
Chg ECU
Y N Chg ECU
Y N Chg ECU
Y N Chg ECU
Y Y 2 ReInit. Pressure out of range
Y Y 2 ReInit. Pressure out of range
Y Y 2 ReInit. Sensor error
Y Y 2 ReInit. Sensor error
Y Y 2 ReInit. Temp out of range
Y Y 2 ReInit. Sensor error
Y Y 2 ReInit. Sensor error
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y N
PRV has to be changed
Y Y 2 ReInit.
Y N
PRV has to be changed
Y Y 2 ReInit. Chg ECU
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y N Rail pressure sensor has to be changed
Y N Rail pressure sensor has to be changed
Y N Rail pressure sensor has to be changed
Y N
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit. Active in BMS ECO
Y Y 2 ReInit. Deactivated in case of CAN or 4-20mA gas lever
Y Y 2 ReInit. Deactivated in case of CAN or Potentiometer gas lever
Y Y 2 ReInit. Deactivated in case of CAN or 4-20mA gas lever
Y Y 2 ReInit. Deactivated in case of CAN or Potentiometer gas lever
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y N
Y N
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit. Deactivated in case of BMS ECO
Y Y 2 ReInit. Deactivated in case of BMS ECO
Y Y 2 ReInit. Deactivated in case of BMS ECO
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit. Chg ECU
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.
Y Y 2 ReInit.