-.Load which is same with the right side shown on primary menu.
-.0 means 0%, 1024 means 100% load. Normal Simplex
Eg.: if load is 50%, 512 should be shown. === 00000088 ===
-.If F187 is changed into 15, PTM #1 will appear. 1 Floor 0.00m/s
If it is changed into 16, PTM #2 will appear. Door Locked
3. Conduct constant-speed running within hoistway full area, and after determining start and stop state,
conduct adjustment.
-. Conduct adjustment after passing Para.setup mode.
F No. Relevant content Detailed technology
245 0% start compensation Start compensation adjustment on DN direction
248 adjustment Start compensation adjustment on UP direction
241 50% start If value of F247 is larger than 512, adjust DN direction.
242 compensation If value of F247 is larger than 512, adjust UP direction.
245 adjustment If value of F247 is less than 512, adjust DN direction.
248 If value of F247 is less than 512, adjust UP direction.
Unpublished Work Copyright © OTIS Elevator Company
IRIS1 NV
OTIS - SIGMA Date : 2011. 04. 10
FIELD ENGINEERING Page : 0 - 2 / 3
1) Shown as following figure, conduct line connecting work on indicator on hoistway side.