Professional Documents
Culture Documents
User Manual
General Features
Alarm Host
Remote Controllers
Functions Settings
1
General Features
Front Back
ARM : 02~99 defense zones will alarm when the detectors are triggered.
HOME ARM: Defense zones set into [Home Arm] won’t alarm even if it is triggered in ARM status.
DISARM : 02~99 defense zones won’t alarm when the detectors are triggered(except 24 hours defense zones)
3
Wired Ports Terminal
LCD Display
4
Specifications of Alarm Host
Power Supply: DC12V/1A
Wireless Frequency: 433MHz±0.5MHZ
GSM Frequency: 850/900/1800/1900MHz
Wireless Sensors: 99 wireless zones support up to 99 wireless sensors
Wired Sensors: 8 wired zones support numerous pieces of wired sensors
External Siren: Unlimited wireless flash sirens and one wired siren
Back-up Battery: Backup rechargeable battery can last up to 8 hours
Remote Control: Max support 5 remote controls
Standby Current: <55mA
Alarming Current: <450mA
Working Temperature: -10°C~+50°C
Humidity: ≤ 90% rh
Arm Button Remote Control SMS CALL
Material: ABS Plastic
Built-in Siren: 85dB
Preset Alarm Call Numbers: 6 groups
Preset Alarm SMS Numbers: 2 groups SMS CALL
Disarm Button Remote Control
Remote Control
5
Wireless Motion Sensor
Specifications Dimensions
Power Supply: 2xAAA 1.5V battery
Wireless Frequency: 433MHz
Transmission Distance: About 23m with one barrier
Detective Distance: 0.2 - 10m
Detective Speed: 0.3 - 3m/s
Detective Range: 8m~12m
Transmission Current: ≤25mA
Standby Current: ≤15uA
Working Temperature: -10°C~+55°C
Humidity: 45%-75% rh
Battery Lifespan: About 6 -12 months
Installation
6
Wireless Door sensors
Specifications Dimensions Installation
Power Supply: CR2032 3V lithium button cell battery
Wireless Frequency: 433MHz
Transmission Distance: About 23m with one barrier
Internal Distance: 20-25mm
Transmission Current: 8-12mA
Static Current: 1-5uA
Working Temperature: 15°C~35°C
Humidity: 45%-75% rh
Battery Lifespan: About 6 -12 months
Remote Controllers
Specifications
Power Supply: 27A 12V battery
Wireless Frequency: 433MHz
Transmission Distance: About 25M with one barrier
Emission Current: 10-18mA
Emission Speed: T≤1 second
Working Temperature: 15°C~35°C
Humidity: 45%-75% rh
Battery Lifespan: About 12 months 7
Functions Settings
1. Initialization
2. Program Status Setting
3. Program Password Change
4. Exit Setting Status
5. Remote Controllers Setting
6. Wireless Detector Setting
7. Defense Zone Attribute
8. Siren Setting
9. ARM/Alarm Delay Setting
10. Telephone Dial-UP Cycle Setting
11. Number of Ringtones For Remote Call
12. 10s Voice Recording
13. Password Change
14. Keypad Lock
15. ARM/DISARM Timing
16. Host Reset
17. Host Historical Records
18. SMS Notification for Arm/Disarm
19. Host Clock Setting
20. SMS Phone Number Setting
21. Alarm CALL Phone Number Setting
22. GSM Signal Checking
23. Direct Call from the Host
8
Function Settings
1. Initialization
Insert SIM card plug power adapter sound DI and all icons display on the LCD for 4 seconds GSM SIM Card
recognized when GSM signal indicator flashing continuously.
In Program Status Input [25] [#], then emit a long beep and voice prompt [deleted completed] sounds.
Operation: Input [6666] [#] Input [25] [#]
In Program Status Input [26] defense zone number [02 ~ 99] input [0~3] alarm type [#], then emit a long beep
and voice prompt [setting completed] sounds.
Operation: Input [6666] [#] Input [26] [XX] [Y] [#]
[XX]= [02 ~ 99] defense zone number
[Y]= [0 ~ 3] alarm type
11
7.2 Wired Detectors Alarm Type Setting
In Program Status Input [47] defense zone number [81 ~ 88] input [0~3] alarm type [#], then emit a long beep
and voice prompt [setting completed] sounds.
Operation: Input [6666] [#] Input [47] [XX] [Y] [#]
[XX]= [81 ~ 88] defense zone number
[Y]= [0 ~ 3] alarm type
In Program Status Input [60] defense zone number [02 ~ 99] input [1~8] alarm type [#], then voice prompt
[setting completed] sounds.
Operation: Input [6666] [#] Input [60] [XX] [Y] [#]
[XX]= [02 ~ 99] defense zone number
[Y]= [1 ~ 8] alarm type
[1] SOS Alarm
[2] Fire Alarm
[3] Gas Leak Alarm
[4] Door Lock Alarm
[5] Hall Alarm
[6] Window Alarm
[7] Balcony Alarm
[8] Perimeter Alarm
12
8. Siren Setting
8.1 External Siren Voice Prompt
When ARM or DIARM the host, the external siren has Arm/Disarm voice prompt.
In Program Status Input [31] input [0/1] [#], then emit a long beep and voice prompt [setting completed] sounds.
Operation: Input [6666] [#] Input [31] [0/1] [#]
[0]= External siren voice prompt closed
[1]= External siren voice prompt open
In Program Status Input [32] input time [00~15] minutes [#], then emit a long beep.
Operation: Input [6666] [#] Input [32] [XX] [#]
[XX]= siren ring time, unit “minute”.
In Program Status Input [33] input time [00~99] seconds [#], then emit a long beep and voice prompt [setting
completed] sounds.
Operation: Input [6666] [#] Input [33] [XX] [#]
[XX]= Arm delayed time, unit: second.
13
9.2 Alarm Delay(Entry Delay) (Maximum 99 seconds)
The host won’t alarm until the delayed time arrives.
In Program Status Input [34] input time [00~99] seconds [#], then emit a long beep and voice prompt [setting
completed] sounds.
Operation: Input [6666] [#] Input [34] [XX] [#]
[XX]= Alarm delayed time, unit: second.
In Program Status Input [35] input the number of times[00~09] [#], then emit a long beep and voice prompt [setting
completed] sounds.
Operation: Input [6666] [#] Input [35] [XX] [#]
[XX]= the number of cycle times
In Program Status Input [36] input the number of times[0~9] [#], then emit a long beep and voice prompt [setting
completed] sounds.
Operation: Input [6666] [#] Input [36] [X] [#]
[XX]= the number of ringtone times
14
12. 10s Voice Recording
In Program Status Input [37] [#], then emit a long beep, record starts with 10s counting down, the recorded voice
will replay after 10s.
Operation: Input [6666] [#] Input [37] [#]
Note: Record at 30cm away from the host and just begin recording another voice if the content need to be changed.
17
20. SMS Phone Number Setting
20.1 Add SMS Phone Number (Maximum 2 phone numbers)
In Program Status Input [49~50] input [YY…YY] [#], emit a long beep, the signal indicator flashes and voice
prompt [setting completed] sounds.
Operation: Input [6666] [#] Input [49~50] [YY…YY] [#]
[YY…YY]= phone numbers
In Program Status Input [49~50] [#], emit a long beep, the signal indicator flashes and voice prompt [setting
completed] sounds.
Operation: Input [6666] [#] Input [49~50] [#]
In Program Status Input [51~56] input [YY…YY] [#], emit a long beep, the signal indicator flashes and voice
prompt [setting completed] sounds.
Operation: Input [6666] [#] Input [51~56] [YY…YY] [#]
[YY…YY]= phone numbers
In Program Status Input [62] [#], emit a long beep and voice prompt [setting completed], then GSM signal value
displays.
Operation: Input [6666] [#] Input [62] [#]
In DISARM Status Input phone numbers [YY…YY] [ ] , emit a long beep and Signal Indicator Flashes
Direct CALL is available now. Press [ ] again to end the phone call.
19
CALL & SMS from and to the Host
20
CALL & SMS from and to the Host
1. Answer Alarm CALL from the host
If you answer the alarm call, you will hear the pre-recorded 10s voice and then set the system as below.
21
2. SMS Remote Control to the host
You can send SMS to ARM/DISRM the host and also to Turn on/off the siren.
ARM: [user password, defaulted 1234] [AMR], returned SMS[Armed] will be received and host shifts to ARM.
Operation: 1234ARM
DISARM: [user password, defaulted 1234] [DISARM], returned SMS[Disarmed] will be received and host shifts to
DISARM.
Operation: 1234DISARM
Turn on External Siren: [user password, defaulted 1234] [ONSIREN], returned SMS[Siren On] will be received.
Operation: 1234ONSIREN
Turn off External Siren: [user password, defaulted 1234] [OFFSIREN], returned SMS[Siren Off] will be received.
Operation: 1234OFFSIREN
You can CALL to ARM/DISARM the host. After you CALL the phone number in the host, it prompts [Please enter password,
defaulted password 1234]. If wrong password is input, it prompts [wrong password, please enter password again]. For
correct password, you can do the below settings to remote control the host.
[1]: The host shifts to ARM status with voice prompt [Armed].
[2]: The host shifts to DISARM status with voice prompt [Disarmed]
[3]: The host enters monitoring state for 30 seconds. Press [3] again for another 30 seconds.
[4]: 30s intercom
[#]: Hang up, alarm finishes. 22
Command Table
NOTE: Operate via alarm panel: In disarm status, please press 6666# via alarm panel to enter setup status first before inputting
the command.
24