Professional Documents
Culture Documents
Application Advisories
1. Use of the 200155 and 200157 Accelerometers with 1900
monitors or with TIMs other than those listed in Table 1 will
result in false readings.
2. Operating the transducers outside their specified limits will
result in false readings or loss of machine monitoring.
3. The maximum allowed cable length for use with the 200155 is
50 feet.
4. 20015x accelerometers may be installed in a Class I, Zone 0
application without a barrier, if they are being used with the
wSIM.
Page 1 of 18
Table 1: 20015x Accelerometer Applications
Standard Acceleration-to-Velocity
200150 General application
channel type (-01)
Application Advisory
If you plan to use housing measurements for overall machinery
protection, consider the usefulness of the measurement for each
application. Most common machine malfunctions (imbalance,
misalignment, etc.) originate at the rotor and cause an increase
(or at least a change) in rotor vibration. For the housing
measurement alone to be effective for overall machine
protection, the installation must faithfully transmit a significant
amount of rotor vibration to the bearing housing or machine
casing, or more specifically, to the mounting location of the
transducer.
Page 2 of 18
Specifications Settling Time
(Within 5% of
All specifications are at +25 ºC (+77 ºF), unless Bias)
otherwise specified.
See Table 4.
Electrical Table 4: Measurement Ranges
Sensitivity @ 80
Hz (± 12%) Accelerometer Settling Time (ms)
±2%
Electrical
Transverse
Isolation
Sensitivity
600 Vrms
≤7%
Page 3 of 18
Environmental Housing and
connector
Axial Shock material
Limit 200150
49,050 m/s2 pk (5,000 g pk) 316L stainless steel
Temperature 200155
Range
316L stainless steel
-40 ºC to +105 ºC (-40 ºF to +221
ºF) 200157
Sensing Seal
Element Connectors provide an IP67 seal
Ceramic to transducers and mating
hardware. Connectors are
Sensing molded to the cable. The addition
Geometry of DC4 electrical insulating
Shear compound in the connectors
provides additional protection
against moisture during a thermal
shock.
Page 4 of 18
Minimum Bend Hazardous Area Approvals
Radius Multiple approvals for hazardous areas certified by
200151 Canadian Standards Association (CSA) in North
America and LCIE in Europe.
63.5 mm (2.5 in)
200152 North American
Explosive Atmospheres
European Community Directives:
ATEX 1994/9/EC
Page 5 of 18
18 3/8-24 to M8x1 1-3/8 inch hex
Ordering Information plate stud
19 Quick-Set XDCR adapter,
Country specific approvals may be available.
1-inch hex stud
Please consult your local Customer Care
20 3/8-24 thread, 1 magnetic
Representative for more information.
mount base
21 3/8-24 outer diameter to M6x1
General Purpose Trendmaster 2000 or Trendmaster Pro
inner diameter 1-3/8 inch
Accelerometer hex plate stud
200150-AA-BB 22 3/8-24 to M8x1.25 1-3/8 inch
hex plate stud
Low Frequency Trendmaster Pro Accelerometer 23 3/8-24 to M16x2.0 1-3/8 inch
200155-AA-BB hex plate stud
BB: Approvals
Enveloping Trendmaster Pro Accelerometer 05 Multiple Approvals (CSA, ATEX,
200157-AA-BB and IECEx)
Refer to Table 6 for detailed specifications.
Note: Adhesive studs (Options 0 1 and 2 0) are sold in kits
AA: Mounting Stud Option containing frames to hold the studs to the
00 No mounting stud provided substrate while the adhesive cures. The kit also
01 3/8-24 thread, 2 adhesive contains a packet of acrylic adhesive and materials
mount frames with to mix its 2 components and provides a scouring
adhesive pad and alcohol wipe to prepare the mounting
02 3/8-24 to 3/8-24 UNF 1-3/8 surface.
inch hex plate stud
03 3/8-24 to 1/2-20 UNF 1-3/8
inch hex plate stud
04 3/8-24 to 1/4 NPT 1-3/8 inch
hex plate stud Application Advisory
05 3/8-24 to 1/4-28 UNF 1-3/8
inch hex plate stud Using adhesives and magnetic mounts will
06 3/8-24 to 1/4 NPT, 3/4 inch hex attenuate high frequency signals that may
stud be present.
07 3/8-24 to 3/8 NPT, 3/4 inch hex
stud
08 3/8-24 to 1/2 NPT 1 inch hex Accelerometer Interface Standard Cable, Connectors on
stud Both Ends
09 3/8-24 to 3/4 NPT, 1-1/4 inch 200151-AA-BB-CC
hex stud AA: Cable length
10 3/8-24 to 1 NPT, 1-3/8 inch hex 20 2.0 meters
stud 40 4.0 meters
11 3/8-24 to 1-1/4 NPT, 1-3/4 inch 60 6.0 meters
hex stud BB: Armor option
12 3/8-24 to 1/4-20 UNC, 3/4 inch 02 Blue cable without armor
hex stud 03 Blue cable with armor
13 3/8-24 to 5/16-18 UNC, 3/4 CC: Coupling nut
inch hex stud 00 Standard coupling nut (see
14 3/8-24 to 3/8-24 UNF, 3/4 inch Figure 9)
hex stud 02 Nylon coupling nut
15 3/8-24 to 3/8-16 UNC, 3/4 inch 10 Enhanced coupling nut. This
hex stud option provides a better grip
16 3/8-24 to 1/2-13 UNC, 3/4 inch for tightening the cable to the
hex stud accelerometer and is provided
17 3/8-24 to 3/8-16 UNC 1-3/8
inch hex plate stud
Specifications and Ordering Information
Part Number 164986-01
Rev. T (11/14)
Page 6 of 18
on both ends of the cable (see 126709-01
Figure 11).
Trendmaster 2000 for Windows
Installation Guide.
Accelerometer Interface Standard Cable, Connector on
Accelerometer End Only 141574-01
200152-AA-BB 200100 Acceleration-to-Velocity
AA: Cable length flexiTIM Module datasheet.
04 4.0 meters 137230-01
15 15 meters
25 25 meters FlexiTIM Operation Manual.
BB: Coupling nut 190125-01
00 Standard coupling nut (see
Figure 10) 1900/25 Vibration Monitor
10 Enhanced coupling nut. This Operation and Maintenance
option provides a better Manual.
grip for tightening the cable
141485-01
to the accelerometer and is
provided on the 1900/25 Vibration Monitor
accelerometer end only (see datasheet.
Figure 12).
190127-01
1900/27 Vibration Monitor
Operation and Maintenance
Accessories
Manual.
164985-01
141486-01
200150, 200155, and 200157
Accelerometers Installation 1900/27 Vibration Monitor
Guide. datasheet.
162411 141556
Page 7 of 18
Mechanical Specifications, Graphs, and Figures
Note: All dimensions shown in millimeters (inches) except as noted.
Table 6: Mounting Stud Specifications
Stud Length Recommended Torque Replacement
Option “A” Maximum Torque in N•m (in•lbf) Notes
in mm (in) in N•m (in•lbf) Part Number
Page 8 of 18
6.35 (0.25)
1. 3/8-24 UNF 2A
2. Stud length
Figure 1: Hex Plate Stud for “A” Options 02, 03, 05, 17, 18, and 23.
6.35 (0.25)
2
1. 3/8-24 UNF A
2. Stud length
Figure 2: Hex Plate Stud for “A” Option 04
6.4 (0.25)
2
1. 3/8-24 UNF 2A
2. Stud length
Figure 3: Hex Stud for “A” Options 06 Through 11
Page 9 of 18
1
2
19.1 (0.75)
1. 3/8-24 UNF 2A
2. Stud length
Figure 4: Hex Stud for “A” Options 12 Through 17
6.4 15.9
[0.250] [0.63] 2
1. 3/8-24 UNF 2A
2. Stud length
Figure 5: Quick-Set XDCR Adapter
6.4
[0.250] 1
1. 3/8-24 UNF 2A
Figure 6: Magnetic Mount Base
Page 10 of 18
1
1. 4
U 2
5.97N(0.235)
F
2A outer diameter
2. M6 x 1 inner diameter
1. 3/8-24 UNF 2A
2. M8 x 1,25
3. Stud length
Page 11 of 18
1
Page 12 of 18
Figure 13: Housing Cable Adapter (Part Number 142485-01)
Page 13 of 18
2
1 3
6
7
1. Top view
2. 19.1 mm (0.750 in) across corners
3. 11/16-inch hexagonal
4. Side view
5. 1/2-20 UNC-2A 5-pin connector
6. 3/8-24 UNF-2B threads, 7.1 mm (0.28 in) deep, minimum
7. 17.0 mm (0.67 in) diameter, typical
Figure 16: Accelerometer Dimensional Drawing
Page 14 of 18
200150
25
20
15
10
db
-5
-10
1 10 100 1000 10000 100000
Frequency
200150
50
-50
Phase
-100
-150
-200
1 10 100 1000 10000 100000
Frequency
Page 15 of 18
200155
25
20
15
db
10
-5
1 10 100 1000 10000 100000
Frequency
200155
50
-50
Phase
-100
-150
-200
1 10 100 1000 10000 100000
Frequency
Page 16 of 18
200157
25
20
15
db
10
-5
1 10 100 1000 10000 100000
Frequency
200157
50
-50
Phase
-100
-150
-200
1 10 100 1000 10000 100000
Frequency
Page 17 of 18
20015X - Sensitivity vs. Temperature
120.0
100.0
80.0
Sensitivity (mV/g)
60.0
40.0
20.0
0.0
-40 -20 0 20 40 60 80 100 120 140 160 180 200 220
Tem perature (°F)
* Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company.
Page 18 of 18