Voltage Regulator
REG-DA
* surface-mounting housing
* panel-mounting housing
* DIN-rails mounting
REG-DA a-eberle
LOCAL
SERVICE ACK
BLOCKED F1
F2
Furthermore, measurement values which are transferred to
F3
the regulator as mA signals from external sources can be
F4 displayed.
F5
Recorder mode
The change in the voltage over time and a second selectable
AUTO REMOTE ESC MENU measurement quantity are continuously shown on the display
LOCAL
in the form of a line chart. The time grid for the recording is
adjustable. The present tap position is recorded in addition
ACK
to the measurement values. Therefore it is possible to review
the voltage and the corresponding tap position at any time
during the recording.The average recording time for voltages
Parallel connection of transformers
and tap changes is approximately six weeks.
All regulators are able to control several transformers connec-
The stored values can be displayed with a time and date via
ted in parallel to one busbar without any additional devices.
the keyboard or the WinREG operating software.
Every regulator constantly indicates which reactive current
I · sinϕ is being used.
SERVICE SERVICE
BLOCKED F1 BLOCKED F1
F2 F2
F3 F3
F4 F4
F5 F5
LOCAL LOCAL
ACK ACK
LOCAL
SERVICE
ACK BLOCKED F1
F2
LOCAL
ACK
ParaGramer mode
The PARAGRAMER is a support tool for the automatic pre-
paration of parallel connections and the online display of the The regulator is equipped with a mA input as standard.
switching statuses. The temperature can be received as a mA signal by an
The artificial word PARAGRAMER is a combination of the two upstream temperature measurement transducer using this
terms parallel and one-line diagram. input.
The PARAGRAMER shows the switching status of the indi-
vidual transformers in a one-line diagram. If other combinations are required, e.g. temperature as a direct
The function is activated by feeding each regulator with a PT 100 connection and hot-spot temperature as a mA output,
complete busbar replica (position of circuit breakers, discon- the desired combination can be selected from the “E” and “C”
nectors, bus ties and bus couplings). groups of characteristics.
Based on the switching states of all regulators involved in
the parallel connection, the system autonomously detects
which transformer is to work with which other transformer(s)
in parallel connection on a busbar.
Busbars that are connected via bus coupling(s) are treated
as one single busbar by the system.
UL Certificate Number 050505 - E242284 The inputs can be continuously short-circuited or operated
open. All inputs are galvanically isolated from all other cir-
cuits.
Hous. COM 2
Test voltages Uh BO BI AI AO UE IE
COM 1 COM 3
Housing / COM 1 Hous. - 2.2 0.35 1.35 1.35 0.35 0.35 1.35 1.35
Auxiliary voltage Uh 2.2 - 3.7 2.9 2.9 3.7 3.7 2.6 2.6
COM 2/3 / IEC / DNP.. COMs 0.35 3.7 - 2.3 2.3 0.5 0.5 2.8 2.8
Binary outputs BO 2.0 2.9 2.3 - 2.0 2.3 2.3 2.6 2.6
Binary inputs (250 V) BI 2.0 2.9 2.3 2.0 - 2.3 2.3 2.6 2.6
Analogue inputs AI 0.35 3.7 0.5 2.3 2.3 - 0.5 2.8 2.8
Analogue outputs AO 0.35 3.7 0.5 2.3 2.3 0.5 - 2.8 2.8
Input voltage UE 1.35 2.6 2.8 2.6 2.6 2.8 2.8 - 2.2
Input current IE 2.0 2.6 2.8 2.6 2.6 2.8 2.8 2.2 -
Notes: All test voltages are AC voltages in kV which may be applied for 1 minute.
E-LAN, COM2, COM3 are tested against each other with 0.5 kV.
The following applies to all characteristics: Logic level of receiving output: CMOS
Voltage dips at nominal voltage that last ≤ 50 ms cause neither (Uhmin : > 0.9 V CC, Ulmax < 0.1 V CC @ Io = 1 mA)
a loss of data nor a malfunction.
Logic level of transmitting input: CMOS
(Uhmin : > 0.7 V CC, Ulmax < 0.3 V CC), Schmitt-Trigger
Environmental requirements
Dry, cold IEC 60068-2-1, - 15 °C / 16 h Optical transmitter
Product Type Fibre Pmin Pmax
Dry, hot IEC 60068-2-2, + 65 °C / 16 h [dBm] [dBm]
1) 1)
Constant humid heat IEC 60068-2-78 Glass ST HFBR 1414 T 50/125 μm -19.8 -12.8
+ 40 °C / 93 % / 2 days Glass SMA HFBR 1404 NA=0.2
λ = 820 nm
62.5/125 μm -16.0 -9.0
Cyclical humid heat IEC 60068-2-30 NA=0.275
12+12 h, 6 cycles 100/140 μm -10.5 -3.5
+55 °C / 93 % NA=0.3
200μm HCS -6.2 +1.8
Toppling IEC 60068-2-31 NA=0.37
100 mm drop, unwrapped
POF_ST HFBR 1515B 1 mm POF -7.5 -3.5
λ = 650 nm
Vibration IEC 60255-21-1, class 1 200μm HCS -18.0 -8.5
POF_SMA HFBR 1505C 1 mm POF -6.2 0.0
Impact IEC 60255-21-2, class 1 λ = 650 nm
200μm HCS -16.9 -8.5
Resistance to earthquakes IEC 60255-21-3, class 1 1) TA = 0..70°C, IF = 60 mA, measured after 1 m fibre optic cable.
Optical receiver
Storage
Device parameters Serial EEPROM with Product Type Fibre Pmin Pmax
[dBm] [dBm]
≥ 1000 k recording/reading 2) 2)
cycles
Glass ST HFBR 2412 T 100/140 μm -24.0 -10.0
RAM data Li battery laser-welded Glass SMA HFBR 2402 NA=0.3
(recorder function 0 ... 5 MBd
characteristic S1) λ = 820 nm
POF_ST HFBR 2515 B 1 mm POF -20.0 0.0
0 ... 10 MBd
Mechanical design λ = 650 nm 200μm HCS -22.0 -2.0
Housing Sheet steel, RAL 7035 grey
POF_SMA HFBR 2505 C 1 mm POF -21.6 -2.0
Height 288 mm
0 ... 10 MBd
Width 216 mm λ = 650 nm 200μm HCS -23.0 -3.4
Total depth 114 mm
Mounting depth 87 mm 2) TA = 0..70°C, VCC = 5 V ± 5%, output level LOW (active)
Weight ≤ 3 kg
Housing doors With silica glass
Front plate Plastic, RAL 7035 grey on
aluminium support
Control panel cutout
Height 282 mm
Width 210 mm
Degree of protection IP 54
Rain Test 3R UL50
REG-DA
SERVICE
BLOCKED F1
F2
F3
F4
F5
281 x 209
LOCAL
307
ACK
REGSys™ www.regsys.de
12
18 87 250
Mechanical dimensions
Panel mounting
Rear view
Cutout
282 x 210 mm
Panel
65
Standard DIN- rail mounting
Rear viev
127
5.5
6.5
surface / wall-mounting
Rear view
328
252
200
270
Level III
Level II
Level I
The hardware for all the instrumentation and control connec- Fibre optic cable connection (FSMA connection)
tions is contained on Level II.
The appropriate connection elements on Level II must be Furthermore, additional binary inputs and outputs as well
used for RS232 or RS485 connections. as mA inputs and outputs can also be accommodated on
If an ethernet connection is used, the corresponding con- Level II.
nection on Level II is also available (must be connected for
IEC 61850 or IEC 60870-5-104!). In total two spare slots are available and they can be equipped
For fibre optic cable connections ST or FSMA connectors are with the following modules:
mounted directy on the flange plate.This provides acess for
cable termination without having to open the Regulator. Module 1 : 6 binary inputs, 48 V...250 V AC/DC
Module 3 : 2 mA inputs
Module 4 : 2 mA outputs
Level I
8 Input voltage UL3
- U2 53 GND R6...R11
10 Input voltage -
54 Closes if fault occurs
Level I
1 k
Current input I1 55 Life contact (status) R13
3 l
4 k 56 opens if fault occurs
Current input I2 57 MANUAL
6 l
7 k 58 MANUAL / AUTO R12
Current input I3 59 AUTO
9 l
21 L / (+) 69 E-
UH = Auxiliary voltage 70 E+
22 L / (-) E-LAN (L)
63 mA input + A1 71 EA-
64 mA input - A1 72 EA+
61 mA input or output + A2 73 E-
Level III
62 mA input or output - A2 74 E+
E-LAN (R)
65 mA input or output + A3 65 75 EA-
66 mA input or output - A3 66 Level III 76 EA+
67 mA input or output + A4 77 Tx+
*
68 mA input or output - A4 68 78 Tx-
COM 3 (RS 485)
11 Binary input 1 Activity lamp 79 Rx+
12 Binary input 2 Freely programmable 80 Rx-
13 Binary input 3 Freely programmable 81
14 Binary input 4 Freely programmable 82 TxD
15 Binary input 1...4 GND 83 RxD
COM 2 (RS 232)
16 Binary input 5 AUTO 84 RTS
17 Binary input 6 MANUAL 85 CTS
18 Binary input 7 Freely programmable 86 GND
19 Binary input 8 Freely programmable ***
IEC SPA bus
20 Binary input 5...8 GND LON
Level II
Modbus
23 Binary input 9 BCD 1 DNP 3.0
24 Binary input 10 BCD 2
25 Binary input 11 BCD 4 See Level II pin assignment for additional
26 Binary input 12 BCD 8 Level II connections (page 13)
27 Binary input 9...12 GND
28 Binary input 13 BCD 10
Level I
* Option M1
29 Binary input 14 BCD 20
Used for standard applications,
30 Binary input 15 BCD sgn.
balanced load ( I1 = I2 = I3 ).
31 Binary input 16 Freely programmable
32 Binary input 13...16 GND Option M2
33 Only used for unbalanced load ( I1 ≠ I2 ≠ I3 ).
Freely programmable R5
34
35 Two different voltage inputs for U1 and U2 are required
Freely programmable R4 for triple-wound transformer applications.
36
37
Freely programmable R3 ** TC = tap changer
38
39 *** Please refer to the instrumentation and control
40 connections listed in the operating manual.
Lower R2
41
42
43 The assignment of pins 23 to 32 changes depending on
44 D0/D1/D4 and D2/D3.
Raise R1
45
46
SERVICE
BLOCKED F1
Display-Maße F2
67,8 x 67,8 mm
F3
X = 114,5
Y = 88,5 F4
F5
LOCAL
ACK
1 5
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 81 83 84 85 86
6 9
COM 1
Level III
100101 102 103 104 105 106 107 108 109 110 111 112 113 87 88 89 90 91 92 93 94 Ethernet connection Level II
(IEC 61850, IEC 60870-5-104)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Level I
23 24 25 26 27 28 29 30 31 32
Binary inputs
21 22
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Binary inputs
Relay outputs
SERVICE
BLOCKED F1
Display-Maße F2
67,8 x 67,8 mm
F3
X = 114,5
Y = 88,5 F4
F5
LOCAL
ACK
1 5
6 9
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 81 83 84 85 86
COM 1
Level III
100101 102 103 104 105 106 107 108 109 110 111 112 113 87 88 89 90 91 92 93 94 Ethernet connection Level II
(IEC 61850, IEC 60870-5-104)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Level I
23 24 25 26
Binary inputs
21 22 ON
1 2 Tap-change
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 potentiometer input
Relay outputs
Module 1
102 Binary input E19
101 Binary input E18 103 Binary input E20
Module 1
Module 2
109 R16
Characteristic C02 110 R17
12 additional binary inputs, 48 V ... 250 V AC/DC 111 R18
No. 112 R19
100 Binary input E17 113 GND R14...R19
101 Binary input E18
Module 1
102 R16
Analogue input E13
103 R17 107 -
104 R18
105 R19
Characteristic C08
106 GND R14 ... R19
2 additional analogue outputs
No.
Characteristic C04
100 +
Module 4
102 R16
103 R17 Characteristic C09
104 R18 4 additional analogue outputs
105 R19 No.
106 GND R14 ... R19 100 +
Module 4
RXD
RTS
TXD
CTS
GND
CTS
RTS
GND
RxD
TxD
Rx -
Rx +
Tx -
Tx +
E-
E+
EA -
EA +
E-
E+
EA -
EA +
Technical Data
10
48...250 V AC/DC
R10 >U
Keyboard
R9 <U
1 I
I1 R8 Local
3
R7 Remote
LCD
I
Characteristic M2 LED
52 51 50 49 48 47 53 57 58 59 54 55 56
R6 TC fault
I
14
7 I
I3 R1 Raise
9
CLOCK RAM/ROM
R3 progr.
48...250 V AC/DC
Level
Characteristicl E 91...99
Additional Inputs E1 ... E8 (D0) Inputs E9 ... E16 (D0)
Analogue inputs and outputs R4 progr.
inputs and outputs 48...250 V AC/DC 48...250 V AC/DC
Double modulel * Characteristic C01...C09
A1 A2 A3 A4 (See pin assignment R5 progr.
on page 13)
33 34 35 36 37 38 39 40 41 42 43 44 45 46
+ - + - + - + -
-
+
+
Legend:
optional
TC in op.
progr.
progr.
progr.
AUTO
MANUAL
progr.
progr.
BCD 1
mA input
mA input
Input or output
Input or output -
Input or output +
Input or output -
Input or output +
Input or output -
E1
E2
E3
E4
GND E1...E4
E5
E6
E7
E8
GND E5...E8
E9
E10 BCD 2
E11 BCD 4
E12 BCD 8
GND E9...E12
E13 BCD 10
E14 BCD 20
E15 BCD sgn.
E16 progr.
GND E13...E16
Level III II I
REG-DA
Technical Data REG-DA
Network / parallel connection RS48 interfaces
The networking of several regulators on a system is particu- Every REG-DA regulator is provided with a double E-LAN
larly required with transformers connected in parallel. The interface as a standard. It provides the bus connection of
∆I sinϕ, ∆I sinϕ (S) and Master-Slave parallel connection individual regulators and monitoring units to a form a voltage
programs can only be implemented by the system bus (E- control system.
LAN). This enables the individual group members of a parallel
connection to communicate with each other and without the E-LAN (Energy- Local Area Network)
need for additional components. Characteristics
The regulators do not need to be connected for the operation • 255 stations can be addressed
of a parallel connection which works in accordance with the • Multimaster structure
Δ cos φ procedure. Due to the large distances, such connec- • Integrated repeater function
tion is not normally possible anyway. • Open ring, bus or a combination of ring and bus is possible
• The record is based on SDLC/HDLC framework
• Transfer rate 62.5 or 125 kbit / sec
Serial interfaces • Telegram length 15.6 ... 375 kbit / s
RS232 interfaces
• Average throughput approx. 100 telegrams / sec at 62.5 k
The REG-DA has two RS232 interfaces (COM1, COM2).
COM 1 interface is used for configuring the regulator and
COM3
COM 2 is the scada interface designed to connect the regu-
For connection of ≤ 15 interface modules (BIN-D, ANA-D) in
lator to a higher-level instrumentation and control device.
any combination to any REG-DA regulator.
Connection elements
COM1 Sub Min D in the terminal
compartment, pin
The REGSimTM™ simulation software
REGSim™ was designed as a PC-based program for the
assignment as with PC
simulation of parallel connections of several transformers with
COM2 Pin connection in the
any possible combinations of network and load.
terminal compartment.
The transformers, the network and the load are simulated in
Connection possibilities PC, terminal, modem, PLC
a mathematically exact manner to ensure that the REG-DA
regulators operate in the same way in the simulation as they
No. of data bits/logs Parity 8, even, off, odd
do in the network.
Transmission rate bit / s 1200, 2400, 4800, 9600,
The authenticity of the simulation is guaranteed because REG-
19200, 38400, 57600,
SimTM uses the original algorithm of the REG-DA regulator.
76800, 115200
The simulation runs in real time and all the setting options
correspond to those in the real regulator.
HANDSHAKE RTS / CTS or XON / XOFF
Thus by using REGSim , the Regulator settings can be tested
and selected before commissioning.
REGSys™ - Overview
e
E-LAN
bl
ca
tic
IEC 61850
et
op
IEC 60850-5-101/103/104
rn
32
85
e
he
WinREG
S2
S4
br
MODBUS, SPABUS,
Et
Fi
R
1 1 1 1
2 2 2 2
Windows 95
3 3 3 3
4 4 4 4
Windows NT
EOR-D
Windows 2000
Windows XP E-LAN
E-LAN
COM3 a. eberlegmbh
P QI- D a. ebe rle gmbh
RS485
a. eberlegmbh
Status
1
2
3
4
Reset
C O M1
ANA-D ANA-D
N
LA
E-
5
<
RS485
a. eberle gmbh a. eberlegmbh
a. eberle gmbh MMU-D a. eb e rle gmbh
a. eber le gm bh
REG-DA
A: REG -D E 12:3 4:0 0
Status Störung Lauflampe Status F1 Stat us
Regler Status F1
<U Re geln AB GE STIMMT
< U1 M
Störung Rückführung Ipos = 98 .0 A V = +4.5 A
Stufenschalter läuft
>U F2 F2
1 Uo = 0.85 % d = 2.0 A
> U2 Uo
Auslösung >I 10
Leitungsschalter
F3 2
F3
>> U3 3
1
>> U4
F4 4 F4
0.1
>I F5 Reset F5
20A I m in I max 200A
Test COM1
REG-PC
COM1 C OM1
AUTO ESC MENU C O M1 ESC MENU
AUTO AU TO
ANA-D
a. eberlegmbh a. eberlegmbh
BCD-CODE
ANA-D ANA-D
REG-S REG-F(X)
CHARACTERISTIC CODE
REG-DA
Voltage Controller REG-DA , standard version, REG-DA
with E-LAN-double interface, COM1, COM2
one input for mA , 16 binary inputs and 12 relay outputs; status output;
inclusive software for setting parameters,
for programming and visualisation of all REG-DA data.
Power supply AC 85V ... 110V ... 264V / DC 88V ... 220V ... 280V H0
(from external source) DC 18V ... 60V ... 72V H2
Channel 1 Channel 2
-100 ... 0 ... +100 MW 0 ... 80 ... 120 V
-20 ... 0 ... +20 mA 4 ... 16 ... 20 mA
Channel 3 Channel 4
1 ... 19 taps 50 ... 140°C
0 ... 20 mA 4 ... 20 mA
CHARACTERISTIC CODE
REG-DA
Digital inputs and tap-potentiometer input
16 digital inputs AC/DC 48 V...250 V (E1…E16) D0
8 digital inputs AC/DC 10V..50V (E1…E8) and 8 digital inputs AC/DC 48V..250 (E9…E16) D1
16 digital inputs AC/DC 10 V...48 V (E1…E16) D4
16 digital inputs AC/DC 190 V...250 V (E1…E16) D7
resistor input (range as code E97) and 8 digital inputs AC/DC 48 V...250 V (E1…E8) D2
resistor input (range as code E98 ) and 8 digital inputs AC/DC 10 V...48 V (E1…E8) D3
resistor input (range as code E97) and 8 digital inputs AC/DC 10 V...48 V (E1…E8) D5
resistor input (range as code E98 ) and 8 digital inputs AC/DC 48 V...250 V (E1…E8) D6
Please note to code C90: Normally in level II there are only 2 places availaible
Each place can take either 6 binary inputs or 6 binary outputs or an analogue module;
For each analogue module 2 inputs for mA or 2 outputs for mA are available
In case that neither XW90, XW91 nor L1, L9 is selected,
up to four additional places are available
Type of connection
Copper conductors RS 232 V10
RS 485, two wire operation only V11
Fibre optic; connection with FSMA
glass fibre (wavelength 800..900 nm, distance < 2000 m) V13
plastic (wavelength 620..680 nm, distance < 50 m) V15
Fibre optic; connection with ST
glass fibre (wavelength 800..900 nm, distance < 2000 m) V17
plastic (wavelength 620..680 nm, distance < 50 m) V19
CHARACTERISTIC CODE
REG-DA
Protokoll: EC 60870-5-103 for ABB Z10
IEC 60870-5-103 for Areva Z11
IEC 60870-5-103 for SAT Z12
IEC 60870-5-103 for Siemens (LSA/SAS) Z13
IEC 60870-5-103 for Sprecher Automation Z14
IE 60C870-5-103 for others Z90