Operational Methods Sheet

OMS # P6XXI Smart Card Calibration OP # P6XXi line Page 1 of 9


TQC Work Content Verify Product Name: Ribbon pack out

IF YOU ARE NOT SURE…ASK! Rev. Date: 06-08-07 Rev: A


REV DESCRIPTION OF CHANGE CHANGED BY DATE Q.E. ENGR DATE
A Initial OMS Released Jose Aranda 6-8-07

Parts Required
900009-001 External smart card calibration fixture.
SLE 4442 Smart Card
SLE 4428 Smart Card

1. Install the calibration fixture as shown.

J16

Connect the calibration fixture to the P6XXi as


shown. D-Sub to D-sub and other end to J16 on the
Main PCBA
Operational Methods Sheet
OMS # P6XXI Smart Card Calibration OP # P6XXi line Page 2 of 9
TQC Work Content Verify Product Name: Ribbon pack out

IF YOU ARE NOT SURE…ASK! Rev. Date: 06-08-07 Rev: A


2. Plug the Power cable, Usb cable, and power ON the unit.

109

On

3. Load the feeder with smart cards.


Operational Methods Sheet
OMS # P6XXI Smart Card Calibration OP # P6XXi line Page 3 of 9
TQC Work Content Verify Product Name: Ribbon pack out

IF YOU ARE NOT SURE…ASK! Rev. Date: 06-08-07 Rev: A

4. Find the correct P6XXi driver, right click on it and select Properties.

5. Click on the Device Settings tab.


Operational Methods Sheet
OMS # P6XXI Smart Card Calibration OP # P6XXi line Page 4 of 9
TQC Work Content Verify Product Name: Ribbon pack out

IF YOU ARE NOT SURE…ASK! Rev. Date: 06-08-07 Rev: A


6. Click on the control button

7. Click the Advanced Utilities button


Operational Methods Sheet
OMS # P6XXI Smart Card Calibration OP # P6XXi line Page 5 of 9
TQC Work Content Verify Product Name: Ribbon pack out

IF YOU ARE NOT SURE…ASK! Rev. Date: 06-08-07 Rev: A


8. Click on the Smart Card Calibration button.

Check that the Smart Card fed correctly, wait for


approximately 1 to 5 minutes. When done, the Verify
T-03
Smart card will return to the feeder.

9. Turn the power off and remove the calibration fixture.


Operational Methods Sheet
OMS # P6XXI Smart Card Calibration OP # P6XXi line Page 6 of 9
TQC Work Content Verify Product Name: Ribbon pack out

IF YOU ARE NOT SURE…ASK! Rev. Date: 06-08-07 Rev: A


10. Plug the serial cable from the smart card reader box to the external smart card serial connector and
power ON the unit.

109
Operational Methods Sheet
OMS # P6XXI Smart Card Calibration OP # P6XXi line Page 7 of 9
TQC Work Content Verify Product Name: Ribbon pack out

IF YOU ARE NOT SURE…ASK! Rev. Date: 06-08-07 Rev: A

11. From your computer screen double click the shortcut to SC Test App.exe icon.

12. From the drop down arrow, select the desired P6XXi printer and click Select Printer.
Operational Methods Sheet
OMS # P6XXI Smart Card Calibration OP # P6XXi line Page 8 of 9
TQC Work Content Verify Product Name: Ribbon pack out

IF YOU ARE NOT SURE…ASK! Rev. Date: 06-08-07 Rev: A


13. From the drop down arrow select Ext SmartCard..

14. Verify that Ext SmartCard has been selected and select the correct Card Type to validate and click
Start.

Verify
165
Operational Methods Sheet
OMS # P6XXI Smart Card Calibration OP # P6XXi line Page 9 of 9
TQC Work Content Verify Product Name: Ribbon pack out

IF YOU ARE NOT SURE…ASK! Rev. Date: 06-08-07 Rev: A


15. When the Data Input box appears, type any two digits and click Enter.

4 2
1

7 5 3

8 6

9
0

9
EC-20

44

16. Verify that the two digits that were typed in the previous window it showing in this window.

Verify
T-03

End of Test.

Turn off the unit,


remove the smart cards
from the feeder and
unplug all cables.